Dell Lifecycle Controller USC-LCE Version 1.5.
What’s New Backup server profile Export server profile Import server profile View and export factory shipped inventory Configuration and firmware upgrade support for Converged Network Adapters (CNA) cards (10GB paritionable NIC with FCoE and iSCSI offload) Supported on the following CNA card: o Broadcom: - M710HD Dual Port 10Gig 57712 NDC Enhancement to the RAID configuration o Software RAID configuration o Virtual disk slicing Driver packs support for new operating systems Prerequisites f
Issue 3 Description In Windows 2003 (32 bit, SBS, and 64 bit), in addition to the device labeled OEMDRV, a floppy drive labeled FLOPPY that contains drivers is also exposed and remains active for 18 hours. Issue 4 Description USC supplies necessary Windows 2003 Server drivers via a temporary, internal USB device that may initially be assigned the drive letter C: during Windows 2003 Server Setup.
Issue 11 Description USC does not support the update or rollback options of PERC5/E Adapter for External Storage or SAS5iR Adapter for tape. Issue 12 Description If a floppy drive is attached to the system when the USC is used to deploy a Windows 2003 Server perating system, error pop-up messages are displayed, and many required device drivers such as NIC, video, and chipset drivers are not installed, but the storage device drivers are installed.
Issue 19 Description When attempting a Platform Rollback, there may be a two minute delay before Rollback tasks are displayed on the screen. Issue 20 Description When using Hardware Configuration Advanced Configuration, if you click on any NIC or BIOS devices and then leave the page and come back, you may experience delays of up to 18 seconds on all the pages. Issue 21 Description In the iDRAC Configuration Wizard, there is not a selection for auto-attached on the Virtual Media Configuration page.
Issue 27 Description On R910 systems, the 'Node Interleaving' option on the 'Memory Settings' page is grayed-out when you access it after a reboot. You must click 'Default' on the main page of 'System BIOS Settings' to enable the 'Node Interleaving' option. Issue 28 Description On an iDRAC version 1.3 installed managed node, the "Part Replacement Configuration" and "Add a work note to Lifecycle Log" features in the USC-LCE do not function, though the features are enabled.
Information in this document is subject to change without notice. © 2012 Dell Inc. All rights reserved. Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell™, the DELL logo, Dell Precision™, OptiPlex™, Latitude™, PowerEdge™, PowerVault™, PowerConnect™, OpenManage™, EqualLogic™, KACE™, FlexAddress™ and Vostro™ are trademarks of Dell Inc.