Administrator Guide

5. In the right pane, select a disk and click Toggle Indicator.
The Toggle Indicator dialog box opens.
6. Click OK.
Clear the Swap Status for a Disk
Clear the swap status for a disk to acknowledge that it has been replaced.
Steps
1. If you are connected to a Data Collector, select a Storage Center from the drop-down list in the left navigation pane of Unisphere
Central.
2. From the SYSTEM menu, click Hardware.
The Hardware view is displayed.
3. Click the System tab.
4. In the System tab navigation pane, click Disks.
The Disks view is displayed.
5. In the right pane, select a disk, then click Request Swap Clear.
Managing Storage Center Controllers
Unisphere can help you manage and maintain the controllers in your Storage Center by walking you through the process for adding a
controller and replacing parts.
Add a Controller
This step-by-step wizard guides you through adding a new controller to the storage system.
Prerequisites
This wizard is only available for SC4020, SC8000, and SC9000 controllers.
The new controller must have a Hardware Serial Number (HSN) and Eth 1 IP address assigned to it before starting this procedure. To
see the new controller information, run the following command from the serial console:
controller show
Steps
1. If you are connected to a Data Collector, select a Storage Center from the drop-down list in the left navigation pane of Unisphere
Central.
2. From the SYSTEM menu, click Hardware.
The Hardware view is displayed.
3. Click the System tab.
4. In the System tab navigation pane, click Controllers.
The Controllers view is displayed.
5. Click Add Controller.
The Add New Controller wizard opens.
6. Confirm the details of your current install, and click Next.
7. Insert the controller into the existing enclosure. Click Next to validate the install.
8. Click Finish to exit the wizard.
168
Storage Center Maintenance