Creating iSCSI Fault Domains
Create an iSCSI fault domain to group ports that can fail over to each other because they have connectivity to the same
resources.
NOTE: For user interface reference information, click Help.
Create a Physical iSCSI Fault Domain
Create a physical iSCSI fault domain to group physical ports for failover purposes.
Prerequisites
In virtual port mode, all iSCSI ports that are connected to the same iSCSI network should be added to the same fault domain.
In legacy mode, each pair of primary and reserved ports that are connected to the same iSCSI network should be added to a
unique fault domain. The primary port should be located on a different controller than the secondary port.
Physical ports cannot be selected and added to a fault domain if they are already added to another fault domain.
Each iSCSI port that you want to add to the fault domain must be assigned an IP address, subnet mask, and gateway in the
same network as the iSCSI control port for the fault domain.
About this task
NOTE: iSCSI ports must be configured in virtual port mode when using SCv2000 and SCv3000 series controllers. Legacy
mode is not supported.
Steps
1. If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2. Click the Storage tab.
3. In the Storage tab navigation pane, expand Fault Domains, then select iSCSI.
4. In the right pane, click Create Fault Domain. The Create Fault Domain dialog box opens.
5. In the Name field, type a name for the fault domain.
6. (Virtual port mode only) Configure an IP address and gateway for the iSCSI control port in the fault domain. Servers target
this IP address using iSCSI initiators, and the Storage Center redirects individual iSCSI connections to the appropriate virtual
port.
a. In the Target IPv4 Address field, type an IP address to assign to the iSCSI control port.
b. In the Subnet Mask field, type the subnet mask for the well-known IP address.
c. In the Gateway IPv4 Address field, type the IP address for the iSCSI network default gateway.
7. (Optional) In the Target IPv6 Address field, type an IP address to assign to the iSCSI control port.
8. (Optional) If necessary, assign a VLAN ID to the fault domain.
NOTE:
If the Storage Center does not meet the multi-VLAN tagging requirements, a VLAN ID cannot be specified at
this time. Instead, modify the fault domain after it is created to add a VLAN ID.
a. Select the Physical option if you want to create a physical fault domain, that is, a fault domain that consists of physical
ports.
b. Select the Virtual option if you want to create a fault domain that consists of virtual ports.
c. Select the VLAN Tagged check box if you want to create a tagged fault domain that consist of physical ports.
d. In the VLAN ID field, type a VLAN ID for the fault domain. Allowed values are 14096.
e. (Optional) To assign a priority level to the VLAN, type a value from 07 in the Class of Service Priority field. 0 is best
effort, 1 is the lowest priority, and 7 is the highest priority.
9. In the Ports table, select the iSCSI ports to add to the fault domain. All iSCSI ports in the fault domain should be connected
to the same Ethernet network.
If creating a physical fault domain, physical ports appear in the list only if they are not assigned to any fault domain yet.
10. Click OK.