RACADM Command Line Reference Guide for iDRAC7 1.30.30 and CMC 4.
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2012 Dell Inc.
Contents Notes, Cautions, and Warnings...................................................................................................2 1 Introduction................................................................................................................................33 New in This Release...............................................................................................................................................33 Supported RACADM Interfaces....................................
getassettag.............................................................................................................................................................62 getchassisname......................................................................................................................................................62 getconfig.................................................................................................................................................................
set.........................................................................................................................................................................117 setarraycfg............................................................................................................................................................118 setassettag..........................................................................................................................................................
cfgNicIPv4Enable (Read or Write).................................................................................................................145 cfgNicSelection (Read or Write)....................................................................................................................145 cfgNicVLanEnable (Read or Write)................................................................................................................145 cfgNicVLanId (Read or Write)....................................
cfgRhostsSyslogServer1 (Read/Write)...........................................................................................................157 cfgRhostsSyslogServer2 (Read/Write)...........................................................................................................157 cfgRhostsSyslogServer3 (Read/Write)...........................................................................................................157 cfgRhostsSyslogPowerLoggingEnabled........................................
cfgTrapsIndex (Read Only).............................................................................................................................170 cfgTrapsEnable..............................................................................................................................................170 cfgTrapsAlertDestIpAddr...............................................................................................................................170 cfgTrapsCommunityName.......................
cfgServerFW (Read Only)...............................................................................................................................181 cfgServerBIOS (Read Only)............................................................................................................................181 cfgServerBmcMacAddress (Read Only)........................................................................................................181 cfgServerNic1MacAddress (Read Only)............................
cfgLdapEnable (Read/Write)..........................................................................................................................191 cfgLdapServer (Read/Write)..........................................................................................................................192 cfgLdapPort (Read/Write)..............................................................................................................................192 cfgLdapBasedn (Read/Write)............................
cfgChassisPowerCapBTU (Read/Write)........................................................................................................201 cfgChassisPowerCapFBTU (Read/Write).......................................................................................................201 cfgChassisPowerCapPercent (Read/Write)...................................................................................................201 cfgChassisPowerCapFPercent (Read/Write)................................................
cfgIpmiPetAlertDestIpAddr (Read/Write)......................................................................................................210 cfgIpmiPetAlertEnable (Read/Write)..............................................................................................................210 cfgUserDomain.....................................................................................................................................................210 cfgUserDomainIndex (Read Only)........................
cfgKVMInfo...........................................................................................................................................................220 cfgKVMAccessToCMCEnable........................................................................................................................220 cfgKVMFrontPanelEnable..............................................................................................................................220 cfgAlerting.................................
cfgIPv6StaticEnable (Read or Write).............................................................................................................229 cfgIPv6StaticAddress1 (Read or Write).........................................................................................................229 cfgIPv6StaticGateway (Read or Write)..........................................................................................................229 cfgIPv6StaticPrefixLength (Read or Write)...............................
cfgSmartCard........................................................................................................................................................237 cfgSmartCardLogonEnable (Read/Write).......................................................................................................237 cfgSmartCardCRLEnable (Read/Write)..........................................................................................................237 cfgNetTuning.............................................
4 Database Objects With Get and Set Commands...............................................................247 System.LCD...........................................................................................................................................................247 System.LCD.Configuration (Read or Write)....................................................................................................247 System.LCD.CurrentDisplay (Read Only)...................................................
System.Power.Max.LastWeek (Read Only)....................................................................................................256 System.Power.Max.LastWeek.TimeStamp (Read Only)................................................................................256 System.Power.Max.Power (Read Only).........................................................................................................256 System.Power.Max.Power.Timestamp (Read Only).....................................................
iDRAC.ActiveDirectory.Enable (Read or Write).............................................................................................265 iDRAC.ActiveDirectory.GCLookupEnable (Read or Write).............................................................................265 iDRAC.ActiveDirectory.GCRootDomain (Read or Write)................................................................................266 iDRAC.ActiveDirectory.GlobalCatalog1 (Read or Write)....................................................
iDRAC.IPMISerial.BaudRate (Read or Write).................................................................................................274 iDRAC.IPMISerial.ChanPrivLimit (Read or Write)..........................................................................................274 iDRAC.IPMISerial.ConnectionMode (Read or Write).....................................................................................274 iDRAC.IPMISerial.DeleteControl (Read or Write)................................................
iDRAC.IPv6.Address12 (Read Only)................................................................................................................283 iDRAC.IPv6.Address13 (Read Only)................................................................................................................283 iDRAC.IPv6.Address14 (Read Only)................................................................................................................284 iDRAC.IPv6.Address15 (Read Only)....................................
iDRAC.NIC.............................................................................................................................................................292 iDRAC.NIC.AutoDetect (Read or Write).........................................................................................................292 iDRAC.NIC.Autoneg (Read or Write)..............................................................................................................292 iDRAC.NIC.DedicatedNICScanTime (Read or Write)....
iDRAC.Security.CsrCommonName (Read or Write).......................................................................................301 iDRAC.Security.CsrCountryCode (Read or Write)..........................................................................................301 iDRAC.Security.CsrEmailAddr (Read or Write)..............................................................................................302 iDRAC.Security.CsrKeySize (Read or Write)........................................................
iDRAC.Telnet.Port (Read or Write).................................................................................................................310 iDRAC.Telnet.Timeout (Read or Write)...........................................................................................................310 iDRAC.Time...........................................................................................................................................................310 iDRAC.Time.Timezone (Read or Write)...........
BIOS.BiosBootSettings.........................................................................................................................................319 BIOS.BiosBootSettings.BiosBootSeq (Read or Write)...................................................................................319 BIOS.BiosBootSettings.BootMode (Read or Write).......................................................................................319 BIOS.BiosBootSettings.BootSeqRetry (Read or Write)...........................
BIOS.MemSettings.VideoMem (Read Only)...................................................................................................329 BIOS.MiscSettings................................................................................................................................................329 BIOS.MiscSettings.AssetTag (Read or Write)...............................................................................................329 BIOS.MiscSettings.ErrPrompt (Read or Write).......................
BIOS.ProcSettings.ProcBusSpeed (Read Only).............................................................................................338 BIOS.ProcSettings.ProcCores (Read or Write)..............................................................................................338 BIOS.ProcSettings.ProcCoreSpeed (Read Only)...........................................................................................339 BIOS.ProcSettings.ProcDramPrefetcher (Read or Write)..........................................
BIOS.SataSettings.SataPortFCapacity (Read Only).......................................................................................348 BIOS.SataSettings.SataPortFDriveType (Read Only).....................................................................................348 BIOS.SataSettings.SataPortFModel (Read Only)...........................................................................................349 BIOS.SataSettings.SataPortG (Read or Write).......................................................
BIOS.SysProfileSettings.ProcTurboMode (Read or Write)............................................................................358 BIOS.SysProfileSettings.SysProfile (Read or Write)......................................................................................359 BIOS.SysSecurity..................................................................................................................................................359 BIOS.SysSecurity.AcPwrRcvry (Read or Write)..............................
NIC.FCoEConfiguration.MTUParams (Read or Write)....................................................................................369 NIC.FCoEGenParams............................................................................................................................................369 NIC.FCoEGenParams.FCoEBootScanSelection (Read or Write)....................................................................369 NIC.FCoEGenParams.FCoEFabricDiscoveryRetryCnt (Read or Write)............................
NIC.IscsiInitiatorParams.IscsiInitiatorPrimDns (Read or Write)....................................................................379 NIC.IscsiInitiatorParams.IscsiInitiatorSecDns (Read or Write).....................................................................379 NIC.IscsiInitiatorParams.IscsiInitiatorSubnet (Read or Write)......................................................................379 NIC.IscsiInitiatorParams.IscsiInitiatorSubnetPrefix (Read or Write)..........................................
NIC.VndrConfigGroup.iSCSIOffloadSupport (Read Only)...............................................................................388 NIC.VndrConfigGroup.LinkStatus (Read Only)...............................................................................................388 NIC.VndrConfigGroup.MacAddr (Read Only).................................................................................................389 NIC.VndrConfigGroup.NicMode (Read or Write)......................................................
Introduction 1 This document provides information about the RACADM subcommands, supported RACADM interfaces, and property database groups and object definitions for the following: • iDRAC Enterprise or Express for Blade Servers • iDRAC Enterprise or Express on Rack and Tower Servers • Dell Chassis System (CMC) NOTE: In this version of RACADM, the Linux shell features such as ctrl+d, home, del, and end shortcut keys are not supported. New in This Release • • For iDRAC7 version 1.30.
Supported RACADM Interfaces The RACADM command-line utility provides a scriptable interface that allows you to locally or remotely configure your Remote Access Controller (RAC). The utility runs on the management station and the managed system. It is available on the Dell OpenManage Systems Management and Documentation DVD or at support.dell.com. The RACADM utility supports the following interfaces: • Local — Supports executing RACADM commands from the managed server’s operating system.
Remote RACADM racadm -r -u -p getconfig -g [-o ] [-i ] racadm -r -u -p Example racadm -r -u -p getconfig -g idracinfo racadm -r -u -p getsysinfo RACADM Command Options The following table lists the options for the RACADM command: Option Description -r -r : Specifies the co
Supported RACADM Subcommands The following table provides the list of RACADM subcommands and their corresponding interface support. For detailed information of the RACADM subcommands including syntax and valid entries, see RACADM Subcommand Details.
Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower Servers CMC getioinfo No No No No No No Yes Yes getkvminfo No No No No No No Yes Yes getled Yes Yes Yes Yes Yes Yes Yes Yes getmacaddress No No No No No No Yes Yes getmodinfo No No No No No No Yes Yes getniccfg Yes Yes Yes Yes Yes Yes Yes Yes getpbinfo No No No No No No Yes Yes getpminfo No No No No No No Yes Yes getraclog Yes Yes Yes Yes Yes Yes Yes Yes getractime
Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower Servers CMC racreset Yes Yes Yes Yes Yes Yes Yes Yes racresetcfg Yes Yes Yes Yes Yes Yes Yes Yes raid Yes Yes Yes Yes Yes Yes Yes Yes remoteimage Yes Yes Yes Yes Yes Yes Yes Yes serveraction Yes Yes Yes Yes Yes Yes Yes Yes set Yes Yes Yes Yes Yes Yes No No setarraycfg No No No No No No Yes Yes setassettag No No No No No No Yes Yes setchassisname No No No No No No Yes
Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower Servers CMC usercertview Yes Yes Yes Yes Yes Yes No No vflashsd Yes Yes Yes Yes Yes Yes No No vflashpartition Yes Yes Yes Yes Yes Yes No No vmdisconnect Yes Yes Yes Yes Yes Yes No No Other Documents You May Need In addition to this guide, you can access the following guides available on the Dell Support website at support.dell.com/ manuals. On the Manuals page, click Software → Systems Management .
RACADM Subcommand Details 2 This section provides detailed descriptions of the RACADM subcommands including the syntax and valid entries.
NOTE: An empty string may be specified as either "" (using double quotes) or '' (using single quotes). "?"and "?" Description Displays all the subcommands you can use with the RACADM command and a one-line description of each subcommand. ? followed by displays the syntax for the specified command. To use this subcommand, you must have CMC Login User privilege. You can also use the help and help commands to obtain the same information.
-c -A -4 -6 : : : : show chassis information do not show headers or labels show CMC IPv4 information show CMC IPv6 information help and help Description Synopsis Input Output Lists all the subcommands available for use with RACADM and provides a short description for each. You may also type a subcommand, group, object, or FQDD alias after help. • • • • • • • help help help help help help help -g -o . .
IP Address HW Type Flags HW Address Mask Device 192.168.1.1 0x1 0x2 00:00:0C:07:AC:0F * eth0 autocomplete Description Displays all the available racadm commands in the alphabetical order on pressing the key. Type the starting letter of the command and press key to complete the command Synopsis racadm> Input racadm> Output The Input command displays the list of subcommands.
Input racadm> cd
To use this subcommand, you must have Chassis Control Administrator privilege Synopsis Input racadm chassisaction [-m ] -m — Module on which you want to carry out the action. Values are: • — chassis - this is the default value if -m is not specified. — switch-n where n=1–6 — kvm — Action that you want to execute on the specified module. Values are: • — powerdown — (Chassis only) Powers down the chassis. — powerup — (Chassis only) Powers up the chassis.
closessn Description Closes a communication session on the device. Use getssninfo to view a list of sessions that can be closed using this command. To use this subcommand, you must have Administrator permission. Synopsis Input • • • racadm closessn –i racadm closessn -a racadm closessn -u • -i — The session ID of the session to close, which can be retrieved using racadm getssninfo subcommand. Session executing this command cannot be closed.
To use this subcommand, you must have Administrator privilege. NOTE: This command is valid only in redundant CMC environments. For more information, see the "Understanding the Redundant CMC Environment" section of the Dell Chassis System User Guide. Synopsis racadm cmcchangeover Input None Output CMC failover initiated successfully.
• • -c — The -c, or check option, is used with the config subcommand and allows the user to parse the .cfg file to locate syntax errors. If errors are found, the line number and a short description of what is incorrect are displayed. Write permission does not apply to iDRAC. This option is a check only.
Input -b — Connects to the switch or console using the binary mode. This is an optional argument; a server or a switch must be present. NOTE: If you use the -b option, reset the CMC to terminate the connect operation. • • server-nx — where n=1-8 ; x = a,b,c,d switch-n — switch-n where n= coredump Description Displays detailed information related to any recent critical issues that have occurred with iDRAC.
This option is applicable only for iDRAC. To use this subcommand, you must have Clear Logs or Execute Debug Commands permission. NOTE: If a coredumpdelete command is issued and a coredump is not currently stored in the RAC, the command displays a success message. This behavior is expected. See the coredump subcommand for more information on viewing a coredump. Synopsis racadm coredumpdelete Input None Output Coredump is deleted.
• • -u root — Indicates that the is supplied for the root user on the server or switch. Root is a constant parameter, the only value that is valid with the ‑u option. -m — Specifies the server or switch you want to configure. Legal values: sever-n, where n=1–16 server-nx where n=1– 8; x = a,b,c,d switch-n, where n=1– 6 -p — Specifies the password for the root user on the server or switch.
To use this subcommand with the get and test option, you must have Administrator privilege. This subcommand is applicable only for iDRAC. Synopsis racadm eventfilters racadm eventfilters get -c racadm eventfilters set -c -a -n racadm eventfilters set -c -a -r racadm eventfilters test -i NOTE: The general format of an alert descriptor: idrac.alert.category.
• -r — Event generation interval. This is applicable only to the temperature statistics subcategory - tmps. You can use this option as a stand-alone or with -n and -a. NOTE: If both event generation interval and notifications are configured and there is an error while configuring the notifications, the event generation interval is not set. The valid values are from 0 - 365. 0 disables the event generation. Example 54 • Display all available event filter configurations: racadm eventfilters get -c idrac.
feature Description Displays all active chassis features. The information displayed includes feature name, date activated, and the serial number of the SD card used to activate the feature. Dell Feature Cards may contain more than one feature. After any feature included on a Dell Feature Card is activated on a chassis, any other features that may be included on that Dell Feature Card cannot be activated on a different chassis.
Output • • • • • Example No feature card inserted — Action: Check the CMC to verify that the SD card was properly inserted. In a redundant CMC configuration, make sure the CMC with the SD feature card installed is the active CMC and not the standby CMC. The feature card inserted is valid and contains the following feature(s) FlexAddress: The feature card is bound to this chassis — Action: No action required. No features active on the chassis — Action: Install the SD card into the CMC.
at any time. In addition, the fwupdate subcommand may only update one or more devices of a single kind at a time. To use this subcommand for CMC you must have Chassis Configuration Administrator privilege and for iDRAC you must have Configure iDRAC permission. NOTE: Running the fwupdate subcommand to update the firmware on the active CMC resets itself causing all network connections to be dropped.
Input • • -u — For iDRAC: The update option performs a checksum of the firmware update file and starts the actual update process. This option may be used along with the -g or -p options. At the end of the update, iDRAC performs a soft reset. For CMC: Performs the firmware update operation. -s— For iDRAC: The status option returns the current status of where you are in the update process. This option is always used by itself. Lists active SD card features and SD card status.
NOTE: iDRAC7 targets are not supported from CMC. Use the CMC GUI to update iDRAC7 targets from CMC. CMC version 3.00 accepts IPv4, IPv6, or fully qualified domain names (FQDN) for both FTP and TFTP servers. NOTE: You can specify the cmc-active and cmc-standby modules at the same time along with one or more server-n modules. This enables the devices to be updated together. This option is applicable only for CMC.
NOTE: For CMC, these commands specifically apply to an active-CMC update. The following table describes the firmware update method supported for each interface.
• • • • • • • Examples
configuration completed successfully. Example • Get the configured storage array properties from server-3 racadm getarraycfg -m server-3 • Query for current storage configuration process status on server-3 racadm getarraycfg -m server-3 -s getassettag Description Displays the asset tag for the chassis. To use this subcommand, you must have CMC Login User privilege. Synopsis racadm getassettag [-m ] Input -m — Specifies the module whose asset tag you want to view.
Input • • • • • • • Output -f — The -f option directs getconfig to write the entire iDRAC configuration to a configuration file. This file can be used for batch configuration operations using the config subcommand. -g — The -g , or group option, can be used to display the configuration for a single group. The groupName is the name for the group used in the racadm.cfg files. If the group is an indexed group, use the -i option.
racadm getconfig -u root • Displays the user group instance at index 2 with verbose information for the property values. racadm getconfig -g cfgUserAdmin -i 2 -v getdcinfo Description Displays general I/O module and daughter card configuration information. Only the CMC controls daughtercards. To use this subcommand, you must have CMC Login User privilege. NOTE: Fabric verification for server DCs is performed only when the chassis is powered on.
server-4 Present None N/A Gigabit Ethernet OK server-5 Not Present None N/A None N/A server-6 Not Present None N/A None N/A server-7 Not Present None N/A None N/A server-8 Present FibreChannel Invalid 4 None N/A server-9 Extension(1) None N/A None N/A server-10 Not Present None N/A None N/A server-11 Not Present None N/A None N/A server-12 Not Present None N/A None N/A server-13 Not
server-13 Not Present None None server-14 Not Present None None server-15 Not Present None None server-16 Not Present None None getflexaddr Description Displays enabled/disabled status for the entire chassis. If used with -i, the command displays MACs/WWN on a per slot basis. To use this subcommand, you must have CMC Login User privilege. NOTE: If FlexAddress is not activated on the chassis, the command displays server-assigned MAC/WWN addresses.
9 Enabled Not Present 10 Enabled Extension(2) 11 Enabled Not Present 12 Enabled Not Present 13 Enabled Extension(5) 14 Enabled Not Present 15 Enabled Not Present 16 Enabled Not Present idrac System Disabled Display the current flex address setting for slot 1.
getfanreqinfo Description Displays fan speed request for Servers and Switches in percent (%). To use this subcommand, you must have CMC Login User privilege. This subcommand is not applicable for iDRAC.
14 SLOT-14 PowerEdgeM60 ON 0 Present 33 15 SLOT-15 N/A N/A Not Present N/A 16 SLOT-16 N/A Extension(8) N/A N/A Switch Module Fan Request Table 1 SLOT-01 PowerEdgeM60 ON 0 Present 33 2 SLOT-02 PowerEdgeM90 ON 5 Present 35 3 SLOT-03 PowerEdgeM71 ON 0 Present 44 4 SLOT-04 PowerEdgeM61 ON 0 Present 46 5 SLOT-05 PowerEdgeM61 ON 0 Present 46 6 SLOT-06 Not Present N/A 7 SLOT-07 PowerEdgeM
Switch-1 Dell Ethernet Pass-Through Gigabit Ethernet Present 30 Switch-2 Dell PowerConnect M6220 Gigabit Ethernet Present 30 Switch-3 N/A None Not Present N/A Switch-4 N/A None Not Present N/A Switch-5 N/A None Not Present N/A Switch-6 N/A None Not Present N/A getioinfo Description Displays general information about the I/O modules on the chassis. To use this subcommand, you must have CMC Login User privilege.
getkvminfo Description Displays iKVM module information. To use this subcommand, you must have CMC Login User privilege. Synopsis racadm getkvminfo Example racadm getkvminfo KVM Present Avocent iKVM Switch 00.05.00.04 Ready getled Description Displays the LED settings on a module: blinking, not blinking, or unknown (for empty slots). To use this subcommand, you must have Login User privilege.
getmacaddress Description Synopsis Input Displays the MAC/WWN addresses for all modules or for a specified module. To use this subcommand, you must have CMC Login User privilege. • • racadm getmacaddress [-m ] [-t iscsi] [-x] racadm getmacaddress [-a] • -m — Specifies the module whose MAC address you want to view.
00:11:43:FD:B7: 00:11:43:FD:B7: 2C 2D racadm getmacaddress CMC Present N/A 00:1E:4F:1F:3C: N/A 58 Server-1 Present 00:1E:4F:2A:AF: 00:1E:4F: 7B 2A:D3:97 00:1E:4F: 2A:D3:99 Server-2 Present 00:22:19:D2:1E: N/A 84 N/A Server-3 Not Present N/A N/A N/A Server-4 Present 00:18:8B:FF: 45:2A 00:18:8B:FF:AA: 00:18:8B:FF:AA: 02 04 Server-5 Present 00:19:B9:FF:FE: 00:19:B9:FF:FC: 00:19:B9:FF:FC: E2 0C 0E Server-6 Pr
Switch-3 Present N/A 00:00:00:00:00: N/A 00 Switch-4 Present N/A 00:00:00:00:00: N/A 00 Switch-5 Present N/A 00:05:1E:08:EB: N/A 0B Switch-6 Not Present N/A N/A N/A Display Ethernet and iSCSI MACS of all LOMs/mezzanine cards.
Server-4-B Gigabit Ethernet Not Present Not Installed Not Installed iSCSI Present Not Installed Not Installed Server-4-C Fibre Channel 4 Present Not Installed Not Installed Server-5-A Gigabit Ethernet Present 00:19:B9:FF: 00:19:B9:FF: 00:19:B9:FF: FE:E2 FC:0C FC:0E iSCSI Present 00:19:B9:FF: 00:19:B9:FF: FC:0D FC:0F Gigabit Ethernet Present Not Installed Not Installed iSCSI Present Not Installed Not Installed Server-5-C Fibre Channel 4 Present Not Installed Not Installed Se
Server-13-A Gigabit Ethernet Present 00:18:8B:FF: 00:18:8B:FF: 00:18:8B:FF: 45:26 A9:F2 A9:F4 iSCSI Present 00:18:8B:FF: 00:18:8B:FF: A9:F3 A9:F5 Gigabit Ethernet Present 00:1D: 09:71:E0:78 00:1D: 09:71:E0:7A iSCSI Present 00:1D: 09:71:E0:79 00:1D: 09:71:E0:7B Server-13-C Fibre Channel 4 Present 21:00:00:1B: 21:01:00:1B: 32:0E:EF:30 32:2E:EF:30 Server-14-A Gigabit Ethernet Present 00:22:19:D2: N/A 1E:A2 N/A iSCSI Present N/A N/A Gigabit Ethernet Present Not Installed Not Insta
Switch-6 N/A Not Present N/A N/A N/A getmodinfo Description Displays configuration and status information for all modules or a specified module (server, switch, CMC, fan unit, power supply unit, KVM, or I2C cable) in the chassis. For CMC only, a power state of "Primary" denotes Active CMC. To use this subcommand, you must have CMC Login User privilege. NOTE: The service tag field is blank for modules that do not have service tags.
Switch-2 Switch-3 Switch-4 Switch-5 Switch-6 Server-1 Server-2 Server-3 Server-4 Server-5 Server-6 Server-7 Server-8 Server-9 Server-10 Server-11 Server-12 Server-13 Server-14 Server-15 Server-16 KVM IO-Cable FPC-Cable Not Present Not Present Not Present Not Present Not Present Not Present Present Present Present Present Present Present Not Present Not Present Extension(2) Not Present Present Not Present Present Present Present Present Present Present N/A N/A N/A N/A N/A N/A OFF ON ON ON ON ON N/A N/A N/A
IPv4 settings: NIC Enabled = 1 IPv4 Enabled = 1 DHCP Enabled = 1 IP Address = 10.35.0.64 Subnet Mask = 255.255.255.0 Gateway = 10.35.0.
getpbinfo Description Displays power budget status information. To use this subcommand, you must have CMC Login User privilege.
9 10 11 12 13 14 15 16 SLOT-09 SLOT-10 SLOT-11 SLOT-12 SLOT-13 SLOT-14 SLOT-15 SLOT-16 N/A Extension(2) N/A ON N/A ON ON ON N/A N/A N/A 125 N/A 342 140 125 W W W W 5 5 5 5 5 5 5 5 N/A N/A N/A PowerEdgeM600 N/A N/A N/A getpminfo Description Displays power management status information. To use this subcommand, you must have CMC Login User privilege.
Performance = 7000 W (6130 BTU/hr) Redundancy Policy = None Dynamic PSU Engagement Enabled = No [Power Budgeting] System Input Max Power Capacity = 0 W Input Redundancy Reserve = 0 W Input Power Allocated to Servers = 0 W Input Power Allocated to Chassis Infrastructure = 51W Total Input Power Available for Allocation = 0 W Standby Input Power Capacity = 0 W getraclog Description The getraclog command displays RAC or CMC log entries.
Message Arg 2 = 10.92.68.245 FQDD = iDRAC.Embedded.1 Example • Display the starting record and the number of records. racadm getraclog -s 10 -c 2 • Display a few records and prompt to display another set of records. $ racadm getraclog --more Dec 4 22:23:09 CMC-JP4BF2S Login success from 10.94.46.52 (username=root, type=SSH, sid=16393) Dec 4 22:24:54 CMC-JP4BF2S Login success from 10.94.46.52 (username=test, type=SSH, sid=35885) Dec 4 22:26:20 CMC-JP4BF2S Login success from 10.94.46.
getredundancymode Description Displays the redundancy status (Redundant or NonRedundant) of the CMC. To use this subcommand, you must have CMC Login User privilege. Synopsis racadm getredundancymode Example racadm getredundancymode Redundant getsel Description Synopsis Displays all sensor event log entries in the DRAC. • • racadm getsel -i [-A] racadm getsel [-s ] [-c ] [-A] [-o] [-E] [-R] [--more] If no arguments are specified, the entire log is displayed.
For CMC: racadm getsensorinfo FanSpeed 1 Fan-1 OK 4768 FanSpeed 2 Fan-2 OK 4873 FanSpeed 3 Fan-3 OK 4832 FanSpeed 4 Fan-4 OK 4704 FanSpeed 5 Fan-5 OK 4833 FanSpeed 6 Fan-6 OK 4829 FanSpeed 7 Fan-7 OK 4719 FanSpeed 8 Fan-8 Not OK 1 FanSpeed 9 Fan-9 OK 4815 rpm rpm rpm rpm rpm rpm rpm rpm rpm 2344 2344 2344 2344 2344 2344 2344 2344 2344 14500 14500 14500 14500 14500 14500 14500 14500 14500
System Board Fan6B RPM System Board Fan7B RPM Ok Ok 5160 RPM 3840 RPM Sensor Type : VOLTAGE CPU1 VCORE PG System Board 3.3V PG System Board 5V PG CPU1 PLL PG System Board 1.1V PG CPU1 M23 VDDQ PG CPU1 M23 VTT PG System Board FETDRV PG CPU1 VSA PG CPU1 M01 VDDQ PG System Board NDC PG CPU1 VTT PG System Board 1.
System Board CMOS Battery Ok Present Sensor Type : PERFOMANCE System Board Power Optimized Ok Not Degraded Sensor Type : INTRUSION System Board Intrusion Closed Sensor Type : REDUNDANCY System Board Fan Redundancy System Board PS Redundancy Full Redundant Disabled Sensor Type : SD CARD vFlash Active NA NA NA NA Power ON Fan PSU getslotname Description Displays the n
11 12 13 14 15 16 SLOT-11 SLOT-12 SLOT-13 SLOT-14 SLOT-15 SLOT-16 racadm getslotname -i 1 Webserver-1 getssninfo Description Displays a list of users that are connected to iDRAC.
Example racadm getsvctag getsysinfo Description Displays information related to iDRAC, managed system, and watchdog configuration. NOTE: The local racadm getsysinfo subcommand on Linux displays the PrefixLength on separate lines for IPv6 Address 2 – IPv6 Address 15 and the Link Local Address. NOTE: The Hostname and OS Name fields in the getsysinfo output display accurate information only if Dell OpenManage Server Administrator is installed on the managed system.
Current IP Gateway Autoconfig = :: = 1 Link Local Current IP Current IP Current IP Current IP Current IP Current IP Current IP Current IP Current IP Current IP Current IP Current IP Current IP Current IP = = = = = = = = = = = = = = = IP Address Address 2 Address 3 Address 4 Address 5 Address 6 Address 7 Address 8 Address 9 Address 10 Address 11 Address 12 Address 13 Address 14 Address 15 fe80::224:e8ff:fe2e:c5d3/255 :: :: :: :: :: :: :: :: :: :: :: :: :: :: DNS Servers from DHCPv6 = 0 Current DNS Serv
System Revision System BIOS Version BMC Firmware Version Service Tag Host Name OS Name Power Status = = = = = = = I 0.2.3 0.17 48192 racdev103 Microsoft Windows Server 2003 OFF Watchdog Information: Recovery Action Present countdown value Initial countdown value = None = 0 seconds = 0 seconds gettracelog Description Synopsis Input Lists all the trace log entries in iDRAC and CMC.
Input • • (none) - Displays the version information for all targets or devices. -m - Specifies the module or device for which you want to retrieve the version information. is one of the following: – – • • • • server-nx where n=1-8 ; x = a,b,c,d cmc-n where n= 1 or 2. For example, cmc-2. -c - Displays the server's current CPLD version. -b - Displays the server's current BIOS version (default is iDRAC version). -l - Displays the firmware versions of available server components.
server-2 PowerEdgeM805 server-5 1.0.0 PowerEdgeM710 server-1 2.0.0 PowerEdgeM605 server-2 1.1.0 PowerEdgeM805 server-5 1.1.0 PowerEdgeM710 racadm getversion -b racadm getversion -l -m server-1 server-1 BIOS 1.2.1 2010-11-22 iDRAC 3.20 2010-11-22 USC 1.5.0.667 2011-02-05 Diagnostics 5144A0 2011-02-07 OS Drivers 6.3.0.15 2010-11-22 Broadcom 5709 Emb(nic-1) 5.2.
hwinventory Description Synopsis Allows you to display or export current internal hardware inventory or shipped hardware inventory by device. To use this subcommand, you must have login privilege. This subcommand is applicable for iDRAC only.
Sync Time: Product Name: Permanent MAC Address: WWPN: Family Version: Controller BIOS Version: EFI Version: Max Bandwidth: Min Bandwidth: Current Commit Index: FCoE WWNN: Vendor Name: Ports Count: Number PCIE Functions Supported: Number PCIE Functions Enabled: Link Duplex: Link Speed: Auto Negotiation: Transmit Flow Control: Receive Flow Control: Media Type: Status Flag: Nic Mode: FCoE Offload Mode: iScsi Offload Mode: reserved: 0x0000 QLogic CNA Gigabit Ethernet-B8:AC:6F:B3:BF:1 B8:AC:6F:B3:BF:11 ½.
Hard Zone Address: Hard Zone Enable: FC Tape Enable: Loop reset Delay: Frame Payload Size : Fabric Login Retry Count: Fabric Login Timeout: Port Login Retry Count: Port Login Timeout: Port Down Retry Count: Port Down Timeout: Link Down Timeout: Port Number: Port Speed: No capabilities found for FQDD "FC.Slot.2-1" /admin1-> racadm hwinventory FC.Slot.
ifconfig Description Displays the contents of the network interface table. To use this subcommand for CMC, you must have Administrator privilege and for iDRAC, you must have Execute Diagnostic Commands permission. Synopsis racadm ifconfig Example $ racadm ifconfig eth0 Link encap:Ethernet HWaddr 00:1D:09:FF:DA:23 inet addr:10.35.155.136 Mask:255.255.255.0 Metric:1 overruns:0 frame:0 carrier:0 Bcast:10.35.155.
NOTE: Export to an IPv6 NFS share is not supported. • -t - Specifies the file type to be exported. Valid values are xml and csv. These are case-insensitive. NOTE: From firmware racadm, only export to a remote share is supported. The behavior of remote share is not defined when the path specified (-l) contains special characters. Example • Export the log to a remote CIFS share: racadm inlettemphistory export -f Mylog.xml -u admin p mypass -l //1.2.3.
where valid options are -i and –all. racadm jobqueue create [-r ] [-s ] [-e ] Input • • • • • • Example -i — Specifies a JobID that can be displayed or deleted. --all — The JobIDs which are not applied will be deleted. -fqdd — Specifies a FQDD for which a job has to be created. —r — Specifies a reboot type. – none — No Reboot Job. This is the default value. – pwrcycle — PowerCycle. – graceful — Graceful Reboot without forced shutdown.
Example racadm krbkeytabupload -f c:\keytab \krbkeytab.tab lclog Description Allows you to export the lifecycle log history, view the lifecycle log for a particular device or category, add comment to a record in lifecycle log, and add a worknote(an entry) in the lifecycle log. To use this subcommand, you must have Configure iDRAC permission. This subcommand is applicable for iDRAC only. NOTE: On Local RACADM, when you run this command, the data is exposed to RACADM as a USB partition.
• • • • • • • NOTE: This parameter input is an integer. If an alphanumeric input is provided, then invalid subcommand syntax error is displayed. -n — Specifies the n Number of records to be displayed. On Local RACADM, if this parameter is not specified, by default 100 logs are retrieved. -r — Displays events that have occurred after this time. The time format is yyyymm-dd HH:MM:SS. The time stamp must be provided within double quotes. -e — Displays events that have occurred before this time.
NOTE: To view or export the lifecycle log you need Login to iDRAC permission only.
Input • racadm license delete -c • racadm license replace -t 1 • racadm license replace -u -p -f -l -t • • • • • • view — View license information. import — Installs a new license. export — Exports a license file. delete — Deletes a license from the system. replace — Replaces an older license with the given license file.
Examples • View All License Information on System $racadm license view iDRAC.Embedded.1 Status = OK Device = iDRAC.Embedded.1 Device Description = iDRAC Unique Identifier = License #1 Status = OK Transaction ID = 2 License Description Enterprise Evaluation License = iDRAC License Type = EVALUATION Entitlement ID = mDmiPm4dVTPFMB34r2axrNwL Expiration = 2011-11-04T22:00:00 • Import a new license to a specific device in a known location $racadm license import -f license.
• Export license to a CIFS share specifying the entitlement ID, in this case abcdxyz : racadm license export -u admin -p passwd -f License.xml -l //192.168.2.140/licshare -e abcdxyz • Export license to a CIFS share specifying the FQDD. While using the -c option and exporting license(s) from a device, more than one license file may be exported. Therefore if a file name is given, an index is appended to the end of the file name such as LicenseFile0.xml, LicenseFile1.xml and so on.
ff00::/8 :: U 256 0 0 eth1 Kernel IP routing table Destination Gateway Genmask Flags MSS Window irtt Iface 10.94.161.0 0.0.0.0 255.255.255.0 U 0 0 0 bond0 0.0.0.0 10.94.161.1 0.0.0.0 UG 0 0 0 bond0 Active Internet connections (w/o servers) Proto Recv-Q Send-Q Local Address Foreign Address State tcp 0 0 127.0.0.1:8195 127.0.0.1:52887 ESTABLISHED tcp 0 0 127.0.0.1:199 127.0.0.1:52174 ESTABLISHED tcp 0 0 127.0.0.1:52175 127.0.0.1:199 ESTABLISHED tcp 0 0 127.0.0.1:199 127.0.0.1:52175 ESTABLISHED tcp 0 0 10.
• Displays the statistics for the integrated NIC. $ racadm nicstatistics NIC.Integrated.1-1 Total Bytes Received:0 • Total Bytes Transmitted: 0 Total Unicast Bytes Received: 0 Total Multicast Bytes Received: 0 Total Broadcast Bytes Received: 0 Total Unicast Bytes Transmitted: 0 Get the network statistics $ racadm nicstatistics NIC.Slot.5-2-1 : QLogic CNA Gigabit Ethernet-B8:AC:6F:B3:BF:10 NIC.Slot.5-2-1 : QLogic CNA Gigabit Ethernet-B8:AC:6F:B3:BF:11 NIC.Slot.
Reply from 2011:de11:bdc:194::31: time<1ms Reply from 2011:de11:bdc:194::31: time<1ms Ping statistics for 2011:de11:bdc:194::31: Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 0ms, Maximum = 0ms, Average = 0ms racdump Description Provides a single command to get dump, status, and general iDRAC board information.
Example racadm racdump =============================================================================== General System/RAC Information =============================================================================== CMC Information: CMC Date/Time Active CMC Version Standby CMC Version Last Firmware Update Hardware Version Current IP Address Current IP Gateway Current IP Netmask DHCP Enabled MAC Address Current DNS Server 1 Current DNS Server 2 DNS Servers from DHCP Register DNS CMC Name DNS CMC Name Current D
PWR 1 PWR 2 PWR 3 PWR 4 PWR 5 PWR 6 PS-1 PS-2 PS-3 PS-4 PS-5 PS-6 Online OK Online OK Online OK Slot Empty N/A Failed OK Slot Empty N/A racreset Description Resets iDRAC . The reset event is logged in the iDRAC log. Resets CMC. The reset event is logged in the hardware (sel) and CMC (RAC) logs. To use this subcommand for CMC, you must have Chassis Administrator privilege and for blade servers, you need the server administrator privilege.
• To reset CMC: racadm racreset • To reset server 1: racadm racreset -m server-1 • To reset servers 1 and 3: racadm racreset -m server-1 server-3 • To force reset iDRAC on servers 1 and 5: racadm racreset -m server-1 server-5 -f NOTE: The command will force reset iDRAC on both the servers. racresetcfg Description Deletes your current iDRAC or CMC configuration and resets iDRAC or CMC to the factory default settings.
iDRAC only options: Example • -f — Force resetcfg. If any VFlash partition creation or formatting is in progress when this command is issued, iDRAC sends back a warning message indicating the same. You can perform a force reset using this option. • Reset the configuration on iDRAC: racadm racresetcfg • • • The RAC configuration has initiated restoration to factory defaults. Please wait up to a minute for this process to complete before accessing the RAC again.
• Monitor and Inventory all batteries connected to the controller racadm raid get batteries --refkey The above command displays all battery keys connected to the controllers referred as refkeys. racadm raid get batteries --refkey -o The above command is an optimized version and displays all battery objects for the controller FQDD.
The above command displays all fan keys connected to the enclosures referred as refkeys. racadm raid get fans --refkey -o optimized version. The above command displays all fan objects for the enclosure FQDD. racadm raid get fans --refkey -o -p optimized and filtered version.
Input • • • • • • -c- Connect the image. -d - Disconnect image. -u - Username to access the network share. -p- Password to access the network share. -l - Image location on the network share; use double quotes around the location. -s- Display current status; –a is assumed if not specified. CMC Only options: • Example • -e — Deploys a remote image. This means that the first boot device is set to the shared image and the server is set to reboot.
serveraction Description Enables you to perform power management operations on the host system. To use this subcommand, you must have Execute Server Control Commands permission. Synopsis racadm serveraction Input • • • • -m server-nx where n=1-8 ; x = a,b,c,d -a - Performs action on all servers. Not allowed with the powerstatus action. -f - Force the action. Required for the reseat action. - Specifies the action.
• Server power operation successful Explanation of Support iDRAC Needs to support graceful shutdown The support of address individual blades is expected on the CMC set Description Use this command to set the value of configuration objects on a device and modify the RAC object values. This subcommand is applicable for iDRAC only. NOTE: For configuration of staged objects such as BIOS or NIC, commit and reboot job creation should be used to apply the pending values.
Example • Failure message indicating reason for failure. • Configure the iDRAC using a file: $ racadm set -f myrac.cfg • Configure LCD String: $ racadm set system.lcd.LCDUserString test Object value modified successfully • Configure rack name for server: $ racadm set system.location.rack.name rack1 • Configure a RAC from an XML configuration file located on a remote CIFS share: $ racadm set -f myfile.xml -t xml -u myuser -p mypass l //10.1.2.
NOTE: If —eis 0, then admin password is mandatory. • • • • • — Name of the group for administrative purpose. You can use up to 64 alphanumeric characters and hyphens and the first character must be a letter or a number. — Group IP and Network address for the group. The group IP address is used for administrative and host access to volumes. — Group Membership Management Password is required when adding members to the group.
• racadm setassettag 783839–33 The asset tag was changed successfully. setchassisname Description Sets the name of the chassis in the LCD. To use this subcommand, you must have Administrator privilege. Synopsis racadm setchassisname NOTE: Chassisname is a maximum of 64 nonextended ASCII characters. Example racadm setchassisname dellchassis-1 The chassis name was set successfully. setflexaddr Description Enables/disables FlexAddress on a particular slot/fabric.
setled Description Sets the state (blinking or not blinking) of the LED on the specified module. To blink or unblink the chassis, I/O modules or the CMC, you must have Debug Administrator privilege on CMC. To enable the servers to blink or unblink, you must have Server Administrator or Debug Administrator privilege on CMC. To use this subcommand for iDRAC, you must have Configure iDRAC permission.
setniccfg Description Sets the iDRAC IP address. It displays an error message if the requested operation could not be performed, or a success message if the operation is completed successfully. To use this subcommand, you must have Configure iDRAC permission. NOTE: The terms NIC and Ethernet management port may be used interchangeably.
— mm is the month — dd is the day — hh is the hour — mm is the minutes — ss is the seconds — mmmmmm is the number of microseconds — s is a + (plus) sign or a - (minus) sign, which indicates the sign of the offset — off is the offset in minutes NOTE: The off is the offset in minutes from GMT and must be in 15-minute increments. The timezone is represented as an offset from GMT, and the clock does not automatically adjust to daylight savings time (for '-d' option).
setslotname Description Displays the name and hostname (if available) of all 16 slots, or of a specified slot (indicated by the slot number) in the chassis. Optionally, this command can be used to set whether the slot name or hostname is displayed in the CMC User Interface or with the getslotname -i command. If the hostname is not available, the static slot name is used. To use this subcommand, you must have Administrator privilege.
• Example -c — Sets the chassis name or location. racadm setsysinfo -c chassisname "Dell Rack System" The chassis name was set successfully. sshpkauth Description Enables you to upload and manage up to 4 different SSH public keys per user. You can upload a key file or key text, view keys, or delete keys. This command has three mutually exclusive modes— upload, view, and delete that are determined by the options.
• • • • options. must be between 1 to 4 or all on iDRAC. -t - Key text for the SSH Public key. -f - File containing the key text to upload. The -f option is not supported on Telnet/ssh/serial RACADM. -v - View the key text for the index provided. -d - Delete the key for the index provided.
2 = CA certificate for Directory Service 3 = Custom signing certificate Output Returns 0 when successful and a nonzero number when unsuccessful. Example racadm sslcertdownload -t 1 -f c:\cert \cert.txt NOTE: This command is not supported in the firmware racadm interface as is not a file system. sslcertupload Description Uploads a custom SSL server or CA certificate for Directory Service from the client to iDRAC or CMC. To use this subcommand, you must have Configure iDRAC permission.
• Uploading a PKCS file without any passphrase: racadm sslcertupload –t 3 –f • Uploading a PKCS file with a passphrase: racadm sslcertupload –t 3 –f –p sslcertview Description Displays the SSL server or CA certificate that exists on iDRAC. To use this subcommand, you must have iDRAC Login Privilege. Synopsis racadm sslcertview -t [-A] Input • • -t - Specifies the type of certificate to view, either the CA certificate or server certificate.
Organizational Unit (OU) Remote Access Group Common Name (CN) iDRAC Default certificate Common Name (CN) iDRAC Default certificate Valid From Jul 8 16:21:56 2005 GMT Valid To Jul 7 16:21:56 2010 GMT racadm sslcertview -t 1 -A 00 US Texas Round Rock Dell Inc. Remote Access Group iDRAC default certificate US Texas Round Rock Dell Inc.
sslcsrgen Description Generates and downloads a CSR file to the client’s local file system. The CSR can be used for creating a custom SSL certificate that can be used for SSL transactions on iDRAC. To use this subcommand, you must have Configure iDRAC permission. Synopsis racadm sslcsrgen [-g] [-f ] racadm sslcsrgen -s Input • • • -g — Generates a new CSR. -s — Returns the status of a CSR generation process (generation in progress, active, or none).
• 1 = SSL key used to generate the server certificate -f — Specifies the file name of the SSL key to be uploaded. Output Returns 0 when successful and a nonzero number when unsuccessful. Example racadm sslkeyupload -t 1 -f c: \sslkey.txt sslresetcfg Description Restores the web-server certificate to factory default and restarts web-server. The certificate takes effect 30 seconds after the command is entered.
• • • • • • -l — Network share location, can be either CIFS or NFS. -f — Image file name. -u — Username for the remote share access. -p — Password for the remote share access. --vFlash — Choose vFlash SD as target location for Backup.
• Enable the alert — racadm config -g cfgEmailAlert -o cfgEmailAlertEnable -i 1 • Set the destination e-mail address — racadm config -g cfgEmailAlert -o cfgEmailAlertAddress -i 1 user1@mycompany.com • Set the custom message that is sent to the destination e-mail address — racadm config -g cfgEmailAlert -o cfgEmailAlertCustomMsg -i 1 "This is a test!" • Make sure that the SMTP IP address is configured properly — racadm config -g cfgRemoteHosts -o cfgRhostsSmtpServerIpAddr 192.168.0.
This subcommand when executed performs the following: • • • • • • • Checks command syntax. Verifies whether the required system resources are available. Validates Active Directory configuration. Verifies the SSL certificate and if the certificate signing request (key) exists. Acquires LDAP and Global Catalog Service records from DNS. Acquires user privileges from the Active Directory server. Checks the time to acquire user privileges with the allotted time to login.
• • Verifies that the CMC acquires a Kerberos TGT. Acquires user privileges from the Active Directory server. Checks the time to acquire user privileges with the allotted time to login. • NOTE: In the event of an error, the command outputs all tests performed up to and including the test that failed, as well as all error messages.
• View the current test trap settings racadm getconfig -g cfgIpmiPet -i where is a number from 1 to 4 testalert Description Tests FQDN supported SNMP trap notifications. To use this subcommand, you must have Test Alert User Access . This subcommand is applicable only for iDRAC. Synopsis racadm testalert -i Input -i — Specifies the index of the trap test. index must be an integer from 1 to 8 on iDRAC.
To use this subcommand for CMC, you must have Administrator privilege and for iDRAC, you must have Execute Diagnostic Commands permission. Synopsis racadm traceroute6 racadm traceroute fd01::1 Output traceroute to fd01::1 (fd01::1) from fd01::3, 30 hops max, 16 byte packets 1 fd01::1 (fd01::1) 14.324 ms 0.26 ms 0.244 ms update Description Allows you to update the platforms for devices on the servers. The supported firmware image file types are: • • • • Synopsis .
To use this subcommand, you must have Configure iDRAC permission. This option is applicable only to iDRAC. Synopsis Input racadm usercertupload -t [-f ] -i • • • -t — Specifies the type of certificate to upload, either the CA certificate or server certificate. — 1 = user certificate — 2 = user CA certificate -f - Specifies the file name of the certificate to be uploaded. If the file is not specified, the sslcert file in the current directory is selected.
• racadm vflashsd status vflashpartition Description Manages the partitions on the vFlash SD card. NOTE: To use this subcommand, you must have the iDRAC7 Enterprise license. Synopsis Input racadm vflashpartition i -o
• Status of all existing partitions: racadm vflashpartition status -a • List all the existing partitions and its properties: racadm vflashpartition list vmdisconnect Description Allows you to disconnect another Virtual Media session. Once disconnected, the Web-based interface reflects the correct connection status. Enables an iDRAC user to disconnect all active Virtual Media sessions.
iDRAC and CMC Property Database Group and Object Descriptions 3 The iDRAC and CMC property database contains the configuration information for iDRAC and CMC. Data is organized by associated object, and objects are organized by object group. The IDs for the groups and objects that the property database supports are listed in this section for iDRAC Enterprise on Blade Servers, iDRAC Enterprise or Express on Rack and Tower Servers and CMC.
Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower Servers CMC ifcRacManagedNodeOs Yes Yes No cfgRacSecurity No No Yes cfgRacVirtual Yes Yes No cfgServerInfo No Yes Yes cfgActiveDirectory Yes Yes Yes cfgLDAP Yes Yes Yes cfgLdapRoleGroup Yes Yes Yes cfgStandardSchema Yes Yes Yes cfgChassisPower No No Yes cfgIpmiSol Yes Yes No cfgIpmiLan Yes Yes No cfgIpmiPetIpv6 Yes Yes No cfgIpmiPef Yes Yes No cfgIpmiPet Yes Yes No cfgUserDomain Yes Yes N
idRacInfo This group contains display parameters to provide information about the specifics of iDRAC or CMC being queried. One instance of the group is allowed. For CMC, use this object with the getconfig subcommand. To use this object for CMC, you must have CMC Login User privilege. The following sections provide information about the objects in the idRACInfo group. idRacProductInfo (Read Only) Description A text string that identifies the product. Legal Values A string of up to 63 ASCII characters.
Default for CMC CMC iDRAC Type (Read Only) Description Identifies the remote access controller type.
cfgNicIPv4Enable (Read or Write) Description Enables or disables iDRAC or CMC IPv4 stack. Legal Values • • Default 1 (TRUE) 0 (FALSE) 0 cfgNicSelection (Read or Write) Description Specifies the current mode of operation for the RAC network interface controller (NIC). The table below describes the supported modes. This object is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers or CMC.
NOTE: For iDRAC Enterprise on Blade Servers, this object enables or disables the VLAN capabilities of iDRAC from CMC. This is Read only for iDRAC on Blade servers. iDRAC displays only the current VLAN settings and you cannot modify the settings from iDRAC. All chassis management traffic, including the CMC and all iDRACs, resides on this external VLAN when enabled. No iDRAC configuration change is required to use this external management network VLAN.
cfgDNSDomainNameFromDHCP (Read/Write) Description Specifies that iDRAC or CMC DNS domain name should be assigned from the network DHCP server. Legal Values Default • • 1 (TRUE) 0 (FALSE) 0 For CMC, this property is used only if cfgNicUseDhcp is set to 1 (true), or if both cfgIPv6Enable and cfgIPv6AutoConfig are set to 1 (true).
Default For iDRAC: idrac- For CMC: cmc- cfgDNSRegisterRac (Read/Write) Description Registers the iDRAC or CMC name on the DNS server. When you set this parameter, the CMC registers its DNS name for its IPv4 and IPv6 addresses with the DNS server. Legal Values Default • • 1 (TRUE) 0 (FALSE) 0 NOTE: For IPv6, only the DHCPv6 address or static address is registered. Example: racadm getconfig -g cfgLanNetworking cfgNicEnable=1 cfgNicIPv4Enable=1 cfgNicIpAddress=192.168.22.
cfgDNSServersFromDHCP (Read/Write) Description Specifies if the DNS server IPv4 addresses should be assigned from the DHCP server on the network. For CMC, this property is used only if cfgNicUseDhcp is set to 1 (true). Legal Values Default • • 1 (TRUE) 0 (FALSE) 0 cfgDNSServer1 (Read/Write) Description Specifies the IPv4 address for DNS server 1. This property is only valid if cfgDNSServersFromDHCP is set to 0 (FALSE).
cfgNicIpAddress (Read/Write) Description Specifies the static IPv4 address to be assigned to the RAC or CMC. NOTE: This parameter is only configurable if the cfgNicUseDhcp parameter is set to 0(FALSE.) Legal Values String representing a valid IPv4 address. For example: 192.168.0.20. Default • • • For iDRAC on Rack and Tower Servers: 192.168.0.120 For iDRAC Enterprise on Blade Servers: 192.168.0.n, where n is 120 plus the server slot number. For CMC: 192.168.0.
cfgNicUseDhcp (Read/Write) Description Specifies whether DHCP is used to assign the iDRAC or CMC IPv4 address. If this property is set to 1 (TRUE), then iDRAC or CMC IPv4 address, subnet mask, and gateway are assigned from the DHCP server on the network. If this property is set to 0 (FALSE), the user can configure the cfgNicIpAddress, cfgNicNetmask, and cfgNicGateway properties.
cfgNicStaticIPv4Enable (Read or Write) Description Legal Values Default Enables or disables the IPv4 stack. • • 0 — Disabled 1 — Enabled 1 — Enabled NOTE: If this object is modified, then the object cfgNicIPv4Enable is also modified. cfgNicStaticIpAddress (Read or Write) Description Returns or sets the current IPv4 address. NOTE: Only sets the current IPv4 address if cfgNicUseDhcp is set to 0 (false). Legal Values Any Valid IPv4 address Default 192.168.0.
cfgNicStaticGateway (Read or Write) Description Returns or sets the static IPv4 address. Legal Values Any Valid IPv4 address Default 192.168.0.120 cfgDNSStaticServersFromDHCP (Read or Write) Description Specifies the DNS server static IP addresses. Legal Values Default • • DNS Addresses are configured on the Device DNS Addresses are assigned via DHCP 0 cfgDNSStaticServer1 (Read or Write) Description Specifies the IP address for DNS server 1.
NOTE: Microsoft Active Directory only supports Fully Qualified Domain Names (FQDN) of 64 characters or fewer length. Default Null cfgDNSStaticDomainNameFromDHCP (Read or Write) Description Specifies the device DNS static domain name. Legal Values Default • • 0 — Do not use DHCP to get the Domain Name 1 — Use DHCP to get the Domain Name 0 — Disabled cfgRemoteHosts This group provides properties that allow configuration of the SMTP server for e-mail alerts.
cfgRhostsFwUpdatePath (Read/Write) Description Specifies TFTP path where iDRAC or CMC firmware image file exists on the TFTP server. The TFTP path is relative to the TFTP root path on the TFTP server. NOTE: The server may still require you to specify the drive (for example, C:). Legal Values A string with a maximum length of 255 ASCII characters. Default cfgRhostsSmtpServerIpAddr (Read/Write) Description The IPv4 or IPv6 address of the network SMTP server.
This object is applicable only for CMC. Legal Values A string representing a valid NTP server. For example, ntp2.ntp.net. At least one NTP server must be specified and duplicate entries are not allowed. Default Null cfgRhostsNtpServer3 Description Specifies the third of three possible NTP servers. This object is applicable only for CMC. Legal Values A string representing a valid NTP server. For example, ntp3.ntp.net. At least one NTP server must be specified and duplicate entries are not allowed.
cfgRhostsSyslogServer1 (Read/Write) Description Specifies the first of three possible remote syslog servers to store the RAC and SEL logs.This property is only valid if cfgRhostsSyslogEnable is set to 1 (enabled). Legal Values Default • • For iDRAC: String from 0 to 63 characters. For CMC: Valid hostname or IPv4 or IPv6 address. cfgRhostsSyslogServer2 (Read/Write) Description Specifies the second of three possible remote syslog servers to store the RAC and SEL logs..
cfgRhostsSyslogPowerLoggingInterval Description Specifies the power consumption collection/logging interval. This object is applicable only for CMC. NOTE: This object is applicable only for CMC. Legal Values 1 - 1440 (minutes) Default 5 Example racadm getconfig -g cfgRemoteHosts [-m server-] cfgRhostsFwUpdateTftpEnable=1 cfgRhostsFwUpdateIpAddr=0.0.0.0 cfgRhostsFwUpdatePath= cfgRhostsSmtpServerIpAddr=localhost.
For CMC, the index number is used to specify a unique group name. Only valid for indexed groups. Legal Values • • For iDRAC: This parameter is populated based on the existing instances. For CMC: The parameter is specified by a decimal integer from 1–16. Default cfgUserAdminIpmiLanPrivilege (Read/Write) Description The maximum privilege on the IPMI LAN channel. This object property is specific to iDRAC.
Clear Logs 0x00000008 Execute Server Control Commands 0x00000010 Access Virtual Console 0x00000020 Access Virtual Media 0x00000040 Test Alerts 0x00000080 Execute Debug Commands 0x00000100 CMC Specific User Privilege CMC Login User 0x0000001 Chassis Configuration Administrator 0x0000002 User Configuration Administrator 0x0000004 Clear Logs Administrator 0x0000008 Chassis Control Administrator 0x0000010 Super User 0x0000020 Server Administrator 0x0000040 Test Alert User 0x0000080 D
cfgUserAdminUserName (Read/Write) Description The name of the user for this index. The user index is created by writing a string into this name field if the index is empty. Writing a string of double quotes ("") deletes the user at that index. You cannot change the name. You must delete and then recreate the name. The string cannot contain / (forward slash), \ (backslash), . (period), @ (at symbol) or quotation marks. NOTE: This property value must be unique among user names.
Default 0 cfgUserAdminIpmiSerialPrivilege (Read/Write) Description The maximum privilege on the IPMI LAN channel. This object is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers or CMC. Legal Values Default • • • • 2 (User) 3 (Operator) 4 (Administrator) 15 (No access) • • 4 (User 2) 15 (All others) cfgEmailAlert This group contains parameters to configure iDRAC or CMC e-mail alerting capabilities. Up to four instances of this group are allowed.
cfgEmailAlertAddress (Read/Write) Description Specifies the destination email address for email alerts, for example, user1@company.com. Legal Values E-mail address format, with a maximum length of 64 ASCII characters. Default cfgEmailAlertCustomMsg (Read/Write) Description Specifies a custom message that forms the subject of the alert. This object property is specific to iDRAC.
cfgSsnMgtRacadmTimeout (Read/Write) Description Defines the idle timeout in seconds for the Remote RACADM interface. If a remote RACADM session remains inactive for more than the specified sessions, the session closes.
After the message is displayed, the system returns to the shell that generated the Secure Shell session. Legal Values • • 0 (No timeout) 60 – 10800 NOTE: If 0 (no timeout), the network connection does not send keep alive packets to probe the client. Otherwise, keep alive packets are sent to guarantee that the client is responding.
cfgSerialBaudRate (Read/Write) Description Sets the baud rate on iDRAC or CMC serial port. Legal Values Default • • For iDRAC: 9600, 28800, 57600, 115200 For CMC: 2400, 4800, 9600, 19200, 28800, 38400, 57600,115200 • • For iDRAC: 57600 For CMC: 115200 cfgSerialConsoleEnable (Read/Write) Description Legal Values Default Enables or disables the RAC or CMC serial console interface.
Configuration options: The value must start with the ^ character, and be followed by one of the characters— a-z, A-Z, [, ], \ Legal value: String of up to 4 characters Default: • • For iDRAC: <\> For CMC: ^\ NOTE: For information on using RACADM commands for special characters, see Guidelines to Quote Strings Containing Special Characters cfgSerialConsoleIdleTimeout (Read/Write) Description The maximum number of seconds to wait before an idle serial session is disconnected.
NOTE: The prompt counts as two characters. NOTE: The terminal emulator must be configured with the line wrap mode ON, if a terminal emulator is used. Legal Values 0 – 256 Default 0 (equivalent to 80) cfgSerialHistorySize (Read/Write) Description Specifies the maximum size of the serial history buffer. Legal Values 0 – 8192 Default 8192 cfgSerialCom2RedirEnable (Read/Write) Description Enables or disables the console for COM 2 port redirection.
cfgSerialTelnetEnable (Read/Write) Description Enables or disables the Telnet console interface on iDRAC or CMC. Legal Values Default • • 1 (TRUE) 0 (FALSE) 0 cfgOobSnmp This group contains parameters to configure the SNMP agent and trap capabilities of iDRAC or CMC. One instance of the group is allowed. The CMC SNMP agent supports the standard RFC1213 mib-2, and the Dell enterprise-specific MIB. This group is not applicable for iDRAC on Rack and Tower Servers.
cfgTraps This group displays information for and configures delivery of SNMP traps for a specific user. This object property is applicable only to CMC. Use this object with the config or getconfig subcommands. To use this object property, you must have Chassis Configuration Administrator privilege. NOTE: You can configure any setting that is not preceded by the hash sign (#) in the output. To modify a configurable object, use the -o option.
cfgTrapsAlertDestIpAddr= cfgTrapsCommunityName=public cfgRacTuning This group is used to configure various iDRAC or CMC configuration properties, such as valid ports and security port restrictions. Use this object with the config or getconfig subcommands. To use this object property for CMC, you must have Chassis Configuration Administrator privilege. NOTE: For CMC, you can configure any setting that is not preceded by the hash sign (#) in the output. To modify a configurable object, use the -o option.
cfgRacTuneHttpPort (Read/Write) Description Specifies the port number to use for HTTP network communication with iDRAC or CMC. Legal Values 10 – 65535 NOTE: For CMC, the following port numbers are reserved and cannot be used: 21, 68, 69, 123, 161, 546, 801, 4096, 5988, 5989, 6900, 9000, 60106. Default 80 cfgRacTuneHttpsPort (Read/Write) Description Specifies the port number to use for HTTPS network communication with iDRAC or CMC.
Default 192.168.1.1 cfgRacTuneIpRangeMask (Read/Write) Description Standard IP mask values with left-justified bits. For example, 255.255.255.0. For CMC, a login from the incoming IP address is allowed only if both of the following are identical: • • cfgRacTuneIpRangeMask bit-wise and with incoming IP address cfgRacTuneIpRanbeMask bit-wise and with cfgRacTuneIpRangeAddr Legal Values An IPv4 address formatted string, for example, 255.255.255.0. Default 255.255.255.
cfgRacTuneIpBlkPenaltyTime (Read/Write) Description Defines the time span in seconds that session requests from an IP address with excessive failures are rejected. Legal Values Default • • For iDRAC: 10 – 655356 For CMC: 2 – 655356 300 cfgRacTuneSshPort (Read/Write) Description Specifies the port number used for iDRAC or CMC SSH interface.
This object property is applicable only to iDRAC. Legal Values • • Default 1 (TRUE) 0 (FALSE) 1 cfgRacTuneAsrEnable (Read/Write) Description Enables or disables iDRAC last crash screen capture feature. This object property is applicable only to iDRAC and requires an iDRAC reset before it becomes active. Legal Values • • Default 1 (TRUE) 0 (FALSE) 0 cfgRacTuneDaylightOffset (Read Only) Description Specifies the daylight savings offset (in minutes) to use for the RAC Time.
• • • –420 (MST—Mountain Standard Time) –360 (CST—Central Standard Time) –300 (EST—Eastern Standard Time) For CMC: This object property is read only. Specifies the difference in number of seconds, from the UTC/GMT. This value is negative if the current time zone is west of Greenwich.
Default 0 cfgRacTuneWebserverEnable (Read/Write) Description Enables or disables iDRAC or CMC web server. If this property is disabled, iDRAC or CMC is not accessible using client web browsers. This property has no effect on the Telnet/SSH or RACADM interfaces.
• Default 1 = Use Java Plugin 0 = Active X /Native Plugin ifcRacManagedNodeOs This group contains properties that describe the managed server operating system. One instance of the group is allowed. This object is applicable only to iDRAC. The following sections provide information about the objects in the ifcRacManagedNodeOs group. ifcRacMnOsHostname (Read Only) Description The host name of the managed server. Legal Values A string of up to 255 characters.
cfgVirtualBootOnce (Read/Write) Description Enables or disables the Virtual Media Boot Once feature of iDRAC. If this property is enabled when the host server is rebooted, this feature attempts to boot from the virtual media devices—if the appropriate media is installed in the device. Legal Values Default • • 1 (TRUE) 0 (FALSE) 0 cfgVirMediaFloppyEmulation (Read/Write) Description When set to 0, the virtual floppy drive is recognized as a removable disk by Windows operating systems.
Default 0 cfgServerInfo For iDRAC this group allows you to select the BIOS first boot device and provides the option to boot the selected device only once. For CMC, this group allows you to displays information for and configure a server in the chassis. Use this object with the config or getconfig subcommands. To use this object property for CMC, you must have Chassis Configuration Administrator privilege.
cfgServerFW (Read Only) Description Displays the server's iDRAC management firmware revision. This object is applicable only to CMC. Legal Values None Default None cfgServerBIOS (Read Only) Description Displays the server's BIOS revision. This object is applicable only to CMC. Legal Values None Default None cfgServerBmcMacAddress (Read Only) Description Displays the BMC MAC address of the specified server. This object is applicable only to CMC.
cfgServerNic3MacAddress (Read Only) Description Displays the MAC address of the server NIC 3. This object is applicable only to CMC. Legal Values None Default None cfgServerNic4MacAddress (Read Only) Description Displays the MAC address of the server NIC 4. This object is applicable only to CMC. Legal Values None Default None cfgServerPriority (Read/Write) Description Sets the priority level allotted to the server in the chassis for power budgeting purposes.
cfgServerPowerBudgetAllocation (Read Only) Description Displays the current power allocation for the server. This object is applicable only to CMC. Legal Values • • Default 1 (Enable) 0 (Disable) None cfgServerDNSRegisterIMC (Read/Write) Description Enables or disables DNS name registration for the Integrated System (iDRAC). This object is applicable only to CMC.
NOTE: For a vFlash Partition to be configured as First Boot Device, it has to be attached first.
# cfgServerBmcMacAddress=00:21:9B:FE:5F:58 # cfgServerNic1MacAddress=00:0D:56:B8:69:63 170 CMC Property Database Group and Object Definitions # cfgServerNic2MacAddress=00:0D:56:B8:69:65 # cfgServerNic3MacAddress=00:0D:56:B8:69:CB # cfgServerNic4MacAddress=00:0D:56:B8:69:CD cfgServerPriority=1 cfgServerNicEnable=1 cfgServerIPMIOverLANEnable=1 # cfgServerPowerBudgetAllocation=0 cfgServerDNSRegisterIMC=0 cfgServerDNSIMCName=iDRAC# cfgServerRootPassword=******** (Write-Only) # cfgServerFirstBootDevice=********
The following sections provide information about the objects in the cfgActiveDirectory group. cfgADRacDomain (Read/Write) Description Active Directory Domain in which iDRAC or CMC resides. Legal Values Any printable text string of up to 254 characters, with no white space. Default cfgADRacName (Read/Write) Description Name of iDRAC or CMC as recorded in the Active Directory forest. Legal Values Any printable text string of up to 254 characters, with no white space.
• Default 0 (Disable) 0 cfgADSSOEnable (Read/Write) Description Enables or disables Active Directory single sign-on authentication on iDRAC. Legal Values Default • • 1 (TRUE) 0 (FALSE) 0 cfgADDomainController Description Specifies the AD server from which you want the CMC to obtain user names. Must be used with cfgADSpecifyServerEnable. This object is applicable only to CMC. Legal Values Valid IP address or fully qualified domain name (FQDN).
This object is applicable only to iDRAC. Legal Values A string of up to 254 ASCII characters representing a valid IP address or a fully qualified domain name (FQDN). Default None cfgADAuthTimeout (Read/Write) Description Specifies the number of seconds to wait for Active Directory authentication requests to complete before timing out. NOTE: To modify this property, you must have Configure iDRAC permission.
Example racadm getconfig -g cfgActiveDirectory cfgADEnable=1 cfgADSCLEnable=0 cfgADSSOEnable=0 cfgADRacDomain= cfgADRootDomain=help cfgADRacName= cfgADRacAuthTimeout=300 cfgADType=0x4 cfgADSpecifyServerEnable=1 cfgADDomainController=192.168.1.1 cfgADGlobalCatalog=127.0.0.1 cfgADGlobalCatalog1 (Read/Write) Description Specifies the Global Catalog server from which you want the iDRAC to obtain user names. This object is applicable only to iDRAC.
• Default 0 (FALSE) 1 cfgADDcSRVLookupEnable (Read/Write) Description Configures iDRAC to use pre‑configured domain controllers or to use DNS to find the domain controller. If using pre‑configured domain controllers, then the domain controllers to use are specified under cfgAdDomainController1, cfgAdDomainController2, and cfgAdDomainController3. iDRAC does not fail over to the specified domain controllers when DNS lookup fails or none of the servers returned by the DNS lookup works.
cfgADGcSRVLookupEnable (Read/Write) Description Determines how the global catalog server is looked up. If using pre‑configured global catalog servers, then iDRAC uses the values cfgAdGlobalCatalog1, cfgAdGlobalCatalog2, and cfgAdGlobalCatalog3. This object is applicable only to iDRAC.
cfgLdapServer (Read/Write) Description Configures the address of the LDAP Server. IPv4 and IPv6 are supported. NOTE: You can specify multiple servers by separating each server with a comma. For example, example.com, sub1.example.com Legal Values String. • • Default For iDRAC: Maximum length = 1024 For CMC: Maximum length = 254 Null cfgLdapPort (Read/Write) Description Port of LDAP over SSL. Non-SSL port is not supported.
cfgLdapGroupAttribute (Read/Write) Description Specifies which LDAP attribute is used to check for group membership. This should be an attribute of the group class. If not specified, then iDRAC or CMC uses the member and unique member attributes. Legal Values String.
Default Null cfgLdapSearchFilter (Read/Write) Description A valid LDAP search filter. This is used if the user attribute cannot uniquely identify the login user within the chosen baseDN. The search filter only applies to userDN search and not the group membership search. Legal Values • • Default For iDRAC: String of maximum length = 254 characters For CMC: String of maximum length = 1024 characters (objectclass=*) Searches for all objects in tree.
This object is applicable only to CMC. Legal Values Default • • 1 (true) 0 (false) 0 cfgLDAPSRVLookupDomainName Description Configures the domain name to be used in the SRV lookup. This object is applicable only to CMC. Legal Values String of maximum length of 254 alphanumeric characters and hyphens. The string must begin with a letter. Default [null] cfgLDAPSRVLookupServiceName (Read/Write) Description Configures the service name to be used in the SRV lookup.
This object is applicable only for iDRAC. Legal Values An integer between 1 and 5 Default cfgLdapRoleGroupDN (Read/Write) Description This is the Domain Name of the group in this index. For CMC, configure the LDAP distinguished name (DN) for the role group instance. Legal Values String.
Default 0 cfgLocationRack (Read/Write) Description Indicates rack where server is located. Legal Values String of up to 128 ASCII characters Default 0 cfgLocationRackslot (Read/Write) Description Indicates slot where server is located. Legal Values Values from 1 - 255 (1 Byte) Default 0 cfgLocationDevicesize (Read Only) Description Indicates server chassis size.
Default cfgSSADRoleGroupDomain (Read/Write) Description Active Directory Domain in which the Role Group resides. Legal Values Any printable text string of up to 254 characters, with no white space. Default cfgSSADRoleGroupPrivilege (Read/Write) Description Use the bit mask numbers listed in the table below to set role-based authority privileges for a Role Group.
NOTE: You can configure any setting that is not preceded by the hash sign (#) in the output. To modify a configurable object, use the -o option. The following sections provide information about the objects in the cfgChassisPower group. cfgChassisExternalPowerManagementMode Description Allows to enable or disable External Power Management. When this mode is enabled: • • • The chassis power capacity is set to maximum value. The server power priorities are set to 1.
cfgChassisMinPower (Read Only) Description The minimum system input power consumption value (in watts) over the time since the value was last cleared. Legal Values None Default None cfgChassisMinPowerTimestamp (Read Only) Description The timestamp recorded when the minimum system power occurred. Legal Values None Default None cfgChassisPowerStatus (Read Only) Description Legal Values Default Indicates the power status of the chassis.
cfgChassisPowerCapF (Read/Write) Description Indicates the maximum power consumption limit (in watts) for the entire chassis. Use cfgChassisPowerCapF when power consumption is to be changed regardless of whether server throttling is required. This command generates an error if the value for this setting is lower than the minimum power required for the chassis configuration.
cfgChassisPowerCapFPercent (Read/Write) Description Indicates the power consumption limit as a percentage. The percentage is computed mathematically as the minimum power + (percent * (maximum power - minimum power)). Use cfgChassisPowerCapFPercent when power consumption is to be changed regardless of whether server throttling is required. Legal Values 16 - 100 Default 100 cfgChassisRedundancyPolicy (Read/Write) Description Sets the redundancy policy of the chassis.
cfgChassisMaxPowerConservationMode (Read/Write) Description Enables or disables maximum power conservation mode. When enabled, all servers are immediately reduced to their minimum power levels, and all subsequent server power allocation requests are denied. In this mode, performance of powered on servers may be degraded, and additional servers cannot be powered on, regardless of server priority.
cfgChassisInPowerServerAllocation (Read Only) Description Indicates (in watts) the cumulative power allocated to servers. There is no default as this parameter is very specific to the particular customer configuration. Legal Values None Default None cfgChassisInfrastructureInPowerAllocation (Read Only) Description Indicates the estimated cumulative DC output power consumption (in watts), determined from a field replaceable unit (FRU) on the hardware modules in the chassis.
cfgChassisPowerButtonEnable (Read/Write) Description Indicates if the chassis power button is enabled or disabled. Legal Values • • Default 0 (disabled) 1 (enabled) None cfgSystemEnergyConsumptionClear (Write Only) Description Resets energy statistics when set to 1.
cfgIpmiSol This group is applicable only for iDRAC and is used to configure the Serial Over LAN (SOL) capabilities of the system. The following sections provide information about the objects in the cfgIpmiSol group. cfgIpmiSolEnable (Read/Write) Description Enables or disables SOL. Legal Values • • Default 1 (TRUE) 0 (FALSE) 1 cfgIpmiSolBaudRate (Read/Write) Description Specifies baud rate for serial communication over LAN.
cfgIpmiSolSendThreshold (Read/Write) Description Specifies the SOL threshold limit value and the maximum number of bytes to buffer before sending an SOL data packet. Legal Values 1 – 255 Default 255 cfgIpmiLan This group is applicable only for iDRAC and is used to configure the IPMI over LAN capabilities of the system. The following sections provide information about the objects in the cfgIpmiLan group. cfgIpmiLanEnable (Read/Write) Description Enables or disables the IPMI over LAN interface.
cfgIpmiLanEncryptionKey (Read/Write) Description Specifies the IPMI encryption key. Legal Values A string of hexadecimal digits from 0 to 40 characters with no spaces. Only an even amount of digits is allowed. Default 0000000000000000000000000000000000000000 cfgIpmiLanPetCommunityName (Read/Write) Description Specifies the SNMP community name for traps. Legal Values A string of up to 18 characters.
cfgIpmiPef This group is applicable only for iDRAC and is used to configure the platform event filters available on the managed server. The event filters can be used to control policy related to actions that are triggered when critical events occur on the managed server. The following sections provide information about the objects in the cfgIpmiPef group. cfgIpmiPefName (Read Only) Description Specifies the name of the platform event filter. Legal Values A string of up to 255 characters.
cfgIpmiPet This group is applicable only for iDRAC and is used to configure platform event traps on the managed server. The following sections provide information about the objects in the cfgIpmiPet group. cfgIpmiPetIndex (Read Only) Description Unique identifier for the index corresponding to the trap. Legal Values 1-4 Default The index value of a specific platform event trap.
cfguserdomainname Description Specifies the Active Directory user domain name. Legal Values A string of up to 254 ASCII characters Default cfgServerPower This group provides several power management features. The following sections provide information about the objects in the cfgServerPower group. cfgServerPowerStatus (Read Only) Description Represents the server power state, either ON or OFF. This object is applicable only for iDRAC.
cfgServerPowerCapEnable (Read/Write) Description Enables or disables the user specified power budget threshold. This object is Read only for iDRAC Enterprise on Blade Servers. Legal Values • • Default 0 - Disables the user specified power budget threshold 1 - Enables the user specified power budget threshold 1 cfgServerMinPowerCapacity (Read Only) Description Represents the minimum server power capacity on a blade based on the current component inventory. This object is applicable only for iDRAC.
Default Maximum power consumption timestamp. cfgServerPowerConsumptionClear (Write Only) Description Clears the current recorded power statistics. This object is applicable only for iDRAC. Legal Values 1 — Clears the Power Consumption Statistics Default None cfgServerPowerCapWatts (Read/Write) Description Represents the server power threshold in Watts. This object is applicable only for iDRAC. NOTE: This value is applicable only if cfgServerPowerCapEnable is set to 1.
cfgServerPowerLastHourAvg (Read Only) Description Displays the average power value during the last hour. This object is applicable only for iDRAC. Legal Values None Default Average power value during the last hour. cfgServerPowerLastDayAvg (Read Only) Description Displays the average power value during the last day. This object is applicable only for iDRAC. Legal Values None Default Average power value during the last day.
• • • Default HH = hour MM=Minutes SS = Seconds Minimum power value during the last minute. cfgServerPowerLastHourMaxPower (Read Only) Description Displays the maximum power value during the last hour. This object is applicable only for iDRAC. Legal Values Not applicable Default Maximum power value during the last hour. cfgServerPowerLastHourMaxTime (Read Only) Description Displays the timestamp of maximum power value during the last hour. This object is applicable only for iDRAC.
where, • • • • • • • Default DD = Day of the week MM = Month Date = Date YYYY = Year HH = hour MM = Minutes SS = Seconds Minimum power value during the last day. cfgServerPowerLastDayMaxPower (Read Only) Description Displays the maximum power value during the last day. This object is applicable only for iDRAC. Legal Values Not applicable Default Maximum power value during the last day.
cfgServerPowerLastWeekMinTime (Read Only) Description Displays the timestamp of minimum power value during the last week. This object is applicable only for iDRAC. Legal Values A string of up to 32 characters.
cfgServerPowerInstHeadroom (Read Only) Description Displays the difference between the available power and the current power consumption. This object is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers. Legal Values Not applicable Default Difference between the available power and the current power consumption. cfgServerPowerPeakHeadroom (Read Only) Description Displays the difference between the available power and the peak power consumption.
where, • • • • • • • Default DD = Day of the week MM = Month Date = Date YYYY = Year HH = hour MM = Minutes SS = Seconds Timestamp of the current peak power consumption. cfgServerCumulativePowerConsumption (Read Only) Description Displays the cumulative power consumption. This object is applicable only for iDRAC. Legal Values Not applicable Default Cumulative power consumption.
cfgServerPowerPCIeAllocation (Read/Write) Description Amount of power allocated to the PCIe cards. This object is applicable for iDRAC Enterprise only for specific Blade Servers and not for iDRAC on Rack and Tower Servers or CMC. You must have Administrator privileges to modify the value for this object. Legal Values 0W: For platforms that do not support PCIe cards. 100W - 500W: For platforms that support PCIe cards. Default 0: For platforms that do not support PCIe cards.
Use this object with the config or getconfig subcommands. To use this object property, you must have Chassis Configuration Administrator privilege. cfgAlertingEnable Description Legal Values Default Enables or disables event traps on the CMC. • • 1 (true) 0 (false) None cfgAlertingFilterMask Description Sets the event filter.
cfgServerPowerSupply This group is applicable only for iDRAC and contains information related to the power supplies. The following sections provide information about the objects in the cfgServerPowerSupply group. The cfgServerPowerSupply object group is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers.
cfgServerPowerSupplyFwVer (Read Only) Description Displays the firmware version of the power supply unit, in the format x.xx.xxx. Legal Values A string up to 8 characters. Default Null cfgServerPowerSupplyCurrentDraw (Read Only) Description Displays the instantaneous current consumption in 0.1 Amps. Legal Values A string of up to 32 characters. Default 0 cfgServerPowerSupplyType Description Displays whether the power supply is AC or DC. Legal Values A string of up to 32 characters.
NOTE: This object is applicable only for CMC. Legal Values A string representing a valid IPv6 address. For example, 2001:DB8:1234:5678:9ABC:DE11:C00C:BEEF Default :: cfgIPv6Address1 (Read/Write) Description Specifies iDRAC or CMC IPv6 address. Legal Values String representing a valid IPv6 entry. Default :: cfgIPv6Gateway (Read/Write) Description iDRAC or CMC gateway IPv6 address. NOTE: For CMC, this property is used only if cfgIPv6AutoConfig is set to 0 (false.
Default • 0 (FALSE) • • For iDRAC: 0 For CMC: 1 cfgIPv6LinkLocalAddress (Read Only) Description The iDRAC IPv6 link local address. This object is applicable only for iDRAC. Legal Values Specifies a string representing a valid IPv6 entry. Default :: cfgIPv6Address2 (Read Only) Description The iDRAC IPv6 second address. This object is applicable only for iDRAC. Legal Values A string representing a valid IPv6 entry.
cfgIPv6Address6 (Read Only) Description The iDRAC IPv6 sixth address. This object is applicable only for iDRAC. Legal Values String representing a valid IPv6 entry. Default :: cfgIPv6Address7 (Read Only) Description The iDRAC IPv6 seventh address. This object is applicable only for iDRAC. Legal Values String representing a valid IPv6 entry. Default :: cfgIPv6Address8 (Read Only) Description The iDRAC IPv6 eighth address. This object is applicable only for iDRAC.
Default :: cfgIPv6Address12 (Read Only) Description The iDRAC IPv6 twelfth address. This object is applicable only for iDRAC. Legal Values String representing a valid IPv6 entry. Default :: cfgIPv6Address13 (Read Only) Description The iDRAC IPv6 thirteenth address. This object is applicable only for iDRAC. Legal Values String representing a valid IPv6 entry. Default :: cfgIPv6Address14 (Read Only) Description The iDRAC IPv6 fourteenth address. This object is applicable only for iDRAC.
cfgIPv6DNSServer1 (Read/Write) Description Specifies the IPv6 DNS server address. NOTE: This property is used only if cfgIPv6DNSServersFromDHCP6 is set to 0 (false). Legal Values A string representing a valid IPv6 entry. For example, 2001:DB8:1234:5678:9ABC:DE11:C00C:BEEF Default :: cfgIPv6DNSServer2 (Read/Write) Description Specifies the IPv6 DNS server address. NOTE: This property is only valid if cfgIPv6DNSServersFromDHCP6 is set to 0 (false).
cfgIPv6StaticEnable (Read or Write) Description Enables or disables the static IPv6 stack. Legal Values Default • • 0 — Disabled 1 — Enabled 0 — Disabled NOTE: If this object is modified, then the object cfgIPv6Enable is also modified. cfgIPv6StaticAddress1 (Read or Write) Description Returns or sets the static IPv6 address1. NOTE: Only sets the current IPv4 address if cfgNicUseDhcp is set to 0 (false).
cfgIPv6StaticDNSServersFromDHCP6 (Read or Write) Description Specifies the DNS server static IP addresses. Legal Values Default • • 0 — DNS Server should be configured as static. 1 — The device will get the DNS servers from DHCPv6. 0— Disabled cfgIPv6StaticDNSServer1 (Read or Write) Description Specifies the DNS server 1 static IPv6 address. Legal Values Any IPv6 Address Default cfgIPv6StaticDNSServer2 (Read or Write) Description Specifies the DNS server 2 static IPv6 address.
cfgNicCurrentGateway Displays the static gateway for the CMC IP address. Description Displays the static gateway for the CMC IP address. Legal Values Default cfgNicCurrentDhcpWasUsed Description Indicates whether DHCP is used to configure the NIC. Legal Values 0 – address is static. 1– address was obtained from the DHCP server. Default None cfgNicCurrentVlanEnable (Read Only) Description Indicates whether the VLAN is enabled.
cfgDNSCurrentServer2 Description Displays the IP address for DNS server 2. Legal Values Default cfgDNSCurrentDomainName Description Displays the DNS domain name. Legal Values Default cfgNicCurrentIPv4Enabled Description Indicates whether IPv4 is enabled on the CMC. If the current property value is set to 0 (false), the remote network interfaces to the CMC are not accessible over IPv4.
cfgCurrentIPv6Enabled Description Indicates whether IPv6 is enabled on the CMC. If the current property value is set to 0 (false), the remote network interfaces to the CMC are not accessible over IPv6. Legal Values Default cfgCurrentIPv6AutoConfigWasUsed Description Indicates whether auto configuration is used to obtain IPv6 settings, including stateless IPv6 address(es) and gateway.
cfgCurrentIPv6DNSServersFromDHCP6 Description Indicates whether the DNS server addresses are assigned from the DHCPv6 server. Legal Values Default cfgCurrentIPv6DNSServer1 Description Displays the IPv6 address for DNS server 1. Legal Values Default cfgCurrentIPv6DNSServer2 Description Displays the IPv6 address for DNS server 2.
It is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers or CMC. cfgIpmiSerialBaudRate (Read/Write) Description Specifies the baud rate for a serial connection over IPMI. Legal Values 9600, 19200, 57600, 115200 Default 57600 cfgIpmiSerialConnectionMode (Read/Write) Description When the iDRAC cfgSerialConsoleEnable property is set to 0 (disabled), the iDRAC serial port becomes the IPMI serial port.
cfgIpmiSerialHandshakeControl (Read/Write) Description Enables or disables the IPMI terminal mode handshake control. Legal Values Default • • 0 (FALSE) 1 (TRUE) 1 cfgIpmiSerialLineEdit (Read/Write) Description Enables or disables line editing on the IPMI serial interface. Legal Values Default • • 0 (FALSE) 1 (TRUE) 1 cfgIpmiSerialEchoControl (Read/Write) Description Enables or disables echo control on the IPMI serial interface.
3 () 4 () 5 () • • • Default 1 cfgIpmiSerialInputNewLineSequence (Read/Write) Description Specifies the input newline sequence specification for the IPMI serial interface. Legal Values Default • • 1 (ENTER) 2 (NULL) 1 cfgSmartCard This group specifies properties used to support access to iDRAC using a smart card. This group is applicable only for iDRAC. The following sections provide information about the objects in the cfgSmartCard group.
cfgNetTuning This group enables users to configure the advanced network interface parameters for the RAC NIC or CMC. When configured, the updated settings may take up to a minute to become active. The following sections provide information about the objects in the cfgNetTuning group. This group is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers. CAUTION: Use extra precaution when modifying properties in this group.
cfgNetTuningNicFullDuplex (Read/Write) Description Specifies the duplex setting for the RAC or CMC NIC. This property is used only if the cfgNetTuningNicAutoNeg is set to 0 (disabled). Legal Values Default • • 0 (Half Duplex) 1 (Full Duplex) 1 cfgNetTuningNicMtu (Read/Write) Description The size in bytes of the maximum transmission unit used by iDRAC or CMC NIC. Legal Values 576 – 1500 Default 1500 NOTE: IPv6 requires a minimum MTU of 1280.
cfgSensorRedundancyCapabilities (Read Only) Description Returns the redundancy capabilities in the form of a bitmask. This bitmask allows the user to know which values can be set for cfgSensorRedundancyPolicy. Legal Values A bit mask. More than 1-bit can be set at a time to indicate multiple redundancy support.
cfgVFlashSDEnable (Read/Write) Description Enables or disables the vFlash SD card. NOTE: Disabling vFlashPartition by setting cfgVFlashSDEnable to 0 does not require a license. Legal Values Default • • 0 (Disable) 1 (Enable) 1 cfgVFlashSDSize (Read Only) Description Displays the size of the vFlash SD card in megabytes (MB). Legal Values A string of upto 64 characters.
• Default Unknown OK cfgVFlashSDWriteProtect (Read Only) Description Displays whether the physical write-protect latch on the vFlash SD card is enabled or disabled. Legal Values Default • • 0 (vFlash is not write-protected) 1 (vFlash is write-protected) None cfgVFlashPartition This group is used to configure properties for individual partitions on the vFlash SD Card. Up to 16 partitions are supported, indexed from 1 to 16. This group is applicable only for iDRAC.
cfgVFlashPartitionFlashOSVolLabel Description Displays the label for the partition that is visible to the operating system. Legal Values An alphanumeric string of up to six characters. Default None cfgVFlashPartitionFormatType (ReadOnly) Description Displays the format type of the partition. Legal Values String: • • • • • • Default FAT16 FAT32 EXT2 EXT3 CD RAW None cfgVFlashPartitionAccessType (Read/Write) Description Indicates the partition access permissions.
The following section provide information about the objects in the cfgLogging group: cfgLoggingSELOEMEventFilterEnable (Read/Write) Description Enables or disables the SEL Log filtering. Legal Values Default • • 0 (Disable) 1 (Enable) 0 cfgRacSecurity This group is used to configure settings related to CMC SSL certificate signing request (CSR) feature. The properties in this group must be configured before generating a CSR from CMC. Use this object with the config or getconfig subcommands.
cfgRacSecCsrLocalityName (Read/Write) Description Specifies the CSR Locality (L). Legal Values A string of up to 254 characters. Default cfgRacSecCsrStateName (Read/Write) Description Specifies the CSR State Name (S). Legal Values A string of up to 254 characters. Default cfgRacSecCsrCountryCode (Read/Write) Description Specifies the CSR Country Code (CC). Legal Values A string of 2 alphabet country code.
cfgRacSecCsrKeySize (Read/Write) Description Specifies the SSL asymmetric key size for the CSRs.
Database Objects With Get and Set Commands 4 This chapter provides the database groups and objects that must be used with the get or set subcommands. These are applicable only for iDRAC7 and are not applicable for CMC. When using these objects, they must begin with FQDD or FQDD alias. NOTE: • The object values in the BIOS and NIC groups are case sensitive. • For NIC objects, the definition of the key format is: Key = ..
• • 256-System Watts 512-Asset Tag Write Privilege Configure iDRAC and Configure User License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.LCD.CurrentDisplay (Read Only) Description The string currently displayed on the LCD. Legal Values None Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.LCD. LCDUserString (Read/Write) Description Indicates the lcd string set by the user.
Dependency None System.Location.DeviceSize (Read Only) Description Indicates server chassis size. Legal Values Values from 1 - 255 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Location.Rack.Name (Read or Write) Description Indicates rack where the system is located. Legal Values String of up to 128 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.
Dependency None System.Location.Chassis.Slot (Read or Write) Description Indicates chassis slot. Legal Values Values from 1 - 255 Write Privilege Configure iDRAC Dependency None System.Power This group provides power management features for iDRAC. The following section provides information about the objects in the System.Power group. System.Power.Status (Read Only) Description Represents the device power state, either ON or OFF. Legal Values • • Default 0 - Server is off 1 - Server is on.
Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.Avg.LastWeek (Read Only) Description Indicates the average power value during the last week. Legal Values Values from 1 - 65535 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.Cap.ActivePolicy.Btuhr (Read Only) Description Represents the active power in BTU/Hr a device is allowed to consume.
System.Power.Cap.Btuhr (Read or Write) Description Represents the maximum power in BTU/Hr a device is allowed to consume. The device may throttle in order to meet this capacity. NOTE: This value is read only on Modular servers . NOTE: This value is applicable only if System.Power.Cap.Enable is set to 1. Legal Values Values from 1 - 65535 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency System.Power.Cap.Enable has to be enabled. System.Power.Cap.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.Cap.Percent (Read or Write) Description Represents the maximum power as a percentage of total power that a server is allowed to consume. The device may throttle in order to meet this cap. NOTE: This value is read only for Modular servers. NOTE: This value is applicable only if System.Power.Cap.Enable is set to 1.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.EnergyConsumption.StarttimeStamp ( Read Only ) Description Displays the Timestamp of the cumulative power consumption. Legal Values String of up to 254 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Write Privilege None System.Power.Hotspare.Enable (Read or Write) Description Enables HotSpare functionality for the primary PSU selection.
Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.Max.Amps.TimeStamp (Read Only) Description Specifies the timestamp recorded for the Peak Power Consumption since this value was last cleared. Legal Values String up to 254 ASCII characters. Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.Max.
System.Power.Max.LastHour (Read Only) Description Displays the maximum power value during the last hour. Legal Values Values from 1 - 65535 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.Max.LastHour.TimeStamp (Read Only) Description Displays the timestamp of maximum power value during the last hour.
Dependency None System.Power.Max.Power.Timestamp (Read Only) Description Displays time of maximum power consumption. Legal Values String of up to 254 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.Max.PowerClear (Read Only) Description Clears the Maximum PowerConsumption timestamps.
Dependency None System.Power.Min.LastHour.Timestamp (Read Only) Description Indicates the timestamp of minimum power during the last hour. Legal Values String of up to 254 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.Min.LastWeek (Read Only) Description Indicates the minimum power during the last week.
System.Power.PFCEnable (Read or Write) Description Enables the power factor correction enable. NOTE: • • Legal Values • • This object is supported only for iDRAC on Rack and Tower servers. This object is applicable only if System.Power.Cap.Enable is set to 1. 0 - Disabled 1 - Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.Power.
Default 0 System.Power.Supply This group provides information relating to the Power Supplies. This group is indexed from 1 to 4. If there are less than 4 power supplies on the server, then some of the last indexes of this group are not applicable. This group is not applicable for iDRAC on Rack and Tower servers. The following section provides information about the objects in the .Power.Supply group. System.Power.Supply.
System.Power.Supply.[i].Status (Read Only) Description Displays the status of the power supply unit. Legal Values Default • • • • 0 - absent 1 - present and OK 2 - failure 3 - predictive failure 0 System.Power.Supply.[i].Type (Read Only) Description Displays whether the power supply is AC or DC. This is an indexed group and the square brackets are only placeholders, and do not form a part of command syntax. Legal Values String upto 32 characters. Default None System.Power.Supply.[i].
System.ServerOS.OSName (Read or Write) Description Displays the operating system name of the managed server. Legal Values String of up to 254 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None System.ServerOS.OSVersion (Read Only) Description Indicates the operating system version of the managed server.
LC.LCAttributes.PartConfigurationUpdate (Read or Write) Description Apply hardware configuration to the replaced part on part replacement. Legal Values 0 - Disabled 1 - Apply Always 2 - Apply only if Firmware Match Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None LC.LCAttributes.PartFirmwareUpdate (Read or Write) Description Apply firmware changes to the replaced part on part replacement.
Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.ActiveDirectory.DCLookupByUserDomain (Read or Write) Description Legal Values Enables selection of the option to look up the user domain for Active Directory. • • 0 — Disabled 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency Cannot be disabled unless the DC Lookup Domain Name is set. iDRAC.ActiveDirectory.
iDRAC.ActiveDirectory.DomainController1 (Read or Write) Description FQDN that stores the address of the active directory domain controller 1. Legal Values String of up to 254 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.ActiveDirectory.
Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency Cannot be enabled unless one of the following is configured: • • • • IPv4.DNS1 IPv4.DNS2 IPv6.DNS1 IPv6.DNS2 iDRAC.ActiveDirectory.GCRootDomain (Read or Write) Description The name of the Active Directory root domain used for DNS look up. Legal Values String of up to 254 ASCII characters Write Privilege Configure iDRAC License Required None Dependency None iDRAC.ActiveDirectory.
License Required iDRAC7 Enterprise Dependency None iDRAC.ActiveDirectory.RacDomain (Read or Write) Description Active Directory Domain in which iDRAC resides. Legal Values String of up to 254 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.ActiveDirectory.RacName (Read or Write) Description Name of iDRAC as recorded in the Active Directory forest.
iDRAC.ADGroup.Domain (Read or Write) Description Active Directory Domain in which the Role Group resides. Legal Values String of up to 254 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.ADGroup.Name (Read or Write) Description Name of the Role Group as recorded in the Active Directory forest. Legal Values String of up to 254 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.
iDRAC.EmailAlert Use the objects in this group to configure e-mail alerting capabilities. iDRAC.EmailAlert.Address (Read or Write) Description Specifies the destination email address for email alerts. Legal Values A valid IPv4 or IPv6 address Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.EmailAlert.CustomMsg (Read or Write) Description Specifies the custom message that forms the subject of the alert.
Dependency None iDRAC.Info.Description (Read Only) Description Text description of the iDRAC. Legal Values String of up to 255 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Info.Name (Read Only) Description User assigned name identifying this controller. Legal Values String of up to 15 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.
Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPBlocking Use the objects in this group to configure IP address blocking feature of iDRAC. iDRAC.IPBlocking.BlockEnable (Read or Write) Description Legal Values Enables or disables the IPv4 address blocking feature of iDRAC. • • 0 — Disabled 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPBlocking.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPBlocking.RangeAddr (Read or Write) Description Specifies the acceptable IPv4 address bit pattern in positions determined by the 1s in the range mask. Legal Values Valid IPv4 Address Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPBlocking.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPMILan.CommunityName (Read or Write) Description Specifies the SNMP community name for traps. Legal Values String of up to 18 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPMILan.Enable (Read or Write) Description Legal Values Enables or disables the IPMI over LAN interface.
iDRAC.IPMISerial Use the objects in this group to configure the IPMI serial interface. NOTE: This is supported only for rack and tower systems. iDRAC.IPMISerial.BaudRate (Read or Write) Description Legal Values Specifies the baud rate for serial connection over IPMI. • • • • 9600 19200 57600 115200 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPMISerial.
iDRAC.IPMISerial.DeleteControl (Read or Write) Description Legal Values Enables or disables delete control on the IPMI serial interface. • • 0 — Disabled 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPMISerial.EchoControl (Read or Write) Description Legal Values Enables or disables echo control on the IPMI serial interface.
iDRAC.IPMISerial.InputNewLineSeq (Read or Write) Description Legal Values Specifies the input new line sequence for the IPMI serial interface. • • 1- Enter 2- Null Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPMISerial.LineEdit (Read or Write) Description Legal Values Enables or disables line editing on the IPMI serial interface.
iDRAC.IPMISOL.AccumulateInterval (Read or Write) Description Specifies the typical amount of time that iDRAC waits before transmitting a partial SOL character data packet. Legal Values Integral values from 1 to 255 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPMISOL.BaudRate (Read or Write) Description Specifies the Baud rate for serial communication over LAN.
iDRAC.IPMISOL.SendThreshold (Read or Write) Description Specifies the SOL threshold limit value and the maximum number of bytes to buffer before sending an SOL data packet. Legal Values Integral values from 1 to 255 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv4 Use the objects in this group to manage the IPv4 configuration properties of iDRAC. iDRAC.IPv4.
iDRAC.IPv4.DNS2 (Read or Write) Description IPv4 address for DNS Server 2. Legal Values Valid IPv4 Address Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Cannot be set unless IPv4.DNSFromDHCP is disabled. iDRAC.IPv4.DNSFromDHCP (Read or Write) Description Legal Values Specifies if the DNS server IPv4 addresses should be assigned from the DHCP server on the network.
iDRAC.IPv4.Netmask (Read or Write) Description The subnet mask used for the iDRAC IPv4 address. Legal Values Valid IPv4 netmask Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Cannot be set unless IPv4.DHCPEnable is disabled. iDRAC.IPv4Static Use the objects in this group to manage the IPv4 Static configuration properties of iDRAC. iDRAC.IPv4Static.Address (Read or Write) Description iDRAC static IPv4 address.
iDRAC.IPv4Static.Gateway (Read or Write) Description iDRAC static IPv4 gateway. This address can be configured even when DHCP is enabled. Legal Values Valid IPv4 gateway Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv4Static.Netmask (Read or Write) Description iDRAC static IPv4 subnet mask. This address can be configured even when DHCP is enabled.
iDRAC.IPv6.Address 5 (Read Only) Description iDRAC IPv6 fifth address. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv6.Address 6 (Read Only) Description iDRAC IPv6 sixth address. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv6.Address 7 (Read Only) Description iDRAC IPv6 seventh address.
iDRAC.IPv6.Address1 (Read or Write) Description iDRAC IPv6 Address. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Cannot be set unless IPv6.AutoConfig is disabled. iDRAC.IPv6.Address10 (Read Only) Description iDRAC IPv6 tenth address. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv6.
iDRAC.IPv6.Address14 (Read Only) Description iDRAC IPv6 fourteenth address. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv6.Address15 (Read Only) Description iDRAC IPv6 fifteenth address. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv6.Address3 (Read Only) Description iDRAC IPv6 third address.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Cannot be set unless IPv6.DNSFromDHCP6 is disabled. iDRAC.IPv6.DNS2 (Read or Write) Description IPv6 DNS Server 2 Address. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Cannot be set unless IPv6.DNSFromDHCP6 is disabled. iDRAC.IPv6.
iDRAC.IPv6.LinkLocalAddress (Read or Write) Description iDRAC IPv6 Link Local Address. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv6.PrefixLength (Read or Write) Description Prefix length for the iDRAC IPv6 Address. Legal Values Integral values from 1 to 128 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.
iDRAC.IPv6Static.DNS2 (Read or Write) Description Statically configurable DNS Server 2. Legal Values Valid IPv6 Address Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.IPv6Static.DNSFromDHCP6 (Read or Write) Description Legal Values Specifies if the DNS server IPv6 addresses should be assigned from the DHCP server on the network.
iDRAC.IPv6URL.URL (Read Only) Description iDRAC IPv6 URL String of format 'https://[ipv6 address]:' Legal Values IPv6 URL String Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency iDRAC IPv6 has to be Enabled iDRAC.LDAP Use the objects in this group to configure properties for LDAP settings. iDRAC.LDAP.BaseDN (Read or Write) Description The Domain Name of the branch of the directory where all searches should start from.
iDRAC.LDAP.CertValidationEnable (Read or Write) Description Legal Values Controls certificate validation during SSL handshake. • • 0 — Disabled 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.LDAP.Enable (Read or Write) Description Legal Values Turns LDAP service on or off. • • 0 — Disabled 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.LDAP.
iDRAC.LDAP.Port (Read or Write) Description Port of LDAP over SSL. Legal Values Integer values from 1- 65535 Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.LDAP.SearchFilter (Read or Write) Description A valid LDAP search filter to be used if the user attribute cannot uniquely identify the login user within the chosen baseDN.
iDRAC.LDAPRoleGroup.DN (Read or Write) Description This is the Domain Name of the group. Legal Values String of up to 1024 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.LDAPRoleGroup.Privilege (Read or Write) Description A bit-mask defining the privileges associated with this particular group.
Dependency None iDRAC.Logging iDRAC. Logging Manages the ability to configure iDRAC iDRAC.Logging.SELOEMEventFilterEnable (Read or Write) Description Enables or disables the ability of Logging SEL Records with OEM. Legal Values • • 0 — Disabled 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.NIC Use the objects in this group to configure the iDRAC NIC. iDRAC.NIC.
iDRAC.NIC.DedicatedNICScanTime (Read or Write) Description Wait time for the iDRAC to switch from dedicated mode to shared mode. Legal Values Integral values from 5 - 255 Write Privilege Configure iDRAC License Required iDRAC7 Express (for Blades) or iDRAC7 Enterprise Dependency None iDRAC.NIC.DNSDomainFromDHCP (Read or Write) Description Legal Values Specifies that the iDRAC DNS Domain Name should be assigned from the network DHCP server.
iDRAC.NIC.DNSRacName (Read or Write) Description The iDRAC name. Legal Values String of up to 63 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.NIC.DNSRegister (Read or Write) Description Legal Values Registers the iDRAC name with the DNS server. • • 0 — Disabled 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Can be Enabled only if DNSRacName is set.
iDRAC.NIC.Failover (Read or Write) Description Enables or disables failover for idrac to switch from shared to dedicated. Legal Values • • • • • • 0- None 2- LOM1 3- LOM2 4- LOM3 5- LOM4 6- All Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Possible Values depend on current NIC Selection settings. iDRAC.NIC.MACAddress (Read Only) Description The MAC Address of the iDRAC.
Write Privilege Configure iDRAC License Required iDRAC7 Express (for Blades) or iDRAC7 Enterprise Dependency None iDRAC.NIC.SharedNICScanTime (Read or Write) Description Wait time for the iDRAC to switch from shared mode to dedicated mode. Legal Values Integral values from 5 - 255 Write Privilege Configure iDRAC License Required iDRAC7 Express (for Blades) or iDRAC7 Enterprise Dependency None iDRAC.NIC.Speed (Read or Write) Description Legal Values Specifies the speed for the iDRAC NIC.
NOTE: This object is applicable only to iDRAC on Racks and Towers. Legal Values Integral values from 1 - 4069 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Cannot be changed unless VLanEnable is enabled. iDRAC.NIC.VLanPriority (Read Only) Description Specifies the VLAN priority for the network VLAN configuration. NOTE: This object is applicable only to iDRAC on Racks and Towers.
iDRAC.NTPConfigGroup Use the objects in this group to configure the properties of NTP server. iDRAC.NTPConfigGroup.NTP1 (Read or Write) Description Configure NTP Server 1 Address. Legal Values String of up to 254 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.NTPConfigGroup.NTP2 (Read or Write) Description Configure NTP Server 2 Address.
iDRAC.NTPConfigGroup.NTPMaxDist (Read or Write) Description NTP Maximum Distance Legal Values Integral values from 1 to 128 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.OS-BMC Use the objects in this group to manage OS-BMC pass-through feature. iDRAC.OS-BMC.AdminState (Read or Write) Description Legal Values Enables or disables administrative state of OS to iDRAC pass through.
iDRAC.Racadm Use the objects in this group to manage Remote RACADM connection settings. iDRAC.Racadm.Enable (Read or Write) Description Enables or disables Remote RACADM interface. Legal Values • • 0 — Disabled 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Racadm.Timeout (Read or Write) Description Defines the idle timeout in seconds of the Remote RACADM interface.
iDRAC.RFS.AttachMode (Read or Write) Description RFS Media attach mode. Write Privilege Configure iDRAC Legal Values • • 0- Attach 1- Auto Attach License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.RFS.MediaAttachState (Read Only) Description Legal Values RFS Media attach state. • • 0- Attached 1- Detached Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.
iDRAC.Security.CsrEmailAddr (Read or Write) Description Specifies the CSR email address. Legal Values Valid email address string of up to 254 ASCII characters. Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Security.CsrKeySize (Read or Write) Description Legal Values Specifies the SSL asymmetric key size for the CSRs.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Security.CsrStateName (Read or Write) Description Specifies the CSR State Name (S). Legal Values String of up to 254 ASCII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Serial The objects in this group provide configuration parameters for the serial interface of iDRAC. NOTE: This is supported only for rack and tower systems. iDRAC.Serial.
iDRAC.Serial.Enable (Read or Write) Description Enables or disables the iDRAC serial console interface. Legal Values • • 0 — Disabled 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Serial.HistorySize (Read or Write) Description Specifies the maximum size of the serial history buffer. Legal Values Integral values from 0 to 8192.
NOTE: This is supported only for rack and tower systems. iDRAC.SerialRedirection.Enable (Read or Write) Description Legal Values Enables or disables the console for COM2 port redirection. • • 0 — Disabled 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.SerialRedirection.QuitKey (Read or Write) Description This key or key combination terminates the Virtual Console when using the console COM2 command.
Write Privilege Configure iDRAC and Configure User License Required iDRAC7 Enterprise Dependency ActiveDirectory.SSOEnable has to be disabled iDRAC.SNMP The objects in this group enable you to configure the SNMP agent and trap capabilities. iDRAC.SNMP.AgentCommunity (Read or Write) Description Specifies the SNMP community name to be used for SNMP traps.
License Required None Dependency None iDRAC.SNMP.SNMPProtocol (Read or Write) Description Legal Values Specified the SNMP protocol. • • 0- All 1- SNMPv3 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.SNMP.TrapFormat (Read or Write) Description Legal Values Specifies the SNMP format. • • 0- SNMPv1 1- SNMPv2 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.
Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.SSH.Timeout (Read or Write) Description Defines the secure shell idle timeout. Legal Values Integral values from 0 to 10800 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.SysLog The objects in this group provide the properties for configuration of the SMTP server. iDRAC.SysLog.
Dependency None iDRAC.SysLog.Server1 (Read or Write) Description Name of remote syslog server 1. Legal Values String of up to 63 ACSII characters Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.SysLog.Server2 (Read or Write) Description Name of remote syslog server 2. Legal Values String of up to 63 ACSII characters Write Privilege Configure iDRAC License Required iDRAC7 Enterprise Dependency None iDRAC.SysLog.
iDRAC.Telnet.Enable (Read or Write) Description Enables or disables Telnet. Legal Values • • 0 — Disabled 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Telnet.Port (Read or Write) Description Specifies the port number for the iDRAC Telnet interface. Legal Values Integral values from 10 to 65535 Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Telnet.
iDRAC.Tuning The objects in this group enable you to manage iDRAC tuning and configuration parameters. iDRAC.Tuning.DefaultCredentialWarning (Read or Write) Description Legal Values Enables or disables the default credentials warning. • • 0- Disabled 1- Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Update The objects in this group enable you to manage configuration parameters for iDRAC firmware update. iDRAC.Update.
• 1- Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.UserDomain The objects in this group enable you to manage the Active Directory user domain names. iDRAC.UserDomain.Name (Read or Write) Description Specifies the Active Directory user domain name for a given index. Legal Values String of up to 255 ACSII characters Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Both user name and password must be configured prior to setting this object. iDRAC.Users.IpmiSerialPrivilege (Read or Write) Description Specifies the maximum IPMI Serial privilege.
Write Privilege Configure iDRAC and Configure User License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Users.SNMPv3Enable (Read or Write) Description Enables or disables SNMPv3 support for an iDRAC User. Legal Values • • 0- Disabled 1- Enabled Write Privilege Configure iDRAC and Configure User License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.Users.SNMPv3PrivacyType (Read or Write) Description Configrue SNMPv3 privacy protocol type.
Dependency None iDRAC.VirtualConsole The objects in this group enable you to manage virtual console configuration parameters of iDRAC. iDRAC.VirtualConsole.AccessPrivilege (Read or Write) Description Legal Values Default action upon session sharing request timeout. • • • 0- Deny Access 1- Read Only Access 2 - Full Access Write Privilege Configure iDRAC License Required iDRAC7 Express (For Blades) or iDRAC7 Enterprise Dependency None iDRAC.VirtualConsole.
• 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express (For Blades) or iDRAC7 Enterprise Dependency None iDRAC.VirtualConsole.MaxSessions (Read or Write) Description Specifies maximum number of virtual console sessions. Legal Values Integral values from 1 to 4 Write Privilege Configure iDRAC License Required iDRAC7 Express (For Blades) or iDRAC7 Enterprise Dependency None iDRAC.VirtualConsole.
iDRAC.VirtualMedia The objects in this group enable you to manage virtual media configuration parameters of iDRAC. iDRAC.VirtualMedia.Attached (Read or Write) Description Legal Values Used to attach virtual devices to the system via the USB bus. • • • 0- Detached 1- Attached 2- AutoAttach Write Privilege Virtual Media License Required iDRAC7 Express (For Blades) or iDRAC7 Enterprise Dependency None iDRAC.VirtualMedia.
iDRAC.WebServer.Enable (Read or Write) Description Legal Values Enables or disables iDRAC WebServer. • • 0 — Disabled 1 — Enabled Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None iDRAC.WebServer.HttpPort (Read or Write) Description Specifies the port number for HTTP communication with the iDRAC.
Write Privilege Configure iDRAC License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.BiosBootSettings You can manage the BIOS boot settings using the objects in this group. BIOS.BiosBootSettings.BiosBootSeq (Read or Write) Description Determines the Bios boot sequence of the system. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if BootMode is set to UEFI BIOS.BiosBootSettings.
Dependency Read Only if BootMode is set to UEFI BIOS.BiosBootSettings.UefiBootSeq (Read or Write) Description UEFI boot sequence Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if BootMode is set to BIOS BIOS.IntegratedDevices You can use the objects in this group to manage the integrated devices such as internal NIC and integrated USB. BIOS.IntegratedDevices.
BIOS.IntegratedDevices.EmbNic2 (Read or Write) Description Legal Values Enables or disables the operating system interface of the embedded NIC2. • • • • Enabled EnabledPxe EnablediScsi Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.IntegratedDevices.EmbNic3 (Read or Write) Description Legal Values Enables or disables the operating system interface of the embedded NIC3.
BIOS.IntegratedDevices.EmbNic4 (Read or Write) Description Legal Values Enables or disables the operating system interface of the embedded NIC4. • • • • Enabled EnabledPxe EnablediScsi Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.IntegratedDevices.EmbVideo (Read or Write) Description Legal Values Enables or disables the BIOS support for the embedded video controller.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.IntegratedDevices.IntegratedRaid (Read or Write) Description Legal Values Enables or disables the integrated RAID controller. • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.IntegratedDevices.IntegratedSas (Read or Write) Description Legal Values Enables or disables the integrated SAS controller.
Dependency Read Only if 'InternalSdCard' is set to 'Off'. BIOS.IntegratedDevices.InternalUsb (Read or Write) Description Enable or disable the internal USB port. Legal Values • • On Off Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.IntegratedDevices.InternalUsb1 (Read or Write) Description Enables or disables the internal USB port 1.
BIOS.IntegratedDevices.SriovGlobalEnable (Read or Write) Description Legal Values Enables or disables BIOS configuration of Single Root I/O Virtualization (SR-IOV) devices. • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.IntegratedDevices.UsbPorts (Read or Write) Description Legal Values Sets the user accessible USB ports.
• • • MirrorMode AdvEccMode SpareWithAdvEccMode Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.MemSettings.MemOptimizer (Read or Write) Description Configure the memory optimizer setting. Legal Values • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.MemSettings.MemOpVoltage (Read Only) Description Legal Values Operating voltage of memory.
BIOS.MemSettings.MemVolt (Read or Write) Description Legal Values Sets the DIMM voltage selection. • • • AutoVolt Volt135V Volt15V Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if SysProfileSettings.SysProfileis set to Custom BIOS.MemSettings.NodeInterleave (Read or Write) Description Legal Values If the system is configured with matching memory this field enables node interleaving.
• Valid Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.MemSettings.RedundantMemInUse (Read Only) Description Display the current redundant memory setting in BIOS. Legal Values • • NotInUse InUse Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.MemSettings.SnoopFilter (Read or Write) Description Enables or disables the snoop filter option.
Dependency None BIOS.MemSettings.SysMemType (Read Only) Description Indicates the current type of main memory installed in the system. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.MemSettings.SysMemVolt (Read Only) Description Displays the current operating voltage of main memory. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.
BIOS.MiscSettings.ErrPrompt (Read or Write) Description Enables or disables the F1 and F2 prompt on error. Legal Values • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.MiscSettings.NumLock (Read or Write) Description Determines whether the system boots with Num Lock enabled or disabled. This is not applicable for 84-key keyboards.
Dependency None BIOS.OneTimeBoot You can manage the one time boot settings using the objects in this group. BIOS.OneTimeBoot.OneTimeBootMode (Read or Write) Description Legal Values Configure the one time boot mode settings. • • • • Disabled OneTimeBootSeq OneTimeHddSeq OneTimeUefiBootSeq Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.OneTimeBoot.
Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if OneTimeBootModeis not set to OneTimeHddSeq BIOS.OneTimeBoot.OneTimeUefiBootSeqDev (Read or Write) Description Configure the one time UEFI Boot Sequence device. Legal Values NIC or Optical Device list Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if OneTimeBootModeis not set to OneTimeUefiBootSeq BIOS.
• Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.DcuStreamerPrefetcher (Read or Write) Description Enables or disables Data Cache Unit (DCU) Streamer Prefetcher. Legal Values • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.
BIOS.ProcSettings.Proc1Brand (Read Only) Description Provides the processor brand name. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.Proc1Id (Read Only) Description Provides the processor's family model and stepping values. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.
Dependency None BIOS.ProcSettings.Proc2Brand (Read Only) Description Provides the processor brand name. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.Proc2Id (Read Only) Description Processor's family model and stepping values. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.
Dependency None BIOS.ProcSettings.Proc3Brand (Read Only) Description Brand text provided by the processor manufacturer. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.Proc3Id (Read Only) Description Processor's family model and stepping values. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.
Dependency None BIOS.ProcSettings.Proc4Brand (Read Only) Description Brand text provided by the processor manufacturer. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.Proc4Id (Read Only) Description Processor's family model and stepping values. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.
Dependency None BIOS.ProcSettings.Proc64bit (Read Only) Description Specifies whether the installed processor(s) support 64-bit extensions. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.ProcAdjCacheLine (Read or Write) Description Enables or disables the system optimization for applications that require high utilization of sequential memory access.
• • • 12 14 16 Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.ProcCoreSpeed (Read Only) Description Clock speed of the processor(s). Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.ProcDramPrefetcher (Read or Write) Description Legal Values Enable to turn on the DRAM prefetch unit in the Northbridge.
BIOS.ProcSettings.ProcHpcMode (Read or Write) Description Configure processor's HPC mode. Legal Values • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.ProcHtAssist (Read or Write) Description Legal Values When enabled it provides filtering of broadcast probes to improve HyperTransport I/O Link bandwidth and performance on multi-node systems.
Dependency None BIOS.ProcSettings.ProcSoftwarePrefetcher (Read or Write) Description Legal Values Enables or disables the hardware prefetcher for considering software prefetches when detecting strides for prefetch requests. • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.
Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.ProcSettings.RtidSetting (Read or Write) Description Allocates more RTIDs to the remote socket increasing cache performance between the sockets. Legal Values • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings Use the objects in this group to configure the BIOS SATA settings. BIOS.SataSettings.
BIOS.SataSettings.eSataPort1Capacity (Read Only) Description Displays the total capacity of a hard-disk drive. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.eSataPort1DriveType (Read Only) Description Indicates type of device attached to this SATA port. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.SataPortADriveType (Read Only) Description Indicates type of device attached to this SATA port. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.SataPortAModel (Read Only) Description Displays the drive model of the selected device.
BIOS.SataSettings.SataPortBDriveType (Read Only) Description Indicates type of device attached to this SATA port. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.SataPortBModel (Read Only) Description Displays the drive model of the selected device. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.SataPortCModel (Read Only) Description Displays the drive model of the selected device. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.SataPortD (Read or Write) Description Legal Values Sets the drive type of the selected device.
BIOS.SataSettings.SataPortDDriveType (Read Only) Description Indicates type of device attached to this SATA port. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.SataPortDModel (Read Only) Description Displays the drive model of the selected device. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.SataPortEModel (Read Only) Description Displays the drive model of the selected device. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.SataPortF (Read or Write) Description Legal Values Sets the drive type of the selected device.
BIOS.SataSettings.SataPortFModel (Read Only) Description Displays the drive model of the selected device. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.SataPortG (Read or Write) Description Sets the drive type of the selected device. Legal Values • • Off Auto Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if EmbSatais not set to AtaMode.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SataSettings.SataPortH (Read or Write) Description Sets the drive type of the selected device. Legal Values • • Off Auto Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if EmbSatais not set to AtaMode. BIOS.SataSettings.SataPortHCapacity (Read Only) Description Displays the total capacity of a hard-disk drive.
BIOS.SerialCommSettings.ConTermType (Read or Write) Description Legal Values Configures the remote console's terminal type. • • Vt100Vt220 Ansi Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SerialCommSettings.ExtSerialConnector (Read or Write) Description Legal Values Associate the External Serial Connector to Serial 1 or Serial 2 or Remote Access Device.
Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SerialCommSettings.SerialComm (Read or Write) Description Legal Values Controls the serial communication options. • • • • • Off OnNoConRedir OnConRedirCom1 OnConRedirCom2 OnConRedir Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SerialCommSettings.
Dependency None BIOS.SlotDisablement.Slot2 (Read or Write) Description Legal Values Control the configuration of the card installed in slot 2. • • • Enabled Disabled BootDriverDisabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SlotDisablement.Slot3 (Read or Write) Description Legal Values Control the configuration of the card installed in slot 3.
Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SlotDisablement.Slot6 (Read or Write) Description Legal Values Control the configuration of the card installed in slot 6. • • • Enabled Disabled BootDriverDisabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SlotDisablement.Slot7 (Read or Write) Description Legal Values Control the configuration of the card installed in slot 7.
BIOS.SysInformation.SystemBiosVersion (Read Only) Description Provides the current revision of the system BIOS firmware. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SysInformation.SystemCpldVersion (Read Only) Description Displays the current revision of the system CPLD firmware. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.
Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SysProfileSettings Use the objects in this group to manage the system profile settings. BIOS.SysProfileSettings.MemFrequency (Read or Write) Description Legal Values Set the speed of the system memory to maximum performance, maximum reliability or a specific speed.
• Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SysProfileSettings.MemRefreshRate (Read or Write) Description Legal Values Frequency at which memory is normally refreshed. • • 1x 2x Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if SysProfileSettings.SysProfileis set to Custom. BIOS.SysProfileSettings.
BIOS.SysProfileSettings.ProcCStates (Read or Write) Description Legal Values Enables or disables the processor C-States. • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if SysProfileSettings.SysProfileis set to Custom. BIOS.SysProfileSettings.ProcPwrPerf (Read or Write) Description Legal Values Sets CPU power management to maximum performance operating system DBPM or System DBPM (DAPC) mode.
BIOS.SysProfileSettings.SysProfile (Read or Write) Description Sets the System Profile to Performance Per Watt (DAPC), Performance Per Watt (OS) Performance Dense Configuration, or Custom mode. Legal Values • • • • • PerfPerWattOptimizedOs PerfPerWattOptimizedDapc PerfOptimized Custom DenseCfgOptimized Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.
Dependency None BIOS.SysSecurity.AcPwrRcvryUserDelay (Read Only) Description Controls the user defined AC Recovery Delay. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SysSecurity.IntelTxt (Read or Write) Description Legal Values Enables or disables Trusted Execution Technology.
• Unlocked Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SysSecurity.PwrButton (Read or Write) Description Legal Values Enables or disables the power button on the front panel. • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SysSecurity.SetupPassword (Read or Write) Description Setup the system password.
• • • • Up to 32 characters including whitespace. Contain numbers 0 through 9. Only lower case alphabets are accepted. Special characters accepted are +, ", ,, -, ., /, ;, [, \, ], `. To enable password modification, J_EN_PASSWD should be installed. To clear the already configured password, use the option available under F2 (system setup) during system boot.
• On Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None BIOS.SysSecurity.TpmActivation (Read or Write) Description Specify the operational state of the Trusted Platform Module (TPM). Legal Values • • • NoChange Activate Deactivate Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Read Only if SysSecurity.TpmSecurity is set to Off. BIOS.SysSecurity.
NIC.DCBSettings The following section provides information about the objects in the NIC.DCBSettings group. NIC.DCBSettings.CongestionNotification (Read Only) Description Indicates whether Congestion Notification capability is supported. Legal Values • • Available Unavailable Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.DCBSettings.
• Unavailable Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.DeviceLevelConfig Use the objects in this group to manage the device level configurations. NIC.DeviceLevelConfig.EVBModesSupport (Read Only) Description Legal Values Indicates the type of EVB Modes supported. • • • • VEB VEPA PE Multi-channel Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.DeviceLevelConfig.
Dependency None NIC.FCOECapabilities The following section provides information about the objects in the NIC.FCOECapabilities group. NIC.FCOECapabilities.AddressingMode (Read Only) Description Indicates whether SPMA or FPMA addressing is used for FCoE transactions. Legal Values • • SPMA FPMA Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.FCOECapabilities.
NIC.FCOECapabilities.MaxNumberExchanges (Read Only) Description Indicates the maximum number of exchanges supported. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.FCOECapabilities.MaxNumberLogins (Read Only) Description Indicates the maximum number of logins supported per port. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.
• Unavailable Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.FCoEConfiguration The following section provides information about the objects in the NIC.FCoEConfiguration group. NIC.FCoEConfiguration.ConnectFirstFCoETarget (Read or Write) Description Legal Values Specifies whether FCoE initiator is used to connect to the first FCoE storage target defined.
NIC.FCoEConfiguration.FirstFCoEWWPNTarget (Read or Write) Description World Wide Port Name (WWPN) of the first FCoE storage target. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.FCoEConfiguration.MTUParams (Read or Write) Description Legal Values Configure the MTU setting. • • • Global Per DCB Priority Per VLAN Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.
NIC.FCoEGenParams.FCoEFabricDiscoveryRetryCnt (Read or Write) Description Retry count for FCoE fabric discovery. Legal Values Values from 0 - 60 Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.FCoEGenParams.FCoEFirstHddTarget (Read or Write) Description Specifies whether the FCoE target is represented as the first HDD to the system.
NIC.FCoEGenParams.FCoETgtBoot (Read or Write) Description Enables the FCoE initiator to boot system to the FCoE target. Legal Values • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.FrmwImgMenu The following section provides information about the objects in the NIC.FrmwImgMenu group. NIC.FrmwImgMenu.ControllerBIOSVersion (Read Only) Description Indicates the controller BIOS version information.
NIC.GlobalBandwidthAllocation The following section provides information about the objects in the NIC.GlobalBandwidthAllocation group. NIC.GlobalBandwidthAllocation.MaxBandwidth (Read or Write) Description Set the maximum percentage of port TX bandwidth allocated to partition. Legal Values Values from 0 - 100 Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.GlobalBandwidthAllocation.
Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not Available if 'VndrConfigGroup.iSCSIBootSupport' is Unavailable. NIC.IscsiFirstTgtParams.FirstTgtChapId (Read or Write) Description Set the first iSCSI storage target Challenge-Handshake Authentication Protocol (CHAP) ID.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not Available if 'VndrConfigGroup.iSCSIBootSupport' is Unavailable. NIC.IscsiFirstTgtParams.FirstTgtTcpPort (Read or Write) Description Set the TCP Port number of the first iSCSI target. Legal Values Values from 1 - 65535 Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not Available if 'VndrConfigGroup.iSCSIBootSupport' is Unavailable. NIC.
NIC.IscsiGenParams.DhcpVendId (Read or Write) Description Control what Vendor ID is presented to the DHCP service. Legal Values String of upto 255 ASCII characters Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not Available if 'VndrConfigGroup.iSCSIBootSupport' is Unavailable. NIC.IscsiGenParams.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not Available if 'VndrConfigGroup.iSCSIBootSupport' is Unavailable. NIC.IscsiGenParams.IscsiViaDHCP (Read or Write) Description Legal Values Enables the acquisition of iSCSI target parameters from DHCP. • • Enabled Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not Available if 'VndrConfigGroup.iSCSIBootSupport' is Unavailable. NIC.IscsiGenParams.
Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not Available if 'IscsiGenParams.IpVer' is set to 'IPv6' and 'VndrConfigGroup.iSCSIBootSupport' is Unavailable. NIC.IscsiGenParams.TcpTimestmp (Read or Write) Description Legal Values Enables or disables use of TCP timestamps in network packets as defined in RFC 1323.
NIC.IscsiInitiatorParams.IscsiInitiatorChapPwd (Password) Description Set the iSCSI initiator Challenge-Handshake Authentication Protocol (CHAP) secret (password). Legal Values String of 12 - 16 characters Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not available if 'VndrConfigGroup.iSCSIBootSupport' is unavailable. NIC.IscsiInitiatorParams.IscsiInitiatorGateway (Read or Write) Description Specifies the Default Gateway of the iSCSI initiator.
NIC.IscsiInitiatorParams.IscsiInitiatorPrimDns (Read or Write) Description Specifies the Primary DNS IP address of the iSCSI initiator. Legal Values String of 2 to 39 characters (Ipv4 or Ipv6 gateway) Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not available if 'VndrConfigGroup.iSCSIBootSupport' is unavailable. NIC.IscsiInitiatorParams.IscsiInitiatorSecDns (Read or Write) Description Specifies the Secondary DNS IP address of the iSCSI initiator.
NIC.IscsiSecondaryDeviceParams.SecondaryDeviceMacAddr (Read or Write) Description Specifies the MAC address of a secondary iSCSI boot adapter for redundancy in case of boot failure. Legal Values String of up to 17 characters Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not available if 'VndrConfigGroup.iSCSIBootSupport' is unavailable. NIC.IscsiSecondaryDeviceParams.
• Disabled Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not available if 'VndrConfigGroup.iSCSIBootSupport' is unavailable. NIC.IscsiSecondTgtParams.SecondTgtBootLun (Read or Write) Description Specifies the second iSCSI storage target boot Logical Unit Number (LUN).
Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency Not available if 'VndrConfigGroup.iSCSIBootSupport' is unavailable. NIC.IscsiSecondTgtParams.SecondTgtIscsiName (Read or Write) Description Specifies the iSCSI Qualified Name (IQN) of the second iSCSI storage target. Legal Values String of up to 223 characters NOTE: The legal value range may be smaller than the maximum size of 223, based on the vendor configuration of the NIC cards.
NIC.NICConfig.LnkSpeed (Read or Write) Description Legal Values Specifies the port speed used for the selected boot protocol. • • • • • AutoNeg 10Mbps Half 10Mbps Full 100Mbps Half 100Mbps Full Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.NICConfig.VLanId (Read or Write) Description Specifies the ID (tag) for the VLAN Mode.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.NICConfig.WakeOnLanLnkSpeed (Read or Write) Description Legal Values Select the port speed used for Wake on LAN mode. • • • • • AutoNeg 10Mbps Half 10Mbps Full 100Mbps Half 100Mbps Full Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.NICPartitioningConfig Use the objects in this group to configure the NIC partitioning properties. NIC.NICPartitioningConfig.
NIC.NICPartitioningConfig.NumberPCIEFunctionsSupported (Read Only) Description Indicates the number of physical PCIe functions supported on this port. Legal Values Values from 1 - 65535 Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.BusDeviceFunction (Read Only) Description Indicates the BIOS assigned PCIe.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.DeviceName (Read Only) Description Indicates the official product name of the device. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.EnergyEfficientEthernet (Read Only) Description Indicates whether Energy Efficient Ethernet capability is supported.
NIC.VndrConfigGroup.FCoEOffloadSupport (Read Only) Description Indicates whether FCoE Offload capability is supported. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.FeatureLicensingSupport (Read Only) Description Indicates whether Dell Feature Licensing capability is supported.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.ISCSIMacAddr (Read Only) Description Indicates the permanent MAC address for iSCSI offload assigned during manufacturing. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.iSCSIOffloadMode (Read or Write) Description Legal Values Enables or disables iSCSI offload personality on the port.
NIC.VndrConfigGroup.MacAddr (Read Only) Description Indicates the permanent MAC address assigned during manufacturing. Legal Values String of up to 17 characters Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.NicMode (Read or Write) Description Legal Values Enables or disables NIC personality on the port.
Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.OSBMCManagementPassThrough (Read Only) Description Indicates whether OS-BMC Management Pass Through capability is supported. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.PCIDeviceID (Read Only) Description Indicates the PCI Device ID of the port.
NIC.VndrConfigGroup.RXFlowControl (Read Only) Description Indicates whether Receive (RX) Flow control capability is supported. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.TOESupport (Read Only) Description Indicates whether TCP/IP Offload Engine capability is supported. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.
NIC.VndrConfigGroup.TXFlowControl (Read Only) Description Indicates whether Transmit (TX) Flow Control capability is supported. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.VirtFIPMacAddr (Read or Write) Description Programmatically assignable FIP-MAC address for FCoE. Programmatic write for support of I/O Identity feature.
NIC.VndrConfigGroup.VirtualLinkControl (Read or Write) Description Indicates whether Virtual Link Control capability is supported. Legal Values None Write Privilege Server Control License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None NIC.VndrConfigGroup.VirtWWN (Read or Write) Description Programmatically assignable Fibre Channel World Wide Node Name identifier for FCoE.
License Required iDRAC7 Express or iDRAC7 Enterprise Dependency None 394