Dell OpenManage™ Server Administrator Version 5.1 SNMP Reference Guide w w w. d e l l . c o m | s u p p o r t . d e l l .
Notes and Notices NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. ____________________ Information in this document is subject to change without notice. © 2003–2006 Dell Inc. All rights reserved. Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Contents 1 Introduction Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 What’s New in this Release . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction to the SNMP Reference Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 General Content . . . . . . . . . . . . . . . . . . Server Administrator Instrumentation MIB. . . . Server Administrator Remote Access MIB . . .
2 Instrumentation MIB Version Group . . . . . . . . . . . . . . . . 29 MIB Major Version Number . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 MIB Minor Version Number . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 MIB Maintenance Version Number 3 . . . . . . . . . . . . . . . . . . . . . . . Systems Management Software Group Systems Management Software . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . . . . . . . . 31 . . . . . . .
Firmware Table . Intrusion Table . Baseboard Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chassis Information Group Variable Values . 6 Operating System Group. Operating System Group Table . 101 . . . . . . . . . . . . . . . . . . . . . . . . 101 . . . . . . . . . . . . . . . . . . . . 101 103 . . . . . . . . . . . . . . . . . . . . . . . 107 . . . . . . .
9 Thermal Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Thermal Group Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 Cooling Unit Table . . . . . Cooling Device Table . . . Temperature Probe Table . . . . . . . . . . . . . . . . . . . . . . . . . 157 160 165 Thermal Group Variable Values . . . . . . . . . . . . . . . . . . . . . . . . 169 10 User Security Group . . . . . . . . . . . . . . . . . . . . . . . . . . 173 User Security Group Table . . . .
13 Device Group Device Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 . . . . . . . . . . . . . . . . 213 216 218 226 228 234 241 244 247 250 253 . . . . . . . . . . . . . . . . . . . . . . . . 261 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277 Pointing Device Table . . . . . . . . . . . Keyboard Device Table . . . . . . . . . . Processor Device Table. . . . . . . . . .
16 BIOS Setup Control Group BIOS Group Tables . . . . . . . . . . . . . . . . . . . . . . . 311 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311 . . . . . . . . . . . . . . . . . . . . . 311 321 323 325 327 329 331 333 . . . . . . . . . . . . . . . . . . . . . . . . . 335 BIOS Setup Control Table . . . . SCSI Control Table . . . . . . . Parallel Port Control Table . . . Serial Port Control Table . . . . USB Control Table . . . . . . . . IDE Control Table . . . . . . . .
19 Remote Access Group . DRAC 4 . . . . . . . . . . . . . . . . . . . . . . . . 387 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 387 . . . . . . . . . . . . . . . . . . . . . . . . . . 387 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 393 Remote Access Table . DRAC III. . . . . . . . . . . . . . . . . 393 402 410 414 418 421 . . . . . . . . . . . . . . . . . . . . . . . 424 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23 Storage Management Group Storage Management Group . . . . . . . . . . . . . . . . . . . . . 461 . . . . . . . . . . . . . . . . . . . . . . . . . 461 . . . . . . . . . . . . . . . . . . . 463 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 464 Storage Management Information Group Global Data Group Physical Devices Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . Logical Devices Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating System Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inventory Collector Product Information 25 Traps 564 . . . . . . . . . . . . . . . . . . . 566 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 569 Trap Variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System. . . . . . Table Index OID . Message . . . . Current Status . . Previous Status . Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26 Storage Management Alert Reference . . . . . . . . . . . . . 601 . . . . . . . . . . . . . . . . . . . . . . . . . 601 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 601 Alert Monitoring and Logging Viewing Alerts Alert Severity Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 602 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 602 603 603 . . . . . . . . . . . . . . . . . .
Introduction This introduction is divided into two sections. The first section, "Introduction to the SNMP Reference Guide," explains the SNMP Reference Guide design. All essential Simple Network Management Protocol (SNMP) terms are defined in this section. Some of the vocabulary may seem complex and unfamiliar to system administrators who are using SNMP for the first time. SNMP experts can skim this section, and beginners can read the section more carefully.
Introduction to the SNMP Reference Guide This reference guide provides a formatted version of the Server Administrator Instrumentation MIB (filename 10892.mib), the Server Administrator Remote Access MIB (filename dcs3rmt.mib), the Server Administrator Field Replaceable Unit MIB (filename dcs3fru.mib), the Server Administrator Storage Management MIB (filename dcstorag.mib), and the Server Administrator Change Management MIB (filename dellcm.
The Server Administrator Instrumentation MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1., where is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group. Table 1-2.
Table 1-2.
Server Administrator Field Replaceable Unit MIB The Server Administrator Field Replaceable Unit MIB (filename dcs3fru.mib) provides information about field replaceable unit (FRU) hardware that may be present in your system. The Server Administrator Field Replaceable Unit MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information.
Server Administrator Change Management MIB The Server Administrator Change Management MIB (filename dellcm.mib) provides management data that allows you to monitor the inventory of devices and applications with SNMP management applications. Table 1-6 describes each Server Administrator Change Management MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Change Management MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.
SNMP Master Agent Typically, the SNMP agent on a managed system consists of one SNMP master agent and zero or more SNMP extension agents. This SNMP agent extendable structure facilitates the addition of new MIB modules without having to rebuild the entire SNMP agent and is invisible to SNMP management applications. The SNMP master agent is responsible for receiving SNMP request protocol messages from SNMP management applications and sending SNMP response protocol messages.
Variable A variable is a component of a managed object. A temperature probe, for example, has a variable to describe its capabilities, its health or status, and certain indexes that you can use to locate specific temperature probes. One index for the probe would be the probe’s chassis number. Some systems may have multiple chassis—one chassis for the central processing unit and another chassis for storage. A chassis within a system can also have more than one temperature probe.
For example, the OID for the temperature probe managed object table is 700.20 and the variable for the location of the temperature probe (temperatureProbeLocationName) has an OID of 700.20.1.8. The full OIDs for these items are 1.3.6.1.4.1.674.10892.1.700.20 for the temperatureProbeTable and 1.3.6.1.4.1.674.10892.1.700.20.1.8 for the temperatureProbeLocation. For more information about the structure of OIDs, see "SNMP MIB OIDs." Description is a brief explanation of what a particular managed object does.
When a MIB group is divided into one or more discrete tables, the word "table" has a technical meaning. An example is the section of this reference guide entitled Universal Unique Identifier (UUID). The UUID object has a type and a value that uniquely identify an object such as a chassis. The table defines all of the variables that comprise the managed object UUID. The following table is an example of an SNMP table. The table contains variables that must occur in a definite sequence.
UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.2 Description Defines the index of the UUID in a specified chassis. Syntax DellObjectRange Access Read-only UUID Type Name uUIDType Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3 Description Defines the type of the UUID for this chassis. Syntax DellUUIDType Access Read-only UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4 Description Defines the value of the UUID for this chassis.
Table 1-8. Example Variable Type Definition Table Variable Name: DellFanControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The fan’s capabilities are unknown. lowSpeedCapable(2) The fan can be set to low speed. highSpeedCapable(4) The fan can be set to high speed. lowOrHighSpeedCapable(6) The fan can be set to low or high speed. This type of table is used throughout the reference guide to list and define variable values.
• IDE Control Table • Diskette Control Table • Network Interface Control Table 3 Variables that make up each table in the group This section documents the variables for the eight tables that comprise the BIOS group. 4 BIOS Variable Values This section explains any Server Administrator-specific variables and data types that are used in this section. In the BIOS group example, there are 17 unique, Server Administrator-specific variable meanings.
SNMP is a systems management standard originally designed for network management. SNMP manages much more than networks. Information Technology (IT) professionals use SNMP for monitoring and managing computer systems and the various components and peripherals supported by their systems. SNMP standards are defined by the Internet Engineering Task Force (IETF). SNMP version 1 was published in August 1988 and is the most commonly supported version of SNMP.
The assignment of values for each OID prefix component can be illustrated by using a tree structure. The following is an example of an OID assignment: ROOT CCITT(0) ISO(1) ORG(3) DOD(6) INTERNET(1) MGMT(2) MIB(1) EXPERIMENTAL(3) PRIVATE(4) ENTERPRISES(1) DELL(674) SNMPv2(6) In the preceding example, the OID prefix for the Dell enterprise would be 1.3.6.1.4.1.674. The numbers in boldface type show the categories and numbers that apply to Server Administrator.
Initiating Management Actions Management actions can be performed using the SNMP Set command. These actions can consist of configuring a phone number for the system’s owner, rebooting a system, or changing the asset tag of the system. See the previous section, "SNMP Security," for limitations on Set operations. SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on.
Instrumentation MIB Version Group The Instrumentation Management Information Base (MIB) Version Group defines the attributes that identify the version of the Instrumentation MIB supported by the systems management software. The mIBMajorVersionNumber, mIBMinorVersionNumber, and mIBMaintenanceVersionNumber attributes are scalar objects, meaning that they are not related to other MIB objects and are thus not placed in a table. MIB Major Version Number Name mIBMajorVersionNumber Object ID 1.3.6.1.4.1.674.
MIB Maintenance Version Number 30 Name mIBMaintenanceVersionNumber Object ID 1.3.6.1.4.1.674.10892.1.1.3.0 Description Defines the maintenance version number for the version of this MIB supported by the systems management software. For example, if the MIB version is 1.2.3, the maintenance version number is 3.
Systems Management Software Group The Systems Management Software Group allows users to see information about the standards and software that are supported by the agent of a particular managed computer chassis. The Systems Management Software Group classifies each computer chassis according to the systems management standard that the agent supports.
Systems Management Software Name Name systemManagementSoftwareName Object ID 1.3.6.1.4.1.674.10892.1.100.1 Description Defines the systems management software product name. Syntax DellString Access Read-only Systems Management Software Version Number Name Name systemManagementSoftwareVersionNumberName Object ID 1.3.6.1.4.1.674.10892.1.100.2 Description Defines the version number of the systems management software.
Systems Management Software Supported Protocol Name systemManagementSoftwareSupportedProtocol Object ID 1.3.6.1.4.1.674.10892.1.100.5 Description Defines the systems management standards (SNMP or CIM) supported by the systems management software. Syntax SMSSupportedTypes (See Table 3-1.) Access Read-only Systems Management Software Preferred Protocol Name systemManagementSoftwarePreferredProtocol Object ID 1.3.6.1.4.1.674.10892.1.100.
Systems Management Software Language Name Name systemManagementSoftwareLanguageName Object ID 1.3.6.1.4.1.674.10892.1.100.9 Description Defines the language of the systems management software. Syntax DisplayString (SIZE (0..255)) Access Read-only Systems Management Software Global Version Name Name systemManagementSoftwareGlobalVersionName Object ID 1.3.6.1.4.1.674.10892.1.100.10 Description Defines the global version of the systems management software.
Systems Management Software Manufacturer Name Name systemManagementSoftwareManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.100.13 Description Defines the manufacturer of the systems management software. Syntax DellString Access Read-only Systems Management Software Variable Values This section includes definitions of server administrator-specific variable values used in this section. Table 3-1.
Table 3-3. Systems Management Software SNMP Agent Feature Flags Variable Name: SMSSNMPAgentFeatureFlags Data Type: Integer 36 Possible Data Values Meaning of Data Value none(0) The Systems Management Software SNMP agent features are not enabled. supportsSparseTables(1) The SNMP agent supports sparse tables.
System State Group The Management Information Base (MIB) variables presented in this section enable you to track various attributes that describe the state of the critical components supported by your system. Components monitored under the System State Group include power supplies, AC power cords, AC power switches, and cooling devices, as well as temperature, fan, amperage, and voltage probes. System State Group Table The System State Group defines objects in the System State MIB table.
System State Chassis Index Name systemStatechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System State Global System Status Name systemStateGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.2 Description Defines the global system status of all chassis being monitored by this instrumentation instance.
System State Power Unit State Details Name systemStatePowerUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.5 Description Defines the state of all power units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific power unit. The first byte returned represents the state of the first power unit, the second byte returned represents the state of the second power unit, and so on.
System State Power Supply State Details Name systemStatePowerSupplyStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.8 Description Defines the state of all power supplies in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific power supply. The first byte returned represents the state of the first power supply, the second byte returned represents the state of the second power supply, and so on.
System State Voltage State Details Name systemStateVoltageStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.11 Description Defines the state of all voltage probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific voltage probe. The first byte returned represents the status of the first voltage probe, the second byte returned represents the status of the second voltage probe, and so on.
System State Amperage State Details Name systemStateAmperageStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.14 Description Defines the state of all current probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific current probe. The first byte returned represents the state of the first current probe, the second byte returned represents the state of the second current probe, and so on.
System State Cooling Unit State Details Name statesystemStateCoolingUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.17 Description Defines the state of all cooling units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling unit. The first byte returned represents the state of the first cooling unit, the second byte returned represents the state of the second cooling unit, and so on.
System State Cooling Device State Details Name systemStateCoolingDeviceStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.20 Description Defines the state of all cooling devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling device. The first byte returned represents the state of the first cooling device, the second byte returned represents the state of the second cooling device, and so on.
System State Temperature State Details Name systemStateTemperatureStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.23 Description Defines the state of all temperature probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific temperature probe. The first byte returned represents the state of the first temperature probe, the second byte returned represents the status of the second temperature probe, and so on.
System State Memory Device State Details Name systemStateMemoryDeviceStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.26 Description Defines the state of all memory devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of the specific memory device. The first byte returned represents the state of the first memory device, the second byte returned represents the status of the second memory device, and so on.
System State Chassis Intrusion State Details Name systemStateChassisIntrusionStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.29 Description Defines the intrusion state of all intrusion detection devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific intrusion detection device.
System State AC Power Switch State Details Name systemStateACPowerSwitchStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.32 Description Defines the individual state of all AC power switches in this chassis. The first byte returned represents the state of the first AC power switch, the second byte returned represents the state of the second AC power switch, and so on. Syntax OCTET STRING (SIZE(1..
System State AC Power Cord Status Combined Name systemStateACPowerCordStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.36 Description Defines the overall status of all AC power cords for any AC power switches in this chassis. Syntax DellStatus Access Read-only System State AC Power Cord Status Details Name systemStateACPowerCordStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
System State Redundant Memory Unit Status Details Name systemStateRedundantMemoryUnitStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.40 Description Defines the status of all redundant memory units in this chassis. The results are returned as a binary octet string, each byte of the octet string represents the status of the specific object. The first byte returned represents the status of the first object, and so on. The bytes have the same definition type as DellStatusRedundancy.
System State Cooling Unit Status Combined Name systemStateCoolingUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.44 Description Defines the combined status of all cooling units of this chassis. Syntax DellStatus Access Read-only System State Cooling Unit Status List Name systemStateCoolingUnitStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.45 Description Lists the status of each cooling unit of this chassis.
System State Redundant Memory Unit Status Combined Name systemStateRedundantMemoryUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.48 Description Defines the combined status of all redundant memory units of this chassis. Syntax DellStatus Access Read-only System State Redundant Memory Unit Status List Name systemStateRedundantMemoryUnitStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.49 Description Lists the status of each redundant memory unit of this chassis.
System State Battery Status Combined Name systemStateBatteryStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.52 Description Defines the combined status of all batteries of this chassis. Syntax DellStatus Access Read-only System State Battery Status List Name systemStateBatteryStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.53 Description Lists the status of each battery of this chassis.
System State Group
Chassis Information Group The Chassis Information Group provides information about the type or types of chassis in your system, as well as information about the light-emitting diode (LED) indicators and settings for devices on each chassis. Information is also available about the current date and time displayed on the chassis, intrusion warnings, watchdog timer, systems management basic input/output system (SMBIOS), and so on.
Chassis Information Table Entry Name chassisInformationTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.10.1 Description Defines the chassis information table entry. Syntax ChassisInformationTableEntry Access Not accessible Index chassisIndexChassisInformation Chassis Index Chassis Information Name chassisIndexChassisInformation Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.1 Description Defines the index (one-based) of this chassis. The first chassis will be numbered one.
Chassis Status Name chassisStatus Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4 Description Defines the status of the chassis. Syntax DellStatus Access Read-only Chassis Parent Index Reference Name chassisparentIndexReference Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4 Description Defines the index (one-based) of the parent chassis of this chassis, if any. A zero (0) means that this chassis is the parent of all other chassis managed by the Server Administrator.
Chassis Manufacturer Name Name chassisManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.8 Description Defines the manufacturer’s name for this chassis. Syntax DellString Access Read-only Chassis Model Name Name chassisModelName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.9 Description Defines the system model type for this chassis. Syntax DellString Access Read-only Chassis Asset Tag Name Name chassisAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Chassis ID Name chassisID Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.12 Description Defines the asset tag name for this chassis. Syntax DellUnsigned8BitRange Access Read-only Chassis ID Extension Name chassisIDExtension Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.13 Description Defines the SMBIOS machine ID of this chassis. Syntax DellUnsigned16BitRange Access Read-only Chassis System Class Name chassisSystemClass Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Chassis System Boot Date Name Name chassisSystemBootDateName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.16 Description Defines the boot time of this system. Syntax DellDateName Access Read-only Chassis System Date Name Name chassisSystemDateName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.17 Description Defines the current time on this system. Syntax DellDateName Access Read-only Chassis System Location Name Name chassisSystemLocationName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Chassis System User Phone Number Name Name chassisSystemUserPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.20 Description Defines the user-assigned phone number of the primary user of the system. Syntax DellString Access Read-write Chassis Connection Status Unique Name chassisConnectionStatusUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.21 Description Defines the status of the connection from the system chassis to an expansion chassis.
Chassis LED Control Capabilities Unique Name chassisLEDControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.24 Description Defines the capabilities of the LED control function in the chassis. Syntax DellLEDControlCapabilities (See Table 5-5.) Access Read-only Chassis LED Control Settings Unique Name chassisLEDControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.25 Description Defines the readings and settings of the LED control hardware in the chassis.
Chassis Identify Flash Control Capabilities Name chassisIdentifyFlashControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.28 Description Specifies whether the chassis front-panel LED can be set to flash. Syntax DellChassisIdentifyControlCapabilities (See Table 5-9.) Access Read-only Chassis Identify Flash Control Settings Name chassisIdentifyFlashControlSettings Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.29 Description Causes the chassis front-panel LED to flash.
Chassis Host Control Settings Unique Name chassishostControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.32 Description Defines the current settings of the host control object. Syntax DellHostControlSettings (See Table 5-12.) Access Read-write Chassis Watchdog Control Capabilities Unique Name chassiswatchDogControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.33 Description Defines the capabilities of the watchdog timer object.
Chassis Watchdog Control Expiry Time Name chassiswatchDogControlExpiryTime Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.36 Description Defines the current reading and allows setting of the nonrecoverable watchdog expiry timer object. Syntax DellUnsigned16BitRange Access Read-write Chassis Allow Set Commands From SNMP Name chassisallowSETCommandsfromSNMP Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Chassis Reseller Name Name chassisResellerName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.40 Description Defines the name of the chassis reseller. Syntax DisplayString (SIZE (0..128)) Access Read-only Chassis Reseller Contact Information Name Name chassisResellerContactInformationName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.41 Description Defines the chassis reseller contact information name. Syntax DisplayString (SIZE (0..
Chassis NMI Button Control Capabilities Unique Name chassisNMIButtonControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.44 Description Defines the capabilities of the NMI button control function. Syntax DellNMIButtonControlCapabilities (See Table 5-18) Access Read-only Chassis NMI Button Control Settings Unique Name chassisNMIButtonControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
UUID Chassis Index Name uUIDchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.2 Description Defines the index of the UUID in a specified chassis. Syntax DellObjectRange Access Read-only UUID Type Name uUIDType Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.
POST Log Table This section defines attributes for the power-on self-test (POST) log. When you turn on your computer, the POST checks various system components before the operating system loads. The POST tests the random-access memory (RAM), the hard drives, and the keyboard, for example. While the POST is running, it makes a log file that system administrators can view. The variables in this section also contribute to managing the POST log. Name postLogTable Object ID 1.3.6.1.4.1.674.10892.1.300.
POST Log State Capabilities Unique Name postLogStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.3 Description Defines the capabilities of the object that is writing the POST log. Syntax DellStateCapabilitiesLogUnique Access Read-only POST Log State Settings Unique Name postLogStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.4 Description Defines the state of the object that is writing the POST log.
Event Log Table Name eventLogTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.40 Description Defines the Event Log Table. Syntax SEQUENCE OF EventLogTableEntry Access Not accessible Event Log Table Entry Name eventLogTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.40.1 Description Defines the event Log Table Entry. Syntax EventLogTableEntry Access Not accessible Index eventLogchassisIndex,eventLogRecordIndex Event Log Chassis Index Name eventLogchassisIndex Object ID 1.3.6.1.4.1.
Event Log State Capabilities Unique Name eventLogStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.3 Description Defines the capabilities of the object that is writing the event log. Syntax DellStateCapabilitiesLogUnique Access Read-only Event Log State Settings Unique Name eventLogStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.4 Description Defines the state settings for the object that is writing the event log.
Event Log Severity Status Name eventLogSeverityStatus Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.7 Description Defines the severity of the event log record. Syntax DellStatus Access Read-only Status Mandatory Event Log Date Name Name eventLogDateName Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.8 Description Defines the date and time of the event log record.
System BIOS Chassis Index Name systemBIOSchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System BIOS Index Name systemBIOSIndex Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.2 Description Defines the index (one-based) of the system BIOS of this object. Syntax DellObjectRange Access Read-only System BIOS State Capabilities Name systemBIOSStateCapabilities Object ID 1.3.6.1.4.1.674.
System BIOS Status Name systemBIOSStatus Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.5 Description Defines the status of the system BIOS of this object. Syntax DellStatus Access Read-only System BIOS Size Name systemBIOSSize Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.6 Description Defines the image size of the system BIOS in kilobytes (KB). A zero (0) indicates that the image size of the BIOS is unknown.
System BIOS Starting Address Name systemBIOSStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.9 Description Defines the starting address of the system BIOS. A zero (0) indicates that the address is unknown. Syntax DellUnsigned64BitRange Access Read-only System BIOS Ending Address Name systemBIOSEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.10 Description Defines the ending address of the system BIOS. A zero (0) indicates that the address is unknown.
System BIOS Characteristics Name systemBIOSCharacteristics Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.12 Description Defines characteristics of the system BIOS. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one). Bit 63 is the first bit in the value, and bit 0 is the last bit in the value. See the description of DellUnsigned64BitRange at the beginning of this file for more information on the format of the value.
Name systemBIOSCharacteristics Description Bit Position Meaning if Set -------------- -----------------Bit 29 Bit 30 Bit 31 Bit 32-47 Bit 48 Bit 49 Bit 50 Bit 51 Bit 52 Bit 53-63 Syntax Int 17h, Printer Services are supported Int 10h, CGA/Mono Video Services are supported NEC PC-98 Reserved Built-in NIC supports Magic Packet System supports Wake-on-LAN System supports chassis intrusion Built-in NIC supports pattern-matching System BIOS supports a 7-character service tag Reserved DellUnsigned64BitRange
System BIOS Characteristics Ext 2 Name systemBIOSCharacteristicsExt2 Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.14 Description Defines additional characteristics of the system BIOS. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
Firmware Chassis Index Name firmwarechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Firmware Index Name firmwareIndex Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.2 Description Defines the index (one-based) of the firmware in this chassis. Syntax DellObjectRange Access Read-only Firmware State Capabilities Name firmwareStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.
Firmware Status Name firmwareStatus Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.5 Description Defines the status of the firmware. Syntax DellStateSettings Access Read-only Firmware Size Name firmwareSize Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.6 Description Defines the image size of the firmware in KB. A zero (0) indicates that the size is unknown. Syntax DellUnsigned16BitRange Access Read-only Firmware Type Name firmwareType Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.
Firmware Update Capabilities Name firmwareUpdateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.9 Description Defines the bitmap of supported methods for firmware update. Syntax DellUnsigned16BitRange Access Read-only Firmware Date Name Name firmwareDateName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.10 Description Defines the date of the firmware. Syntax DellDateName Access Read-only Firmware Version Name Name firmwareVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.
Intrusion Table Entry Name intrusionTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.70.1 Description Defines the Intrusion Table entry. Syntax IntrusionTableEntry Access Not accessible Index intrusionchassisIndex, intrusionIndex Intrusion Chassis Index Name intrusionchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Intrusion Index Name intrusionIndex Object ID 1.3.6.1.4.1.674.
Intrusion State Settings Name intrusionStateSettings Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.4 Description Defines the settings of the intrusion object. Syntax DellStateSettings Access Read-write Intrusion Status Name intrusionStatus Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.5 Description Defines the status of the intrusion object. Syntax DellStatus Access Read-only Intrusion Reading Name intrusionReading Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.
Intrusion Location Name Name intrusionLocationName Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.8 Description Defines the location name of the intrusion object in this subgroup. Syntax DellString Access Read-only Baseboard Table This table lists objects that define the baseboard of a system. Name baseBoardTable Object ID 1.3.6.1.4.1.674.10892.1.300.80 Description Defines the Baseboard Table.
Baseboard Index Name baseBoardIndex Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.2 Description Defines the index (one-based) of the base board. Syntax DellObjectRange Access Read-only Baseboard State Capabilities Name baseBoardStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.3 Description Defines the state capabilities of the baseboard. Syntax DellStateCapabilities Access Read-only Baseboard State Settings Name baseBoardStateSettings Object ID 1.3.6.1.4.1.674.10892.1.300.80.
Baseboard Feature Flags Name baseBoardFeatureFlags Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.6 Description Defines the features of the baseboard. Syntax DellBaseBoardFeatureFlags Access Read-only Baseboard Type Name baseBoardType Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.7 Description Defines the type of the baseboard. Syntax DellBaseBoardType Access Read-only Baseboard Type Name Name baseBoardTypeName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.
Baseboard Manufacturer Name Name baseBoardManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.10 Description Defines the baseboard manufacturer’s name. Syntax DellString Access Read-only Baseboard Product Name Name baseBoardProductName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.11 Description Defines the baseboard product’s name. Syntax DellString Access Read-only Baseboard Version Name Name baseBoardVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.
Baseboard Piece Part ID (PPID) Name Name baseBoardPiecePartIDName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.14 Description Defines the baseboard PPID. Syntax DellString Access Read-only Baseboard Asset Tag Name Name baseBoardAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.15 Description Defines the baseboard asset tag name.
Table 5-2. Chassis Type Variable Name: DellChassisType Data Type: Integer 90 Possible Data Values Meaning of Data Value other(1) The chassis type is not one of the following: unknown(2) The chassis type is unknown. desktop(3) The chassis type is a desktop. lowProfileDesktop(4) The chassis type is a low-profile desktop. pizzaBox(5) The chassis type is a pizza box. miniTower(6) The chassis type is a minitower. tower(7) The chassis type is a tower.
Table 5-3. Connection Status Variable Name: DellConnectionStatus Data Type: Integer Possible Data Values Meaning of Data Value unknown(2) The status of the chassis connection is unknown. ok(3) The status of the chassis connection is OK. failure(4) The status of the chassis connection is failure. Table 5-4. Fan Control Capabilities Variable Name: DellFanControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The fan’s capabilities are unknown.
Table 5-6. Front-Panel LED Control Settings Variable Name: DellLEDControlSettings Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The LED control setting is unknown. alertOnError(2) The LED control is set to alert on an error condition. alertOnWarningAndError(4) The LED control is set to alert on an error or a warning condition. Table 5-7.
Table 5-9. Chassis Identification Control Capabilities Variable Name: DellChassisIdentifyControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The LEDs do not have any chassis identification capabilities. unknownCapabilities(1) The chassis identification control’s capabilities are unknown. enableCapable(2) The chassis identification controls can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).
Table 5-11. Host Control Capabilities Variable Name: DellHostControlCapabilities NOTE: An operator can manually cause these actions using SNMP. Data Type: Integer Possible Data Values Meaning of Data Value manualRebootCapable(1) The operator can reboot capable host. manualPowerOFFCapable(2) The operator can power off capable host. manualPowerCycleCapable(4) The operator can power-cycle capable host. manualAllExceptOperatingSystemShutdown The operator can reboot and power off capable host.
Table 5-13. Watchdog Control Capabilities Variable Name: DellWatchDogControlCapabilities NOTE: When the system determines that the operating system is not responding, it will automatically perform the selected action without operator intervention. Data Type: Integer Possible Data Values Meaning of Data Value automaticRebootCapable(1) Watchdog controls can be set to reboot capable host. automaticPowerCycleCapable(2) Watchdog controls can be set to power cycleable capable host.
Table 5-15. Watchdog Timer Capabilities Variable Name: DellWatchDogTimerCapabilities Data Type: Integer Possible Data Values Meaning of Data Value type1Capable(1) Watchdog timer can time in intervals from 20–480 seconds. type2Capable(2) Watchdog timer can time in 30-, 60-, 120-, and 480-second intervals. type3Capable(4) Watchdog timer can time in 60-second intervals. Table 5-16.
Table 5-18. NMI Button Control Capabilities Variable Name: DellNMIButtonControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The NMI button has no capabilities. unknownCapabilities(1) The NMI button capabilities are unknown. enableCapable(2) The NMI button can be enabled (online) or disabled (offline). Table 5-19.
Table 5-21. Firmware Type Variable Name: DellFirmwareType Data Type: Integer Possible Data Values Meaning of Data Value other(1) The firmware type is other than following values. unknown(2) The firmware type is unknown. systemBIOS(3) The firmware type is System BIOS embeddedSystemManagementController(4) The firmware type is Embedded System Management Controller. 98 powerSupplyParallelingBoard(5) The firmware type is Power Supply Paralleling Board.
Table 5-22. Baseboard Type Variable Name: DellBaseBoardType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The baseboard type is unknown. other(2) The baseboard type is not one of the following types. serverBlade(3) The baseboard type is a server blade. connectivitySwitch(4) The baseboard type is a connectivity switch. systemManagementModule(5) The baseboard type is a system management module. processorModule(6) The baseboard type is a processor module.
Chassis Information Group
Operating System Group The Operating System Group provides status and identifying information about a system’s operating system. Identifying information includes the name, version, service pack, and patch level of the installed operating system.
Operating System State Capabilities Name operatingSystemStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.2 Description Defines the capabilities of the operating system. Syntax DellStateCapabilities Access Read-only Operating System State Settings Name operatingSystemStateSettings Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.3 Description Defines the state of the operating system.
Operating System Name Name operatingSystemOperatingSystemName Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.6 Description Defines the name of the operating system running on the system. Syntax DellString Access Read-only Operating System Version Name Name operatingSystemOperatingSystemVersionName Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.7 Description Defines the version of the operating system running on the system.
Operating System Memory Chassis Index Name operatingSystemMemorychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellStateCapabilities Access Read-only Operating System Memory State Capabilities Name operatingSystemMemoryStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.2 Description Defines the capabilities of the operating system memory.
Operating System Total Physical Size Name operatingSystemMemoryTotalPhysicalSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.5 Description Defines the total physical memory size in bytes. Syntax DellUnsigned32BitRange Access Read-only Operating System Memory Available Physical Size Name operatingSystemMemoryAvailblePhysicalSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.6 Description Defines the available physical memory size in bytes.
Operating System Memory Total Virtual Size Name operatingSystemMemoryTotalVirtualSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.9 Description Defines the total virtual memory size in bytes. Syntax DellUnsigned32BitRange Access Read-only Operating System Memory Available Virtual Size 106 Name operatingSystemMemoryAvailableVirtualSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.10 Description Defines the available virtual memory size in bytes.
System Resource Group The Management Information Base (MIB) variables presented in this section enable you to track various attributes of your system resources. This section includes System Resource Group Tables that track variables such as the owner, ports, system memory, interrupts, and direct memory access.
System Resource Map Chassis Index Name systemResourceMapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System Resource Map Index Name systemResourceMapIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.2 Description Defines the index of system resource maps in this chassis.
System Resource Map Status Name systemResourceMapStatus Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.5 Description Defines the status of this system map. Syntax DellStatus Access Read-only System Resource Map Type Name systemResourceMapType Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.6 Description Defines the type of this system map. Syntax DellSystemResourceMapType (See Table 7-1.) Access Read-only System Resource Owner Table Name systemResourceOwnerTable Object ID 1.3.6.1.4.1.674.
System Resource Owner Chassis Index Name systemResourceOwnerchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System Resource Owner Index Name systemResourceOwnerIndex Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.2 Description Defines the index of system resource owners for this chassis.
System Resource Owner Status Name systemResourceOwnerStatus Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.5 Description Defines the status of this system resource owner. Syntax DellStatus Access Read-write System Resource Owner Interface Type Name systemResourceOwnerInterfaceType Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.6 Description Defines the interface type for this system resource owner. Syntax DellResourceOwnerInterfaceType (See Table 7-2.
System Resource Owner Interface Instance Name systemResourceOwnerInterfaceInstance Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.9 Description Defines the associated system resource owner interface instance in this chassis. Syntax DellObjectRange Access Read-only System Resource Input/Output (I/O) Port Table Name systemResourceIOPortTable Object ID 1.3.6.1.4.1.674.10892.1.500.30 Description Defines the System Resource I/O Port Table.
System Resource I/O Port Index Name systemResourceIOPortIndex Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.2 Description Defines the index (one-based) of the system resource I/O ports in this chassis. Syntax DellObjectRange Access Read-only System Resource I/O Port State Capabilities Name systemResourceIOPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.3 Description Defines the capabilities of the system resource I/O port.
System Resource I/O Port Owner Index Reference Name systemResourceIOPortOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.6 Description Defines the index to the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only System Resource I/O Port Share Disposition Name systemResourceIOPortShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.7 Description Defines the share disposition of the system resource I/O port.
System Resource Memory Table Name systemResourceMemoryTable Object ID 1.3.6.1.4.1.674.10892.1.500.40 Description Defines the System Resource Memory Table. Syntax SEQUENCE OF SystemResourceMemoryTableEntry Access Not accessible System Resource Memory Table Entry Name systemResourceMemoryTableEntry Object ID 1.3.6.1.4.1.674.10892.1.500.40.1 Description Defines the System Resource Memory Table entry.
System Resource Memory State Capabilities Name systemResourceMemoryStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.3 Description Defines the capabilities of this system resource memory. Syntax DellObjectRange Access Read-only System Resource Memory State Settings Name systemResourceMemoryStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.4 Description Defines the state of this system resource memory.
System Resource Memory Share Disposition Name systemResourceMemoryShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.7 Description Defines the share disposition of the system resource memory. Syntax DellResourceShareDisposition (See Table 7-3.) Access Read-only System Resource Memory Starting Address Name systemResourceMemoryStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.8 Description Defines the 64 bits of the starting address of the system resource memory.
System Resource Interrupt Table Name systemResourceInterruptTable Object ID 1.3.6.1.4.1.674.10892.1.500.50 Description Defines the System Resource Interrupt Table. Syntax SEQUENCE OF SystemResourceInterruptTableEntry Access Not accessible System Resource Interrupt Table Entry Name systemResourceInterruptTableEntry Object ID 1.3.6.1.4.1.674.10892.1.500.50.1 Description Defines the System Resource Interrupt Table entry.
System Resource Interrupt State Capabilities Name systemResourceInterruptStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.3 Description Defines the capabilities of this system resource interrupt. Syntax DellStateCapabilities Access Read-only System Resource Interrupt State Settings Name systemResourceInterruptStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.4 Description Defines the state of this system resource interrupt.
System Resource Interrupt Owner Share Disposition Name systemResourceInterruptShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.7 Description Defines the share disposition of the system resource interrupt. Syntax DellResourceShareDisposition (See Table 7-3.) Access Read-only System Resource Interrupt Level Name systemResourceInterruptLevel Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.8 Description Defines the interrupt request (IRQ) level of the system resource interrupt.
System Resource Direct Memory Access (DMA) Table Name systemResourceDMATable Object ID 1.3.6.1.4.1.674.10892.1.500.60 Description Defines the System Resource DMA Table. Syntax SEQUENCE OF SystemResourceDMATableEntry Access Not accessible System Resource DMA Table Entry Name systemResourceDMATable Object ID 1.3.6.1.4.1.674.10892.1.500.60.1 Description Defines the System Resource DMA Table entry.
System Resource DMA State Capabilities Name systemResourceDMAStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.3 Description Defines the capabilities of this system resource DMA. Syntax DellStateCapabilities Access Read-only System Resource DMA State Settings Name systemResourceDMAStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.4 Description Defines the state and setting of this system resource DMA.
System Resource DMA Share Disposition Name systemResourceDMAShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.7 Description Defines the share disposition of the system resource DMA. Syntax DellResourceShareDisposition (See Table 7-3.) Access Read-only System Resource DMA Maximum Transfer Size Name systemResourceDMAMaximumTransferSize Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.8 Description Defines the maximum size of a memory transfer in bytes for the system resource DMA.
System Resource Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 7-1. System Resource Map Type Variable Name: DellSystemResourceMapType Data Type: Integer Possible Data Values Meaning of Data Value other(1) The system resource map type is not one of the following: unknown(2) The system resource map type is unknown (not known or not monitored). typeOne(3) The system resource map is type 1 (one). Table 7-2.
Table 7-3. Resource Share Disposition Variable Name: DellResourceShareDisposition Data Type: Integer Possible Data Values Meaning of Data Value shareIsOther(1) The share disposition is not one of the following: shareIsUnknown(2) The share disposition is unknown (not known or not monitored). shareIsDeviceExclusive(3) The share disposition is device exclusive. shareIsDriverExclusive(4) The share disposition is driver exclusive. shareIsShared(5) The share disposition is shared. Table 7-4.
Table 7-6. Resource Interrupt Trigger Variable Name: DellResourceInterruptTrigger Data Type: Integer Possible Data Values Meaning of Data Value interruptIsActiveWhenLow(1) The interrupt trigger is active on a low signal. interruptIsActiveWhenHigh(2) The interrupt trigger is active on a high signal. Table 7-7.
Power Group The Power Group provides information about power units (a group of power supplies in a system chassis), power supplies, and voltage and amperage probes. Power Group Tables The following management information base (MIB) tables define objects for the Power Group: • Power Unit Table • Power Supply Table • Voltage Probe Table • Amperage Probe Table • AC Power Switch Table • AC Power Cord Table • Battery Table Power Unit Table Name powerUnitTable Object ID 1.3.6.1.4.1.674.10892.1.
Power Unit Chassis Index Name powerUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Power Unit Index Name powerUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.2 Description Defines the index of the power unit in this chassis. Syntax DellObjectRange Access Read-only Power Unit State Capabilities Name powerUnitStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.
Power Unit Redundancy Status Name powerUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.5 Description Defines the redundancy status of the power unit. Syntax DellStatusRedundancy Access Read-only Power Supply Count for Redundancy Name powerSupplyCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.6 Description Defines the total number of power supplies required for this power unit to have redundancy.
Power Supply Table Name powerSupplyTable Object ID 1.3.6.1.4.1.674.10892.1.600.12 Description Defines the Power Supply Table. Syntax PowerSupplyTableEntry Access Not accessible Power Supply Table Entry Name powerSupplyTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.12.1 Description Defines the Power Supply Table entry.
Power Supply State Capabilities Unique Name powerSupplyStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.3 Description Defines the capabilities of the power supply. Syntax DellPowerSupplyStateCapabilitiesUnique (See Table 8-1.) Access Read-only Power Supply State Settings Unique Name powerSupplyStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.4 Description Defines the state and settings of the power supply.
Power Supply Type Name powerSupplyType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.7 Description Defines the type of power supply. Syntax DellPowerSupplyType (See Table 8-3.) Access Read-only Power Supply Location Name Name powerSupplyLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.8 Description Defines the location name of the power supply. Syntax DellString Access Read-only Power Supply Input Voltage Name powerSupplyInputVoltage Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.
Power Supply Sensor State Name powerSupplySensorState Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.11 Description Defines the state reported by the power supply sensor, and supplements the state and settings of the power supply. Syntax DellPowerSupplySensorState (See Table 8-4) Access Read-only Power Supply Configuration Error Type Name powerSupplyConfigurationErrorType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.
Voltage Probe Chassis Index Name voltageProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Voltage Probe Index Name voltageProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.2 Description Defines the index of voltage probes in this chassis. Syntax DellObjectRange Access Read-only Voltage Probe State Capabilities Name voltageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.
Voltage Probe Status Name voltageProbeStatus Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.5 Description Defines the status of the voltage probe. Syntax DellStatusProbe Access Read-only Voltage Probe Reading Name voltageProbeReading Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.6 Description Defines the value of the voltage probe reading. The value is an integer representing the voltage in millivolts that the probe is reading.
Voltage Probe Upper Nonrecoverable Threshold Name voltageProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.9 Description Defines the value of the voltage probe’s upper nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Voltage Probe Upper Critical Threshold Name voltageProbeUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.10 Description Defines the value of the voltage probe’s upper critical threshold.
Voltage Probe Lower Critical Threshold Name voltageProbeLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.13 Description Defines the value of the voltage probe’s lower critical threshold. Syntax DellSigned32BitRange Access Read-only Voltage Probe Lower Nonrecoverable Threshold Name voltageProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.14 Description Defines the value of the voltage probe’s lower nonrecoverable threshold.
Amperage Probe Table Name amperageProbeTable Object ID 1.3.6.1.4.1.674.10892.1.600.30 Description Defines the Amperage Probe Table. Syntax SEQUENCE OF AmperageProbeTableEntry Access Not accessible Amperage Probe Table Entry Name amperageProbeTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.30.1 Description Defines the Amperage Probe Table entry.
Amperage Probe State Capabilities Name amperageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.3 Description Defines the capabilities of the amperage probe. Syntax DellStateCapabilities Access Read-only Amperage Probe State Settings Name amperageProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.4 Description Defines the state and settings of the amperage probe.
Amperage Probe Type Name amperageProbeType Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.7 Description Defines the type of the amperage probe. Syntax DellAmperageProbeType Access Read-only Amperage Probe Location Name Name amperageProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.8 Description Defines the location name of the amperage probe in this chassis.
Amperage Probe Upper Noncritical Threshold Name amperageProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.11 Description Defines the user-assigned value of the amperage probe’s upper critical threshold. Syntax DellSigned32BitRange Access Read-write Amperage Probe Lower Noncritical Threshold Name amperageProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.
Amperage Probe Probe Capabilities Name amperageProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.15 Description Defines the probe capabilities of the amperage probe. Syntax DellProbeCapabilities Access Read-only Amperage Probe Discrete Reading Name amperageProbeDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.16 Description Defines the reading for a amperage probe of type amperageProbeTypeIsDiscrete.
AC Power Switch Chassis Index Name aCPowerSwitchChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.1 Description Defines the index (one-based) of the chassis containing this AC power switch. Syntax DellObjectRange Access Read-only AC Power Switch Index Name aCPowerSwitchIndex Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.2 Description Defines the index (one-based) of this AC power switch.
AC Power Switch Redundancy Status Name aCPowerSwitchRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.5 Description Defines the redundancy status of this AC power switch. Syntax DellStatusRedundancy Access Read-only AC Power Cord Count for Redundancy Name aCPowerCordCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.6 Description Defines the total number of AC power cords required for this AC power switch to have redundancy.
AC Power Switch Status Name aCPowerSwitchStatus Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.9 Description Defines the status of this AC power switch. Syntax DellStatus Access Read-only AC Power Cord Table Name aCPowerCordTable Object ID 1.3.6.1.4.1.674.10892.1.600.42 Description Defines the AC Power Cord Table. Syntax SEQUENCE OF ACPowerCordTableEntry Access Not accessible AC Power Cord Table Entry Name aCPowerCordTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.42.
AC Power Cord Index Name aCPowerCordIndex Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.2 Description Defines the index (one-based) of this AC power cord. Syntax DellObjectRange Access Read-only AC Power Cord State Capabilities Name aCPowerCordStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.3 Description Defines the capabilities of this AC power cord.
AC Power Cord AC Power Switch Index Reference Name aCPowerCordaCPowerSwitchIndexReference Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.6 Description Defines the index (one-based) to the associated AC power switch for this AC power cord. Syntax DellObjectRange Access Read-only AC Power Cord Location Name Name aCPowerCordLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.7 Description Defines the location name of this AC power cord.
Battery Chassis Index Name batteryChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.1 Description Defines the index (one-based) of the chassis that contains the battery. Syntax DellObjectRange Access Read-only Battery Index Name batteryIndex Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.2 Description Defines the index (one-based) of the battery. Syntax DellObjectRange Access Read-only Battery State Capabilities Name batteryStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.50.
Battery Status Name batteryStatus Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.5 Description Defines the status of the battery. Syntax DellStatus Access Read-only Battery Reading Name batteryReading Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.6 Description Defines the reading of the battery. Syntax DellBatteryReading (see Table ) Access Read-only Battery Location Name Name batteryLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.7 Description Defines the location of the battery.
Table 8-2. Power Supply State Settings Unique Variable Name: DellPowerSupplyStateSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The power supply’s capabilities are unknown. onLine(2) The power supply’s state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReady(4) The power supply’s state is not ready. fanFailure(8) The power supply fan has failed.
Table 8-3. Power Supply Type Definitions (continued) Variable Name: DellPowerSupplyType Data Type: Integer Possible Data Values Meaning of Data Value powerSupplyTypeIsConverter(7) The power supply type is a power converter power supply. powerSupplyTypeIsRegulator(8) The power supply type is a regulator power supply. powerSupplyTypeIsAC(9) The power supply type is an AC power supply. powerSupplyTypeIsDC(10) The power supply type is a DC power supply.
Table 8-6. Voltage Probe Type Variable Name: DellVoltageType Data Type: Integer Possible Data Values Meaning of Data Value voltageProbeTypeIsOther(1) The voltage probe type is not one of the following: voltageProbeTypeIsUnknown(2) The voltage probe type is unknown (not known or not monitored). voltageProbeTypeIs1Point5Volt(3) The voltage probe type is a 1.5-volt (V) probe. voltageProbeTypeIs3Point3Volt(4) The voltage probe type is a 3.3-V probe.
Table 8-8. Amperage Probe Definitions Variable Name: DellAmperageType Data Type: Integer Possible Data Values Meaning of Data Value amperageProbeTypeIsOther(1) The amperage probe type is not one of the following: amperageProbeTypeIsUnknown(2) The amperage probe type is unknown (not known or not monitored). amperageProbeTypeIs1Point5Volt(3) The amperage probe type is a 1.5-ampere (A) probe. amperageProbeTypeIs3Point3volt(4) The amperage probe type is a 3.3-A probe.
Table 8-10. AC Power Switch Capabilities Variable Name: DellACPowerSwitchCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknownCapabilities(1) The AC power switch’s capabilities are unknown. inputSourceCord1NoReturnCapable(2) Input source is AC power cord 1, with no return. inputSourceCord1ReturnCapable(4) Input source is AC power cord 1, with return. inputSourceCord2NoReturnCapable(8) Input source is AC power cord 2, with no return.
Table 8-13. AC Power Cord State Capabilities Variable Name: DellACPowerCordStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The AC power cord’s capabilities are unknown. onlineCapable(2) The AC power cord can be disabled (offline) or enabled (online). notReadyCapable(4) The AC power cord’s capabilities are not ready. Table 8-14.
Power Group
Thermal Group The Thermal Group provides information about cooling units, cooling devices, and temperature probes. Cooling units are sets of fans or other cooling devices in a system chassis. Thermal Group variables include threshold values and types of cooling devices and temperature probes.
Cooling Unit Chassis Index Name coolingUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.1 Description Defines the index (one-based) of this chassis. Syntax TableEntry Access Read-only Cooling Unit Index Name coolingUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.2 Description Defines the index (one-based) of cooling units. Syntax DellObjectRange Access Read-only Cooling Unit State Capabilities Name coolingUnitStateCapabilties Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.
Cooling Unit Redundancy Status Name coolingUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.5 Description Defines the redundancy status of the cooling unit. Syntax DellStatusRedundancy Access Read-only Cooling Device Count For Redundancy Name coolingDeviceCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.6 Description Defines the total number of cooling devices required for this cooling unit to have redundancy.
Cooling Device Table Name coolingDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.700.12 Description Defines the Cooling Device Table. Syntax CoolingDeviceTableEntry Access Not accessible Cooling Device Table Entry Name coolingDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.12.1 Description Defines the Cooling Device Table entry.
Cooling Device State Capabilities Name coolingDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.3 Description Defines the capabilities of the cooling device. Syntax DellStateCapabilities Access Read-only Cooling Device State Settings Name coolingDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.4 Description Defines the state and settings of the cooling device.
Cooling Device Type Name coolingDeviceType Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.7 Description Defines the cooling device type. Syntax DellCoolingDeviceType (See Table 9-1.) Access Read-only Cooling Device Location Name Name coolingDeviceLocationName Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.8 Description Defines the location of the cooling device in this chassis.
Cooling Device Upper Noncritical Threshold Name coolingDeviceUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.11 Description Defines the user-assigned value of the fan’s upper noncritical threshold. Syntax DellSigned32BitRange Access Read-write Cooling Device Lower Noncritical Threshold Name coolingDeviceLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.12 Description Defines the user-assigned value of the fan’s lower noncritical threshold.
Cooling Device Cooling Unit Index Reference Name coolingDevicecoolingUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.15 Description Defines the index for the associated system cooling unit in this chassis. Syntax DellObjectRange Access Read-only Cooling Device Subtype Name coolingDeviceSubType Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.16 Description Defines the cooling device subtype. Syntax DellCoolingDeviceSubType (See Table 9-2.
Temperature Probe Table Name temperatureProbeTable Object ID 1.3.6.1.4.1.674.10892.1.700.20 Description Defines the Temperature Probe Table. Syntax TemperatureProbeTableEntry Access Not accessible Temperature Probe Table Entry Name temperatureProbeTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.20.1 Description Defines the Temperature Probe Table entry.
Temperature Probe State Capabilities Name temperatureProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.3 Description Defines the capabilities of the temperature probe. Syntax DellStateCapabilities Access Read-only Temperature Probe State Settings Name temperatureProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.4 Description Defines the state and settings of the temperature probe.
Temperature Probe Type Name temperatureProbeType Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.7 Description Defines the temperature probe type. Syntax DellTemperatureProbeType (See Table 9-4.) Access Read-only Temperature Probe Location Name Name temperatureProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.8 Description Defines the location of the temperature probe in this chassis.
Temperature Probe Upper Noncritical Threshold Name temperatureProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.11 Description Defines the user-assigned value of the temperature probe’s upper noncritical threshold. Syntax DellSigned32BitRange Access Read-write Temperature Probe Lower Noncritical Threshold Name temperatureProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
Temperature Probe Probe Capabilities Name temperatureProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.15 Description Defines the probe capabilities of the temperature probe. Syntax DellProbeCapabilities Access Read-only Temperature Probe Discrete Reading Name temperatureProbeDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.16 Description Defines the reading for a temperature probe of type temperatureProbeTypeIsDiscrete.
Table 9-1. Cooling Device Type (continued) Variable Name: DellCoolingDeviceType Data Type: Integer Possible Data Values Meaning of Data Value coolingDeviceTypeIsAPowerSupplyFan(7) The cooling device type is a power supply fan. coolingDeviceTypeIsAHeatPipe(8) The cooling device type is a heat pipe. coolingDeviceTypeIsRefrigeration(9) The cooling device type is an integrated refrigeration unit. coolingDeviceTypeIsActiveCooling(10) The cooling device type is an active cooling device.
Table 9-4. Temperature Probe Type Variable Name: DellTemperatureProbeType Data Type: Integer Possible Data Values Meaning of Data Value temperatureProbeTypeIsOther(1) The temperature probe subtype is not one of the following: temperatureProbeTypeIsUnknown(2) The temperature probe subtype is unknown (not known or not monitored). temperatureProbeTypeIsAmbientESM(3) The temperature probe is for ambient Embedded Systems Management (ESM).
Thermal Group
User Security Group The User Security Table defines the objects that allow administrators to create and modify user accounts and to control which users can perform Set operations on managed systems. User Security Group Table The User Security Group defines objects in the User Security MIB table. User Security Table The following object sets up the User Security Table: Name userSecurityTable Object ID 1.3.6.1.4.1.674.10892.1.
User Security Index Name userSecurityIndex Object ID 1.3.6.1.4.1.674.10892.1.800.1.2 Description Defines the user security index. Syntax DellObjectRange Access Read-only User Security User Name Name userSecurityUserName Object ID 1.3.6.1.4.1.674.10892.1.800.1.3 Description Defines the user security user name. Syntax DellSecurityString Access Read-only User Security Control Name Name userSecurityControlName Object ID 1.3.6.1.4.1.674.10892.1.800.1.
Remote Flash BIOS Group The Remote Flash Basic Input/Output System (BIOS) Table defines the variables used to remotely update the BIOS in a system. The variables also define the capabilities of BIOS updates on the system. Remote Flash BIOS Group Table The Remote Flash BIOS Group defines objects in the Remote Flash BIOS MIB table. Remote Flash BIOS Table The following object sets up the Remote Flash BIOS Table: Name remoteFlashBIOSTable Object ID 1.3.6.1.4.1.674.10892.1.900.
Remote Flash BIOS Chassis Index Name remoteFlashBIOSchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Remote Flash BIOS Index Name remoteFlashBIOSIndex Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.2 Description Defines the index to the remote BIOS update hardware on this system.
Remote Flash BIOS Status Name remoteFlashBIOSStatus Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.5 Description Defines the status of the remote BIOS update hardware on this system. Syntax DellRemoteFlashBIOSStateStatus Access Read-only Remote Flash BIOS Last BIOS Date Name Name remoteFlashBIOSLastBIOSDateName Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.6 Description Defines the date of the last BIOS update.
Remote Flash BIOS Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 11-1. Remote Flash BIOS State Capabilities Unique Variable Name: DellRemoteFlashBIOSStateCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The remote flash BIOS’s capabilities are unknown. enableCapable(2) The remote flash BIOS can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).
Table 11-3. Remote Flash BIOS Completion Code Variable Name: DellRemoteFlashBIOSCompletionCode Data Type: Integer Possible Data Values Meaning of Data Value completionCodeIsOther(1) The completion code status is not one of the following: completionCodeIsUnknown(2) The completion code is unknown (not known or not monitored). completionCodeIsOK(3) This completion code completed successfully. completionCodeIsBadImage(4) This completion code is a bad flash BIOS image.
Remote Flash BIOS Group
Port Group The Port Group provides information about the different types of ports that may be present in your system. This management information base (MIB) group also provides information about the capabilities, states, and settings that are possible for each port.
Pointing Port Table Entry Name pointingPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1 Description Defines the Pointing Port Table entry. Syntax PointingPortTableEntry Access Not accessible Index pointingPortchassisIndex, pointingPortIndex Pointing Port Chassis Index Name pointingPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.1 Description Defines the index (one-based) of this chassis.
Pointing Port State Settings Name pointingPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.10.4 Description Defines the state and settings of the pointing port. Syntax DellStateSettings Access Read-write Pointing Port Status Name pointingPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.10.5 Description Defines the status of the pointing port. Syntax DellStatus Access Read-only Pointing Port Security State Name pointingPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.
Pointing Port Name Name pointingPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.10.8 Description Defines the name of the pointing port. Syntax DellString Access Read-only Pointing Port BIOS Connector Type Name pointingPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.10.9 Description Defines the basic input/output system (BIOS) connector type of the pointing port. Syntax DellGenericPortConnectorType Access Read-only Keyboard Port Table Name keyboardPortTable Object ID 1.3.
Keyboard Port Chassis Index Name keyboardPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Keyboard Port Index Name keyboardPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.2 Description Defines the index of the keyboard ports in this chassis. Syntax DellObjectRange Access Read-only Keyboard Port State Capabilities Name keyboardPortStateCapabilities Object ID 1.3.6.1.4.
Keyboard Port Status Name keyboardPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.5 Description Defines the status of the keyboard port. Syntax DellStatus Access Read-only Keyboard Port Security State Name keyboardPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.6 Description Defines the security settings of the keyboard port. Syntax DellPortSecurityState Access Read-only Keyboard Port Connector Type Name keyboardPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.
Keyboard Port BIOS Connector Type Name keyboardPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.9 Description Defines the BIOS connector type of the keyboard port. Syntax DellGenericPortConnectorType Access Read-only Processor Port Table Name processorPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.30 Description Defines the Processor Port Table.
Processor Port Index Name processorPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.2 Description Defines the index of the processor ports in this chassis. Syntax DellObjectRange Access Read-only Processor Port State Capabilities Name processorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.3 Description Defines the capabilities of the processor port.
Processor Port Security State Name processorPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.6 Description Defines the security settings of the processor port. Syntax DellPortSecurityState Access Read-only Processor Port Connector Type Name processorPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.7 Description Defines the connector type of the processor port. Syntax DellProcessorPortConnectorType (See Table 12-3.
Memory Device Port Table Name memoryDevicePortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.40 Description Defines the Memory Device Port Table. Syntax IntegerMemoryDevicePortTableEntry Access Not accessible Memory Device Port Table Entry Name memoryDevicePortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1 Description Defines the Memory Device Port Table entry.
Memory Device Port State Capabilities Name memoryDevicePortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.3 Description Defines the capabilities of the memory device port. Syntax DellStateCapabilities Access Read-only Memory Device Port State Settings Name memoryDevicePortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.4 Description Defines the state and settings of the memory device port.
Memory Device Port Connector Type Name memoryDevicePortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.7 Description Defines the connector type of the memory device port. Syntax DellMemoryDevicePortConnectorType (See Table 12-4.) Access Read-only Memory Device Port Name Name memoryDevicePortName Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.8 Description Defines the name of the memory device port.
Memory Device Port Physical Memory Card Index Reference Name memoryDevicePortPhysicalMemoryCardIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.11 Description Defines the index (one-based) of the Physical Memory Card Table entry for the physical memory card with the same chassis index that this memory device port is associated with (if any). Syntax DellUnsigned32BitRange Access Read-only Monitor Port Table Name monitorPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.
Monitor Port Index Name monitorPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.2 Description Defines the index of the monitor ports in this chassis. Syntax DellObjectRange Access Read-only Monitor Port State Capabilities Name monitorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.3 Description Defines the capabilities of the monitor port. Syntax DellStateCapabilities Access Read-only Monitor Port State Settings Name monitorPortStateSettings Object ID 1.3.6.1.4.
Monitor Port Security State Name monitorPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.6 Description Defines the security settings of the monitor port. Syntax DellPortSecurityState Access Read-only Monitor Port Connector Type Name monitorPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.7 Description Defines the connector type of the monitor port. Syntax DellMonitorPortConnectorTypes (See Table 12-5.
Small Computer System Interface (SCSI) Port Table Name sCSIPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.60 Description Defines the SCSI Port Table. Syntax IntegerSCSIPortTableEntry Access Not accessible SCSI Port Table Entry Name sCSIPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1 Description Defines the SCSI Port Table entry.
SCSI Port State Capabilities Name sCSIPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.3 Description Defines the capabilities of the SCSI port. Syntax DellStateCapabilities Access Read-only SCSI Port State Settings Name DellStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.4 Description Defines the state and settings of the SCSI port. Syntax DellStatus Access Read-write SCSI Port Status Name sCSIPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.
SCSI Port Connector Type Name sCSIPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.7 Description Defines the connector type of the SCSI port. Syntax DellSCSIPortConnectorType (See Table 12-6.) Access Read-only SCSI Port Name Name sCSIPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.8 Description Defines the name of the SCSI port. Syntax DellString Access Read-only SCSI Port BIOS Connector Type Name sCSIPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.
Parallel Port Table Entry Name parallelPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1 Description Defines the Parallel Port Table entry. Syntax ParallelPortTableEntry Access Not accessible Index parallelPortchassisIndex, parallelPortIndex Parallel Port Chassis Index Name parallelPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.1 Description Defines the index (one-based) of this chassis.
Parallel Port State Settings Name parallelPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.4 Description Defines the state and settings of the parallel port. Syntax DellStateSettings Access Read-write Parallel Port Status Name parallelPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.5 Description Defines the status of the parallel port. Syntax DellStatus Access Read-only Parallel Port Security State Name DellPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.
Parallel Port Name Name parallelPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.8 Description Defines the name of the parallel port. Syntax DellString Access Read-only Parallel Port Connector Pin Out Name parallelPortConnectorPinOut Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.9 Description Defines the pinout of the parallel port. Syntax DellParallelPortConnectorPinout Access Read-only Parallel Port Capabilities Unique Name parallelPortCapabilitiesUnique Object ID 1.3.6.1.4.1.674.
Parallel Port IRQ Level Name parallelPortIRQLevel Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.12 Description Defines the Interrupt Request Level (IRQ) of the parallel port. Syntax DellUnsigned8BitRange Access Read-only Parallel Port DMA Support Name parallelPortDMASupport Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.13 Description Defines if direct memory access (DMA) is supported by the parallel port.
Serial Port Chassis Index Name serialPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Serial Port Index Name serialPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.2 Description Defines the index of the serial ports in this chassis. Syntax DellObjectRange Access Read-only Serial Port State Capabilities Name serialPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.
Serial Port Status Name serialPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.5 Description Defines the status of the serial port. Syntax DellStatus Access Read-only Serial Port Security State Name serialPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.6 Description Defines the security settings of the serial port. Syntax DellPortSecurityState Access Read-only Serial Port Connector Type Name serialPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.
Serial Port Maximum Speed Name serialPortMaximumSpeed Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.9 Description Defines the maximum speed the serial interface can support in bits per second (bps). Syntax DellUnsigned32BitRange Access Read-only Serial Port Capabilities Unique Name serialPortCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.10 Description Defines additional capabilities of the serial port.
Universal Serial Bus (USB) Port Table Name uSBPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.90 Description Defines the USB Port Table. Syntax IntegerUSBPortTableEntry Access Not accessible USB Port Table Entry Name uSBPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1 Description Defines the USB Port Table entry. Syntax USBPortTableEntry Access Not accessible Index pointingPortchassisIndex, pointingPortIndex USB Port Chassis Index Name uSBPortchassisIndex Object ID 1.3.6.
USB Port State Capabilities Name uSBPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.3 Description Defines the capabilities of the USB port. Syntax DellStateCapabilities Access Read-only USB Port State Settings Name uSBPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.4 Description Defines the state and settings of the USB port. Syntax DellStateSettings Access Read-write USB Port Status Name uSBPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.
USB Port Connector Type Name uSBPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.7 Description Defines the connector type of the USB port. Syntax DellUSBPortConnectorType Access Read-only USB Port Name Name uSBPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.8 Description Defines the name of the USB port. Syntax DellString Access Read-only USB Port BIOS Connector Type 208 Name uSBPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.
Port Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 12-1. Pointing Port Connector Type Variable Name: DellPointingPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The pointing port connector type is not one of the following: connectorPortTypeIsUnknown(2) The pointing port connector type is unknown.
Table 12-2. Keyboard Port Connector Types Variable Name: DellKeyboardPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The keyboard port connector type is not one of the following: connectorPortTypeIsUnknown(2) The keyboard port connector type is unknown. connectorPortTypeIsMiniDIN(3) The keyboard port connector type is a mini DIN. connectorPortTypeIsMicroDIN(4) The keyboard port connector type is a MicroDIN.
Table 12-4. Memory Device Port Connector Types Variable Name: DellMemoryDevicePortConnectorType Data Type: Integer Possible Data Value Meaning of Data Value connectorPortTypeIsOther(1) The memory device port connector type is not one of the following: connectorPortTypeIsUnknown(2) The memory device port connector type is unknown. connectorPortTypeIsSIMM(3) The memory device port connector type is a single in-line memory module (SIMM).
Table 12-5. Monitor Port Connector Types Variable Name: DellMonitorPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The monitor port connector type is not one of the following: connectorPortTypeIsUnknown(2) The monitor port connector type is unknown. connectorPortTypeIsDB15PinMale(3) The monitor port connector type is a male DB-15. connectorPortTypeIsDB15PinFemale(4) The monitor port connector type is a female DB-15. Table 12-6.
Device Group The Device Group provides information about different types of pointing, keyboard, processor, cache, memory, and peripheral component interconnect (PCI) devices. Variables in this group cover information about type, settings, configuration, manufacturer, address or location, and if applicable, the speed of the device.
Pointing Device Table Entry Name pointingDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1 Description Defines the Pointing Device Table entry. Syntax PointingDeviceTableEntry Access Not accessible Index pointingDevicechassisIndex, pointingDeviceIndex Pointing Device Chassis Index Name pointingDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.1 Description Defines the index (one-based) of this chassis.
Pointing Device State Settings Name pointingDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.4 Description Defines the state of the pointing device. Syntax DellStateSettings Access Read-write Pointing Device Status Name pointingDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.5 Description Defines the status of the pointing device. Syntax DellStatus Access Read-only Pointing Port Index Reference Name pointingPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.
Pointing Device Number of Buttons Name pointingDeviceNumberofButtons Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.8 Description Defines the number of buttons on the pointing device. Syntax DellUnsigned8BitRange Access Read-only Keyboard Device Table Name keyboardDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.20 Description Defines the Keyboard Device Table. This table references the Keyboard Port Index (See Section 12).
Keyboard Device Index Name keyboardDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.2 Description Defines the index of the keyboard device for this chassis. Syntax DellObjectRange Access Read-only Keyboard Device State Capabilities Name keyboardDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.3 Description Defines the capabilities of the keyboard device.
Keyboard Port Index Reference Name keyboardPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.6 Description Defines the index to the associated the keyboard port in this chassis. Syntax DellStatus Access Read-only Keyboard Device Type Name Name keyboardDeviceTypeName Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.7 Description Defines the name of the keyboard type. Syntax DellString Access Read-only Keyboard Device Layout Name Name keyboardDeviceLayoutName Object ID 1.3.6.1.
Processor Device Table Entry Name processorDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1 Description Defines the Processor Device Table entry. Syntax ProcessorDeviceTableEntry Access Not accessible Index processorDevicechassisIndex, processorDeviceIndex Processor Device Chassis Index Name processorDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.1 Description Defines the index (one-based) of this chassis.
Processor Device State Settings Name processorDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.4 Description Defines the state of the processor device. Syntax DellStateSettings Access Read-write Processor Device Status Name processorDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.5 Description Defines the status of the processor device. Syntax DellStatus Access Read-only Processor Port Index Reference Name processorPortIndexReference Object ID 1.3.6.1.4.1.674.
Processor Device Manufacturer Name Name processorDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.8 Description Defines the name of manufacturer of the processor device. Syntax DellString Access Read-only Processor Device Status State Name processorDeviceStatusState Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.9 Description Defines the status state of the processor device. Syntax DellProcessorDeviceStatusState (See Table 13-2.
Processor Device Current Speed Name processorDeviceCurrentSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.12 Description Defines the current speed of the processor device in MHz. A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Processor Device External Clock Speed Name processorDeviceExternalClockSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.
Processor Device Version Name Name processorDeviceVersionName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.16 Description Defines the version name of the processor device. Syntax DellString Access Read-only Processor Device Core Count Name processorDeviceCoreCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.17 Description Defines the number of processor cores detected for the processor device.
Processor Device Characteristics Name processorDeviceCharacteristics Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.20 Description This attribute defines characteristics of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one). NOTE: Bits 2-15 need to be examined in the context of bit 1. If bit 1 is set, the processor characteristics are unknown and bits 2-15 cannot be used to determine if the functions associated with the bits are supported.
Processor Device Extended Settings Name processorDeviceExtendedSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.22 Description This attribute defines extended settings of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
Processor Device Stepping Name Name processorDeviceSteppingName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.25 Description Defines the stepping of the processor device. Syntax DellString Access Read-only Processor Device Status Table Name processorDeviceStatusTable Object ID 1.3.6.1.4.1.674.10892.1.1100.32 Description Defines the Processor Device Status Table.
Processor Device Status Index Name processorDeviceStatusIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.2 Description Defines the index (one-based) of the processor device status probe. Syntax DellObjectRange Access Read-only Processor Device Status State Capabilities Name processorDeviceStatusStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.3 Description Defines the state capabilities of the processor device status probe.
Processor Device Status Reading Name processorDeviceStatusReading Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.6 Description Defines the reading of the processor device status probe. Syntax DellProcessorDeviceStatusReading Access Read-only Processor Device Status Location Name Name processorDeviceStatusLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.7 Description Defines the location name of the processor device status probe.
Cache Device Table Entry Name cacheDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1 Description Defines the Cache Device Table entry. Syntax CacheDeviceTableEntry Access Not accessible Index cacheDevicechassisIndex, cacheDeviceIndex Cache Device Chassis Index Name cacheDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.1 Description Defines the index (one-based) of this chassis.
Cache Device State Settings Name cacheDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.4 Description Defines the state of the cache device. Syntax DellStateSettings Access Read-write Cache Device Status Name cacheDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.5 Description Defines the status of the cache device. Syntax DellStatus Access Read-only Cache Device Processor Device Index Reference Name cacheDeviceprocessorDeviceIndexReference Object ID 1.3.6.1.4.1.
Cache Device Location Name cacheDeviceLocation Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.8 Description Defines the location of the cache device. Syntax DellCacheDeviceLocation (See Table 13-13.) Access Read-only Cache Device Status State Name cacheDeviceStatusState Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.9 Description Defines the status state of the cache device. Syntax DellCacheDeviceStatusState (See Table 13-10.
Cache Device Maximum Size Name cacheDeviceMaximumSize Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.12 Description Defines the maximum size of the cache device in kilobytes (KB). A zero (0) indicates that the size is unknown. Syntax DellUnsigned32BitRange Access Read-only Cache Device Current Size Name cacheDeviceCurrentSize Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.13 Description Defines the current size of the cache device in KB. A zero (0) indicates that the size is unknown.
Cache Device Is Socketed Name cacheDeviceIsSocketed Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.16 Description Defines if the cache device is socketed. Syntax DellBoolean Access Read-only Cache Device Error Checking and Correction (ECC) Type Name cacheDeviceECCType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.17 Description Defines the type of error correction in use by the cache device. Syntax DellCacheDeviceECCType (See Table 13-11.
Cache Device Current Type Name cacheDeviceCurrentType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.20 Description Defines the current type of SRAM for the cache device. Syntax DellCacheDeviceSRAMType (See Table 13-14.) Access Read-only Memory Device Table Name memoryDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.50 Description Defines the Memory Device Table.
Memory Device Index Name memoryDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.2 Description Defines the index of the memory device in this chassis. Syntax DellObjectRange Access Read-only Memory Device State Capabilities Name memoryDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.3 Description Defines the capabilities of the memory device. Syntax DellStateCapabilities Access Read-only Memory Device State Settings Name memoryDeviceStateSettings Object ID 1.
Memory Device Memory Port Index Reference Name memoryDeviceMemoryPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.6 Description Defines the index of the memory port of which this memory device is part. Syntax DellObjectRange Access Read-only Memory Device Type Name memoryDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.7 Description Defines the type of the memory device. Syntax DellMemoryDeviceType (See Table 13-16.
Memory Device Bank Location Name Name memoryDeviceBankLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.10 Description Defines the bank location name of the memory device. Syntax DellString Access Read-only Memory Device Type Details Name memoryDeviceTypeDetails Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.11 Description Defines the detailed type of the memory device. Syntax DellMemoryDeviceTypeDetails (See Table 13-17.
Memory Device Size Name memoryDeviceSize Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.14 Description Defines the size in KB of the memory device. Syntax DellUnsigned32BitRange Access Read-only Memory Device Speed Name memoryDeviceSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.15 Description Defines the speed in nanoseconds of the memory device. A zero (0) indicates that the speed is unknown.
Memory Device Correctable Memory Event Count NOTE: Memory Device Failure Modes has now replaced this attribute. Memory Device Correctable Memory Event Count should no longer be used. If you use the Memory Device Correctable Memory Event Count attribute, the value returned is always zero, and using the attribute will have no effect. Name memoryDeviceSingleBitErrorCount Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.
Memory Device Manufacturer Name Name memoryDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.21 Description Defines the manufacturer of the memory device. Syntax DellString Access Read-only Memory Device Part Number Name Name memoryDevicePartNumberName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.22 Description Defines the manufacturer's part number for the memory device.
Memory Device Speed Name Name memoryDeviceSpeedName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.25 Description This attribute defines the speed of the memory device in string format with units specified in string. Syntax DellString Access Read-only Memory Device Mapped Address Table Name memoryDeviceMappedAddressTable Object ID 1.3.6.1.4.1.674.10892.1.1100.60 Description Defines the Memory Device Mapped Address Table.
Memory Device Mapped Address Index Name memoryDeviceMappedAddressIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.2 Description Defines the index (one-based) of the memory device mapped address in this chassis. Syntax DellObjectRange Access Read-only Memory Device Mapped Address State Capabilities Name memoryDeviceMappedAddressStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.3 Description Defines the capabilities of the memory device mapped address.
Memory Device Index Reference Name memoryDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.6 Description Defines the index of the memory device(s) associated with this memory device mapped address. Syntax DellObjectRange Access Read-only Memory Device Mapped Address Row Position Name memoryDeviceMappedAddressRowPosition Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.7 Description Defines the position of the referenced memory in a row of the memory device mapped address.
Memory Device Mapped Address Starting Address Name memoryDeviceMappedAddressStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.10 Description Defines the physical starting address in KB of the memory device mapped address. Syntax DellUnsigned64BitRange Access Read-only Memory Device Mapped Address Ending Address Name memoryDeviceMappedAddressEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.
Generic Device Chassis Index Name genericDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Generic Device Index Name genericDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.2 Description Defines the index of the generic device in this chassis. Syntax DellObjectRange Access Read-only Generic Device State Capabilities Name genericDeviceStateCapabilities Object ID 1.3.
Generic Device Status Name genericDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.5 Description Defines the status of the generic device. Syntax DellStatus Access Read-only Generic Device System Slot Index Reference Name genericDeviceSystemSlotIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.6 Description Defines the index of the system slot into which this generic device is plugged.
PCI Device Table Name pCIDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.80 Description Defines the PCI Device Detail Table. Syntax SEQUENCE OF PCIDeviceTableEntry Access Not accessible PCI Device Table Entry Name pCIDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1 Description Defines the PCI Device Table entry. Syntax Not accessible Access PCIDeviceTableEntry Index pCIDevicechassisIndex, pCIDeviceIndex PCI Device Chassis Index Name pCIDevicechassisIndex Object ID 1.
PCI Device State Capabilities Name pCIDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.3 Description Defines the capabilities of the PCI device. Syntax DellStateCapabilities Access Read-only PCI Device State Settings Name pCIDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.4 Description Defines the state of the PCI device. Syntax DellStateSettings Access Read-write PCI Device Status Name pCIDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.
PCI Device Data Bus Width Name pCIDeviceDataBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.7 Description Defines the bus width of the PCI device in this chassis. Syntax DellUnsigned32BitRange Access Read-only PCI Device Manufacturer Name Name pCIDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.8 Description Defines the name of the PCI device manufacturer. Syntax DellString Access Read-only PCI Device Description Name Name pCIDeviceDescriptionName Object ID 1.3.
PCI Device Adapter Fault Name pCIDeviceAdapterFault Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.11 Description Defines whether the PCI device in this chassis has detected a fault. Syntax DellBoolean Access Read-only PCI Device Configuration Space Table Name pCIDeviceConfigurationSpaceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.82 Description Defines the PCI Device Configuration Table.
PCI Device Configuration Space Index Name pCIDeviceConfigurationSpaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.2 Description Defines the index (one-based) of the PCI device configuration in this chassis. Syntax DellObjectRange Access Read-only PCI Device Configuration Space State Capabilities Name pCIDeviceConfigurationSpaceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.3 Description Defines the capabilities of the PCI device configuration.
PCI Device Index Reference Name pCIDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.6 Description Defines the index number of PCI device that this configuration applies to. Syntax DellObjectRange Access Read-only PCI Device Configuration Space Bus Number Name pCIDeviceConfigurationSpaceBusNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.7 Description Defines the bus number of the PCI device configuration in this chassis.
PCI Device Configuration Space Header Name pCIDeviceConfigurationSpaceHeader Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.10 Description Defines the common configuration space header of the PCI device. Syntax OCTET STRING (SIZE(0..1025)) Access Read-only Network Device Table Name networkDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.90 Description Defines the Network Device Table.
Network Device Index Name networkDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.2 Description Defines the index (one-based) of the network device. Syntax DellObjectRange Access Read-only Network Device Status Name networkDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.3 Description Defines the status of the network device. Syntax DellStatus Access Read-only Network Device Connection Status Name networkDeviceConnectionStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.90.
Network Device Product Name Name networkDeviceProductName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.6 Description Defines the product name of the network device. Syntax DellString Access Read-only Network Device Vendor Name Name networkDeviceVendorName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.7 Description Defines the name of the vendor of the network device. Syntax DellString Access Read-only Network Device Service Name Name networkDeviceServiceName Object ID 1.3.6.1.4.1.674.
Network Device Driver Version Name Name networkDeviceDriverVersionName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.10 Description Defines the version of the driver for the network device. Syntax DellString Access Read-only Network Device IP Address Name networkDeviceIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.11 Description Defines the IP address of the network device. Syntax IpAddress Access Read-only Network Device IP Subnet Mask Name networkDeviceIPSubnetMask Object ID 1.
Network Device DHCP Server IP Address Name networkDeviceDHCPServerIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.14 Description Defines the IP address of the DHCP server that was used to obtain the IP address of the network device if DHCP was used to configure the network device. Syntax IpAddress Access Read-only Network Device Current MAC Address Name networkDeviceCurrentMACAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
Network Device PCI Device Number Name networkDevicePCIDeviceNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.18 Description Defines the PCI device number of the network device. Syntax DellUnsigned8BitRange Access Read-only Network Device PCI Function Number Name networkDevicePCIFunctionNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.19 Description Defines the PCI function number of the network device.
Network Device Teaming Flags Name networkDeviceTeamingFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.22 Description Defines the teaming features of the network device. Syntax DellNetworkDeviceTeamingFlags (see Table 13-21) Access Read-only Network Device TOE Capability Flags Name networkDeviceTOECapabilityFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.23 Description Defines the TCP/IP Offload Engine (TOE) capability flags of the network device.
Network Device RDMA Enabled Name networkDeviceRDMAEnabled Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.26 Description Defines if RDMA is enabled for the network device. Syntax DellBoolean Access Read-only Network Device iSCSI Capability Flags Name networkDeviceiSCSICapabilityFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.27 Description Defines the Internet Small Computer System Interface (iSCSI) capability flags of the network device.
Device Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 13-1. Pointing Device Type Variable Name: DellPointingDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1) Device type is not one of the following: deviceTypeIsUnknown(2) Device type is unknown. deviceTypeIsAMouse(3) Device type is a mouse. deviceTypeIsATrackBall(4) Device type is a track ball.
Table 13-3. Processor Device Status Reading Variable Name: DellProcessorDeviceStatusReading Data Type: Integer NOTE: These values are bit masks, so combination values are possible.
Table 13-5. Processor Upgrade Information Variable Name: DellProcessorUpgradeInformation Data Type: Integer Possible Data Values Meaning of Data Value processorUpgradeIsOther(1) The upgrade device type is not one of the following: processorUpgradeIsUnknown(2) Upgrade device type is unknown. processorUpgradeIsByDaughterBoard(3) Upgrade device is on a daughter board. processorUpgradeIsByZIFSocket(4) Upgrade device is in a zero insertion force (ZIF) socket.
Table 13-6. Processor Device Family Variable Name: DellProcessorDeviceFamily Data Type: Integer 264 Possible Data Values Meaning of Data Value deviceFamilyIsOther(1) The processor family is not one of the following values: deviceFamilyIsUnknown(2) The processor family is unknown. deviceFamilyIs8086(3) The processor family is 8086. deviceFamilyIs80286(4) The processor family is 80286. deviceFamilyIs80386(5) The processor family is 80386. deviceFamilyIs80486(6) The processor family is 80486.
Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsK6-3(28) The processor family is K6-3. deviceFamilyIsAMDAthlon(29) The processor family is AMD Athlon. deviceFamilyIsAMD2900(30) The processor family is AMD2900. deviceFamilyIsK6-2Plus(31) The processor family is K6-2+. deviceFamilyIsPowerPC(32) The processor family is Power PC.
Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsmicroSPARCII(82) The processor family is microSPARC II. deviceFamilyIsmicroSPARCIIep(83) The processor family is microSPARC IIep. deviceFamilyIsUltraSPARC(84) The processor family is UltraSPARC. deviceFamilyIsUltraSPARCII(85) The processor family is UltraSPARC II.
Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsPA-RISC8000(146) The processor family is PA-RISC 8000. deviceFamilyIsPA-RISC7300LC(147) The processor family is PA-RISC 7300LC. deviceFamilyIsPA-RISC7200(148) The processor family is PA-RISC 7200. deviceFamilyIsPA-RISC7100LC(149) The processor family is PA-RISC 7100LC.
Table 13-7. Cache Device Type Variable Name: DellCacheDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1) System cache type is not one of the following: deviceTypeIsUnknown(2) System cache type is unknown. deviceTypeIsInstruction(3) System cache type is instruction. deviceTypeIsData(4) System cache type is data. deviceTypeIsUnified(5) System cache type is both instruction and data. Table 13-8.
Table 13-10. Cache Device Status State Variable Name: DellCacheDeviceStatusState Data Type: Integer Possible Data Values Meaning of Data Value other(1) Device state is not one of the following: unknown(2) Device state is unknown. enabled(3) Device is enabled. userDisabled(4) Device is disabled by the user. biosDisabled(5) Device basic input/output system (BIOS) is disabled. Table 13-11.
Table 13-12. Cache Device Associativity Variable Name: DellCacheDeviceAssociativity Data Type: Integer Possible Data Values Meaning of Data Value deviceAssociativityIsOther(1) Device associativity is not one of the following: deviceAssociativityIsUnknown(2) Device associativity is unknown. deviceAssociativityIsDirectMapped(3) Device is direct mapped. deviceAssociativityIsTwoWaySetAssociative(4) Device is two-way set associative.
Table 13-14. Cache Device Static Random-Access Memory (SRAM) Type Variable Name: DellCacheDeviceSRAMType Data Type: Integer Possible Data Values Meaning of Data Value deviceSRAMTypeIsOther(1) Device SRAM type is not one of the following: deviceSRAMTypeIsUnknown(2) Device SRAM type is unknown. deviceSRAMTypeIsNonBurst(3) Device SRAM type is nonburst. deviceSRAMTypeIsBurst(4) Device SRAM type is burst. deviceSRAMTypeIsPipeBurst(5) Device SRAM type is pipeburst.
Table 13-16. Memory Device Type Variable Name: DellMemoryDeviceType Data Type: Integer 272 Possible Data Values Meaning of Data Value deviceTypeIsOther(1) Device type is not one of the following: deviceTypeIsUnknown(2) Device type is unknown. deviceTypeIsDRAM(3) Device type is DRAM. deviceTypeIsEDRAM(4) Device type is EDRAM. deviceTypeIsVRAM(5) Device type is VRAM. deviceTypeIsSRAM(6) Device type is SRAM. deviceTypeIsRAM(7) Device type is RAM. deviceTypeIsROM(8) Device type is ROM.
Table 13-17. Memory Device Type Details Variable Name: DellMemoryDeviceTypeDetails Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeDeatilIsOther(1) The detailed device type is not one of the following: deviceTypeDetailIsUnknown(2) The detailed device type is unknown. deviceTypeDetailIsFastPaged(3) The detailed device type is fast paged. deviceTypeDetailIsStaticColumn(4) The detailed device type is static column.
Table 13-19. Memory Device Failure Modes Variable Name: DellMemoryDeviceFailureModes Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value (0) Memory device has no faults. eccSingleBitCorrectionWarningRate(1) Memory device has exceeded the Correctable Memory Event warning rate. eccSingleBitCorrectionFailureRate(2) Memory device has exceeded the Correctable Memory Event failure rate.
Table 13-21. Network Device Teaming Flags Variable Name: DellNetworkDeviceTeamingFlags Data Type: Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value undefined(0) Teaming flags are undefined. noTeam(1) Device is not part of any team. teamingEnabled(2) Teaming is enabled. adapterFaultToleranceMode(4) Adapter fault tolerance teaming mode. loadBalancingMode(8) Load balancing teaming mode. Table 13-22.
Table 13-23. Network Device RDMA Capability Flags Variable Name: DellNetworkDeviceRDMACapabilityFlags Data Type: Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) Querying for RDMA capability is not supported. unknown(1) Querying for RDMA capability is supported but query returned an error. available(2) Device has RDMA capability. notAvailable(4) Device does not have RDMA capability.
Slot Group The Slot Group provides information about the types of slots that your system supports. This management information base (MIB) group also provides information about the voltages, capabilities, states, and settings that are possible for these slots. System Slot Group Table The System Slot Group defines objects in the System Slot MIB table. System Slot Table The following object sets up the System Slot Table: Name systemSlotTable Object ID 1.3.6.1.4.1.674.10892.1.1200.
System Slot Chassis Index Name systemSlotchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System Slot Index Name systemSlotIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.2 Description Defines the index (one-based) of the system slot in this chassis.
System Slot Status Name systemSlotStatus Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.5 Description Defines the status of the system slot. Syntax DellStatus Access Read-only System Slot Current Usage Name systemSlotCurrentUsage Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.6 Description Defines the current usage of the system slot. Syntax DellStatus Access Read-only System Slot Type Name systemSlotType Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.
System Slot Length Name systemSlotLength Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.9 Description Defines the length of the system slot. Syntax DellSystemSlotLength (See Table 14-5.) Access Read-only System Slot Slot ID Name systemSlotSlotID Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.10 Description Defines the slot identification number of the system slot. A zero (0) indicates that the slot is embedded on the motherboard.
System Slot Hot-Plug Slot Speed Name systemSlotHotPlugSlotSpeed Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.13 Description Defines the slot speed in megahertz of the hot-plug system slot. A zero (0) indicates that the slot speed is unknown. Syntax DellUnsigned32BitRange Access Read-only System Slot Hot-Plug Adapter Speed Name systemSlotHotPlugAdapterSpeed Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.14 Description Defines the adapter speed in megahertz of the hot-plug system slot.
Table 14-1. System Slot State Capabilities (continued) Variable Name: DellSystemSlotStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value systemSlotHotPlugCanSignalPowerButtonPressed(64) The system slot power button can be pressed to signal a toggle of the power state. 282 canSupportAllHotPlugCapabilities(126) The system slot can support all hot-plug capabilities. systemSlotHotPlugIsUnknown(1) The system slot’s capabilities are unknown.
Table 14-2. System Slot State Settings Variable Name: DellSystemSlotStateSettings Data Type: Integer Possible Data Values Meaning of Data Value systemSlotHotPlugIsUnknown(1) The system slot’s capabilities are unknown. systemSlotHotPlugIsHotPluggable(2) The system slot supports hot-plug. systemSlotHotPlugIsPoweredOn(4) The system slot power (and corresponding LED) can be powered on. systemSlotHotPlugIsAtAttention(8) The system slot attention state (and corresponding LED) can be set.
Table 14-2. System Slot State Settings (continued) Variable Name: DellSystemSlotStateSettings Data Type: Integer Possible Data Values Meaning of Data Value supportsPMEand3P3Vand5VhasAdapterOn(16804) The system slot supports power management event (PME), supplies 3.3 V, and supplies 5 V. The adapter is on. supportsPMEand3P3Vand5VhasAdapterOnandisHotPlug The system slot supports PME, supplies 3.3 V, gable(16806) and supplies 5 V. The adapter is on and the system slot is hot pluggable.
Table 14-3. System Slot Type (continued) Variable Name: DellSystemSlotType Data Type: Integer Possible Data Values Meaning of Data Value systemSlotIsProprietary(9) The system slot is proprietary. systemSlotIsProcessorCard(10) The system slot is a processor card. systemSlotIsProprietaryMemory(11) The system slot is proprietary memory. systemSlotIsIORiserCard(12) The system slot is an I/O riser card. systemSlotIsNuBUS(13) The system slot is a NuBus.
Table 14-4. System Slot Usage Variable Name: DellSystemSlotUsage Data Type: Integer Possible Data Values Meaning of Data Value systemSlotUsageIsOther(1) The system slot usage is not one of following: systemSlotUsageIsUnknown(2) The system slot usage is unknown. systemSlotUsageIsAvailable(3) The system slot is available. systemSlotUsageIsInUse(4) The system slot is in use. Table 14-5.
Table 14-7. Hot-Plug Bus Width Variable Name: DellSystemSlotHotPlugBusWidth Data Type: Integer Possible Data Values Meaning of Data Value busWidthIsOther(1) The system slot bus width is not one of following: busWidthIsUnknown(2) The system slot bus width is unknown. busWidthIs8bits(3) The system slot bus width is 8 bits. busWidthIs16bits(4) The system slot bus width is 16 bits. busWidthIs32bits(5) The system slot bus width is 32 bits. busWidthIs64bits(6) The system slot bus width is 64 bits.
Slot Group
Memory Group The Memory Group provides information about the physical memory in your system. Variables in this group include error correction type, location, and different types of memory use, such as cache, flash, system, video, and nonvolatile memory.
Physical Memory Array Table Entry Name physicalMemoryArrayTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1 Description Defines the Physical Memory Array Table entry. Syntax PhysicalMemoryArrayTableEntry Access Not accessible Index physicalMemoryArraychassisIndex, physicalMemoryArrayIndex Physical Memory Array Chassis Index Name physicalMemoryArraychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.1 Description Defines the index (one-based) of this chassis.
Physical Memory Array State Settings Name physicalMemoryArrayStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.4 Description Defines the state of the physical memory array. Syntax DellStateSettings Access read-write Physical Memory Array Status Name physicalMemoryArrayStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.5 Description Defines the status of the physical memory array.
Physical Memory Array Location Name physicalMemoryArrayLocation Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.8 Description Defines the location of the physical memory array. Syntax DellPhysicalMemoryArrayLocation (See Table 15-1.) Access Read-only Physical Memory Array Maximum Size Name physicalMemoryArrayMaximumSize Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.9 Description Defines the size in KB of the physical memory array.
Physical Memory Array ECC Error Nonrecoverable Threshold Name physicalMemoryArrayECCErrorNonRecoverbeThreshold Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.12 Description Defines the value of the physical memory array Error Checking and Correction (ECC) error nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Physical Memory Array ECC Error Critical Threshold Name physicalMemoryArrayECCErrorCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.
Physical Memory Array Mapped Table The physical memory array is divided into memory array mapped addresses. The following object sets up the Physical Memory Array Mapped Table: Name physicalMemoryArrayMappedTable Object ID 1.3.6.1.4.1.674.10892.1.1300.20 Description Defines the Physical Memory Array Mapped Table. Syntax PhysicalMemoryArrayMappedTableEntry Access Not accessible Physical Memory Array Mapped Table Entry Name PhysicalMemoryArrayMappedTableEntry Object ID 1.3.6.1.4.1.674.10892.1.
Physical Memory Array Mapped State Capabilities Name physicalMemoryArrayMappedStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.3 Description Defines the capabilities of the memory array mapped address. Syntax DellStateCapabilities Access Read-only Physical Memory Array Mapped State Settings Name physicalMemoryArrayMappedStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.4 Description Defines the state of the memory array mapped address.
Physical Memory Array Mapped Starting Address Name physicalMemoryArrayMappedStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.7 Description Defines the physical starting address in KB of the memory array mapped address. Syntax DellUnsigned64BitRange Access Read-only Physical Memory Array Mapped Ending Address Name physicalMemoryArrayMappedEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.
Physical Memory Configuration Table This table defines how the physical memory of a system chassis is set up, for example, which redundant memory types are supported and whether redundant memory is active. The following object sets up the Physical Memory Configuration Table: Name physicalMemoryConfigTable Object ID 1.3.6.1.4.1.674.10892.1.1300.30 Description Defines the Physical Memory Configuration Table.
Physical Memory Configuration State Capabilities Name physicalMemoryConfigStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.3 Description Defines the state capabilities of the physical memory configuration. Syntax DellPhysicalMemoryConfigStateCapabilities Access Read-only Physical Memory Configuration State Settings Name physicalMemoryConfigStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.4 Description Defines the state settings of the physical memory configuration.
Physical Memory Configuration Redundant Settings Name physicalMemoryConfigRedundantSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.7 Description Defines the redundant settings of the physical memory. Syntax DellPhysicalMemoryConfigRedundantSettings Access Read-write Physical Memory Logging Table This table defines the conditions for logging system memory events. The following object sets up the Physical Memory Logging Table: Name physicalMemoryLoggingTable Object ID 1.3.6.1.4.1.674.10892.
Physical Memory Logging Index Name physicalMemoryLoggingIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.2 Description Defines the index (one-based) of the physical memory logging. Syntax DellObjectRange Access Read-only Physical Memory Logging Capabilities Name physicalMemoryLoggingCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.3 Description Defines the capabilities of the physical memory logging.
Redundant Memory Unit Table This table reports the status of redundant memory within a particular system chassis. The following object sets up the Redundant Memory Unit Table: Name redundantMemoryUnitTable Object ID 1.3.6.1.4.1.674.10892.1.1300.50 Description Defines the Redundant Memory Unit Table. Syntax SEQUENCE OF RedundantMemoryUnitTableEntry Access Not accessible Redundant Memory Unit Table Entry Name redundantMemoryUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.50.
Redundant Memory Unit State Capabilities Name redundantMemoryUnitStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.3 Description Defines the state capabilities of the redundant memory unit. Syntax DellStateCapabilities Access Read-only Redundant Memory Unit State Settings Name redundantMemoryUnitStatesettings Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.4 Description Defines the state settings of the redundant memory unit.
Redundant Memory Unit Status Name redundantMemoryUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.7 Description Defines the status of the redundant memory unit. Syntax DellStatus Access Read-only Physical Memory Card Table This table defines the name of the memory card, the total number of device slots present on the memory card, and the number of memory device slots in use on the memory card.
Physical Memory Card Index Name physicalMemoryCardIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.2 Description Defines the index (one-based) of the Physical Memory Card. Syntax DellObjectRange Access Read-only Physical Memory Card State Capabilities Name physicalMemoryCardStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.3 Description Defines the state capabilities of the Physical Memory Card.
Physical Memory Card Name Name physicalMemoryCardName Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.6 Description Defines the name of the Physical Memory Card. Syntax DellString Access Read-only Physical Memory Card Total Number Sockets Name physicalMemoryCardTotalNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.7 Description Defines the total number of memory sockets available on the Physical Memory Card. 2,147,483,647 indicates an unknown number of sockets.
Memory Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 15-1. Physical Memory Array Location Variable Name: DellPhysicalMemoryArrayLocation Data Type: Integer Possible Data Values Meaning of Data Value memoryArrayLocationIsOther(1) The memory array location is not one of the following: memoryArrayUseIsUnknown(2) The memory array use is unknown. memoryArrayUseIsSystemMemory(3) The memory array is system memory.
Table 15-2. Physical Memory Array ECC Type Definitions Variable Name: DellPhysicalMemoryArrayECCType Data Type: Integer Possible Data Values Meaning of Data Value memoryArrayECCTypeIsOther(1) There is not one of the following: memoryArrayECCTypeIsUnknown(2) The memory array ECC type is unknown. memoryArrayECCTypeIsNone(3) The memory array ECC type is none. memoryArrayECCTypeIsParity(4) The memory array ECC type is parity.
Table 15-4. Physical Memory Configuration State Settings Variable Name: DellPhysicalMemoryConfigStateSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no state settings. unknown(1) State settings are unknown. enabled(2) Object is disabled (offline) 0, or enabled (online) 1. notReady(4) Object "not ready." redundantMemoryIsActive(8) Redundant memory is active (in use) enabledAndRedundantMemoryIsActive(10) Redundant memory is enabled and in use.
Table 15-6. Physical Memory Configuration Redundant Settings Variable Name: DellPhysicalMemoryConfigRedundantSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no redundant memory settings enabled. unknown(1) Redundant settings are unknown. The following redundant settings are mutually exclusive: spareEnabled(2) Spare redundant memory feature is enabled. mirrorEnabled(4) Mirror redundant memory feature is enabled.
Memory Group
BIOS Setup Control Group Basic Input/Output System (BIOS) Setup Control Group variables provide information about the functions that the BIOS performs in your system. This management information base (MIB) group includes variables for the boot sequence, speakers, diskettes, ports, network interface controllers (NICs), and the Wakeup on local area network (LAN) feature. BIOS Group Tables The objects in this group define the BIOS control of devices and controller cards that are typically present in a system.
BIOS Setup Control Table Entry Name biosSetUpControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1 Description Defines the BIOS Control Device Table entry. Syntax BiosSetUpControlTableEntry Access Not accessible Index biosSetUpControlchassisIndex BIOS Setup Control Chassis Index Name biosSetUpControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.1 Description Defines the index (one-based) of this chassis.
BIOS Setup Control Pointing Device Control Status Name bSUCpointingDeviceControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.4 Description Defines the status of the pointing device. Syntax DellStatus Access Read-only BIOS Setup Control Pointing Device Control Name Name bSUCpointingDeviceControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.5 Description Defines the setup BIOS name of the pointing device.
BIOS Setup Control Numeric Lock Control Status Name bSUCnumLockControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.8 Description Defines the status of the numeric lock. Syntax DellStatus Access Read-only BIOS Setup Control Numeric Lock Control Name Name bSUCnumLockControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.9 Description Defines the setup BIOS name of the numeric lock.
BIOS Setup Control Processor Serial Number Control Status Name bSUCprocessorSerialNumberControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.12 Description Defines the status of the processor serial number. Syntax DellStatus Access Read-only BIOS Setup Control Processor Serial Number Control Name Name bSUCprocessorSerialNumberControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.13 Description Defines the setup BIOS name of the processor serial number.
BIOS Setup Control Speaker Control Status Name bSUCspeakerControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.16 Description Defines the status of speaker control. Syntax DellStatus Access Read-only BIOS Setup Control Speaker Control Name Name bSUCspeakerControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.17 Description Defines the setup BIOS name of the speaker control.
BIOS Setup Control NIF Wakeup on LAN Control Status Name bSUCnIFwakeonLanControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.20 Description Defines the status of the NIF Wakeup on LAN. Syntax DellStatus Access Read-only BIOS Setup Control NIF Wakeup on LAN Control Name Name bSUCnIFwakeonLanControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.21 Description Defines the setup BIOS name of the NIF Wakeup on LAN.
BIOS Setup Control Boot Sequence Control Status Name bSUCbootSequenceControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.24 Description Defines the status of the boot sequence. Syntax DellStatus Access Read-only BIOS Setup Control Boot Sequence Control Name Name bSUCbootSequenceControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.25 Description Defines the control name of the boot sequence.
BIOS Setup Control Administrator Password Control Status Name bSUCadministratorPasswordControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.28 Description Defines the status for administrator password control. Syntax DellStatus Access Read-only BIOS Setup Control Administrator Password Verify Name Name bSUCadministratorPasswordVerifyName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.29 Description Defines the setup BIOS name for the current administrator password.
BIOS Control Setup User Password Control Settings Unique Name bSUCuserPasswordControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.32 Description Defines the control settings for user password control. Syntax DellBIOSPasswordControlSettingsUnique (See Table 16-9.) Access Read-write BIOS Control Setup User Password Control Status Name bSUCuserPasswordControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.33 Description Defines the status of the user password control.
SCSI Control Table Name sCSIControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.20 Description Defines the Small Computer System Interface (SCSI) Control Table. Syntax SCSIControlTableEntry Access Not accessible SCSI Control Table Entry Name sCSIControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1 Description Defines the SCSI Control Table entry.
SCSI Control Capabilities Name sCSIControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.3 Description Defines the capabilities of the SCSI controller. Syntax DellStateCapabilities Access Read-only SCSI Control Settings Name sCSIControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.4 Description Defines the state of the SCSI controller. Syntax DellStateSettings Access Read-only SCSI Control Status Name sCSIControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.
Parallel Port Control Table Name parallelPortControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.30 Description Defines the Parallel Port Control Table. Syntax ParallelPortControlTableEntry Access Not accessible Parallel Port Control Table Entry Name parallelPortControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1 Description Defines the Parallel Port Control Table entry.
Parallel Port Control Capabilities Unique Name parallelPortControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.3 Description Defines the capabilities of the parallel port. Syntax DellParallelPortControlCapabilitiesUnique (See Table 16-10.) Access Read-only Parallel Port Control Settings Unique Name parallelPortControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.4 Description Defines the state of the parallel port.
Parallel Port Control Mode Capabilities Unique Name parallelPortControlModeCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.7 Description Defines the mode capabilities of the parallel port. Syntax DellParallelPortControlModeCapabilitiesUnique (See Table 16-12.) Access Read-only Parallel Port Control Mode Settings Unique Name parallelPortControlModeSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.8 Description Defines the mode settings of the parallel port.
Serial Port Control Chassis Index Name serialPortControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.1 Description Defines index (one-based) of this chassis. Syntax DellObjectRange Access read-only Serial Port Control Index Name serialPortControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.2 Description Defines the index (one-based) of the serial port in this chassis.
Serial Port Control Status Name serialPortControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.5 Description Defines the status of the serial port. Syntax DellStatus Access Read-only Serial Port Control Name Name serialPortControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.6 Description Defines the setup BIOS name of the serial port. Syntax DellString Access Read-only USB Control Table These objects enable you to track the attributes of your Universal Serial Bus (USB).
USB Control Chassis Index Name usbControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.1 Description Defines index (one-based) of this chassis. Syntax DellObjectRange Access Read-only USB Control Index Name usbControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.2 Description Defines the index (one-based) of the USB in this chassis. Syntax DellObjectRange Access Read-only USB Control Capabilities Name usbControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.
USB Control Status Name usbControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.5 Description Defines the status of the USB. Syntax DellStatus Access Read-only USB Control Name Name usbControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.6 Description Defines the setup BIOS name of the USB. Syntax DellString Access Read-only IDE Control Table These objects enable you to track the attributes of Integrated Device Electronics (IDE) controller cards in your system.
IDE Control Chassis Index Name ideControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only IDE Control Index Name ideControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.2 Description Defines the index (one-based) of the IDE controller in this chassis. Syntax DellObjectRange Access Read-only IDE Control Capabilities Unique Name ideControlCapabilitiesUnique Object ID 1.3.6.1.
IDE Control Status Name ideControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.5 Description Defines the status for the IDE controller. Syntax DellStatus Access Read-only IDE Control Name Name ideControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.6 Description Defines the setup BIOS name for the IDE controller. Syntax DellStatus Access Read-only Diskette Control Table Name disketteControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.
Diskette Control Chassis Index Name disketteControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Diskette Control Index Name disketteControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.2 Description Defines the index of the diskette controllers in this chassis.
Diskette Control Status Name disketteControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.5 Description Defines the status of the diskette controller. Syntax DellStatus Access Read-only Diskette Control Name Name disketteControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.6 Description Defines the setup BIOS name of the diskette controller.
Network Interface Control Chassis Index Name networkInterfaceControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Network Interface Control Index Name networkInterfaceControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.2 Description Defines the index (one-based) of the network interface controller in this chassis.
Network Interface Control Status Name networkInterfaceControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.5 Description Defines the status of the NIC. Syntax DellStatus Access Read-only Network Interface Control Name Name networkInterfaceControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.6 Description Defines the setup BIOS name of the NIC.
Table 16-2. Speaker Control Settings Unique Variable Name: DellSpeakerControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Speaker control state is unknown. enabled(2) Speaker control is enabled. low(4) Speaker control volume is low. medium(8) Speaker control volume is medium. high(16) Speaker control volume is high. Table 16-3.
Table 16-4. NIF Wakeup on LAN Control Settings Unique Variable Name: DellNIFwakeonLanControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) NIF Wakeup on LAN state is unknown. enabled(2) NIF Wakeup on LAN is enabled. addInCard(4) NIF Wakeup on LAN is by option card. onBoard(8) NIF Wakeup on LAN is by integrated NIF. addInCardOrOnBoard(12) NIF Wakeup on LAN is by option card or integrated NIF. Table 16-5.
Table 16-6. Boot Sequence Control Settings Unique Variable Name: DellBootSequenceControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value bootSequenceUnknown(1) Boot sequence state is unknown. bootFromDisketteFirst(2) Setup BIOS is set to boot by diskette first. bootFromHardDriveFirst(4) Setup BIOS is set to boot by IDE hard drive first. bootFromDeviceList(8) Setup BIOS is set to boot by a device list. bootFromCDROMFirst(16) Setup BIOS is set to boot by CD first.
Table 16-9. BIOS Password Control Settings Variable Name: DellBIOSPasswordControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value passwordControlSettingsUnknown(1) Setup BIOS password state is unknown. passwordControlEnabled(2) Setup BIOS has password changes enabled. passwordControlJumperDisabled(4) Setup BIOS has determined that password control has been disabled by a jumper. Table 16-10.
Table 16-11. Parallel Port Control Settings Variable Name: DellParallelPortControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Parallel port state is unknown. enabled(2) Setup BIOS has enabled the parallel port. lpt1(4) Setup BIOS supports parallel port 1. lpt1Enabled(6) Setup BIOS has enabled parallel port 1. lpt2(8) Setup BIOS supports parallel port 2. lpt2Enabled(10) Setup BIOS has enabled parallel port 2.
Table 16-13. Serial Port Control Capabilities Variable Name: DellSerialPortControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Setup BIOS serial port capabilities are unknown. enableCapable(2) Setup BIOS can enable the serial port. com1Capable(4) Setup BIOS can support serial port 1. enableAndCom1Capable(6) Setup BIOS can enable serial port 1. com2Capable(8) Setup BIOS can support serial port 2.
Table 16-14. Serial Port Control Settings Variable Name: DellSerialPortControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Serial port state is unknown. enabled(2) Setup BIOS has enabled the serial port. com1(4) Setup BIOS has selected serial port 1. com1Enabled(6) Setup BIOS has enabled serial port 1. com2(8) Setup BIOS has selected serial port 2. com2Enabled(10) Setup BIOS has enabled serial port 2. com3(16) Setup BIOS has selected serial port 3.
Table 16-16. Diskette Control Settings Variable Name: DellDisketteControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Diskette control state is unknown. disketteControlAutoConfigEnabledOrEnabled(2) Diskette control is set as autoconfigurable or enabled. Table 16-17.
BIOS Setup Control Group
Local Response Agent Group The Local Response Agent Group provides information about various attributes of your system’s local response agent (LRA). The LRA allows systems managers to predetermine how a system running the server administrator will respond to a particular event type, such as the loss of redundancy in a specific component or the elevation of temperature in a chassis. Systems managers can configure the LRA to respond to an event type with a specific action.
LRA Global Settings Table Entry Name lRAGlobalSettingsTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1 Description Defines the LRA Global Settings Table entry. Syntax LRAGlobalSettingsTableEntry Access Not accessible Index lRAGlobalchassisIndex LRA Global Chassis Index Name lRAGlobalchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.1 Description Defines the index (one-based) of this chassis.
LRA Global Settings Disable Time-out Value Name lRAGlobalSettingsDisableTimeoutValue Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.3 Description Defines the time-out duration countdown, in seconds, that the LRA global settings will be disabled after a system shutdown and reboot. Syntax DellUnsigned32BitRange Access Read-only LRA Global Settings Capabilities Unique Name lRAGlobalSettingsCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.
LRA Action Table The DellLocalResponseAgentCapabilitiesUnique variable in the global action table defines the capabilities that are allowed for a particular system. The LRA Action Table that follows selects which of the system’s capabilities (global actions) are to be enabled. Name lRAActionTableTable Object ID 1.3.6.1.4.1.674.10892.1.1500.20 Description Defines the LRA Action Table.
LRA Action Table Action Number Index Name lRAActionTableActionNumberIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.2 Description Defines the LRA action number index.
LRA Action Table User Application Name Name lRAActionTableUserApplicationName Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.3 Description When the "execute application value" is set, provides the following user-assignable LRA information: • Name of the user application executable path • File name to execute Syntax DisplayString (SIZE (0..256)) Access Read-write LRA Action Table Settings Unique Name lRAActionTableSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.
Table 17-2. LRA Thermal Shutdown Capabilities Unique Variable Name: DellLRAThermalShutdownCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value none(0) The LRA has no thermal shutdown capabilities. Unknown capabilities(1) The LRA’s thermal shutdown capabilities are unknown. enableCapable(2) The LRA can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).
Local Response Agent Group
Cost of Ownership Group The Cost of Ownership (COO) Group provides a full set of cost-tracking objects, including fields for the computer’s manufacturer, insurer, lessor, warranty, user, trouble tickets, and many others. You can use these management information base (MIB) objects to obtain accurate and complete measurements of the cost of each computer asset in your organization.
Cost of Ownership Table Entry Name cooTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1 Description Defines the Cost of Ownership Table entry. Syntax CooTableEntry Access Not accessible Index coochassisIndex COO Chassis Index Name coochassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.1 Description Defines the index (one-based) of this chassis. Syntax CooTableEntry Access Read-only COO State Name cooState Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.
COO Acquisition Waybill Number Name cooAquisitionWayBillNumber Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.4 Description Defines the waybill number of the system. Syntax DellUnsigned32BitRange Access Read-write COO Acquisition Install Date Name Name cooAquisitionInstallDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.5 Description Defines the installation date and time for the system.
COO Acquisition Signing Authority Name Name cooAquisitionSigningAuthorityName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.8 Description Defines the name of the authorized person who signs for the system. Syntax DellCostofOwnershipString Access Read-write COO Original Machine Configuration Expensed Name cooOriginalMachineConfigurationExpensed Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.9 Description Specifies whether the purchase of this system was expensed.
COO User Information User Name Name cooUserInformationUserName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.12 Description Defines the name of the user for this system. Syntax DellCostofOwnershipString Access Read-write COO Extended Warranty Start Date Name Name cooExtendedWarrantyStartDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.13 Description Defines the extended warranty start date for this system.
COO Extended Warranty Provider Name Name cooExtendedWarrantyProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.16 Description Defines the name of the extended warranty provider for this system. Syntax DellCostofOwnershipString Access Read-write COO Ownership Code Name cooOwnershipCode Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.17 Description Defines the ownership code for this system. Syntax DellCooOwnershipCodes (See Table 18-1.
COO Deployment Date Length Name cooDeploymentDateLength Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.20 Description Defines the deployment time for this system. Syntax DellUnsigned32BitRange Access Read-write COO Deployment Duration Type Name cooDeploymentDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.21 Description Defines the deployment time units for this system. Syntax DellCooHourDayDurationType (See Table 18-2.
COO Outsourcing Service Fee Name Name cooOutsourcingServiceFeeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.24 Description Defines amount that the outsourcing vendor charges for service. Syntax DellCostofOwnershipString Access Read-write COO Outsourcing Signing Authority Name Name cooOutsourcingSigningAuthorityName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.25 Description Defines the name of the person who can sign the authorization for service.
COO Insurance Company Name Name cooInsuranceCompanyName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.28 Description Defines the name of the company that insures this system. Syntax DellCostofOwnershipString Access Read-write COO Box Asset Tag Name Name cooBoxAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.29 Description Defines the name of the asset tag. Syntax DellCostofOwnershipString Access Read-write COO Box System Name Name cooBoxSystemName Object ID 1.3.6.1.4.1.674.
COO Operating System Upgrade Type Name Name cooOperatingSystemUpgradeTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.32 Description Defines the name of the operating system on this system. Syntax DellCostofOwnershipString Access Read-write COO Operating System Upgrade Patch Level Name Name cooOperatingSystemUpgradePatchLevelName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.33 Description Defines the name of the operating system patch level for this system.
COO Depreciation Duration Type Name cooDepreciationDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.36 Description Defines the unit of time for the depreciation of this system. Syntax DellCooMonthYearDurationType Access Read-write COO Depreciation Percentage Name cooDepreciationPercentage Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.37 Description Defines the percentage of depreciation for this system.
COO Service Contract Table The service contract table provides MIB objects that help you track the name, vendor, and type of service contract you have for your system. Name cooServiceContractTable Object ID 1.3.6.1.4.1.674.10892.1.1600.20 Description Defines the COO Service Contract Table. Syntax SEQUENCE OF CooServiceContractTableEntry Access Not accessible COO Service Contract Table Entry Name cooServiceContractTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.20.
COO Service Contract State Name cooServiceContractState Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.3 Description Defines the status of the service contract for this system. Syntax DellStateSettings Access Read-only COO Service Contract Was Renewed Name cooServiceContractWasRenewed Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.4 Description Specifies whether the service contract for this system was renewed.
COO Cost Event Log Table The COO Cost Event Log Table provides MIB objects that allow you to track the duration and type of events that are logged for a particular system. Name cooCostEventLogTable Object ID 1.3.6.1.4.1.674.10892.1.1600.30 Description Defines the COO Cost Event Log Table. Syntax SEQUENCE OF COO CostEventLogTableEntry Access Not accessible COO Cost Event Log Table Entry Name cooCostEventLogTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.30.
COO Cost Event Log State Name cooCostEventLogState Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.3 Description Defines the cost event log state of this system. Syntax DellStateSettings Access Read-only COO Cost Event Log Duration Name cooCostEventLogDuration Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.4 Description Defines the duration of the event for this system.
COO Warranty Table The COO Warranty Table objects enable you to track facts about the type and duration of the warranty for a particular system. Name cooWarrantyTable Object ID 1.3.6.1.4.1.674.10892.1.1600.40 Description Defines the COO Warranty Table. Syntax SEQUENCE OF CooWarrantyTableEntry Access Not accessible COO Warranty Table Entry Name cooWarrantyTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1 Description Defines the COO Warranty Table entry.
COO Warranty State Name cooWarrantyState Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.3 Description Defines the state of the warranty for this system. Syntax DellStateSettings Access Read-only COO Warranty Duration Name cooWarrantyDuration Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.4 Description Defines the duration of the warranty. Syntax DellUnsigned32BitRange Access Read-write COO Warranty Duration Type Name cooWarrantyDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.
COO Warranty Cost Name cooWarrantyCost Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.7 Description Defines the cost of the warranty for this system. Syntax DellUnsigned32BitRange Access Read-write COO Lease Information Table The COO lease information MIB objects enable you to track information about your lessor, lease duration, and lease type for each system. Name cooLeaseInformationTable Object ID 1.3.6.1.4.1.674.10892.1.1600.50 Description Defines the COO Lease Information Table.
COO Lease Information Index Name cooLeaseInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.2 Description Defines the index of the lease information for this system. Syntax DellObjectRange Access Read-only COO Lease Information State Name cooLeaseInformationState Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.3 Description Defines the lease information state for this system.
COO Lease Information Lease Rate Factor Name cooLeaseInformationLeaseRateFactor Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.6 Description Defines the rate factor for the lease on this system. Syntax DellUnsigned32BitRange Access Read-write COO Lease Information End Date Name Name cooLeaseInformationEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.7 Description Defines the end date for the lease on this system.
COO Schedule Number Table Name cooScheduleNumberTable Object ID 1.3.6.1.4.1.674.10892.1.1600.60 Description Defines the COO Schedule Number Information Table. Syntax SEQUENCE OF CooScheduleNumberTableEntry Access Not accessible COO Schedule Number Table Entry Name cooScheduleNumberTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1 Description Defines the COO Schedule Number Information Table entry.
COO Schedule Number State Name cooScheduleNumberState Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.3 Description Defines the schedule number information state of this system. Syntax DellStateSettings Access Read-only COO Schedule Number Lease Information Index Reference Name cooScheduleNumberLeaseInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.4 Description Defines the lease information index number to reference the schedule number.
COO Options Table Entry Name cooOptionsTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1 Description Defines the COO Options Table entry. Syntax CooOptionsTableEntry Access Not accessible Index cooOptionschassisIndex COO Options Chassis Index Name cooOptionschassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Options Index Name cooOptionsIndex Object ID 1.3.6.1.4.1.674.
COO Options Lease Information Index Reference Name cooOptionsLeaseInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.4 Description Defines the lease information index of the option information for this system. Syntax DellUnsigned32BitRange Access Read-write COO Options Description Name Name cooOptionsDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.5 Description Defines the option information description name.
COO Maintenance Chassis Index Name cooMaintenancechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Maintenance Index Name cooMaintenanceIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.2 Description Defines the index of this system’s maintenance information. Syntax DellObjectRange Access Read-only COO Maintenance State Name cooMaintenanceState Object ID 1.3.6.1.4.1.674.
COO Maintenance End Date Name Name cooMaintenanceEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.5 Description Defines the end date for maintenance on this system. Syntax DellDateName Access Read-write COO Maintenance Provider Name Name cooMaintenanceProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.6 Description Defines the maintenance provider’s name.
COO Repair Table Entry Name cooRepairTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1 Description Defines the COO Repair Table entry. Syntax CooRepairTableEntry Access Not accessible Index cooRepairchassisIndex, cooRepairIndex COO Repair Chassis Index Name cooRepairchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Repair Index Name cooRepairIndex Object ID 1.3.6.1.4.
COO Repair Counter Name cooRepairCounter Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.4 Description Defines the number of repairs that this system has undergone. Syntax DellCostofOwnershipString Access Read-write COO Repair Vendor Name Name cooRepairVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.5 Description Defines the name of the vendor that repairs this system.
COO Support Information Chassis Index Name cooSupportInformationchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Support Information Index Name cooSupportInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.2 Description Defines the index (one-based) for this system’s support information.
COO Support Information Type Name cooSupportInformationType Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.5 Description Defines the type of component, system, or network problem that occurred. Syntax DellUnsigned32BitRange Access Read-write COO Support Information Help Desk Name Name cooSupportInformationHelpDeskName Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.6 Description Defines the help desk information provided.
COO Trouble Ticket Table The MIB objects in the Trouble Ticket Table enable you to track details of any trouble tickets that you open for your system. Name cooTroubleTicketTable Object ID 1.3.6.1.4.1.674.10892.1.1600.110 Description Defines the COO Trouble Ticket Table. Syntax SEQUENCE OF cooTroubleTicketTableEntry Access Not accessible COO Trouble Ticket Table Entry Name cooTroubleTicketTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.110.
COO Trouble Ticket State Name cooTroubleTicketState Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.3 Description Defines the trouble ticket information state for this system. Syntax DellStateSettings Access Read-only COO Trouble Ticket Support Information Index Reference Name cooTroubleTicketSupportInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.4 Description Defines the support information index that references the trouble ticket.
Cost of Ownership Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 18-1. COO Ownership Codes Variable Name: DellCooOwnershipCodes Data Type: Integer Possible Data Values Meaning of Data Value other(1) The ownership code is not one of following: unknown(2) The ownership code is unknown. owned(3) The ownership code is owned. leased(4) The ownership code is leased. rented(5) The ownership code is rented.
Table 18-3. COO Day Month Duration Type Variable Name: DellCooDayMonthDurationType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Duration time type is unknown. days(3) Duration time type is in days. months(4) Duration time type is in months. Table 18-4. COO Month Year Duration Type Variable Name: DellCooMonthYearDurationType Data Type: Integer 386 Possible Data Values Meaning of Data Value unknown(1) Duration time type is unknown.
Remote Access Group The Remote Access Group provides information about the remote access hardware that may be present in your system. In addition to providing general information about the capabilities and settings of the remote access hardware, this group provides information about administrative users, SNMP trap destinations, modem configuration for dial-up networking, dial-in configuration, and dial-out destinations.
Remote Access Chassis Index Name remoteAccessChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote Access Adapter Index Name remoteAccessAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.2 Description Defines the index (one-based) of the remote access hardware.
Remote Access State Settings Name remoteAccessStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.5 Description Defines the state setting of the remote access hardware. Syntax DellStateSettings Access Read-write Remote Access Status Name remoteAccessStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.6 Description Defines the status of the remote access hardware. Syntax DellStatus Access Read-only Remote Access Product Info Name Name remoteAccessProductInfoName Object ID 1.3.6.1.
Remote Access Version Info Name Name remoteAccessVersionInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.9 Description Defines the version of the product providing the remote access functionality. Syntax DellDisplayString (SIZE (0..63)) Access Read-only Remote Access Local Area Network (LAN) Capabilities Name remoteAccessLANCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.14 Description Defines the LAN capabilities of the remote access hardware.
Remote Access NIC Static Netmask Address Name remoteAccessNICStaticNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.26 Description Defines the netmask for the static IP address to be used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-write Remote Access NIC Static Gateway Address Name remoteAccessNICStaticGatewayAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
Remote Access NIC Current IP Address Name remoteAccessNICCurrentIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.30 Description Defines the IP address currently being used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-only Remote Access NIC Current Netmask Address Name remoteAccessNICCurrentNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
Remote Access Remote Connect URL Name remoteAccessRemoteConnectURL Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.34 Description Defines the URL for launching the Remote Access Remote Connect Interface. Syntax DisplayString (SIZE (0..
Remote Access Chassis Index Name remoteAccessChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote Access Adapter Index Name remoteAccessAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.2 Description Defines the index (one-based) of the remote access hardware.
Remote Access State Settings Name remoteAccessStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.5 Description Defines the state setting of the remote access hardware. Syntax DellStateSettings Access Read-write Remote Access Status Name remoteAccessStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.6 Description Defines the status of the remote access hardware. Syntax DellStatus Access Read-only Remote Access Product Info Name Name remoteAccessProductInfoName Object ID 1.3.6.1.
Remote Access Version Info Name Name remoteAccessVersionInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.9 Description Defines the version of the product providing the remote access functionality. Syntax DellDisplayString (SIZE (0..63)) Access Read-only Remote Access Control Capabilities Name remoteAccessControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.10 Description Defines the control capabilities of the remote access hardware.
Remote Access Monitor Settings Name remoteAccessMonitorSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.13 Description Defines the monitor settings of the remote access hardware. Syntax DellRemoteAccessMonitorSettings (See Table 19-5) Access Read-write Remote Access Local Area Network (LAN) Capabilities Name remoteAccessLANCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.14 Description Defines the LAN capabilities of the remote access hardware.
Remote Access Host Settings Name remoteAccessHostSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.17 Description Defines the host settings of the remote access hardware. Syntax DellRemoteAccessHostSettings (See Table 19-9.) Access Read-write Remote Access Out-of-Band Simple Network Management Protocol (SNMP) Capabilities Name remoteAccessOutOfBandSNMPCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
Remote Access Floppy Trivial File Transfer Protocol (TFTP) IP Address Name remoteAccessFloppyTFTPIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.21 Description Defines the IP address of the TFTP server providing the operating system image used by the remote access hardware. Syntax IpAddress Access Read-write Remote Access Floppy TFTP Path Name Name remoteAccessFloppyTFTPPathName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
Remote Access Network Interface Controller (NIC) Static IP Address Name remoteAccessNICStaticIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.25 Description Defines the static IP address to be used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-write Remote Access NIC Static Netmask Address Name remoteAccessNICStaticNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
Remote Access Miscellaneous Information Name Name remoteAccessMiscInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.29 Description Defines the miscellaneous information for the remote access hardware. Syntax DisplayString (SIZE (0..63)) Access Read-write Remote Access NIC Current IP Address Name remoteAccessNICCurrentIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.30 Description Defines the IP address currently being used by the integrated NIC provided by the remote access hardware.
Remote Access NIC Current Information From Dynamic Host Configuration Protocol (DHCP) Name remoteAccessNICCurrentInfoFromDHCP Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.33 Description Defines whether DHCP was used to obtain the NIC information currently being used by the integrated NIC provided by the remote access hardware. Syntax DellBoolean Access Read-only Remote User Administration Table Name remoteUserAdminTable Object ID 1.3.6.1.4.1.674.10892.1.1700.
Remote User Admin Adapter Index Name remoteUserAdminAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.2 Description Defines the index (one-based) of the remote access hardware used by this remote access user. Syntax DellObjectRange Access Read-only Remote User Admin User Index Name remoteUserAdminUserIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.3 Description Defines the index (one-based) of this remote access user.
Remote User Admin Status Name remoteUserAdminStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.6 Description Defines the status for this remote access user. Syntax DellStatus Access Read-only Remote User Admin User Name Name remoteUserAdminUserName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.7 Description Defines the user name for this remote access user. Syntax DisplayString (SIZE (0..
Remote User Admin User Privilege Capabilities Name remoteUserAdminUserPrivilegeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.10 Description Defines the privilege capabilities for this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-only Remote User Admin Alert Filter DRS Events Mask Name remoteUserAdminAlertFilterDrsEventsMask Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.11 Description Defines the DRS events filter mask for this remote access user.
Remote User Admin Alert Filter System Capabilities Name remoteUserAdminAlertFilterSysCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.14 Description Defines the system events filter capabilities for this remote access user. Syntax DellUnsigned32BitRange Access Read-only Remote User Admin Pager Numeric Number Name Name remoteUserAdminPagerNumericNumberName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.15 Description Defines the numeric pager number for this remote access user.
Remote User Admin Pager Alpha Phone Number Name Name remoteUserAdminPagerAlphaPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.18 Description Defines the alphanumeric pager phone number for this remote access user. Syntax DisplayString (SIZE (0..95)) Access Read-write Remote User Admin Pager Alpha Protocol Name remoteUserAdminPagerAlphaProtocol Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
Remote User Admin Pager Alpha Modem Connect Time-out Name remoteUserAdminPagerAlphaModemConnectTimeout Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.22 Description Defines the modem connection time-out for the alphanumeric pager for this remote access user. Syntax DellUnsigned32BitRange Access Read-write Remote User Admin Pager Alpha Pager ID Name Name remoteUserAdminPagerAlphaPagerIdName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
Remote User Admin Pager Modem Port Name remoteUserAdminPagerModemPort Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.26 Description Defines the port for the pager modem for this remote access user. Syntax DellUnsigned32BitRange Access Read-write Remote User Admin E-Mail Address Name Name remoteUserAdminEmailAddressName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.27 Description Defines the e-mail address for this remote access user. Syntax DisplayString (SIZE (0..
Remote User Admin Control Settings Name remoteUserAdminControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.30 Description Defines the control settings for this remote access user. Syntax DellRemoteUserAdminControlSettings (See Table 19-15.) Access Read-write Remote User Admin User Type Name remoteUserAdminUserType Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.31 Description Defines the type of user for this remote access user.
Remote SNMP Trap Chassis Index Name remoteSNMPTrapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote SNMP Trap Adapter Index Name remoteSNMPTrapAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.2 Description Defines the index (one-based) of the remote access hardware that uses this SNMP trap destination.
Remote SNMP Trap State Settings Name remoteSNMPTrapStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.5 Description Defines the state settings of this remote access SNMP trap destination. Syntax DellRemoteSNMPTrapStateSettings (See Table 19-19.) Access Read-write Remote SNMP Trap Status Name remoteSNMPTrapStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.6 Description Defines the status of this remote access SNMP trap destination.
Remote SNMP Trap Filter DRS Events Mask Name remoteSNMPTrapFilterDrsEventsMask Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.9 Description Defines the DRS events filter mask for this remote access SNMP trap destination. Syntax DellUnsigned32BitRange Access Read-write Remote SNMP Trap Filter System Events Mask Name remoteSNMPTrapFilterSysEventsMask Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.10 Description Defines the system events filter mask for this remote access SNMP trap destination.
Remote SNMP Trap Control Capabilities Name remoteSNMPTrapControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.13 Description Defines the control capabilities of this remote access SNMP trap destination. Syntax DellRemoteSNMPTrapControlCapabilities (See Table 19-20.) Access Read-only Remote SNMP Trap Control Settings Name remoteSNMPTrapControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.14 Description Defines the control settings of this remote access SNMP trap destination.
Remote Dial-Up Chassis Index Name remoteDialUpChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote Dial-Up Adapter Index Name remoteDialUpAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.2 Description Defines the index (one-based) of the remote access hardware that supports this remote access dial-up functionality.
Remote Dial-Up State Settings Name remoteDialUpStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.5 Description Defines the state settings of this remote access dial-up functionality. Syntax DellRemoteDialUpStateSettings (See Table 19-23.) Access Read-write Remote Dial-Up Status Name remoteDialUpStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.6 Description Defines the status of this remote access dial-up functionality.
Remote Dial-Up PPP Dial-In Maximum Connection Time-out Name remoteDialUpPPPDialInMaxConnectTimeout Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.9 Description Defines the PPP connect time-out value in seconds for this remote access dial-up functionality. Syntax DellUnsigned32BitRange Access Read-write Remote Dial-Up Dial-Out Modem Connect Time-out Name remoteDialUpDialOutModemConnectTimeout Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.
Remote Dial-Up Modem Baud Rate Name remoteDialUpModemBaudRate Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.13 Description Defines the baud rate for the modem used by this remote access dial-up functionality. Syntax DellUnsigned32BitRange Access Read-write Remote Dial-Up Modem Port Name remoteDialUpModemPort Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.14 Description Defines the port for the modem used by this remote access dial-up functionality.
Remote User Dial-In Configuration Chassis Index Name remoteUserDialInCfgChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote User Dial-In Configuration Adapter Index Name remoteUserDialInCfgAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.
Remote User Dial-In Configuration State Settings Name remoteUserDialInCfgStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.5 Description Defines the state settings of this remote access dial-in user. Syntax DellRemoteUserDialInStateSettings (See Table 19-26.) Access Read-write Remote User Dial-In Configuration Status Name remoteUserDialInCfgStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.6 Description Defines the status of this remote access dial-in user.
Remote User Dial-In Configuration Callback Phone Number Name Name remoteUserDialInCfgCallbackPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.9 Description Defines the callback phone number for this remote access dial-in user. Syntax DisplayString (SIZE (0..95)) Access Read-write Remote Dial-Out Table Name remoteDialOutTable Object ID 1.3.6.1.4.1.674.10892.1.1700.60 Description Defines the Remote Access Dial-Out Table.
Remote Dial-Out Adapter Index Name remoteDialOutAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.2 Description Defines the index (one-based) of the remote access hardware that supports this remote access dial-out functionality. Syntax DellObjectRange Access Read-only Remote Dial-Out Dial-Out Index Name remoteDialOutDialOutIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.3 Description Defines the index (one-based) of this remote access dial-out functionality.
Remote Dial-Out Status Name remoteDialOutStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.6 Description Defines the status of this remote access dial-out functionality. Syntax DellStatus Access Read-only Remote Dial-Out IP Address Name remoteDialOutIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.7 Description Defines the IP address for this remote access dial-out destination.
Remote Dial-Out PPP Password Name Name remoteDialOutPPPPasswordName Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.10 Description Defines the PPP password for this remote access dial-out destination. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote Access Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 19-1.
Table 19-3. Remote Access Control Settings Variable Name: DellRemoteAccessControlSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no control settings. unknown(1) The remote access hardware control settings are unknown. logReset(2) The remote access hardware will reset its integrated logs. hardReset(4) The remote access hardware will perform a hard reset. softReset(8) The remote access hardware will perform a soft reset.
Table 19-5. Remote Access Monitor Settings Variable Name: DellRemoteAccessMonitorSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no monitor settings. unknown(1) The remote access hardware monitor settings are unknown. extPwrSupplyMonitorIfConnected Enabled(2) The remote access hardware will monitor the external power supply, if connected.
Table 19-8. Remote Access Host Capabilities Variable Name: DellRemoteAccessHostCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no host capabilities. unknownCapabilities(1) The remote access hardware host capabilities are unknown. smtpEmailCapable(2) The remote access hardware supports sending e-mail using SMTP. tftpRemoteFloppyCapable(4) The remote access hardware supports remote floppy boot using a TFTP server.
Table 19-10. Remote Access Out-Of-Band Simple Network Management Protocol (SNMP) Capabilities Variable Name: DellRemoteAccessOutOfBandSNMPCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no out-of-band SNMP capabilities. unknownCapabilities(1) The remote access hardware out-of-band SNMP capabilities are unknown. oobSNMPAgentCapable(2) The remote access hardware has an out-of-band SNMP agent.
Table 19-13. Remote User Admin State Settings Variable Name: DellRemoteUserAdminStateSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The admin user has no state settings. unknown(1) The admin user state settings are unknown. enabled(2) The admin user is enabled. notReady(4) The admin user is in the "not ready" state. numericPagerEnabled(8) Numeric paging is enabled for the admin user. alphaPagerEnabled(16) Alphanumeric paging is enabled for the admin user.
Table 19-16. Remote User Admin Alpha Protocol Type Variable Name: DellRemoteUserAdminAlphaProtocolType Data Type: Integer Possible Data Values Meaning of Data Value other(1) The remote user admin alpha protocol type is not one of the following: unknown(2) The remote user admin alpha protocol type is unknown. alpha7E0(3) The remote user admin alpha protocol type is 7E0. alpha8N1(4) The remote user admin alpha protocol type is 8N1. Table 19-17.
Table 19-19. Remote SNMP Trap State Settings Variable Name: DellRemoteSNMPTrapStateSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The SNMP trap destination has no state settings. unknown(1) The SNMP trap destination state settings are unknown. enabled(2) The SNMP trap destination is enabled. notReady(4) The SNMP trap destination is in the "not ready" state. Table 19-20.
Table 19-22. Remote Dial-Up State Capabilities Variable Name: DellRemoteDialUpStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-up functionality has no state capabilities. unknownCapabilities(1) The dial-up functionality state capabilities are unknown. enableCapable(2) The dial-up functionality can be disabled or enabled. notReadyCapable(4) The dial-up functionality can be in the "not ready" state.
Table 19-23. Remote Dial-Up State Settings (continued) Variable Name: DellRemoteDialUpStateSettings Data Type: Integer Possible Data Values Meaning of Data Value dialInDHCPEnabled(32) The dial-up functionality uses DHCP to obtain an IP address for the dial-in feature. dialInAuthAnyEnabled(64) The dial-up functionality accepts any authentication type (including clear text) for the dial-in feature.
Table 19-26. Remote User Dial-In State Settings Variable Name: DellRemoteUserDialInStateSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-in user has no state settings. unknown(1) The dial-in user state settings are unknown. enabled(2) The dial-in user is enabled. notReady(4) The dial-in user is in the "not ready" state. dialInCallbackPresetNumberEnabled(8) Callback using a preset number is enabled for the dial-in user.
Table 19-28. Remote Dial-Out State Settings Variable Name: DellRemoteDialOutStateSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-out destination has no state settings. unknown(1) The dial-out destination state settings are unknown. enabled(2) The dial-out destination is disabled or enabled. notReady(4) The dial-out destination is in the "not ready" state.
Remote Access Group
Cluster Group Clustering combines multiple systems in such a way that they provide services a single system could not. Clustering enhances higher availability, scalability, and management. Higher availability is achieved by using "failover" clusters, in which resources can automatically move between two or more systems in the event of a failure. Scalability is achieved by balancing the load of an application across several computer systems.
Cluster Chassis Index Name clusterChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Cluster Index Name clusterIndex Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.2 Description Defines the index (one-based) of the cluster. Syntax DellObjectRange Access Read-only Cluster State Capabilities Name clusterStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.
Cluster Status Name clusterStatus Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.5 Description Defines the status of the cluster. Syntax DellStatus Access Read-only Cluster Type Name clusterType Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.6 Description Defines the type of the cluster. Syntax DellClusterType Access Read-only Cluster Type Description Name Name clusterTypeDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.
Cluster Group Variable Values This section includes definitions for Server Administrator-specific variable values used in this section. Table 20-1. Cluster Type Variable Name: DellClusterType Data Type: Integer 440 Possible Data Values Meaning of Data Value unknown(1) The cluster type is unknown. highAvailabilityCluster(2) The cluster type is a high-availability cluster.
Baseboard Management Controller Group The Baseboard Management Controller (BMC) monitors the system for critical events by communicating with various sensors on the system board and sends alerts and log events when certain parameters exceed their preset thresholds. The BMC Group provides information about the BMC that may be present in your system. In addition to providing general information about the BMC, this group provides information about the serial and local area network (LAN) interfaces of the BMC.
BMC Table Entry Name bmcTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1 Description Defines the Baseboard Management Controller (BMC) Table Entry. Syntax BmcTableEntry Access Not accessible Index bmcChassisIndex, bmcIndex BMC Chassis Index Name bmcChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only BMC Index Name bmcIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.
BMC State Settings Name bmcStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.4 Description Defines the state settings of the BMC. Syntax DellStateSettings Access Read-write BMC Status Name bmcStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.5 Description Defines the status of the BMC. Syntax DellStatus Access Read-only BMC Display Name Name bmcDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.6 Description Defines the display name of the BMC.
BMC IPMI Version Name Name bmcIPMIVersionName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.8 Description Defines the version of the Intelligent Platform Management Interface (IPMI) specification that the BMC supports. Syntax DellString Access Read-only BMC GUID Name bmcGUID Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.9 Description Defines the Globally Unique ID (GUID) of the BMC.
BMC Serial Interface Chassis Index Name bmcSerialInterfaceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only BMC Serial Interface BMC Index Name bmcSerialInterfaceBMCIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.2 Description Defines the index (one-based) of the associated BMC.
BMC Serial Interface State Settings Name bmcSerialInterfaceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.5 Description Defines the state settings of the BMC serial interface. Syntax DellStateSettings Access Read-write BMC Serial Interface Status Name bmcSerialInterfaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.6 Description Defines the status of the BMC serial interface.
BMC Serial Interface Connection Mode Settings Name bmcSerialInterfaceConnectionModeSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.9 Description Defines the connection mode settings of the BMC serial interface. Syntax DellBMCSerialConnectionModeSettings Access Read-only BMC Serial Interface Flow Control Name bmcSerialInterfaceFlowControl Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.10 Description Defines the flow control type of the BMC serial interface.
BMC LAN Interface Table Entry Name bmcLANInterfaceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1 Description Defines the Baseboard Management Controller (BMC) LAN Interface Table Entry. Syntax BmcLANInterfaceTableEntry Access Not accessible Index bmcLANInterfaceChassisIndex, bmcLANInterfaceBMCIndex, bmcLANInterfaceIndex BMC LAN Interface Chassis Index Name bmcLANInterfaceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.
BMC LAN Interface State Capabilities Name bmcLANInterfaceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.4 Description Defines the state capabilities of the BMC LAN interface. Syntax DellStateCapabilities Access Read-only BMC LAN Interface State Settings Name bmcLANInterfaceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.5 Description Defines the state settings of the BMC LAN interface.
BMC LAN Interface IP Address Source Name bmcLANInterfaceIPAddressSource Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.8 Description Defines the source type of the IP address of the BMC LAN interface. Syntax DellBMCLANIPAddressSourceType Access Read-only BMC LAN Interface IP Address Name bmcLANInterfaceIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.9 Description Defines the IP address of the BMC LAN interface.
BMC LAN Interface MAC Address Name bmcLANInterfaceMACAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.12 Description Defines the MAC address of the BMC LAN interface. Syntax DellMACAddress Access Read-only BMC LAN Interface Alert Community Name Name bmcLANInterfaceAlertCommunityName Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.13 Description Defines the SNMP community used for BMC LAN alerts (traps) sent on the BMC LAN interface. Syntax DisplayString (SIZE (0..
Table 21-2. BMC Serial Connection Mode Settings Variable Name: DellBMCSerialConnectionModeSettings Data Type: Integer These values are bit masks; therefore, combination values are possible. Possible Data Values Meaning of Data Value -- none(0) No modes enabled. modemBasic(1) Modem Basic mode is enabled. modemPPP(2) Modem PPP mode is enabled. modemTerminal(4) Modem Terminal mode is enabled. directBasic(8) Direct Basic mode is enabled. directPPP(16) Direct PPP mode is enabled.
Table 21-5. BMC LAN IP Address Source Type Variable Name: DellBMCLANIPAddressSourceType Data Type: Integer Possible Data Values Meaning of Data Value -- unspecified(0) Source is unspecified. static(1) IP address is static. dhcp(2) Dynamic Host Configuration Protocol (DHCP) used to obtain IP address. biosOrSystemSoftware(3) BIOS or system software provided IP Address. other(4) Other protocol used to obtain IP address.
Baseboard Management Controller Group
Field Replaceable Unit Group A field replaceable unit (FRU) is a part that can be removed and replaced without having to send the system to a repair facility. The Field Replaceable Unit Group provides information about the field replaceable units that may be present in your system. Field Replaceable Unit Group Tables The objects in the FRU group define information such as manufacturer, serial number, part number and revision for field replaceable units.The following MIB tables define the FRU group.
FRU Chassis Index Name fruChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.1 Description Defines the index (one-based) of the chassis containing the FRU. Syntax DellObjectRange Access Read-only FRU Index Name fruIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.2 Description Defines the index (one-based) of the FRU. Syntax DellObjectRange Access Read-only FRU Information Status 456 Name fruInformationStatus Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.
FRU Information State Name fruInformationState Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.4 Description Defines the state of the FRU information. Some information for the FRU may not be available if the state is other than ok(1). Syntax DellFRUInformationState Access Read-only FRU Device Name Name fruDeviceName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.5 Description Defines the device name of the FRU. Syntax DisplayString (SIZE (0..
FRU Part Number Name Name fruPartNumberName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.8 Description Defines the part number of the FRU Syntax DisplayString (SIZE (0..64)) Access Read-only FRU Revision Name Name fruRevisionName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.9 Description Defines the revision of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only FRU Manufacturing Date Name Name fruManufacturingDateName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.
FRU Group Variable Values This section includes definitions for server administrator-specific variable values. Table 22-1. FRU Information State Variable Name: DellFRUInformationState Data Type: Integer Possible Data Values Meaning of Data Value ok(1) FRU information is OK. notSupported(2) FRU information is not supported. notAvailable(3) FRU information is not available. checksumInvalid(4) FRU information checksum is invalid. corrupted(5) FRU information is corrupted.
Field Replaceable Unit Group
Storage Management Group The Storage Management Group is composed of the following: • Storage Management Group—information about the software product and system status. • Storage Management Information Group—properties about the Simple Network Management Protocol (SNMP) agent. • Global Data Group—system status. • Physical Devices Group—physical devices managed by the software. • Logical Devices Group—logical devices managed by the software. • Storage Management Event Group—SNMP traps.
Global Status Name globalStatus Object ID 1.3.6.1.4.1.674.10893.1.20.2 Description Identifies global health for the subsystem managed by the Storage Management software. This global status is customized for HP OpenView. Other applications should refer to the agentSystemGlobalStatus entry in the globalData object group. Possible values: 1: Critical 2: Warning 3: Normal 4: Unknown Syntax Integer Access Read-only Software Manufacturer Name softwareManufacturer Object ID 1.3.6.1.4.1.674.10893.1.20.
Storage Management Information Group The Storage Management Information MIB Group defines the properties that identify the Storage Management software SNMP agent. Display Name Name displayName Object ID 1.3.6.1.4.1.674.10893.1.20.100.1 Description Identifies the name of this management software for display purposes. Syntax DisplayString Access Read-only Description Name description Object ID 1.3.6.1.4.1.674.10893.1.20.100.2 Description Provides a short description of this management software.
Global Data Group The Global Data Management Information Base (MIB) Group defines the properties that identify status information about the system that the Storage Management software is managing and about the Storage Management SNMP agent. Agent System Global Status Name agentSystemGlobalStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.1 Description This entry is obsolete. Use the value agentGlobalSystemStatus.
Agent Get Timeout Name agentGetTimeout Object ID 1.3.6.1.4.1.674.10893.1.20.110.4 Description Indicates the suggested timeout value in milliseconds for how long the SNMP getter should wait while attempting to poll the SNMP agent. Syntax Integer Access Read-only Agent Modifiers Name agentModifiers Object ID 1.3.6.1.4.1.674.10893.1.20.110.5 Description Identifies the agent functional modifiers. When set, the modifier is active. Bit definitions: Bit 3: agent in debug mode.
Agent IP Address Name agentIPAddress Object ID 1.3.6.1.4.1.674.10893.1.20.110.8 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Agent Software Status Name agentSoftwareStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.9 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Agent SNMP Version Name agentSnmpVersion Object ID 1.3.6.1.4.1.674.10893.1.20.110.10 Description This entry is obsolete.
Agent Management Software URL Name Name agentManagementSoftwareURLName Object ID 1.3.6.1.4.1.674.10893.1.20.110.12 Description Identifies the Universal Resource Locator (URL) of the systems management software. Syntax DisplayString Access Read-only Agent Global System Status Name agentGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.13 Description Global health information for the subsystem managed by the Storage Management software.
Agent Last Global System Status Name agentLastGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.14 Description The previous global status of the system managed by the Storage Management software. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Agent Smart Thermal Shutdown Name agentSmartThermalShutdown Object ID 1.3.6.1.4.1.674.10893.1.20.110.
Physical Devices Group The Physical Devices MIB group provides information about the devices managed by the Storage Management software and their relationships to each other. The following MIB tables define objects and relationships (connections) among the objects. • Controller Table—describes available properties for each controller on the managed system. • Channel Table—describes available properties for each channel on the managed system.
Controller Table This table describes available properties for each controller on the managed system. The following object sets up the Controller Table. Name controllerTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.1 Description Defines the controller table, which is a table of managed Redundant Array of Independent disks (RAID) controllers. The number of entries is related to the number of RAID controllers discovered in the system.
Controller Name Name controllerName Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.2 Description Identifies the name of the controller in this subsystem as represented in Storage Management. Includes the controller type and instance. For example: PERC 3/QC 1. Syntax DisplayString Access Read-only Controller Vendor Name controllerVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.3 Description Identifies the controller's (re)seller's name.
Controller State Name controllerState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.5 Description Identifies the status of the controller's subsystem (which includes any devices connected to it). Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded Syntax Integer Access Read-only Controller Severity Name controllerSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.6 Description This entry is obsolete for Storage Management.
Controller Firmware Version Name controllerFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.8 Description Identifies the controller's current firmware version. Syntax DisplayString Access Read-only Controller Cache Size in Megabytes Name controllerCacheSizeInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.9 Description Identifies the controller's current amount of cache memory in megabytes. If this size is 0, it is less than a megabyte.
Controller Logical Device Count Name controllerLogicalDeviceCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.12 Description Identifies the number of virtual disks on the controller. Syntax Integer Access Read-only Controller Partner Status Name controllerPartnerStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.13 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Controller Host Port Count Name controllerHostPortCount Object ID 1.3.6.
Controller Memory Size in Bytes Name controllerMemorySizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.16 Description Identifies the size of memory on the controller that is less than a megabyte. This combined with the controllerMemorySizeInMB will be the total size of the memory. This attribute is only supported on Adaptec controllers. Syntax Integer Access Read-only Controller Drive Channel Count Name controllerDriveChannelCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Controller C0 Port 0 Name Name controllerC0Port0Name Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.20 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Controller C0 Port 0 ID Name controllerC0Port0ID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.21 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Controller C0 Operating System Controller Name controllerC0OSController Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.24 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Controller C0 Battery State Name controllerC0BatteryState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.25 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Controller C1 Port 0 ID Name controllerC1Port0ID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.28 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller C1 Target Name controllerC1Target Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.29 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Controller Battery State C1 Name controllerC1BatteryState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.32 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller Node World Wide Name Name controllerNodeWWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.33 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Controller Battery Charge Count Name controllerBatteryChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.36 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller Roll-Up Status Name controllerRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.37 Description Indicates severity of the controller state. This is the combined status of the controller and its components.
Controller Nexus ID Name controllerNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.39 Description Durable unique ID for this controller. Syntax DisplayString Access Read-only Controller Alarm State Name controllerAlarmState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.40 Description Indicates state, or setting for the controller's alarm.
Controller Cluster Mode Name controllerClusterMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.43 Description Identifies if the controller is in cluster mode. Possible values: 1: Enabled 2: Disabled 3: Active (enabled and active) 99: Not Applicable Syntax Integer Access Read-only Controller Minimum Firmware Version Name controllerMinFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.44 Description The minimum firmware version for Storage Management to support the controller.
Controller Channel Count Name controllerChannelCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.47 Description The number of channels on the controller. Syntax Integer Access Read-only Controller Reconstruct Rate Name controllerReconstructRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.48 Description The rate for reconstruct on the controller. Syntax Integer Access Read-write Controller Patrol Read Rate Name controllerPatrolReadRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Controller Check Consistency Rate Name controllerCheckConsistencyRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.51 Description The rate for check consistency on the controller. Syntax Integer Access Read-only Controller Patrol Read Mode Name controllerPatrolReadMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.52 Description Identifies the patrol read mode.
Controller Patrol Read Iterations Name controllerPatrolReadIterations Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.54 Description The number of times Patrol Read has been run on this controller. Syntax Integer Access Read-only Channel Table This table describes available properties for each channel on the managed system. The following object sets up the Channel Table. Name channelTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.2 Description Defines the channel table.
Channel Name Name channelName Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.2 Description Identifies the name of the channel as represented in Storage Management. The name will include the word channel and the instance. For example: Channel 1. Syntax DisplayString Access Read-only Channel State Name channelState Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.3 Description Identifies the current state of this channel. Possible states: 0: Unknown 1: Ready - The I/O has resumed.
Channel Termination Name channelTermination Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.5 Description Identifies the type of SCSI termination on this channel. Termination is required for proper operation of this channel. Possible values: 1: Wide Termination (16 bit) 2: Narrow Termination (8 bit) 3: Not Terminated Syntax Integer Access Read-only Channel SCSI ID Name channelSCSIID Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.
Channel Component Status Name channelComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.8 Description The status of the channel itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Channel Nexus ID Name channelNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.9 Description Durable unique ID for this channel.
Channel Bus Type Name channelBusType Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.11 Description The bus type of the channel. Possible values: 1: SCSI 2: IDE 3: Fibre Channel 4: Serial Storage Architecture (SSA) 6: Universal Serial Bus (USB) 7: SATA 8: SAS Syntax Integer Access Read-only Enclosure Table This table describes available properties for each enclosure on the managed system. The following object sets up the Enclosure Table. Name enclosureTable Object ID 1.3.6.1.4.1.674.10893.1.20.
Enclosure Number Name enclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.1 Description Identifies the instance number of the enclosure entry. Syntax Integer Access Read-only Enclosure Name Name enclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.2 Description Identifies the enclosure's name as represented in Storage Management. Syntax DisplayString Access Read-only Enclosure Vendor Name enclosureVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
Enclosure Severity Name enclosureSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Enclosure ID Name enclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.6 Description Identifies the SCSI address of the processor. Syntax Integer Access Read-only Enclosure Processor Version Name enclosureProcessorVersion Object ID 1.
Enclosure Asset Tag Name enclosureAssetTag Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.9 Description Customer definable asset tag for the enclosure. Syntax DisplayString Access Read-only Enclosure Asset Name Name enclosureAssetName Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.10 Description Customer definable asset name of the enclosure. Syntax DisplayString Access Read-only Enclosure Split Bus Part Number Name enclosureSplitBusPartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
Enclosure Kernel Version Name enclosureKernelVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.13 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Enclosure ESM1 Part Number Name enclosureESM1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.14 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Enclosure ESM2 Part Number Name enclosureESM2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.
Enclosure Type Name enclosureType Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.16 Description Indicates the type of the enclosure. Possible values: 1: Internal 2: Dell™ PowerVault™ 200S (PV201S) 3: Dell PV210S (PV211S) 4: Dell PV220S (PV221S) 5: Dell PV660F 6: Dell PV224F 7: Dell PV660F/PV224F 8: Dell MD1000 Syntax DisplayString Access Read-only Enclosure Processor2 Version Name enclosureProcessor2Version Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
Enclosure Channel Number Name enclosureChannelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.19 Description Identifies the channel number, or bus, to which the enclosure is connected. Syntax Integer Access Read-only Enclosure Alarm Name enclosureAlarm Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.20 Description Identifies the current status of the enclosure's alarm (PV220S and PV221S only.
Enclosure Roll-Up Status Name enclosureRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.23 Description Identifies the severity of the enclosure state. This is the combined status of the enclosure and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Enclosure Component Status Name enclosureComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
Enclosure FirmWare Version Name enclosureFirmwareVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.26 Description The firmware version of the enclosure. Syntax DisplayString Access Read-only Enclosure SCSI Rate Name enclosureSCSIRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.27 Description Actual SCSI rate in the enclosure. Syntax Octet String Access Read-only Enclosure Part Number Name enclosurePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
Array Disk Table This table describes available properties for each physical array disk on the managed system. The following object sets up the Array Disk Table. Name arrayDiskTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.4 Description Defines the array disk table. Syntax SEQUENCE OF ArrayDiskEntry Access Not accessible Array Disk Entry Name arrayDiskEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1 Description Defines the array disk table entry.
Array Disk Vendor Name arrayDiskVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.3 Description The array disk's manufacturer's name. Syntax DisplayString Access Read-only Array Disk State Name arrayDiskState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.4 Description Identifies the current state of the array disk. Possible states: 0: Unknown 1: Ready - Available for use, but no RAID configuration has been assigned. 2: Failed - Not operational. 3: Online - Operational.
Array Disk Severity Name arrayDiskSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Array Disk Product ID Name arrayDiskProductID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.6 Description Identifies the model number of the array disk.
Array Disk Enclosure ID Name arrayDiskEnclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.9 Description Identifies the SCSI ID of the enclosure processor to which this array disk belongs. Syntax DisplayString Access Read-only Array Disk Channel Name arrayDiskChannel Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.10 Description Identifies the bus to which this array disk is connected.
Array Disk Largest Contiguous Free Space in Megabytes Name arrayDiskLargestContiguousFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.13 Description The size in megabytes of the largest contiguous free space on the array disk. If this size is 0, it is less than a megabyte. Syntax Integer Access Read-only Array Disk Largest Contiguous Free Space in Bytes Name arrayDiskLargestContiguousFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Array Disk Used Space in Megabytes Name arrayDiskUsedSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.17 Description Identifies the amount in megabytes of the used space on the array disk. If this size is 0, it is smaller than a megabyte. Syntax Integer Access Read-only Array Disk Used Space in Bytes Name arrayDiskUsedSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.18 Description Identifies the size in bytes of the used space on the array disk that is smaller than a megabyte.
Array Disk Bus Type Name arrayDiskBusType Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.21 Description Identifies the bus type of the array disk. Possible values: 1: SCSI 2: IDE 3: Fibre Channel 4: SSA 6: USB 7: SATA 8: SAS Syntax Integer Access Read-only Array Disk Spare State Name arrayDiskSpareState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.22 Description Identifies the status of the array disk as a spare.
Array Disk Roll-Up Status Name arrayDiskRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.23 Description Severity of the array disk state. This is the combined status of the array disk and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Array Disk Component Status Name arrayDiskComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Array Disk Nexus ID Name arrayDiskNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.26 Description Indicates the durable unique ID for this array disk. Syntax DisplayString Access Read-only Array Disk Part Number Name arrayDiskPartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.27 Description Indicates the part number of the disk. Syntax DisplayString Access Read-only Array Disk SAS Address Name arrayDiskSASAddress Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Array Disk Capable Speed Name arrayDiskCapableSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.30 Description Indicates the maximum speed at which the drive is capable of negotiating in MPS (megabytes per second). Syntax Integer Access Read-only Array Disk Smart Alert Indication Name arrayDiskSmartAlertIndication Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.31 Description Indicates whether the disk has received a predictive failure.
Array Disk Manufacture Week Name arrayDiskManufactureWeek Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.33 Description The week (1 through 53) in which this disk was manufactured. Syntax DisplayString Access Read-only Array Disk Manufacture Year Name arrayDiskManufactureYear Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.34 Description The four digit year in which this disk was manufactured.
Array Disk Enclosure Connection Entry Name arrayDiskEnclosureConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1 Description Defines the array disk enclosure connection table entry. Syntax ArrayDiskEnclosureConnectionEntry Access Not accessible Index arrayDiskEnclosureConnectionNumber Array Disk Enclosure Connection Number Name arrayDiskEnclosureConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.
Array Disk Enclosure Connection Enclosure Name Name arrayDiskEnclosureConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.4 Description Identifies the name of the enclosure as represented in Storage Management to which this array disk belongs. Syntax DisplayString Access Read-only Array Disk Enclosure Connection Enclosure Number Name arrayDiskEnclosureConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.
Array Disk Channel Connection Table This table describes the connections between array disks, their channel, and their associated controller. For each object in the table, its object "number" corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found. NOTE: Only array disks that are NOT part of an enclosure will be listed in this table. Backplanes are considered enclosures by Storage Management.
Array Disk Channel Connection Array Disk Name Name arrayDiskChannelConnectionArrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.2 Description Identifies the name of the array disk in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Array Disk Channel Connection Array Disk Number Name arrayDiskChannelConnectionArrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.
Array Disk Channel Connection Controller Name Name arrayDiskChannelConnectionControllerName Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.6 Description Identifies the name of the controller as represented in Storage Management to which this array disk is connected. Syntax DisplayString Access Read-only Array Disk Channel Connection Controller Number Name arrayDiskChannelConnectionControllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.
Fan Number Name fanNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.1 Description Identifies the instance number of the fan entry. Syntax Integer Access Read-only Fan Name Name Fan Name Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.2 Description Identifies the fan's name as represented in Storage Management. Syntax DisplayString Access Read-only Fan Vendor Name fanVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.3 Description Identifies the fan's (re)seller's name.
Fan Severity Name fanSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Fan Probe Unit Name fanProbeUnit Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.6 Description This entry is obsolete for Storage Services. Syntax DisplayString Access Read-only Fan Probe Minimum Warning Name fanProbeMinimumWarning Object ID 1.3.6.1.4.
Fan Probe Maximum Warning Name fanProbeMaximumWarning Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.9 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Fan Probe Maximum Critical Name fanProbeMaximumCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.10 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management.
Fan 2 Part Number Name fan2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.13 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Fan Roll-Up Status Name fanRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.14 Description Severity of the fan state. This is the combined status of the fan and its components.
Fan Nexus ID Name fanNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.16 Description Durable unique ID for this fan. Syntax DisplayString Access Read-only Fan Revision Name fanRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.17 Description Indicates the revision number of the fan in the enclosure. Syntax DisplayString Access Read-only Fan Connection Table This table describes the connection between each fan on the managed system and its enclosure.
Fan Connection Number Name fanConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.1 Description Identifies the instance number of the fan connection entry. Syntax Integer Access Read-only Fan Connection Fan Name Name fanConnectionFanName Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.2 Description Identifies the name of the fan in this connection as represented in Storage Management.
Fan Connection Enclosure Number Name fanConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.5 Description Identifies the instance number of the enclosure in the enclosureTable to which this fan belongs. Syntax Integer Access Read-only Power Supply Table This table describes available properties for each power supply on the managed system. The following object sets up the Power Supply Table. Name powerSupplyTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.
Power Supply Name Name powerSupplyName Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.2 Description Identifies the power supply's name as represented in Storage Management. Syntax DisplayString Access Read-only Power Supply Vendor Name powerSupplyVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.3 Description Identifies the power supply's (re)seller's name. Syntax DisplayString Access Read-only Power Supply State Name powerSupplyState Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.
Power Supply 1 Part Number Name powerSupply1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.6 Description Identifies the part number of the power supply of the enclosure. Syntax DisplayString Access Read-only Power Supply 2 Part Number Name powerSupply2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.7 Description This entry is obsolete.
Power Supply Component Status Name powerSupplyComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.9 Description Severity of the power supply state. This is the combined status of the power supply and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Power Supply NexusID Name powerSupplyNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.10 Description Durable unique ID for this power supply.
Power Supply Connection Table This table describes the connection between each power supply on the managed system and its enclosure. Each enclosure "number" in the table corresponds to that enclosure instance in the enclosure Table. The following object sets up the Power Supply Connection Table. Name powerSupplyConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.10 Description Defines the power supply connection table.
Power Supply Connection Power Supply Number Name powerSupplyConnectionPowerSupplyNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.3 Description Identifies the instance number of the power supply in the powerSupplyTable in the connection. Syntax Integer Access Read-only Power Supply Connection Enclosure Name Name powerSupplyConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.
Temperature Probe Table This table describes available properties for each temperature probe on the managed system. The following object sets up the Temperature Probe Table. Name temperatureProbeTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.11 Description A table of managed temperature probes. The number of entries is related to the number of temperature probes discovered in the system. The maximum number of entries is implementation dependent.
Temperature Probe Vendor Name temperatureProbeVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.3 Description Identifies the temperature probe's (re)seller's name. Syntax DisplayString Access Read-only Temperature Probe State Name temperatureProbeState Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.4 Description Identifies the current state of the temperature probe.
Temperature Probe Unit Name temperatureProbeUnit Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.6 Description The units that will be used to display temperatures for the temperature probe. Syntax DisplayString Access Read-only Temperature Probe Minimum Warning Name temperatureProbeMinWarning Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.7 Description Identifies the minimum temperature that will force the probe into a warning state.
Temperature Probe Maximum Critical Name temperatureProbeMaxCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.10 Description Identifies the maximum temperature that will force the probe into an error state. Syntax Integer Access Read-only Temperature Probe Current Value Name temperatureProbeCurValue Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.11 Description Identifies the current temperature of this probe.
Temperature Probe Component Status Name temperatureProbeComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.13 Description The status of the temperature probe itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Temperature Probe Nexus ID Name temperatureProbeNexusID Object ID .3.6.1.4.1.674.10893.1.20.130.11.1.
Temperature Probe Connection Entry Name temperatureConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1 Description Defines the temperature probe connection table entry. Syntax TemperatureConnectionEntry Access Not accessible Index temperatureConnectionNumber Temperature Probe Connection Number Name temperatureConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.1 Description Identifies the instance number of the temperature probe connection entry.
Temperature Probe Connection Enclosure Name Name temperatureConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.4 Description Identifies the name of the enclosure as represented in Storage Management to which this temperature probe belongs. Syntax DisplayString Access Read-only Temperature Probe Connection Enclosure Number Name temperatureConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.
Enclosure Management Module Number Name enclosureManagementModuleNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.1 Description Identifies the instance number of the enclosure management module entry. Syntax Integer Access Read-only Enclosure Management Module Name Name enclosureManagementModuleName Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.2 Description Identifies the enclosure management module's name as represented in Storage Management.
Enclosure Management Module State Name enclosureManagementModuleState Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.4 Description Identifies the current state of the enclosure management module. Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 5: Not Installed 6: Degraded 21: Missing Syntax Integer Access Read-only Enclosure Management Module Severity Name enclosureManagementModuleSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.
Enclosure Management Module Type Name enclosureManagementModuleType Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.7 Description Identifies the type of the enclosure management module. Possible values: 0: Unknown 1: EMM 2: Termination Card Syntax Integer Access Read-only Enclosure Management Module Firmware Version Name enclosureManagementModuleFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.8 Description Identifies the firmware version of the enclosure memory module.
Enclosure Management Module Roll-Up Status Name enclosureManagementModuleRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.10 Description Severity of the enclosure management module state. This is the combined status of the EMM and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Enclosure Management Module Component Status Name enclosureManagementModuleComponentStatus Object ID 1.3.6.1.4.1.674.
Enclosure Management Module Revision Name enclosureManagementModuleRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.13 Description Identifies the revision number of the enclosure management module. Syntax DisplayString Access Read-only Enclosure Management Module Connection Table This table describes the connection between each enclosure management module on the managed system and its enclosure.
Enclosure Management Module Connection EMM Name Name enclosureManagementModuleConnectionEMMName Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.2 Description Identifies the name of the enclosure memory module in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Enclosure Management Module Connection EMM Number Name enclosureManagementModuleConnectionEMMNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.
Battery Table This table describes available properties for each controller battery on the managed system. The following object sets up the Battery Table. Name batteryTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.15 Description Defines the battery table. Syntax SEQUENCE OF BatteryEntry Access Not accessible Battery Entry Name batteryEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1 Description Defines the battery table entry.
Battery Vendor Name batteryVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.3 Description Identifies the battery's (re)seller's name. Syntax DisplayString Access Read-only Battery State Name batteryState Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.4 Description Identifies the current state of battery.
Battery Roll-Up Status Name batteryRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.5 Description Severity of the battery state. This is the combined status of the battery and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Battery Component Status Name batteryComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.
Battery Max Charge Count Name batteryMaxChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.8 Description The maximum number of charges that can be applied to the battery. Syntax Integer Access Read-only Battery Nexus ID Name batteryNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.9 Description Durable unique ID for this EMM. Syntax DisplayString Access Read-only Battery Predicted Capacity Name batteryPredictedCapacity Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.
Battery Learn State Name batteryLearnState Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.12 Description Specifies the learn state activity of the battery. Possible values: 1: Failed 2: Active 4: Timed out 8: Requested 16: Idle Syntax Integer Access Read-only Battery Maximum Learn Delay Name batteryMaxLearnDelay Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.14 Description The maximum amount of time (in hours) that the battery learn cycle can be delayed.
Battery Connection Entry Name batteryConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1 Description Defines the battery connection table entry. Syntax BatteryConnectionEntry Access BatteryConnectionEntry Index BatteryConnectionNumber Battery Connection Number Name batteryConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.1 Description Identifies the instance number of the battery connection entry.
Battery Connection Controller Name Name batteryConnectionControllerName Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.4 Description Identifies the name of the controller as represented in Storage Management to which this battery belongs. Syntax DisplayString Access Read-only Battery Connection Controller Number Name batteryConnectionControllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.
Virtual Disk Table This table describes available properties for each virtual disk on the managed system. The following object sets up the Virtual Disk Table. Name virtualDiskTable Object ID 1.3.6.1.4.1.674.10893.1.20.140.1 Description Defines the virtual disk table. Syntax SEQUENCE OF VirtualDiskEntry Access Not accessible Virtual Disk Entry Name virtualDiskEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1 Description Defines the virtual disk table entry.
Virtual Device Disk Name Name virtualDiskDeviceName Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.3 Description Identifies the device name used by this virtual disk's member disks. Syntax DisplayString Access Read-only Virtual Disk State Name virtualDiskState Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.4 Description Identifies the current state of this virtual disk. Possible states: 0: Unknown 1: Ready - The disk is accessible and has no known problems.
Virtual Disk Severity Name virtualDiskSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Virtual Disk Length in Megabytes Name virtualDiskLengthInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.6 Description Identifies the size of this virtual disk in megabytes. If this size is 0, it is smaller than a megabyte.
Virtual Disk Free Space in Bytes Name virtualDiskFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.9 Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax Integer Access Read-only Virtual Disk Write Policy Name virtualDiskWritePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.10 Description Indicates whether the controller's write cache will be used when writing to a virtual disk.
Virtual Disk Cache Policy Name virtualDiskCachePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.12 Description Indicates whether the controller's cache is used when reading from or writing to a virtual disk. Possible values: 1: Direct I/O (LSI) 2: Cached I/O (LSI) 99: Not Applicable Syntax Integer Access Read-only Virtual Disk Layout Name virtualDiskLayout Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.13 Description Indicates the virtual disk's RAID type.
Virtual Disk Current Stripe Size in Bytes Name virtualDiskCurStripeSizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.15 Description Identifies the portion of the stripe size in bytes that is smaller than a megabyte. This size plus the virtualDiskCurStripeSizeInMB is the total stripe size on the virtual disk. Syntax Integer Access Read-only Virtual Disk Channel Name virtualDiskChannel Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.16 Description This entry is obsolete.
Virtual Disk Roll-Up Status Name virtualDiskRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.19 Description Severity of the virtual disk state. This is the combined status of the virtual disk and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Virtual Disk Component Status Name virtualDiskComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
Virtual Disk Array Disk Type Name virtualDiskArrayDiskType Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.22 Description Identifies the type of array (physical) disks used to create the virtual disk. Possible values: 1: SAS 2: SATA 3: SCSI 4: IDE 99: Unknown Syntax Integer Access Read-only Array Disk Logical Connection Table This table describes the connections between array disks, the virtual disk to which they belong, and their associated logical disk.
Array Disk Logical Connection Number Name arrayDiskLogicalConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.1 Description Identifies the instance number of the disk entry. Syntax Integer Access Read-only Array Disk Logical Connection Array Disk Name Name arrayDiskLogicalConnectionArrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.2 Description Identifies the name of the array disk in this logical connection.
Array Disk Logical Connection Virtual Disk Number Name arrayDiskLogicalConnectionVirtualDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.5 Description Identifies the instance number of the virtual disk to which this array disk belongs. Syntax Integer Access Read-only Array Disk Logical Connection Disk Name Name arrayDiskLogicalConnectionDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.6 Description Identifies the name of the disk group to which this array disk belongs.
Storage Management Event Group The Storage Management Event Group defines the properties that will be sent with SNMP traps. Message ID Event Name messageIDEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.1 Description Storage Management event message number. Syntax Integer Access Read-only Description Event Name descriptionEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.2 Description Storage Management event message text describing the alert.
Object OID Event Name objectOIDEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.5 Description MIB OID of the object causing the alert. Syntax DisplayString Access Read-only Object Nexus Event Name objectNexusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.6 Description Durable, unique ID of the object causing the alert. Syntax DisplayString Access Read-only Current Status Event Name currentStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.
Storage Management Group
Change Management Group The Change Management Group lets you monitor information about the Dell™ devices and software that are present on a particular managed computer chassis. This information is collected during an inventory scan. Inventory Group The following objects describe the fields for inventory information. Inventory Locale Name inventoryLocale Object ID 1.3.6.1.4.1.674.10899.1.1 Description Defines the locale of the system.
Device Group The Device Group defines information about the devices discovered on the system during an inventory scan. Identifying information includes the Component ID, the Device ID, and the Vendor ID. Device Group Table The following object sets up the Device Group Table. Name deviceTable Object ID 1.3.6.1.4.1.674.10899.1.5 Description Defines the Device Table. Syntax SEQUENCE OF DeviceEntry Access Not accessible Device Entry Name deviceEntry Object ID 1.3.6.1.4.1.674.10899.1.5.
Device Display String Name deviceDisplayString Object ID 1.3.6.1.4.1.674.10899.1.5.1.3 Description Provides a displayable string that describes the device. Syntax DisplayString Access Read-only Device Vendor ID Name deviceVendorID Object ID 1.3.6.1.4.1.674.10899.1.5.1.4 Description Defines the ID for the vendor supplying the device. Syntax Octet String Access Read-only Device ID Name deviceDeviceID Object ID 1.3.6.1.4.1.674.10899.1.5.1.5 Description Defines the ID for the device.
Device Sub Vendor ID Name deviceSubVendorID Object ID 1.3.6.1.4.1.674.10899.1.5.1.7 Description Provides additional vendor identification. Syntax Octet String Access Read-only Application Group NOTE: Dell updateable components such as Basic input/output system (BIOS) and FirmWare (FW) are considered applications.
Application Index Name applicationIndex Object ID 1.3.6.1.4.1.674.10899.1.6.1.1 Description Defines the unique index for this application. Syntax Unsigned16BitRange Access Read-only Application Device Index Name applicationDeviceIndex Object ID 1.3.6.1.4.1.674.10899.1.6.1.2 Description Defines a cross-index to the device table for the application. Syntax Unsigned16BitRange Access Read-only Application Component Type Name applicationComponentType Object ID 1.3.6.1.4.1.674.10899.1.6.1.
Application Display String Name applicationDisplayString Object ID 1.3.6.1.4.1.674.10899.1.6.1.5 Description A user visible display string that describes the application. Syntax DisplayString Access Read-only Application Sub-Component ID Name applicationSubComponentID Object ID 1.3.6.1.4.1.674.10899.1.6.1.6 Description The sub-component ID for the application. This is usually valid on ESM device reporting.
Operating System Minor Version Name operatingSystemMinorVersion Object ID 1.3.6.1.4.1.674.10899.2.3 Description Defines the minor version of the Operating System. Syntax DisplayString Access Read-only Operating System Service Pack Major Version Name operatingSystemSPMajorVersion Object ID 1.3.6.1.4.1.674.10899.2.5 Description Defines the Operating System's Service Pack major version.
Inventory Collector Product Information The following objects describe the fields for the Inventory Collector. The Inventory Collector product variables are scalar objects, meaning that they are not related to other Inventory Collector base (MIB) objects and are thus not placed in a table. Product ID Display Name Name productIDDisplayName Object ID 1.3.6.1.4.1.674.10899.100.1 Description Defines the display name of the product.
Product ID Version Name productIDVersion Object ID 1.3.6.1.4.1.674.10899.100.4 Description Describes the version of the product. Syntax DisplayString Access Read-only Product ID Build Number Name productIDBuildNumber Object ID 1.3.6.1.4.1.674.10899.100.5 Description Describes the software build number of the product.
Change Management Group
Traps The Server Administrator generates events that result in Simple Network Management Protocol (SNMP) traps or operating system event logs. This section describes the traps, also known as alerts, generated by the SNMP subagent of Server Administrator. The Server Administrator generates events in response to changes in the status of sensors and other monitored parameters.
Table Index OID Variable Name alertTableIndexOID Object ID 1.3.6.1.4.1.674.10892.1.5000.10.2 Description Gives the object identifier for the index attribute in the table that contains the object causing the alert. Uniquely identifies the object causing the alert and can be used to correlate different alerts caused by the same object. Syntax OBJECT IDENTIFIER Message Variable Name alertMessage Object ID 1.3.6.1.4.1.674.10892.1.5000.10.3 Description Describes the alert.
Understanding the Trap Description Table 25-1 lists in alphabetical order each line item that may appear in the trap description. Table 25-1.
Table 25-1. Trap Description Reference (continued) Description Line Item Explanation Date and time of action: Specifies the date and time that an automatic server recovery action was performed, for example: Date and time of action: Fri May 30 23:55:44 2003.
Table 25-1.
Server Administrator SNMP Traps This section describes the traps that are generated by the SNMP subagent of Server Administrator. All of the traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.674.10892.1 and are sent with all of the trap variables documented in the section, "Trap Variables." The trap variables are sent in the order in which they are listed.
Miscellaneous Traps Miscellaneous traps inform you that certain alert systems are up and working. Table 25-2. Trap ID Miscellaneous Traps Description Severity Cause Information Server Administrator completed its initialization. Error This message is generated when a system is configured for thermal shutdown due to an error event. If a temperature sensor reading exceeds the error threshold for which the system is configured, the operating system shuts down and the system powers off.
Temperature Probe Traps Temperature probes help protect critical components by alerting the systems management console when temperatures become too high inside a chassis. The temperature probe traps use additional variables: sensor location, chassis location, previous state, and temperature sensor value reported in degrees Celsius. Table 25-3.
Table 25-3. Temperature Probe Traps (continued) Trap ID Description Severity Cause Error A temperature sensor on the backplane board, system board, or drive carrier in the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and temperature sensor value are provided. Error A temperature sensor on the backplane board, system board, or drive carrier in the specified system detected an error from which it cannot recover.
Cooling Device Traps Cooling device traps monitor how well a fan is functioning. Table 25-4. Cooling Device Traps Trap ID Description Severity Cause Information A fan sensor reading on the specified system returned to a valid range after crossing a warning threshold. The sensor location, chassis location, previous state, and fan sensor value are provided. Warning A fan sensor reading in the specified system exceeded a warning threshold.
Voltage Probe Traps Voltage probes monitor the number of volts across critical components. Table 25-5. Voltage Probe Traps Trap ID Description Severity Cause Information A voltage sensor in the specified system returned to a valid range after crossing a failure threshold. The sensor location, chassis location, previous state, and voltage sensor value are provided. Warning A voltage sensor in the specified system exceeded its warning threshold.
Table 25-5. Voltage Probe Traps (continued) Trap ID Description Severity Cause Error A voltage sensor in the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and voltage sensor value are provided. Error A voltage sensor in the specified system detected an error from which it cannot recover. The sensor location, chassis location, previous state, and voltage sensor value are provided.
Amperage Probe Traps Amperage probes measure the amount of current (in amperes) that is traversing critical components. Table 25-6. Amperage Probe Traps Trap ID Description Severity Cause Information A current sensor on the power supply for the specified system returned to a valid range after crossing a failure threshold. The sensor location, chassis location, previous state, and current sensor value are provided.
Table 25-6. Amperage Probe Traps (continued) Trap ID Description Severity Cause Error A current sensor on the power supply for the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and current sensor value are provided. Error A current sensor in the specified system detected an error from which it cannot recover. The sensor location, chassis location, previous state, and current sensor value are provided.
Chassis Intrusion Traps Chassis intrusion traps are a security measure. Chassis intrusion means that someone is opening the cover to a system’s chassis. Alerts are sent to prevent unauthorized removal of parts from a chassis. Table 25-7. Trap ID Chassis Intrusion Traps Description Severity Cause Information A chassis intrusion sensor in the specified system detected that a cover was opened while the system was operating but has since been replaced.
Table 25-8. Trap ID Redundancy Unit Traps Description Severity Cause Information A redundancy sensor in the specified system detected that a "lost" redundancy device has been reconnected or replaced; full redundancy is in effect. The redundancy unit location, chassis location, and previous redundancy state are provided. Warning A redundancy sensor in the specified system detected that one of the components of the redundancy unit has failed but the unit is still redundant.
Power Supply Traps Power supply traps provide status and warning information for power supplies present in a particular chassis. Table 25-9. Trap ID Power Supply Traps Description Severity Cause Information A power supply has been reconnected or replaced. The sensor location, chassis location, previous state, and additional information about the power supply event are provided. Warning A power supply sensor has detected a warning condition.
Table 25-9. Trap ID Power Supply Traps (continued) Description Severity Cause Error A power supply has been disconnected or has failed. The sensor location, chassis location, previous state, and additional information about the power supply event are provided.
Memory Device Traps Memory device messages provide status and warning information for memory modules present in a particular system. Memory devices determine health status by counting the number of ECC memory corrections. NOTE: A value of failure or non-recoverable does not indicate a system failure or loss of data, but rather that the specified system exceeded the specified ECC correction threshold.
Fan Enclosure Traps Some systems are equipped with a protective enclosure for fans. Fan enclosure traps monitor enclosures for whether foreign objects are present and for how long a fan enclosure is absent from a chassis. Table 25-11. Fan Enclosure Traps Trap ID Description Severity Cause Fan Enclosure Insertion 1452 Fan enclosure inserted into system Information Sensor location: Chassis location: A fan enclosure has been inserted into the specified system.
AC Power Cord Traps The AC power cord sensor monitors the presence of AC power for an AC power cord. AC power cord traps provide status and warning information for power cords that are part of an AC power switch, if your system supports AC switching. Table 25-12. AC Power Cord Traps Trap ID Description Severity Cause Information The AC power cord status is not being monitored. This occurs when a system’s expected AC power configuration is set to nonredundant.
Table 25-13. Trap ID Hardware Log Traps Description Severity Cause Information The hardware log on the specified system is no longer near or at its capacity, usually as the result of clearing the log. The log type information is provided. Warning The size of a hardware log on the specified system is near or at the capacity of the hardware log. The log type information is provided. Error The size of a hardware log on the specified system is at the capacity of the hardware log.
Processor Device Status Traps The BMC on some systems reports the status of processor devices. Processor device status traps provide status and warning information for processor devices present in a system with a BMC that reports the status of processor devices. Table 25-14. Processor Device Status Traps Trap ID Description Severity Cause Information A processor sensor in the specified system transitioned back to a normal state.
Pluggable Device Traps Server Administrator monitors the addition and removal of pluggable devices such as memory cards. Device traps provide information about the addition and removal of such devices. Table 25-15. Pluggable Device Traps Trap ID Description Severity Cause Information A device was added to the specified system. The device location, chassis location, and additional event details, if available, are provided. Information A device was removed from the specified system.
Battery Traps The BMC on some systems reports the status of batteries. Battery traps provide status and warning information for batteries present in a system with a BMC that reports the status of batteries. Table 25-16. Battery Traps Trap ID Description Severity Cause Informational A battery sensor in the specified system detected that a battery transitioned back to a normal state. The sensor location, chassis location, previous state, and battery sensor status are provided.
RAC Traps This section describes the traps that are generated by the SNMP agent of the Remote Access Controller (RAC). All of the enterprise-specific traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.674.10892.2 and are sent with all of the trap variables documented in the section “Traps”. The trap variables are sent in the order in which they are listed. Table 25-17.
Table 25-18. Enterprise-specific Traps (continued) Trap ID Name Description Severity Category Cause Supported by RAC Platform 1005 alertDrscPower The RAC has Critical Off detected a system power state change to powered-off Error RAC detected a system DRAC III power state change to power-off. 1006 alertDrscPower The RAC has Information On detected a system power state change to powered-on Error RAC detected a system DRAC III power state change to power-on.
Table 25-18. 596 Enterprise-specific Traps (continued) Trap ID Name Description Severity Category Cause Supported by RAC Platform 1013 alertDrscVolt Warning The RAC voltage probe has detected a warning value Minor Error RAC voltage probe reading exceeded warning threshold. DRAC III 1014 alertDrscVolt Critical The RAC voltage probe has detected a failure (or critical) value Critical Error RAC voltage probe reading exceeded critical threshold.
BMC Traps The BMC monitors the system for critical events by communicating with various sensors on the system board and by sending alerts and log events when certain parameters exceed their preset thresholds. All of the traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.3183.1.1.1. Table 25-19.
Table 25-19.
Table 25-19.
Traps
Storage Management Alert Reference Storage Management’s alert or event management features let you monitor the health of storage resources such as controllers, connectors, array disks, and virtual disks. Alert Monitoring and Logging The Storage Management Service performs alert monitoring and logging. By default, the Storage Management Service starts when the managed system starts up. If you stop the Disk Management Service, then alert monitoring and logging stops.
Alert Severity Levels Each alert message in the Storage Management alert log has a severity level. The severity level is displayed in the Severity field of the alert message. The severity level indicates the nature of the alert. The alert severity levels are as follows: Table 26-1. Storage Management Alert Severity Alert Severity Component Status OK/Normal/Informational No action is required. The alert is provided for informational purposes and does not indicate an error condition.
See your Windows operating system documentation for information on configuring the operating system to forward SNMP traps. This information may be located under such topics as “setting up SNMP” or “SNMP traps.” When configuring SNMP for Windows, be sure that the SNMP traps are forwarded to the correct server. For information on configuring an application to receive SNMP traps, see the documentation for that application.
Alert Descriptions and Corrective Actions The following sections describe alerts generated by the Redundant Array of Independent disks (RAID) or Small Computer System Interface (SCSI) controllers supported by Storage Management. The alerts are displayed in the Server Administrator Alert subtab or through Windows Event Viewer. These alerts can also be forwarded as SNMP traps to other applications. SNMP traps are generated for the alerts listed in the following sections.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers 2050 Array disk offline Warning / Non-critical Cause: A physical disk in the array is offline. A disk can 903 be made offline during a Prepare to Remove operation or because a user manually put the disk offline. Array Manager Event Number 502 Action: Perform a rescan. You can also select the offline disk and perform a Make Online operation.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers 2057 Virtual disk degraded Warning / Non-critical Cause 1: This alert message occurs when a physical disk 1203 included in a redundant virtual disk fails. Because the virtual disk is redundant (uses mirrored or parity information) and only one physical disk has failed, the virtual disk can be rebuilt.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers Array Manager Event Number 2064 Virtual disk OK/Normal/ Cause: This alert is provided for informational purposes. 1201 rebuild started Informational Action: None. 526 2065 Array disk OK/Normal/ Cause: This alert is provided for informational purposes. 901 rebuild started Informational Action: None.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers 2077 Virtual disk format failed Critical / Cause: An array disk included in the virtual disk failed. 1204 Failure / Error Action: Replace the array disk. You can identify which array disk has failed by locating the disk that has a red "X" for its status. Rebuild the array disk. When finished, restart the virtual disk format operation.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers 2085 Virtual disk check consistency completed OK/Normal/ Cause: This alert is provided for informational purposes. 1201 Informational Action: None. 547 2086 Virtual disk format completed OK/Normal/ Cause: This alert is provided for informational purposes. 1201 Informational Action: None.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers Array Manager Event Number Cause: An array disk has failed, is corrupt, or is otherwise experiencing a problem. 903 571 2098 Global hot OK/Normal/ Cause: A user has assigned an array disk as a global hot 901 spare assigned Informational spare. This alert is provided for informational purposes. 574 2095 SCSI sense Warning / data %1.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action 2100 Temperature exceeded the maximum warning threshold Warning / Non-critical Cause: The array disk enclosure is too hot. A variety of 1053 factors can cause the excessive temperature. For example, a fan may have failed, the thermostat may be set too high, or the room temperature may be too hot. Array Manager Event Number 591 Action: Check for factors that may cause overheating.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers Array Manager Event Number 2105 Controller OK/Normal/ Cause: This alert is provided for informational purposes. 1151 battery Informational Action: None.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity 2109 Smart warning Warning / temperature Non-critical Cause and Action SNMP Trap Numbers Array Manager Event Number Cause: A disk has reached an unacceptable temperature and received a SMART alert (predictive failure). The disk is likely to fail in the near future. 903 588 Cause: A disk is degraded and has received a SMART 903 alert (predictive failure). The disk is likely to fail in the near future.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action 2112 Enclosure was Critical / Cause: The array disk enclosure is either hotter or shut down Failure / Error cooler than the maximum or minimum allowable temperature range. SNMP Trap Numbers Array Manager Event Number 854 602 1201 604 Action: Check for factors that may cause overheating or excessive cooling. For example, verify that the enclosure fan is working.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action 2118 Change write OK/Normal/ Cause: A user has changed the write policy for a policy Informational virtual disk. SNMP Trap Numbers Array Manager Event Number 1201 601 Action: This alert is provided for informational purposes. 2120 Enclosure firmware mismatch Warning / Non-critical Cause: The firmware on the Expanded Memory 853 Manager (EMM) modules is not the same version.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers 2123 Redundancy lost Warning / Non-critical Cause: A virtual disk or an enclosure has lost data 1306 redundancy. In the case of a virtual disk, one or more array disks included in the virtual disk have failed. Due to the failed array disk or disks, the virtual disk is no longer maintaining redundant (mirrored or parity) data.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers 2127 Background initialization started OK/Normal/ Cause: Background initialization of a virtual disk has 1201 Informational started. This alert is provided for informational purposes. 2128 Background initialization cancelled OK/Normal/ Cause: Background initialization of a virtual disk has Informational been cancelled.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity 2135 Array Manager Warning / is installed on Non-critical the system 2136 Virtual disk initialization Cause and Action SNMP Trap Numbers Array Manager Event Number Cause: Storage Management has been installed on a system that has an Array Manager installation. 103 None 1201 None Action: Installing Storage Management and Array Manager on the same system is not a supported configuration.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers 2140 Dead disk segments restored 1201 OK/Normal/ Cause: Disk space that was formerly “dead” or Informational inaccessible to a redundant virtual disk has been restored. This alert is provided for informational purposes. Array Manager Event Number None Action: None.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers Array Manager Event Number 2149 Bad block extended sense error Warning / Non-critical Cause: A portion of an array disk is damaged. See the online help for more information. 753 691 753 691 851 None 851 None Cause: An enclosure service tag was changed. In most 853 circumstances, this service tag should only be changed by Dell support or your service provider.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers 2158 Array disk online OK/Normal/ Cause: An offline array disk has been made online. This 901 Informational alert is provided for informational purposes. Array Manager Event Number None Action: None. 2159 Virtual disk renamed OK/Normal/ Cause: A user has renamed a virtual disk. This alert is Informational provided for informational purposes.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action 2162 Communicati OK/Normal/ Cause: Communication with an enclosure has been on regained Informational restored. This alert is provided for informational purposes. SNMP Trap Numbers Array Manager Event Number 851 None 904 690 Action: None. 2163 Rebuild completed with errors 622 Critical / Cause: See "A Rebuild Completes with Errors" in Failure / Error online help for more information.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers 2166 The RAID Warning / controller Non-critical firmware and driver validation was not performed. The configuration file is out of date or corrupted. Cause: Storage Management is unable to determine 753 whether the system has the minimum required versions of the RAID controller firmware and drivers. This situation has occurred because a configuration file is unreadable or missing data.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers 2169 The controller Critical/Failure Cause: The controller battery cannot recharge. The 1154 battery needs /Error battery may be old or it may have been already to be replaced. recharged the maximum number of times. In addition, the battery charger may not be working. Array Manager Event Number None Action: Replace the battery pack.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity SNMP Trap Numbers Array Manager Event Number 2176 The controller OK/Normal/ Cause: This alert is provided for informational battery Learn Informational purposes. cycle has Action: None. started. 1151 None 2177 The controller OK/Normal/ Cause: This alert is provided for informational battery Learn Informational purposes. cycle has Action: None. completed.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers Array Manager Event Number 2181 The controller OK/Normal/ Cause: This alert is provided for informational purposes. 1151 battery Learn Informational Action: None. cycle will start in % hours. The %1 indicates a substitution variable. The text for this substitution variable is displayed with the alert in the Alert Log and can vary depending on the situation.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity 2188 The controller Warning/ write policy Non-critical has been changed to Write Through. Cause and Action SNMP Trap Numbers Cause: The controller battery is unable to maintain 1153 cached data for the required period of time. For example, if the required period of time is 24 hours, then the battery is unable to maintain cached data for 24 hours. It is normal to receive this alert during the battery Learn cycle.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers 2193 The virtual disk reconfigure has resumed. OK/Normal/ Cause: This alert is provided for informational purposes. 1201 Informational Action: None. None 2194 The virtual disk read policy has changed. OK/Normal/ Cause: This alert is provided for informational purposes. 1201 Informational Action: None. None 2199 The virtual disk cache policy has changed.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity 2204 A dedicated Warning/ hot spare has Non-critical been removed. Cause and Action SNMP Trap Numbers Cause: The controller is not able to communicate with 903 a disk that is assigned as a dedicated hot spare. The disk may have been removed. There may also be a bad or loose cable. Array Manager Event Number None Action: Verify that the disk is healthy and that it has not been removed. Check the cables.
Table 26-2. Storage Management Messages (continued) Event Description ID 630 Severity Cause and Action SNMP Trap Numbers Array Manager Event Number 2232 The controller OK/Normal/ Cause: This alert is provided for informational purposes. 751 alarm is Informational Action: None. silenced. None 2233 The OK/Normal/ Cause: This alert is provided for informational purposes. 751 background Informational Action: None. initialization (BGI) rate has changed.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers Array Manager Event Number 2244 A virtual disk OK/Normal/ Cause: This alert is provided for informational purposes. 1201 blink has been Informational Action: None. initiated. None 2245 A virtual disk blink has ceased. None OK/Normal/ Cause: This alert is provided for informational purposes. 1201 Informational Action: None.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action Array Manager Event Number 2255 The array disk OK/Normal/ Cause: This alert is provided for informational purposes. 901 has started. Informational Action: None. None 2259 An enclosure OK/Normal/ Cause: This alert is provided for informational purposes. 851 blink Informational Action: None. operation has initiated. None 2260 An enclosure blink has ceased.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers 2265 A device is in an unknown state. Warning/ Non-critical Cause: The controller cannot communicate with a device. The state of the device cannot be determined. There may be a bad or loose cable. The system may also be experiencing problems with the application programming interface (API). There could also be a problem with the driver or firmware.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity 2268 %1, Storage Critical/ Management Failure/ has lost Error communicatio n with this RAID controller and attached storage. An immediate reboot is strongly recommended to avoid further problems. If the reboot does not restore communicatio n, then there may be a hardware failure. The %1 indicates a substitution variable.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity 2270 The array disk Critical/ Clear Failure/ operation Error failed. Cause and Action SNMP Trap Numbers Cause: A Clear task was being performed on an array 904 disk but the task was interrupted and did not complete successfully. The controller may have lost communication with the disk. They disk may have been removed or the cables may be loose or defective.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers Array Manager Event Number Cause: The battery is discharging. A battery discharge is a normal activity during the battery Learn cycle. Before completing, the battery Learn cycle recharges the battery. You should receive alert 2179 when the recharge occurs. 1151 None 1151 None 1201 None OK/Normal/ Cause: This alert is provided for informational purposes.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity 2283 A redundant Warning/ path is broken. Non-critical Cause and Action SNMP Trap Numbers Cause: The controller has two connectors that are 903 connected to the same enclosure. The communication path on one connector has lost connection with the enclosure. The communication path on the other connector is reporting this loss.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers 2289 Multi-bit ECC error. Critical/ Failure/ Error Cause: An error involving multiple bits has been 754 encountered during a read or write operation. The error correction algorithm recalculates parity data during read and write operations. If an error involves only a single bit, it may be possible for the error correction algorithm to correct the error and maintain parity data.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers Array Manager Event Number 2294 A device has OK/Normal/ Cause: This alert is provided for informational purposes. 752, 802, None been inserted. Informational Action: None. 852, 902, 952, 1002, 1052, 1102, 1152, 1202 2295 A device has Critical/ been removed. Failure/ Error Cause: A device has been removed and the system is no 754, 804, None longer functioning in optimal condition.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers Array Manager Event Number 2299 Bad PHY %1. Critical/ The %1 Failure/ indicates a Error substitution variable. The text for this substitution variable is displayed with the alert in the Alert Log and can vary depending on the situation. Cause: There is a problem with a physical connection or PHY. 854 None 2300 The enclosure Critical/ is unstable.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers Array Manager Event Number 2303 The enclosure OK/Normal/ Cause: This alert is provided for informational purposes. 851 cannot Informational Action: None. support both SAS and SATA array disks. Array disks may be disabled. None 2304 An attempt to OK/Normal/ Cause: This alert is provided for informational purposes. 751 hot plug an Informational Action: None.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers Array Manager Event Number 2307 Bad block Critical/ table is full. Failure/ Unable to log Error block %1. The %1 indicates a substitution variable. The text for this substitution variable is displayed with the alert in the Alert Log and can vary depending on the situation. Cause: The bad block table is the table used for remapping bad disk blocks.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity 2311 The firmware Warning/ on the Non-critical enclosure management modules (EMMs) is not the same version. EMM0 %1 EMM1 %2 Cause and Action SNMP Trap Numbers Cause: The firmware on the EMM modules is not the 853 same version. It is required that both modules have the same version of the firmware.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity 2314 The Critical/ initialization Failure/ sequence of Error SAS components failed during system startup. SAS management and monitoring is not possible. Cause and Action SNMP Trap Numbers Array Manager Event Number Cause: Storage Management is unable to monitor or manage SAS devices. 104 None 751 None Action: Reboot the system. If problem persists, make sure you have supported versions of the drivers and firmware.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers Array Manager Event Number Cause: A diagnostics test failed. The text for this alert is generated by the utility that ran the diagnostics. 754 None 2317 Background OK/Normal/ Cause: This alert is provided for informational initialization Informational purposes. (BGI) Action: None. terminated due to loss of ownership in a cluster configuration.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity SNMP Trap Numbers 2320 Single-bit Critical/ ECC error. Failure/ The dual Error in-line memory module (DIMM) is critically degraded. Cause: The DIMM is malfunctioning. Data loss or data 754 corruption may be imminent. 2321 Single-bit ECC error. The dual inline memory module (DIMM) is critically degraded. There will be no further reporting.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action 2325 The power supply cable has been inserted. OK/Normal/ Cause: This alert is provided for informational Informational purposes. SNMP Trap Numbers Array Manager Event Number 1001 None 751 None Action: None. 2326 A foreign OK/Normal/ configuration Informational has been detected. Cause: This alert is provided for informational purposes.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers Array Manager Event Number 2330 SAS port OK/Normal/ Cause: This alert is provided for informational purposes. 751 report: %1. Informational Action: None. The %1 indicates a substitution variable. The text for this substitution variable is displayed with the alert in the Alert Log and can vary depending on the situation.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers Array Manager Event Number 751 None Cause: The text for this alert is generated by the 753 controller and can vary depending on the situation. This text is from events in the controller event log that were generated while Storage Management was not running. None 2334 Controller OK/Normal/ Cause: This alert is provided for informational event log: %1. Informational purposes.
Table 26-2. Storage Management Messages (continued) Event Description ID 650 Severity Cause and Action SNMP Trap Numbers 2336 Controller Critical/ event log: %1. Failure/ The %1 Error indicates a substitution variable. The text for this substitution variable is displayed with the alert in the Alert Log and can vary depending on the situation. Cause: The text for this alert is generated by the 754 controller and can vary depending on the situation.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity 2340 The Critical/ background Failure/ initialization Error (BGI) completed with uncorrectable errors. Cause and Action SNMP Trap Numbers Cause: The BGI task encountered errors that cannot be 1204 corrected. The virtual disk contains array disks that have unusable disk space or disk errors that cannot be corrected. Array Manager Event Number None Action: Replace the array disk that contains the disk errors.
Table 26-2. 652 Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers Array Manager Event Number 2345 The virtual disk initialization failed. Critical/ Failure/ Error Cause: The controller cannot communicate with attached devices. A disk may be removed or contain errors. Cables may also be loose or defective. 1204 None 903 None 904 None 904 None 904 None Action: Verify the health of attached devices.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity 2350 There was an Critical/ unrecoverable Failure/ disk media Error error during the rebuild. Cause and Action SNMP Trap Numbers Cause: The rebuild encountered an unrecoverable disk 904 media error. Array Manager Event Number None Action: Replace the disk. 2351 A physical disk OK/Normal/ Cause: This alert is provided for informational purposes. 901 is marked as Informational Action: None. missing.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity 2356 SAS Critical/ Management Failure/ Protocol Error (SMP) communications error %1. The %1 indicates a substitution variable. The text for this substitution variable is displayed with the alert in the Alert Log and can vary depending on the situation. 2357 SAS expander Critical/ error: %1. The Failure/ %1 indicates a Error substitution variable.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers Array Manager Event Number 2359 The physical disk is not certified. Warning/ Non-critical Cause: The physical disk does not comply with the standards set by Dell and is not supported. 903 None 2360 A user has OK/Normal/ Cause: This alert is provided for informational purposes. 751 discarded data Informational Action: None. from the controller cache.
Table 26-2. Storage Management Messages (continued) Event Description ID 656 Severity Cause and Action SNMP Trap Numbers Array Manager Event Number 2363 A virtual disk OK/Normal/ Cause: This alert is provided for informational purposes. 751 and all of its Informational Action: None. member array disks have been removed while the system was shut down. This removal was discovered during system start-up. None 2364 All virtual OK/Normal/ Cause: This alert is provided for informational purposes.
Table 26-2. Storage Management Messages (continued) Event Description ID Severity Cause and Action SNMP Trap Numbers 2368 The Scalable OK/Normal/ Cause: This alert is provided for informational purposes. 851 Encryption Informational Action: None. Processor (SEP) has been rebooted as part of the firmware download operation and will be unavailable until the operation completes.
Storage Management Alert Reference
Standard Data Type Definitions This appendix contains definitions for data types that are standard in most contexts across the information technology industry. These are the most common data types for expressing variable values defined in the 10892.mib, dcs3rmt.mib and dcs3fru.mib files. Server Administrator-specific variable values are defined in the last section of the section in which they are introduced.
Variables with Data Types of State Capabilities and State Capabilities Unique Variables with definitions of StateCapabilities or StateCapabilitiesUnique are integers representing a series of bit definitions. They are NOT enumerations and should be treated as bit fields. The value is passed as a decimal value. The decimal value should be converted to hex and the appropriate bits should be parsed from hex.
Table A-4. Dell Probe Capabilities Variable Name: DellProbeCapabilities Data Type: Integer Possible Data Values Meaning of Data Value if set to zero(0) The object has no capabilities. upperNonCriticalThresholdSetCapable(1) The upper noncritical threshold can be set. lowerNonCriticalThresholdSetCapable(2) The lower noncritical threshold can be set. upperNonCriticalThresholdDefaultCapable(4) The upper noncritical threshold can be set to default.
Table A-6. Dell Status Redundancy Variable Name: DellStatusRedundancy Data Type: Integer Possible Data Values Meaning of Data Value other(1) The object’s status is not one of the following: unknown(2) The object’s redundancy status is unknown. full(3) The object is fully redundant. degraded(4) The object’s redundancy has been degraded. lost(5) The object’s redundancy has been lost. notRedundant(6) Redundancy does not apply or it is not redundant. Table A-7.
Dell Date Variable Name: DellDate Data Type: DellUnsigned64BitRange OCTET STRING (SIZE(8)) The DellDate definition is required because SNMP V1 does not support 64-bit ranges. The information sent back by this subagent will have the most significant byte of the information as the first byte. For example, the hex address 0x1029384754657687 will be sent as hex: 0001 0000 0010 1001 0011 1000 0100 0111 ... Byte 1 Byte 2 Byte 3 Byte 4.
Standard Data Type Definitions
SNMP Sample Output This sample output from the Simple Network Management Protocol (SNMP) covers the first three groups of the 10892.mib. Values are shown for each object identifier (OID) in the management information base (MIB) Version Group, the Systems Management Software Group, the System State Group, the Chassis Information Table, and Event Log Table. The data is from a Dell™ PowerEdge™ 2650 server. Walk .1.3.6.1.4.1.674.10892 (Agent: 'SERVER01', Community: 'public') .iso.org.dod.internet.private.
1.3.6.1.4.1.674.10892.1.200.10.1.1.1 = 1 1.3.6.1.4.1.674.10892.1.200.10.1.2.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.3.1 = 2 1.3.6.1.4.1.674.10892.1.200.10.1.4.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.5.1 = '\02' 1.3.6.1.4.1.674.10892.1.200.10.1.6.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.7.1 = '\03' 1.3.6.1.4.1.674.10892.1.200.10.1.8.1 = '\02\02' 1.3.6.1.4.1.674.10892.1.200.10.1.9.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.10.1 = '\03\03' 1.3.6.1.4.1.674.10892.1.200.10.1.11.
1.3.6.1.4.1.674.10892.1.300.10.1.1.1 = 1 1.3.6.1.4.1.674.10892.1.300.10.1.2.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.3.1 = 2 1.3.6.1.4.1.674.10892.1.300.10.1.4.1 = 3 1.3.6.1.4.1.674.10892.1.300.10.1.5.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.6.1 = 23 1.3.6.1.4.1.674.10892.1.300.10.1.7.1 = 'Main System Chassis' 1.3.6.1.4.1.674.10892.1.300.10.1.8.1 = 'Dell Inc.' 1.3.6.1.4.1.674.10892.1.300.10.1.9.1 = 'PowerEdge 2650' 1.3.6.1.4.1.674.10892.1.300.10.1.10.1 = 'ASSETTAG' 1.3.6.1.4.1.674.
1.3.6.1.4.1.674.10892.1.300.10.1.30.1 = 1 1.3.6.1.4.1.674.10892.1.300.10.1.31.1 = 15 1.3.6.1.4.1.674.10892.1.300.10.1.32.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.33.1 = 27 1.3.6.1.4.1.674.10892.1.300.10.1.34.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.35.1 = 1 1.3.6.1.4.1.674.10892.1.300.10.1.36.1 = 480 1.3.6.1.4.1.674.10892.1.300.10.1.37.1 = 1 1.3.6.1.4.1.674.10892.1.300.10.1.38.1 = 2 1.3.6.1.4.1.674.10892.1.300.10.1.39.1 = 2 1.3.6.1.4.1.674.10892.1.300.10.1.44.1 = 0 1.3.6.1.
Glossary The following list defines or identifies technical terms, abbreviations, and acronyms used in Dell™ user documents. A ASCII Abbreviation for ampere(s). Acronym for American Standard Code for Information Interchange. A text file containing only characters from the ASCII character set (usually created with a text editor, such as Notepad in Microsoft® Windows®), is called an ASCII file. AC Abbreviation for alternating current.
backup BMC A copy of a program or data file. As a precaution, you should back up your computer’s hard drive on a regular basis. Before making a change to the configuration of your computer, you should back up important start-up files from your operating system. Abbreviation for baseboard management controller, which is a controller that provides the intelligence in the IPMI structure. baud rate A measurement of data transmission speed.
C CIM Abbreviation for Celsius. Acronym for Common Information Model, which is a model for describing management information from the DMTF. CIM is implementation independent, allowing different management applications to collect the required data from a variety of sources. CIM includes schemas for systems, networks, applications and devices, and new schemas will be added. It provides mapping techniques for interchange of CIM data with MIB data from SNMP agents and MIF data from DMI-compliant systems.
config.sys file CRC The config.sys file is executed when you boot your computer (before running any commands in the autoexec.bat file). This start-up file contains commands that specify which devices to install and which drivers to use. This file also contains commands that determine how the operating system uses memory and controls files. Abbreviation for cyclic redundancy code, which is a number derived from, and stored or transmitted with, a block of data in order to detect corruption.
DIN DMTF Acronym for Deutsche Industrie Norm which is the standards-setting organization for Germany. Abbreviation for Distributed Management Task Force, a consortium of companies representing hardware and software providers, of which Dell is a member. A DIN connector is a connector that conforms to one of the many standards defined by DIN. DIN connectors are used widely in personal computers. For example, the keyboard connector for PCs is a DIN connector. dpi Abbreviation for dots per inch.
DTE EISA Abbreviation for data terminal equipment. Any device, such as a computer system, that can send data in digital form by means of a cable or communications line. The DTE is connected to the cable or communications line through a data communications equipment (DCE) device, such as a modem. Acronym for Extended Industry-Standard Architecture, a 32-bit expansion-bus design. The expansion-card connectors in an EISA computer are also compatible with 8- or 16-bit ISA expansion cards.
ESD FCC Abbreviation for electrostatic discharge. Abbreviation for Federal Communications Commission. ESM FEPROM Abbreviation for Embedded Systems Management. Acronym for Flash Erasable Programmable Read-Only Memory. Flash memory is a kind of non-volatile storage device similar to EEPROM, but the erasing is done only in blocks or the entire chip. expanded memory A technique for accessing RAM above 1 MB. To enable expanded memory on your computer, you must use an EMM.
G HIP Abbreviation for gravities. Abbreviation for Hardware Instrumentation Package (HIP). GB Abbreviation for gigabyte(s). A gigabyte equals 1,024 megabytes or 1,073,741,824 bytes. graphics coprocessor See coprocessor. HMA Abbreviation for high memory area. The first 64 KB of extended memory above 1 MB. A memory manager that conforms to the XMS can make the HMA a direct extension of conventional memory. See also upper memory area and XMM.
I/O IPX Abbreviation for input/output. The keyboard is an input device, and a printer is an output device. In general, I/O activity can be differentiated from computational activity. For example, when a program sends a document to the printer, it is engaging in output activity; when the program sorts a list of terms, it is engaging in computational activity. Acronym for internetwork packet exchange. ID Abbreviation for identification. IRQ Abbreviation for interrupt request.
key combination LPTn A command requiring you to press multiple keys at the same time. For example, you can reboot your computer by pressing the key combination. The device names for the first through third parallel printer ports on your computer are LPT1, LPT2, and LPT3. kg LRA Abbreviation for kilogram(s), 1,000 grams. Acronym for local response agent. kHz m Abbreviation for kilohertz, 1,000 hertz. Abbreviation for meter(s). LAN mA Acronym for local area network.
memory MIF A computer can contain several different forms of memory, such as RAM, ROM, and video memory. Frequently, the word memory is used as a synonym for RAM; for example, an unqualified statement such as "a computer with 16 MB of memory" refers to a computer with 16 MB of RAM. Acronym for management information format. A MIF file contains information, status, and links to component instrumentation. MIF files are installed into the MIF database by the DMI service layer.
multifrequency monitor NTFS A monitor that supports several video standards. A multifrequency monitor can adjust to the frequency range of the signal from a variety of video adapters. Abbreviation for the NT File System option in the Windows NT operating system. NuBus mV Abbreviation for millivolt(s). Proprietary expansion bus used on Apple Macintosh personal computers.
PC 98 PGA The third PC 9x specification, which defines five categories (Consumer, Office, Mobile, Entertainment and Workstation). It eliminates the ISA bus and pushes the minimum requirements to a 200MHz CPU with 32MB of RAM and 256K of L2 cache. PC 98 machines must support OnNow, and the BIOS must support booting from a CD and be Y2K compliant. Systems cannot ship with ISA cards installed, but may have an ISA bus for legacy devices.
PME provider Abbreviation for Power Management Event. A PME is a pin on a peripheral component interconnect that allows a PCI device to assert a wake event. A provider is an extension of a CIM schema that communicates with managed objects and accesses data and event notifications from a variety of sources. Providers forward this information to the CIM Object Manager for integration and interpretation. POST Acronym for power-on self-test.
RDRAM RGB Acronym for Rambus DRAM. A dynamic RAM chip technology from Rambus, Inc. Direct RDRAMs are used in computers. Direct RDRAM chips are housed in RIMM modules, which are similar to DIMMs but have different pin settings. The chips can be built with dual channels, doubling the transfer rate to 3.2 GB/sec. Abbreviation for red/green/blue. RIMM Acronym for Rambus In-line Memory Module, which is the Rambus equivalent of a DIMM module.
SDMS SIMM Abbreviation for SCSI device management system. Acronym for single in-line memory module. A small circuit board containing DRAM chips that connects to the system board. sec Abbreviation for second(s). SIP SEC Abbreviation for single-edge contact. serial port Acronym for single in-line package, which is a type of housing for electronic components in which the connecting pins protrude from one side. A SIP is also called a Single In-line Pin Package (SIPP).
SOJ syntax Acronym for small outline package J-lead, a small-dimension, plastic, rectangular surface mount chip package with j-shaped pins on its two long sides. The rules that dictate how you must type a command or instruction so that the computer understands it. A variable’s syntax indicates its data type. SRAM system board Abbreviation for static random-access memory. Because SRAM chips do not require continual refreshing, they are substantially faster than DRAM chips.
system.ini file threshold values A start-up file for the Windows operating system. When you start Windows, it consults the system.ini file to determine a variety of options for the Windows operating environment. Among other things, the system.ini file records which video, mouse, and keyboard drivers are installed for Windows. Systems are normally equipped with various sensors that monitor temperature, voltage, current, and fan speed.
TSOP utility Acronym for thin small outline package. A very-thin, plastic, rectangular surface mount chip package with gull-wing pins on its two short sides. TSOPs are about a third as thick as SOJ chips. A program used to manage system resources—memory, disk drives, or printers, for example. UTP Abbreviation for unshielded twisted pair. UART Acronym for universal asynchronous receiver transmitter, the electronic circuit that makes up the serial port. UUID UDP V Acronym for user datagram protocol.
VGA video memory Abbreviation for video graphics array. VGA and SVGA are video standards for video adapters with greater resolution and color display capabilities than previous standards. To display a program at a specific resolution, you must install the appropriate video drivers and your monitor must support the resolution.
VLSI win.ini file Abbreviation for very-large-scale integration. A start-up file for the Windows operating system. When you start Windows, it consults the win.ini file to determine a variety of options for the Windows operating environment. Among other things, the win.ini file records what printer(s) and fonts are installed for Windows. The win.ini file also usually includes sections that contain optional settings for Windows application programs that are installed on the hard drive.
XMS Abbreviation for eXtended Memory Specification. ZIF Acronym for zero insertion force. Some computers use ZIF sockets and connectors to allow devices such as the microprocessor chip to be installed or removed with no stress applied to the device. ZIP A 3.5 inch removable disk drive from Iomega. Originally, it provided a 100 MB removable cartridges. The drive is bundled with software that can catalog the disks and lock the files for security.
Index Numerics 2067, 607 2106, 612 1403, 587 2070, 607 2107, 612 1404, 587 2076, 607 2108, 612 1602, 591 2077, 608 2109, 613 1603, 591 2079, 608 2110, 613 1604, 591 2080, 608 2111, 613 1651, 592 2081, 608 2112, 614 1652, 592 2082, 608 2114, 614 1653, 592 2083, 608 2115, 614 2048, 604 2085, 609 2116, 614 2049, 604 2086, 609 2117, 614 2050, 605 2088, 609 2118, 615 2051, 605 2089, 609 2120, 615 2052, 605 2090, 609 2121, 615 2053, 605 2091, 609 2122, 615 2054, 605 2
Index 2137, 618 2167, 623 2207, 629 2138, 618 2168, 623 2211, 629 2139, 618 2169, 624 2232, 630 2140, 619 2170, 624 2233, 630 2141, 619 2171, 624 2234, 630 2142, 619 2172, 624 2235, 630 2143, 619 2174, 624 2238, 630 2144, 619 2175, 624 2239, 630 2145, 619 2176, 625 2240, 630 2146, 619 2177, 625 2241, 630 2147, 619 2178, 625 2242, 630 2148, 619 2179, 625 2243, 630 2149, 620 2180, 625 2244, 631 2150, 620 2181, 626 2245, 631 2151, 620 2182, 626 2246, 631 2152,
2267, 633 2298, 639 2329, 647 2268, 634 2299, 640 2330, 648 2269, 634 2300, 640 2331, 648 2270, 635 2301, 640 2332, 648 2271, 635 2302, 640 2333, 648 2272, 635 2303, 641 2334, 649 2273, 635 2304, 641 2335, 649 2274, 635 2305, 641 2336, 650 2276, 635 2306, 641 2337, 650 2277, 635 2307, 642 2338, 650 2278, 636 2309, 642 2339, 650 2279, 636 2310, 642 2340, 651 2280, 636 2311, 643 2341, 651 2281, 636 2312, 643 2342, 651 2282, 636 2313, 643 2343, 651 2283, 637 2314,
Index 2359, 655 Array disk degraded, 605 2360, 655 Array disk initialize completed, 609 Bad block medium error, 619 Array disk initialize failed, 608 Bad block replacement error, 619 Array disk inserted, 605 Bad block sense error, 619 Array disk offline, 605 Bad block table is full, 642 Array disk online, 621 2361, 655 2362, 655 2363, 656 2364, 656 2365, 656 Bad block extended sense error, 620 2367, 656 Array disk rebuild completed, 609 Bad disk block could not be reassigned during a w
Chassis Information Group tables, 55 Chassis Information Table, 55 Event Log Table, 71 Firmware Table, 79 Intrusion Table, 82, 85 POST Log Table, 69 System BIOS Table, 73 UUID Table, 67 Variable Values, 89 Cluster Group, 437 Cluster Table, 437 variable values, 440 Communication regained, 622 Communication timeout, 618 Communication with the enclosure has been lost, 638 Controller alarm disabled, 619 Controller alarm enabled, 619 Controller alarm has been tested, 620 Controller battery charge level is below
Index Device returned to normal, 615 Diagnostic message, 645 Driver version mismatch, 617 G Global Data Group, 464 Global hot spare assigned, 610 Global hot spare unassigned, 610 E Enclosure alarm disabled, 618 Local Response Agent Group tables, 345 Logical Devices Group, 545 M Maximum temperature probe warning threshold value changed, 620 Enclosure alarm enabled, 618 H Enclosure firmware mismatch, 615 Hot spare SMART polling failed, 636 Memory device correction rate crossed a warning thresho
N Non-RAID SCSI driver version older than minimum required level, 623 Power Group Amperage Probe Table, 138 Power Supply Table, 129 Power Unit Table, 127 variable values, 149 Voltage Probe Table, 133 Power Group tables, 127 O Predictive Failure reported, 609 Operating System Group, 564 Memory Table, 103 Operating System Table, 101 Problems with the battery or the battery charger, 645 Operating System Memory Table, 103 Processor Device Status Traps, 591 P Patrol Read found an uncorrectable media erro
Index Slot Group System Slot Table, 277 variable values, 281 Smart configuration change, 612 Smart FPT exceeded, 612 Smart warning, 612 Smart warning degraded, 613 Smart warning temperature, 613 SNMP introduction to, 25 SNMP MIB OIDs, 26 SNMP security, 27 SNMP traps, 28 SNMP basic terminology fields, 20-21 managed object, 19 MIB, 19 SNMP, 18 variable, 20 SNMP support, configuring, 602 SNMP tables, 21 example, 22 reference guide content, 23 SNMP traps, 603 Storage Management Event Group, 556 Storage Ma
U Unrecoverable disk media error during the rebuild, 653 User Security Table, 173, 175 Virtual disk format started, 606 Virtual disk initialization, 618 Virtual disk initialization cancelled, 607 Virtual disk initialization completed, 609 V variable names capability, 21 settings, 21 state, 21 status, 21 Virtual disk initialization failed, 608 Virtual disk initialization failed.
Index 700 Index