Administrator Guide

Table Of Contents
Clear the Swap Status for an Enclosure Power Supply
Clear the swap status for an enclosure power supply to acknowledge that it has been replaced.
Steps
1. If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, expand Enclosures, then select and expand an enclosure.
The Enclosure view is displayed.
4. Under the selected enclosure, click Power Supplies.
The Power Supplies view is displayed.
5. In the right pane, select the power supply, then click Request Swap Clear.
Replace a Failed Power Supply
This step-by-step wizard guides you through replacing a failed power supply in an enclosure in the Storage Center.
Prerequisites
This wizard is only available for the SCv2000 series, and can be completed without a controller outage.
Steps
1. If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, expand Enclosures, then select and expand the enclosure with the failed power
supply.
The Enclosure view is displayed.
4. Under the selected enclosure, click Power Supplies.
The Power Supplies view is displayed.
5. In the right pane, select the failed power supply, then click Replace Power Supply.
The Replace Failed Power Supply wizard opens.
6. Refer to the graphic in the wizard to locate the failed power supply. Click Next.
7. Follow the instructions to remove the failed power supply. Click Next.
8. Follow the instructions to insert the replacement power supply. Click Next to verify the replacement.
If this verification fails, an error message is displayed. You can proceed to the next step once the error is corrected and
validated.
9. Click Finish to exit the wizard.
Clear the Under Voltage Status for a Power Supply
Clear the under voltage status for an enclosure power supply to acknowledge that you are aware of it.
Steps
1. If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, expand Enclosures, then select and expand an enclosure.
The Enclosure view is displayed.
4. Under the selected enclosure, click Power Supplies.
The Power Supplies view is displayed.
5. In the right pane, select the power supply, then click Request DC Undervoltage Clear.
288
Storage Center Maintenance