Administrator Guide

Storage Virtualization for SCv2000 Series Controllers
SCv2000 series controllers manage many storage virtualization options automatically.
Disk Management on SCv2000 Series Controllers
Storage Centers with SCv2000 series controllers manage disks automatically, limiting the disk management options. After adding disks,
Storage Center recognizes the new disks, creates a new disk folder if necessary, then manages the disks in the disk folder. If a disk is
intentionally down for testing purposes, then is deleted, you can restore the disk to manage the disk again in a disk folder.
The following disk management options are not available with SCv2000 series controllers:
Creating disk folders
Adding disks to disk folders
Managing disk spares
Storage Types for SCv2000 Series Controllers
SCv2000 series controllers create a storage type for each disk class, and manage storage types automatically.
SCv2000 series controllers manage storage types automatically in the following ways:
Storage types are created automatically for each disk class
Storage types have a 2MB page size for HDD folders and a 512 MB page size for SSD folders
Storage types cannot be modified
Non-redundant storage types are not allowed
RAID Tiering for SCv2000 Series Controllers
RAID tiering for SCv2000 series controllers moves data between RAID 10 and RAID 5/6. It does not move data between storage tiers.
RAID tiering happens at 7 PM every day. Data progression runs until it completes or reaches the maximum run time.
Storage Profiles for SCv2000 Series Controllers
The following table summarizes the storage profiles available to SCv2000 series controllers.
Name
Initial Write Tier Tier (T) and RAID Levels RAID Tiering
Balanced 1
Writes: T1 RAID 10
Snapshots: T1 RAID 5/6
Between RAID types only
Maximize Performance 1
Writes: T1 RAID 10
Snapshots: T1 RAID 10
No
Maximize Efficiency 1
Writes: T1 RAID 5/6
Snapshots: T1 RAID 5/6
No
Balanced
The Balanced storage profile balances efficiency and performance for any volume using that storage profile.
When a volume uses the Balanced storage profile, all new data is written to RAID 10. When Storage Center creates a snapshot, Data
Progression moves snapshot data from RAID 10 to RAID 5/6.
Maximize Performance
Maximize Performance keeps new data and snapshot data on RAID 10 to increase performance. Maximize Performance is useful for
volumes with important and frequently used data.
Maximize Efficiency
Maximize Efficiency writes new data to RAID 5/6 and keeps snapshot data on RAID 5/6. Use Maximize Efficiency for volumes with less-
important data and infrequently used data.
Storage Center Overview
27