Setup Guide

35
Configuring a System via the Startup Wizard
Figure 30. Initial Port Configuration Generated with no Warnings
5 Your next action depends upon the following:
If there are no warnings for either Fibre Channel or iSCSI and there is only one Fibre
Channel switch fabric, click Continue to proceed to Step 13: Generate SSL
Certificate on page 43.
If there are two Fibre Channel switch fabrics, you must select Configure Local
Ports and create a new fault domain for the second switch. Follow your pre-
installation documentation for site-specific connections. Make sure that controller
ports physically connected to fabric 1 are in one fault domain and controller ports
connected to fabric 2 are in another fault domain. Proceed to Configure Virtual Port
Mode Local Ports – FC on page 36.
If there are warnings for either Fibre Channel or iSCSI, click Configure Local Ports
to modify the configuration and correct any issues that cause warnings. Proceed to
Configure Virtual Port Mode Local Ports – FC on page 36 or Configure Virtual Port
Mode Local Ports – iSCSI on page 40.
Configuring Virtual Port Mode Local Ports - FC and iSCSI
You modify local port configuration settings for both Fibre Channel and iSCSI ports by using
the dropdown menus and buttons that appear on the Configure Ports dialog.
For Fibre Channel ports, refer to Configure Virtual Port Mode Local Ports – FC on
page 36.
For iSCSI ports, refer to Configure Virtual Port Mode Local Ports – iSCSI on page 40.