Administrator Guide

Table Of Contents
Event Name Description
Directory Services
Communication
The Data Collector cannot communicate with the Directory Services.
Exception Sending Email Unable to send email to configured user.
Failed to Startup The Data Collector service failed to startup.
Port Conflicts Required ports are not available.
Remote Data Collector Down Data Collector no longer communicating with the Remote side.
Replication Validation Errors Automated replication validation errors found an error.
SMI-S Server Error Error installing, starting, or running the SMI-S server
Space Recovery Report Report of an automated space recovery run.
Storage Center Connect
Timeout
Storage Center connect timeout threshold has been exceeded.
Storage Center Down A Storage Center is no longer able to communicate with the Data Collector.
Storage Center Ping Timeout Storage Center ping timeout threshold has been exceeded.
Storage Center Read Timeout Storage Center read timeout threshold has been exceeded.
SupportAssist Errors Sending information to the SupportAssist Server has had errors
Threshold Alerts At least one threshold alert has exceeded its limit.
Example of a Storage Manager Data Collector alert
An alert is generated when the disk partition on which the Storage Manager Data Collector is located starts to run out of space.
If the amount of disk space remaining is less than 25%, an event with a severity of Warning and the message Disk
partition containing Dell Storage Manager is running low on space is displayed.
If the amount of disk space remaining is less than 10%, an event with a severity of Error and the message Disk
partition containing Dell Storage Manager is running low on space is displayed
If the amount of disk space remaining is less than 3%, an event with a severity of Exception and the message Disk
partition containing Dell Storage Manager is full is displayed.
Storage Center Monitoring
613