title.fm Page 1 Friday, July 16, 2010 3:56 PM Dell OpenManage Server Administrator Version 6.
title.fm Page 2 Friday, July 16, 2010 3:56 PM Notes and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. ____________________ Information in this publication is subject to change without notice. © 2010 Dell Inc. All rights reserved. Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.
Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . What's New in Version 6.3 . . . . . . . . . . . . . . . Using CLI Commands from Windows Command Prompts . . . . . . . . . . . . . . . . . . . . . Primary CLI Commands 16 . . . . . . . . . . . . . . . . . 16 . . . . . . . . 18 . . . . . . . . . . . . . . . . 18 . . . . . . . . . . . . . . . . . 19 Success Messages . . . . . . . . . 20 . . . . . . . . . . . . . .
omreport about . . . . . . . . . . . . . . . . . . . . . omreport chassis/omreport mainsystem Commands . . 37 . . . . . 37 omreport chassis acswitch/omreport mainsystem acswitch . . . . . . . . . . . . . . . 38 omreport chassis batteries/omreport mainsystem batteries . . . . . . . . . . . . . . . . 39 omreport chassis/ omreport mainsystem omreport chassis bios/omreport mainsystem bios . . . . . . . . . . . . . . . . . . . . . . . . .
omreport chassis processors/omreport mainsystem processors . . . . . . . . . . . . . . omreport chassis pwrmanagement/omreport mainsystem pwrmanagement . . . . . . . . . . . 55 . . . . 56 . . . . . 58 omreport chassis pwrmonitoring/omreport mainsystem pwrmonitoring . . . . . . . . omreport chassis pwrsupplies/omreport mainsystem pwrsupplies . . . . . . . . . 51 omreport chassis remoteaccess/omreport mainsystem remoteaccess . . . . . . . . . . . . .
omreport system summary/omreport servermodule summary . . . . . . . . . . . . . . omreport system thrmshutdown/omreport servermodule thrmshutdown . . . . . . . . . . . . omreport system version/omreport servermodule version . . . . . . . . . . . . . . . . . . . . . . omreport preferences Commands . 4 76 . . . . . . . . . . . 77 . . . . . 79 . . . . . . . . . 80 . . . . . . . . . . . . . 80 Conventions for Parameter Tables Help With the omconfig Command omconfig about 76 .
omconfig chassis pwrmonitoring/omconfig mainsystem pwrmonitoring . . . . . . . . . . . . 112 omconfig chassis remoteaccess/omconfig mainsystem remoteaccess . . . . . . . . . . . . . 114 omconfig chassis temps/omconfig mainsystem temps . . . . . . . . . . . . . . . . . . . . . . . . 126 omconfig chassis volts/omconfig mainsystem volts . . . . . . . . . . . . . . . . . . . . . . . . 127 . . . . . . . . . . . . . . . . . . 129 omconfig preferences omconfig preferences cdvformat . . . . . . . .
5 omconfig system or servermodule assetinfo: Editing Cost of Ownership Values . . . . . . . . . . . . . . . . . . . . . . . . Overview . . . . . . . . . . . . . . . . . . . . . . . . . User Level Required for Adding Asset Information . . . . . . . . . . . . . . Adding Acquisition Information . Adding Depreciation Information . . . . . . . . . . . . 152 . . . . 153 . . . . . . . . . . . . 154 Adding Extended Warranty Information . . . 155 . . . . . . . .
Example Command for Adding Service Information . . . . . . . . . . . . . . . Adding Support Information . . . . . . . 163 . . . . . . . . . . . . . . 164 Example Command for Adding Support Information . . . . . . . . . . . . . . . Adding System Information . . . . . . 165 . . . . . . . . . . . . . . . 166 Example Command for Adding System Information . . . . . . . . . . . . . . . Adding Warranty Information . . . . . . 166 . . . . . . . . . . . . . .
omreport Fan Status . . . . . . . . . . . . . . . . omreport Power Supply Status . omreport EMM Status 180 . . . . . . . . . . . . . . . 181 omreport Enclosure Slot Occupancy Report . omreport Physical Disk Status 183 184 . . . . . . . . . . . . . . 184 . . . . . . omconfig Global Disable Smart Thermal Shutdown . . . . . . . . . . . . . . . . . omconfig Global Rescan Controller 185 . . . . . 185 . . . . . . . . 186 omconfig Set Hot Spare Protection Policy . . . . .
omconfig Stop Patrol Read . . . . . . . . . . . . omconfig Change Controller Properties omconfig Storage Virtual Disk omconfig Storage Controller 206 . . . . . . . . . . . 206 . . . . . . . . . . . . 207 . . . . . . . . . . . 208 . . . . . . . . . . . . 209 omconfig Virtual Disk Commands omconfig Blink Virtual Disk 205 . . . . . . omconfig Unblink Virtual Disk . . . . . . . . . . . omconfig Initialize Virtual Disk . . . . . . . . . . . omconfig Cancel Initialize Virtual Disk .
omconfig Offline Physical Disk . . . . . . . . . . . 227 omconfig Offline Physical Disk . . . . . . . . . . . 227 omconfig Online Physical Disk . . . . . . . . . . . 228 omconfig Assign Global Hot Spare . . . . . . . . . omconfig Unassign Global Hot Spare omconfig Rebuild Physical Disk . . . . . . . 230 . . . . . . . . . . 231 omconfig Cancel Rebuild Physical Disk . . . . . . 232 . . . . . . . . 232 . . . . . . . . . . .
7 Working With CLI Command Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251 Controlling Command Output Display . . . . . . . 251 . . . . . . . . . 252 Writing Command Output to a File Selecting a Format for Your CLI Command Output . . . . . . . . . . . . . . . . . . . Index 251 Output Options for Command Results 254 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents
1 Introduction You can perform essential systems management tasks using Dell OpenManage Server Administrator’s graphical user interface (GUI) or the command line interface (CLI). The reporting and viewing features allow retrieval of overall health status for systems on your network. At the component level, you can view information about voltages, temperatures, fan’s revolutions per minute (RPM), memory functioning, and many other critical component details.
NOTE: For information on terms used in this document, see the Glossary on the Dell support website. What's New in Version 6.3 Following are the new features of OpenManage Server Administrator 6.
• omconfig • omhelp • omreport The omconfig command writes values that you assign to an object's properties. You can specify values for warning thresholds on components or prescribe what action your system is to take when a certain warning or failure event occurs. You can also use the omconfig command to assign specific values to your system's asset information parameters, such as the purchase price of the system, the system's asset tag, or the system's location.
NOTE: omupdate commands are no longer supported in Server Administrator and are replaced by Dell Update Package or Server Update Utility commands. To update the different components, download the Dell Update Package and run /s [/f]. See the Dell Update Packages for Microsoft Windows Operating Systems User’s Guide, the Dell Update Packages for Linux User’s Guide, or the Server Update Utility User’s Guide on the Dell Support website at support.dell.
omconfig system assetinfo info=depreciation duration=6 Message: Asset information set successfully. Failure Messages CLI failure messages provide reasons why some commands do not succeed. Some common reasons why commands fail include syntax errors and components that are not present. Many error messages provide syntax information that you can use to execute the command successfully.
Message: Voltage probe warning threshold(s) set successfully. Scripting and Comparing With the CLI The Server Administrator CLI allows administrators to write batch programs or scripts to be executed by the operating system.
system usage. Command results can be routed to a file for later analysis. Reports can help administrators gain information that can be used to adjust usage patterns, to justify purchasing new system resources, or to focus on the health of a problem component. Command Syntax Overview Commands vary in complexity. The simplest command has only command level 1. The omhelp command is a simple command. When you type omhelp, a list of the main CLI commands is displayed.
omconfig system assetinfo info=acquisition purchasecost= waybill= installdate= purchasedate= ponum= signauth= expensed= costcenter= In each section, command syntax and other information about commands is formatted with any of the following fields that apply: command level 1 22 command level 2 Introduction command level 3 name=value pair 1 name=value pair 2
Using the omhelp Command 2 The omhelp command and its equivalent, -?, accesses the CLI's detailed help text interface. You can get help at several levels of detail. Each fully qualified CLI command may have a variable number of distinct parts: the command (command level 1), one or more subcommands (command level 2 and command level 3, if present), and one or more name= value pair(s). By appending -? (space-dash-question mark) to any command, you can get help for that command.
• shutdown • thrmshutdown • webserver Figure 2-1 shows the levels of help for a command. Figure 2-1. Different Levels of Help for a Command You can also parse the omconfig system assetinfo command as follows: [name=value pair 2] where command levels 1, 2, and 3 are represented by omconfig system assetinfo, name=value pair 1 is represented by info=depreciation, and name=value pair 2 is represented by method=straightline.
For one info value, specify one or more optional parameter(s). Table 2-1 displays the optional parameters for info=acquisition: Table 2-1.
Using the omhelp Command
3 omreport: Viewing System Status Using the Instrumentation Service The omreport command allows you to see detailed information about your system components. You can retrieve summaries for many system components at one time, or you can get details about a specific component. This chapter shows you how to get reports with the level of detail that you want. Commands documented in this chapter vary in whether they define the fields that appear in the results of a particular omreport command.
Conventions for Parameter Tables When listing the parameters that a command can take, the parameters are listed in alphabetical order instead of the order in which they appear in the command line interface. The symbol |, often called pipe, is the logical exclusive or operator. For example, enable | disable means that you can enable or disable the component or feature, but you cannot simultaneously enable and disable the component or feature.
Table 3-2. Command Level 1, Level 2, and Level 3 for omreport Command Command Level 2 Level 1 Command Level 3 Use User Privilege Required omreport modularenclosure U, P, A Shows information for all the modular chassis. about U, P, A Shows version number and properties for Server Administrator. U, P, A Displays information for all the Server Administrator programs installed. U, P, A Shows the general status of all the main components.
Table 3-2. Command Level 1, Level 2, and Level 3 for omreport (continued) Command Command Level 2 Level 1 30 Command Level 3 Use User Privilege Required fans U, P, A Shows the status and thresholds for system fans. firmware U, P, A Shows the name and version of the firmware. frontpanel U, P, A Shows whether the front panel button settings, such as the Power button and/or Nonmasking Interrupt (NMI) button (if present on the system), are enabled or disabled.
Table 3-2. Command Level 1, Level 2, and Level 3 for omreport (continued) Command Command Level 2 Level 1 Command Level 3 Use User Privilege Required leds U, P, A Shows the properties you have set for light-emitting diodes to flash under various alert conditions. memory U, P, A Shows properties of your system's memory arrays.
Table 3-2. Command Level 1, Level 2, and Level 3 for omreport (continued) Command Command Level 2 Level 1 Command Level 3 Use User Privilege Required remoteaccess U, P, A Shows general information on remote access. slots U, P, A Shows properties of your system’s expansion slots and other slot types. temps U, P, A Shows the status and thresholds for the system temperature sensors. volts U, P, A Shows the status and thresholds for the system voltage sensors.
Table 3-2. Command Level 1, Level 2, and Level 3 for omreport (continued) Command Command Level 2 Level 1 Command Level 3 Use User Privilege Required alertlog U, P, A Allows the administrator to display the alert log. assetinfo U, P, A Shows the cost of ownership information for your system. cmdlog U, P, A Allows the administrator to display the command log. esmlog U, P, A Allows the administrator to display the hardware log.
Table 3-2. Command Level 1, Level 2, and Level 3 for omreport (continued) Command Command Level 2 Level 1 preferences 34 Command Level 3 Use User Privilege Required recovery P, A Shows how your system is configured to respond to a hung operating system. shutdown P, A Shows how the shutdown action is to be performed. summary U, P, A Shows the key facts for all system components, including main system chassis, software, and storage.
Help With the omreport Command Use the omreport -? command to get a list of the available commands for omreport. Use omreport -? to get help on the level 2 about, chassis, and system commands. The following information on omreport system -? also applies to get help for the omreport chassis command. To see a list of valid commands for omreport system, type: omreport system -? | more omreport modularenclosure Use the omreport modularenclosure command to view details of the modular system.
Attribute : Description Value : The system component provides a complete set of remote management functions for Dell systems. Attribute : Version Value : 1.0 (100) Attribute : IP Address Value : 101.102.103.
Server Administrator includes a number of services, each of which has a version number of its own. The Contains field reports version numbers for the services as well as other useful details. The output below is an example, and can change depending on your system’s configuration and the version of Server Administrator installed on your system: Contains: Instrumentation Service 6.x.x Storage Management Service 2.x.x Sun JRE - OEM Installed Version 1.x.x Secure Port Server 3.x.x Core Service 1.x.
Server Administrator displays a general status for your main system chassis/main system components. SEVERITY Ok Critical Ok Ok Ok Ok : COMPONENT : Fans : Intrusion : Memory : Power Supplies : Temperatures : Voltages omreport chassis acswitch/omreport mainsystem acswitch Use the omreport chassis acswitch or omreport mainsystem acswitch command if your system has redundant AC power lines that are configured in a failover arrangement.
Location AC Present Active Source : AC Power Line 2 : Power Present : Not Active Server Administrator reports values for the Redundancy Status and Redundancy Mode fields. omreport chassis batteries/omreport mainsystem batteries Use the omreport chassis batteries or omreport mainsystem batteries command to view battery properties. Type: omreport chassis batteries or omreport mainsystem batteries Server Administrator displays the summary of the battery information for your system.
NOTE: All the BIOS Setup parameters are not displayed. Only those BIOS setup properties configured during system boot are displayed. Table 3-3. BIOS Setup Parameters Parameters Description Attribute Bootsequence Displays the device used to boot the system. Numlock Displays whether the keypad can be used as number keys. Embedded Video Controller Displays whether the Embedded Video Controller option is enabled or disabled.
Table 3-3. BIOS Setup Parameters (continued) Parameters Description NIC 1 Displays whether the first NIC is enabled (with or without PXE/iSCSI) or disabled during system boot. NIC 2 Displays whether the second NIC is enabled (with or without PXE/iSCSI) or disabled during system boot. NIC 3 Displays whether the third NIC is enabled (with or without PXE/iSCSI) or disabled during system boot. NIC 4 Displays whether the fourth NIC is enabled (with or without PXE/iSCSI) or disabled during system boot.
Table 3-3. BIOS Setup Parameters (continued) Parameters Description IDE Primary Drive 0 Displays whether the device is automatically detected and enabled or if the device is disabled. IDE Primary Drive 1 Displays whether the device is automatically detected and enabled or if the device is disabled. Intrusion Displays whether the intrusion check is enabled or disabled during system boot. Mouse Displays whether the mouse is enabled or disabled.
Table 3-3. BIOS Setup Parameters (continued) Parameters Description Console Redirection After Boot Displays whether console redirection after system reboot is enabled or disabled. External Serial Connector Displays whether the external serial connector is mapped to Serial Device 1, Serial Device 2, or a Remote Access Device. Console Redirection Failsafe Baud Rate Displays the setting for console redirection failsafe baud rate. Serial Address Select Displays port address for the serial devices.
Internal Dual SD Module Redundancy : Critical Attribute : Redundancy Value : Lost Internal SD Modules Status Status : OK Connector Name : System Board SD Status 1 State : Present Storage Size : 512 MB Status : OK Connector Name : System Board SD Status 2 State : Present Storage Size : 512 MB VFlash Media Details Connector Name : System Board SD Status 1 Type : vFlash SD Card State : Present Available Size : 472 MB Storage Size : 512 MB omreport chassis fans/omreport mainsystem
The index parameter is optional. If you do not specify the index, Server Administrator displays a summary of status, readings, and thresholds set for any fan probes that might be present on your system. If you specify the index, Server Administrator displays a summary for a specific fan probe. omreport chassis firmware/omreport mainsystem firmware Use the omreport chassis firmware or omreport mainsystem firmware command to view current firmware properties.
omreport chassis fru or omreport mainsystem fru Server Administrator displays a summary of your system’s FRU information. This information is available in the Server Administrator GUI, SNMP, and Common Information Model and is primarily used to support troubleshooting activities. omreport chassis hwperformance/omreport mainsystem hwperformance Use the omreport chassis hwperformance or omreport mainsystem hwperformance command to view the status and cause for the system’s performance degradation.
omreport chassis info index=n or omreport mainsystem info index=n The index parameter specifies a chassis number and is optional. If you do not specify the index, Server Administrator displays summary chassis information for each chassis. If you specify the index, Server Administrator displays summary information for a specific chassis.
omreport chassis intrusion A message that resembles the following displays: Status : Ok Probe Name : Main chassis intrusion State : Chassis is closed omreport chassis leds/omreport mainsystem leds Use the omreport chassis leds or omreport mainsystem leds command to find out whether clear hard drive fault is supported and what severity level lights up the LED. Type: omreport chassis leds index=n or omreport mainsystem leds index=n The index parameter is optional.
The index parameter is optional. If you do not specify the index, Server Administrator displays information for all memory modules on your system. If you specify the index, Server Administrator displays a summary for a specific memory module. Output for an occupied memory slot may resemble the following: Index Status Connector Name Type Size : : : : : 1 OK DIMM_B SDRAM-SYNCHRONOUS 256 MB An unoccupied memory slot still has a connector name.
omreport chassis nics/omreport mainsystem nics Use the omreport chassis nics or omreport mainsystem nics command to view NIC and Team interface details. To view NIC properties, type: omreport chassis nics index=n or omreport mainsystem nics index=n The index parameter is optional.
omreport chassis ports/omreport mainsystem ports Use the omreport chassis ports or omreport mainsystem ports command to view properties of your system’s parallel and serial ports. Values display for the following fields: Port Type, External Name, Base I/O Address, IRQ Level, Connector Type, and Maximum Speed. Port Type is the detailed type of each system port, from the more general serial, parallel, and USB ports to the names of ports by device type connected to it, for example, pointing device or keyboard.
Connector Name is the name or number of the device that occupies the processor slot in the system. Processor Brand is the type of processor made by a manufacturer such as Intel Itanium, Intel Pentium III, Intel Xeon, or AMD Opteron. Processor Version is the model and stepping number of the processor. Current Speed is the actual processor speed in MegaHertz at system boot time. State is whether the processor slot is enabled or disabled. Core Count is the number of processors integrated into one chip.
The following fields are defined for a cache present on a particular microprocessor. If the cache is internal to the processor, the fields do not appear in the cache report: • Speed • Cache Device Supported Type • Cache Device Current Type • External Socket Name NOTE: Due to the limitations of certain operating systems (for example, VMware ESXi), certain features may not be available with this release of OpenManage Server Administrator.
A Write Policy describes how the cache deals with a write cycle. In a write-back policy, the cache acts like a buffer. When the processor starts a write cycle, the cache receives the data and stops the cycle. The cache then writes the data back to the main memory when the system bus is available. In a write-through policy, the processor writes through the cache to the main memory. The write cycle does not complete until the data is stored into the main memory.
omreport chassis pwrmanagement/omreport mainsystem pwrmanagement Use the omreport chassis pwrmanagement or omreport mainsystem pwrmanagement command to view the power budget cap and power management profiles of your system. The values display either in Watts or BTU/Hr based on the configuration.
omreport chassis pwrmonitoring/omreport mainsystem pwrmonitoring Use the omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring command to view the properties of your system’s power consumption. The values display either in Watts or BTU/Hr based on the configuration.
Power Consumption Information Power Consumption Index : 2 Status : Ok Probe Name : System Board Reading : System Level Warning Threshold : 539 W Failure Threshold : 994 W : 1400 W Power Headroom Name : System Instantaneous Headroom Reading : 300 W Name : System Peak Headroom Reading : 340 W Amperage Location : PS 1 Current 1 Reading : 1.2 A Location : PS 2 Current 2 Reading : 1.
Power Tracking Statistics Statistics : Energy consumption Measurement Start Time : Thu Jun 28 11:03:20 2007 Measurement Finish Time : FRI Jun 28 11:05:46 2007 Reading : 5.9 KWH Statistics : System Peak Power Measurement Start Time : Mon Jun 18 16:03:20 2007 Peak Time : Wed Jun 27 00:23:46 2007 Peak Reading : 630 W Statistics : System Peak Amperage Measured Since : Mon Jun 18 16:03:20 2007 Read Time : Tue Jun 19 04:06:32 2007 Peak Reading : 2.
• Maximum Output Wattage • Online Status • Power Monitoring Capable omreport chassis remoteaccess/omreport mainsystem remoteaccess Use the omreport chassis remoteaccess or omreport mainsystem remoteaccess command to view general information on baseboard management controller or integrated Dell remote access controller (BMC/iDRAC) and remote access controller if DRAC is installed.
omreport chassis slots/omreport mainsystem slots Use the omreport chassis slots or omreport mainsystem slots command to view properties of your system’s slots. Type: omreport chassis slots index=n or omreport mainsystem slots index=n The index parameter is optional. If you do not specify the index, Server Administrator displays properties for all of the slots in your system. If you specify the index, Server Administrator displays properties for a specific slot.
omreport chassis volts/omreport mainsystem volts Use the omreport chassis volts or omreport mainsystem volts command to view properties of your system’s voltage probes. Type: omreport chassis volts index=n or omreport mainsystem volts index=n The index parameter is optional. If you do not specify the index, Server Administrator displays a summary of status, readings, and thresholds set for any voltage probes that might be present on your system.
SEVERITY : COMPONENT Ok : Main System Chassis Critical : Storage Commands for Viewing Logs You can use the omreport system or omreport servermodule command to view logs: the alert log, the command log, and the hardware or ESM log. NOTE: If the Alert log or Command log displays invalid XML data (such as when XML data generated for the selection is not well-formed), to clear the log and resolve the issue."omconfig system alertlog action=clear" or "omconfig system cmdlog action=clear" resolves the issue.
Overall Health Status of the ESM Log When you type omreport system esmlog or omreport servermodule esmlog, the ESM log displays. The first line of the report reflects the overall health of the system hardware. For example, Health: OK means that less than 80 percent of the space allotted for the ESM log is occupied by messages.
• Fan Warning • Fan Failure • Memory Pre-failure • Memory Failure • System Power Probe Warning • System Power Probe Detects a Failure • System Peak Power • Power Supply Warning • Power Supply Failure • Degraded Redundancy • Lost Redundancy • Temperature Warning • Temperature Failure • Voltage Warning • Voltage Failure • Processor Warning • Processor Failure • Hardware Log Warning • Hardware Log Full • Watchdog Asr • Storage System Warning • Storage System Failu
• Storage Controller Battery Warning • Storage Controller Battery Failure • Removable Flash Media Present • Removable Flash Media Removed • Removable Flash Media Failure NOTE: Storage Controller Battery Warning and Storage Controller Battery Failure events are not available on modular systems. NOTE: System Power Probe Warning is not applicable to modular systems.
--------------Power Supplies ---------------Settings Enable: Informational, Warning and Critical Disable: None ----------Fans ----------Settings Enable: Critical Disable: Informational and Warning --------------------Removable Flash Media --------------------Settings Enable: Informational, Warning and Critical Disable: None The full report lists the settings for all components in your system for which events can be generated.
Table 3-6.
omreport system pedestinations/omreport servermodule pedestinations Use the omreport system pedestinations or omreport servermodule pedestinations command to view destinations where alerts for platform events are configured to be sent. Depending on the number of destinations displayed, you can configure a separate IP address for each destination address.
Table 3-7. Settings for the omreport system pedestinations/omreport servermodule pedestinations (continued) Output Attributes Description Destination Number: Destination 3 destination 3: Displays the third destination. Destination IP Address: 201.202.203.204 201:202:203:204: IP address of the third destination. Destination Number: Destination 4 destination 4: Displays the fourth destination. Destination IP Address: 210.211.212.213 210.211.212.213: IP address of the fourth destination.
omreport system shutdown/omreport servermodule shutdown Use the omreport system shutdown or omreport servermodule shutdown command to view any pending shutdown actions for your system. If properties for shutdown are configured, executing this command displays these properties. NOTE: Due to the limitations of certain operating systems (for example, VMware ESXi), certain features may not be available with this release of OpenManage Server Administrator.
Version : 6.x.x Description : Systems Management Software Contains : Instrumentation Service 6.x.x : Storage Management Service 3.x.x : Sun JRE - OEM Installed Version 3.x.x : Secure Port Server 1.x.x : Dell OpenManage Core Service 1.x.x : Instrumentation Service Integration Layer 1.x.x : Storage Management Service Integration Layer 1.x.
Slot Number : Slot 01-02 Form Factor : Half Height Dual Width Remote Access Information Remote Access Device : iDRAC6 Enterprise vFlash Media : Present vFlash Media Type : vFlash SD Card vFlash Media : 922 MB Available Size vFlash Media Size : 976 MB Processor 1 Processor Brand : Intel(R) Xeon(R) CPU Processor Version : Model 15 Stepping 6 Voltage : 1400 mV Processor 2 Processor Brand : Intel(R) Xeon(R) CPU Processor Version : Model 15 Stepping 6 Voltage : 1400 mV Memory Total Instal
Memory Available to the OS : 2048 MB Total Maximum Capacity : 32768 MB Memory Array Count : 1 Remote Access Controller Remote Access Controller Information Product : iDRAC6 Enterprise IP Address : 192.xxx.x.xxx IP Subnet : 255.xxx.x.xxx IP Gateway : 192.xxx.x.
Main System Chassis/Main System Chassis • Chassis Model • Chassis Service Tag • Chassis Lock • Chassis Asset Tag Remote Access Information • Remote Access Device • vFlash Media • vFlash Media Size Processor The following are listed for each processor in the system: • Processor Brand • Processor Family • Processor Version • Current Speed • Maximum Speed • External Clock Speed • Voltage Memory 74 • Total Installed Capacity • Memory Available to the Operating System • Tot
Memory Array The following details are listed for each memory board or module in the system (for example, the system board or the memory module in a given slot number): • Location • Use • Installed Capacity • Maximum Capacity • Slots Available • Slots Used • Ecc Type BIOS • Manufacturer • BIOS Version • Release Date Firmware • Name • Version Network Data The following details are listed for each NIC and Team interface, if Team interface is configured in the system: • IP Address
Storage Enclosures The following details are listed for each storage enclosure attached to the system: • Name • Service Tag omreport system thrmshutdown/omreport servermodule thrmshutdown Use the omreport system thrmshutdown or omreport servermodule thrmshutdown command to view the properties configured for a thermal shutdown action. The three properties that display for thermal shutdown are disabled, warning, or failure.
--------------------Main System Chassis --------------------Name Version : BIOS : 0.2.16 Name Version : BMC : 0.26 Name Version : Primary Backplane : 1.01 --------------Software --------------Name : Microsoft Windows Server 2003, Enterprise Edition Version : 5.2 Name Version : Dell Server Administrator : 6.x.x omreport preferences Commands Use the omreport preferences command to view the URL information of your Server Administrator Web server.
omreport: Viewing System Status Using the Instrumentation Service
4 omconfig: Managing Components Using the Instrumentation Service The omconfig command allows you to provide values that define warning events, configure alert actions, clear logs, and configure system shutdown, as well as allowing you to perform other systems management tasks.
Conventions for Parameter Tables When listing the parameters that a command can take, the parameters are listed in alphabetical order instead of the order in which they appear in the command line interface. The symbol |, often called pipe, is the logical exclusive or operator. For example, enable | disable means that you can enable or disable the component or feature, but you cannot simultaneously enable and disable the component or feature.
Table 4-2. omconfig Command Level 1, Level 2, and Level 3 Command Level 1 Command Level Command Level 3 2 User Privilege Required Use about U, P, A Shows version number and properties for the Server Administrator program. details=true U, P, A Displays information for all of the Server Administrator programs that are installed. cdvformat A Specifies the delimiter for separating data fields reported in custom delimited format (cdv).
Table 4-2. omconfig Command Level 1, Level 2, and Level 3 (continued) Command Level 1 Command Level Command Level 3 2 webserver User Privilege Required Use A Allows the administrator to set the encryption levels of the Web server and configure the URL launch point in the Server Administrator Web server environment.
Table 4-2. omconfig Command Level 1, Level 2, and Level 3 (continued) Command Level 1 User Privilege Required Use esmlog P, A Allows the administrator to clear the ESM log. events P, A Enables and disables SNMP traps. pedestinations P, A Sets IP addresses for alert destinations. platformevents A Determines the shutdown action, if any, to be taken for a specific platform event. Also, enables and disables platform events filter alert generation.
Table 4-2. omconfig Command Level 1, Level 2, and Level 3 (continued) Command Level 1 User Privilege Required Use biossetup A Configures the behavior of specific system components controlled by the BIOS. fans P, A Configures fan probe warning thresholds by default or by value. Command Level Command Level 3 2 chassis/ mainsystem NOTE: You cannot change threshold values on embedded server management (ESM3) and Dell PowerEdge x8xx systems.
Table 4-2. omconfig Command Level 1, Level 2, and Level 3 (continued) Command Level 1 Command Level Command Level 3 2 memorymode User Privilege Required Use A Enables or disables the spare bank and mirroring memory modes, and also specify which mode to use. pwrmanagement P, A Allows you to choose between maximum power economy and optimized performance of the system. pwrmonitoring P, A Configures power consumption information and thresholds. remoteaccess A Configures remote access information.
Table 4-2. omconfig Command Level 1, Level 2, and Level 3 (continued) Command Level 1 Command Level Command Level 3 2 User Privilege Required storage Use See "Using the Storage Management Service" on page 169. Help With the omconfig Command Use the omconfig -? command to get a list of the available commands for omconfig. Use omconfig -? to get help on the about, chassis, preferences, and system’s level 2 commands.
where | more allows you to press the spacebar to see the next screen of the CLI help output. To make a file that contains all the help for the omconfig system alertaction -? command, type: omconfig system alertaction -? -outa alert.txt where -outa directs the output of the command to a file called alert.txt. To read the help for the alertaction command on a Microsoft Windows, Red Hat Enterprise Linux, or SUSE Linux Enterprise Server operating system, type: more alert.
Hardware Application Programming Interface 5.x.x Instrumentation Service 6.x.x Instrumentation Service Integration Layer 1.x.x Intel SNMP Agent 1.xx.x OpenManage Inventory Collector 6.x.x OpenManage Tools 6.x.x Remote Access Controller 4 Data Populator 4.x.x Remote Access Controller 4 Managed Node 4.6.3 Secure Port Server 1.x.x Server Administrator Framework 6.x.x Agent for Remote Access 1.x.x Storage Management 3.x.x Sun Java Runtime Environment 1.x.
omconfig chassis/omconfig mainsystem Use the omconfig chassis or omconfig mainsystem commands to default or to set values for fan, voltage, and temperature probes, to configure BIOS behavior during system start up, to clear memory error counts, and to enable or disable power button control features where system configuration permits. Use the omconfig chassis -? or omconfig mainsystem -? command to view a list of all omconfig chassis/omconfig mainsystem commands.
Table 4-3. BIOS Setup Settings (continued) name=value pair 1 name=value pair 2 attribute= setting= Description attribute=bezel enabled: Enables the bezel removal intrusion check during system boot. setting=enabled | disabled disabled: Disables the bezel removal intrusion check during system boot.
Table 4-3. BIOS Setup Settings (continued) name=value pair 1 name=value pair 2 attribute= setting= attribute= hddorder Description sequence=aliasname1, Configures the BIOS setup hard disk aliasname2,..... sequence according to the set aliasnameN aliasnames. Changes will take effect after rebooting the system. To view the set alias names, run the command omreport chassis biossetup attribute= bootorder.
Table 4-3. BIOS Setup Settings (continued) name=value pair 1 name=value pair 2 attribute= setting= Description attribute=cstates enabled: Enables the processor to go into a deep sleep state when the system is not utilized. setting=enabled | disabled disabled: Disables the processor to go into a deep sleep state when the system is not utilized. attribute= conredirect setting=enabled | disabled enabled: Redirects the BIOS screen over Serial Port 1.
Table 4-3. BIOS Setup Settings (continued) name=value pair 1 name=value pair 2 attribute= setting= Description attribute= cpuxdsupport enabled: Enables Execute Disable (XD) support on system. setting=enabled | disabled disabled: Disables XD support on system. attribute=cpucore setting=1 | 2 | 4 | 6 | 1: Enables one core per processor. 8 | 10 | 12 |all 2: Enables two cores per processor. 4: Enables four cores per processor. 6: Enables six cores per processor. 8: Enables eight cores per processor.
Table 4-3. BIOS Setup Settings (continued) name=value pair 1 name=value pair 2 attribute= setting= Description attribute=dualnic setting=off | on | pxeboth | nic1pxe |nic2pxe | isciboth | nic1isci | nic2isci | nic1pxenic2isci | nic1iscinic2pxe | onpxeboth | onpxenone | off: Disables the Network Interface Controllers (NICs). on: Enables the network interface (PXE or iSCSI is not enabled on either of the NICs). pxeboth: Enables PXE on both NICs.
Table 4-3. BIOS Setup Settings (continued) name=value pair 1 name=value pair 2 attribute= setting= Description attribute= embvideoctrl enabled: Enables the embedded video controller to be the primary video device. setting=enabled | disabled disabled: Disables the embedded video controller to be the primary video device. attribute= esataport setting=off | auto off: Sets the embedded SATA port value to off. auto: Sets the embedded SATA port value to auto.
Table 4-3. BIOS Setup Settings (continued) name=value pair 1 name=value pair 2 attribute= setting= Description attribute=ide on: Enables this device. setting=on | off force=true off: Disables this device. force=true: Verification of setting change. attribute= idepridrv setting=off | auto attribute= intrusion setting=enabled | disabled off: Disables the device. auto: Detects and enables the device automatically. enabled: Enables the intrusion check during system boot.
Table 4-3. BIOS Setup Settings (continued) name=value pair 1 name=value pair 2 attribute= setting= Description attribute=nic1 enabled: Enables the first NIC during system boot. setting=enabled | enabledwithpxe | disabled | enabledonly | enablednonepxe | enabledwithiscsi enabledwithpxe: Enables the first NIC during system boot (with PXE on if the system has PXE) disabled: Disables the first NIC during system boot.
Table 4-3. BIOS Setup Settings (continued) name=value pair 1 name=value pair 2 attribute= setting= Description attribute=nic3 enabled: Enables the third NIC during system boot. setting=enabled | enabledwithpxe | disabled | enabledonly | enablednonepxe | enabledwithiscsi enabledwithpxe: Enables the third NIC during system boot (with PXE on if the system has PXE) disabled: Disables the third NIC during system boot.
Table 4-3. BIOS Setup Settings (continued) name=value pair 1 name=value pair 2 attribute= setting= Description attribute= numlock setting=on | off on: Uses the keypad as number keys. attribute=numa setting=enabled | disabled enabled: Enables Node Interleaving. setting=off | lpt1 | lpt2 | lpt3 off: Disables the parallel port address. attribute= ppaddress off: Uses the keypad as arrow keys. disabled: Disables Node Interleaving. lpt1: Locates the device on LPT1. lpt2: Locates the device onLPT2.
Table 4-3. BIOS Setup Settings (continued) name=value pair 1 name=value pair 2 attribute= setting= Description attribute=romb raid: Instructs the BIOS to detect RAID-on-motherboard as a RAID device. setting=raid | off | scsi force=true off: Disables the device during system boot. scsi: Instructs the BIOS to detect this device as a SCSI device. force=true: Verification of setting change.
Table 4-3. BIOS Setup Settings (continued) name=value pair 1 name=value pair 2 attribute= setting= Description attribute= secondaryscsi setting=on | off on: Enables this device. attribute= serialportaddr setting=default | alternate | com1 | com2 off: Disables this device. default: Maps to Serial device1=COM1, Serial device2=COM2. alternate: Maps to Serial device1= COM2, Serial device2=COM1 com1: Sets serial port address to COM1. com2: Sets serial port address to COM2.
Table 4-3. BIOS Setup Settings (continued) name=value pair 1 name=value pair 2 attribute= setting= Description attribute= serialport1 off: Disables serial port 1. setting=off | auto | com1 | com3 | bmcserial | bmcnic | rac | com1bmc auto: Maps serial port 1 to a COM port. com1: Maps serial port 1 to COM port 1. com3: Maps serial port 1 to COM port 3. bmcserial: Maps serial port 1 to BMC Serial. bmcnic: Maps serial port 1 to the Baseboard Management Controller (BMC) NIC.
Table 4-3. BIOS Setup Settings (continued) name=value pair 1 name=value pair 2 attribute= setting= attribute=uausb Description setting=on | backonly on: Enables the user-accessible | off USB port(s) backonly: Enables only the user accessible USB port(s) located at the back of the system. off: Disables the user-accessible USB port(s). attribute=usb setting=enabled | disabled enabled: Enables the USB port(s). disabled: Disables the USB port(s).
omconfig chassis currents/omconfig mainsystem currents NOTE: This command is no longer available through Server Administrator. omconfig chassis fans/omconfig mainsystem fans Use the omconfig chassis fans or omconfig mainsystem fans command to set fan probe warning thresholds. As with other components, you can view both warning and failure threshold values, but you cannot set failure thresholds. Your system's manufacturer sets the minimum and maximum failure thresholds.
Specifying a Value for Minimum and Maximum Warning Thresholds If you prefer to specify values for the fan probe warning thresholds, you must specify the number of the probe you are configuring and the minimum and/or maximum warning threshold values. In the following example, the probe that is being configured is probe 0.
• Ambient temperature of the system • Remote access IPv4 address • Remote access IPv6 address • Specify and configure the LCD line number • View the security state report of the LCD • Configure LCD to indicate an active remote session when the Kernelbased Virtual Machine (KVM) is available NOTE: You can configure the Power and NMI buttons only if they are present on your system. Table 4-5 shows the valid parameters for the command. Table 4-5.
Table 4-5. omconfig chassis frontpanel/omconfig mainsystem frontpanel (continued) name=value pair 1 name=value pair 2 Description config= remoteaccessmac config=ipv4idrac config=ipv6idrac config=macidrac config= ambienttemp security=modify security=view security=disabled remoteindication =true NA Sets the remote access MAC address. NA NA Sets IPv4 DRAC information. Sets IPv6 DRAC information. Sets the DRAC’s MAC address. Sets the system temperature in centigrade.
Index 0 always defaults to the main system chassis. The following command omits index=n, but accomplishes the same thing: omconfig chassis info tag=buildsys or omconfig mainsystem info tag=buildsys An acceptable command, when executed, results in the following message: Chassis info set successfully. For some chassis, you can assign a different name. You cannot rename the main system chassis.
omconfig chassis memorymode/omconfig mainsystem memorymode Use the omconfig chassis memorymode or omconfig mainsystem memorymode command to specify the redundancy mode you want to use for your system’s memory in case of memory errors. Redundant memory enables a system to switch to other available memory modules if unacceptable errors are detected in the modules that the system is currently using.
Table 4-8. omconfig chassis memorymode/omconfig mainsystem memorymode name=value pair 1 redundancy=spare | mirror | disabled | raid5 Description Spare disables the memory module that has a correctable memory event and copies the failing module’s data to a spare bank. Disabled indicates that the system is not to use other available memory modules if uncorrectable memory events are detected. Mirror switches the systems to a mirrored copy of the memory if the failing module has an uncorrectable memory event.
Table 4-9. omconfig chassis pwrmanagement/omconfig mainsystem pwrmanagement name=value pair 1 name=value pair 2 Description config=budget cap= Sets the threshold value for power budget. enable: Enables powercap settings. setting=enable | disable unit=watt | btuphr | percent config=profile disable: Disables powercap settings. watt: Configure the unit in Watts. btuphr: Configure the unit in BTU/hr. percent: Configure the unit in percentage.
Table 4-9. omconfig chassis pwrmanagement/omconfig mainsystem pwrmanagement (continued) name=value pair 1 name=value pair 2 Description cpupowermode=min | min: Sets the CPU power max | systemdbpm | consumption to minimum. osdbpm max: Sets the CPU power consumption to maximum. systemdbpm: Sets the mode to system demand based power management. osdbpm: Sets the mode to operating system demand based power management. NOTE: These options are applicable only when a custom profile is selected.
Table 4-10. omconfig chassis pwrmonitoring/omconfig mainsystem pwrmonitoring name=value pair 1 name=value pair 2 Description index= NA config=probe warnthresh= settodefault warnthresh= Number of the probe or probe index (must be specified). Sets minimum and maximum warning thresholds values to default. Sets a value for the warning threshold. watt: Displays the unit in Watts. unit=watt | btuphr | btuphr: Displays the unit in BTU/hr.
Specify a Value for Warning Thresholds If you prefer to specify values for the power consumption probe warning thresholds, you must specify the number of the probe you are configuring and the warning threshold value. You can configure the values to be displayed either in BTU/hr or Watts.
The output of the omconfig chassis remoteaccess or omconfig mainsystem remoteaccess command lists each of the available configurations. Table 4-11 shows the valid parameters: Table 4-11.
Table 4-11. omconfig chassis remoteaccess/omconfig mainsystem remoteaccess (continued) name=value pair 1 name=value pair 2 config= Description altdnsserverv6 Validates the address of the alternate DNS server for configuration. dnssourcev6=static | auto static: DNS source is set to static. config=nic (continued) encryptkey=text confirmencryptkey=text gateway=Gateway gatewayv6= enablenic=true | false auto: DNS source is set to auto. text: Text used for encryption and confirmation of encryption.
Table 4-11. omconfig chassis remoteaccess/omconfig mainsystem remoteaccess (continued) name=value pair 1 name=value pair 2 config= Description ipsource=static | dhcp | static: Static if the IP address of the systemsoftware BMC LAN interface is a fixed, assigned IP address. dhcp: DHCP if the source of the IP address of the BMC LAN interface is the dynamic host configuration protocol. systemsoftware: System software if the source of the IP address of the BMC LAN interface is from the system software.
Table 4-11. omconfig chassis remoteaccess/omconfig mainsystem remoteaccess (continued) name=value pair 1 name=value pair 2 config= Description number: Virtual LAN identification in the range of 1 to 4094. vlanpriority=number number: Priority of virtual LAN identification in the range of 0 to 7. baudrate=9600 | 19200 | 9600: Sets the connection speed to 9600 38400 | 57600 | 115200 bits per second. vlanid=number config=serial 19200: Sets the connection speed to 19200 bits per second.
Table 4-11. omconfig chassis remoteaccess/omconfig mainsystem remoteaccess (continued) name=value pair 1 name=value pair 2 config= Description config=serial (continued) directbasic: Type of messaging used for IPMI messaging over a serial connection. mode=directbasic | directterminal | directbasicterminal | modembasic | modemterminal | modembasicterminal directterminal: Type of messaging that uses printable ASCII characters and allows a limited number of text commands over a serial connection.
Table 4-11. omconfig chassis remoteaccess/omconfig mainsystem remoteaccess (continued) name=value pair 1 name=value pair 2 config= Description config= serialoverlan true: Enables serial over LAN for the BMC. enable=true | false false: Disables serial over LAN for the BMC. baudrate=9600 | 19200 | 9600: Sets the volatile and nonvolatile 38400 | 57600 | 115200 connection speed to 9600 bits per second. 19200: Sets the volatile and non-volatile connection speed to 19200 bits per second.
Table 4-11. omconfig chassis remoteaccess/omconfig mainsystem remoteaccess (continued) name=value pair 1 name=value pair 2 config= Description privilegelevel= administrator: Sets the maximum administrator | operator | privilege level that can be accepted on a user serial over LAN channel, to Administrator. operator: Sets the maximum privilege level that can be accepted on a serial over LAN channel, to Operator.
Table 4-11. omconfig chassis remoteaccess/omconfig mainsystem remoteaccess (continued) name=value pair 1 name=value pair 2 config= Description newlinesequence=none | none: BMC does not use a crlf | null | cr | lfcr | lf termination sequence. crlf: BMC uses as a new line sequence when the BMC writes a new line to the console. null: BMC uses as a new line sequence when the BMC writes a new line to the console.
Table 4-11. omconfig chassis remoteaccess/omconfig mainsystem remoteaccess (continued) name=value pair 1 name=value pair 2 config= Description id=number newpw=text number: ID (in numeric format) of the user being configured. confirmnewpw=text newpw=text: New password of the user. confirmnewpw=text: Confirm the new password. id=number: ID (in numeric format) of the user being configured.
Table 4-11. omconfig chassis remoteaccess/omconfig mainsystem remoteaccess (continued) name=value pair 1 name=value pair 2 config= id=user id dracusergroup=admin | poweruser | guest | custom | none Description id=user id: User ID of the user being configured. dracusergroup=admin: Enables the Administrator user privileges. dracusergroup=poweruser: Enables the Power User privileges. dracusergroup=guest: Enables the Guest user privileges. dracusergroup=custom: Enables the Custom User privileges.
Table 4-12. omconfig chassis remoteaccess config=user id= dracusergroup=custom/omconfig mainsystem remoteaccess config=user id= dracusergroup=custom name=value pair 1 name=value pair 2 config=user (continued) name=value pair 3 id=user id logindrac= true | dracusergroup= false custom configuredrac= true | false Description true/false: Enables/disables logging into DRAC. true/false: Enables/disables configuration of DRAC.
omconfig chassis temps/omconfig mainsystem temps Use the omconfig chassis temps or omconfig mainsystem temps command to set warning thresholds for temperature probes. As with other components, you can view both warning and failure threshold values, but you cannot set failure threshold values. Your system's manufacturer sets the minimum and maximum failure threshold values. NOTE: Threshold values that you can set vary from one system configuration to another.
Specify a Value for Minimum and Maximum Warning Thresholds If you want to specify values for the temperature probe warning thresholds, you must specify the number of the probe you are configuring and the minimum and/or maximum warning threshold value. In the following example, the probe that is being configured is probe 4: omconfig chassis temps index=4 minwarnthresh=11.2 maxwarnthresh=58.7 or omconfig mainsystem temps index=4 minwarnthresh= 11.2 maxwarnthresh=58.
Table 4-15. omconfig chassis volts/omconfig mainsystem volts (continued) name=value pair Description minwarnthresh= Sets minimum warning threshold value(3 decimal places). sets maximum warning threshold value (3 decimal places).
NOTE: Minimum and maximum warning threshold values for the voltage cannot be set on PowerEdge x8xx systems. omconfig preferences Use the omconfig preferences command to set system preferences. Use the command line to set the SNMP root password and specify the user levels able to access Server Administrator. You can also configure the Active Directory service and SNMP set operations.
Table 4-16. Active Directory Service Configuration Parameters name=value pair Description prodname= Specifies the product to which you want to apply the Active Directory configuration changes. prodname refers to the name of the product defined in omprv32.ini. For Server Administrator, it is "omsa". true: Enables Active Directory service authentication support and the Active Directory Login option on the login page.
Table 4-17. SNMP Root Password Parameters name=value pair Description setting=rootpw oldpw= newpw= confirmnewpw= Required. Enter the old SNMP root password. Sets the new SNMP root password. Confirms the new SNMP root password. When you type omconfig preferences snmp setting=rootpw, the system prompts you to supply values for the required parameters. When you type omconfig preferences snmp, you must supply all the parameters in the initial command line.
omconfig preferences useraccess Depending on the policies of your organization, you may want to restrict the access that some user levels have to Server Administrator. The omconfig preferences useraccess command allows you to grant or withhold the right of users and power users to access Server Administrator. Table 4-19 shows the valid parameters for the command. Table 4-19.
Table 4-20. Configuring Webserver Preferences name=value pair 1 name=value pair 2 Description attribute= sslencryption setting= autonegotiate: Sets the encryption levels automatically based on your web browser settings. attribute=seturl attribute= signalgorithm 128bitorhigher: Sets the encryption levels to 128-bit or higher. host= port= Enables you to configure the URL launch point in the Server Administrator Web server environment.
omconfig system/omconfig servermodule Use the omconfig system or omconfig servermodule commands to clear logs, determine how various shutdown actions occur, set initial values or edit values for cost of ownership information, and determine how to respond to a hung operating system.
The event is a power supply failure and the action is to broadcast a message to all Server Administrator users. Available Alert Actions Table 4-21 shows the alert actions for each component that allows you to configure an alert action. Table 4-21. Alert Actions You Can Set for Warning and Failure Events Alert Action Setting Description alert=true | false true: Enables your system's console alert.
Table 4-22. Events for Which You Can Set Alert Actions (continued) Event Name Description event=fanwarn event=fanfail event=hardwarelogwarn event=hardwarelogfull event=intrusion event=memprefail Sets actions when a fan probe detects a warning value. Sets actions when a fan probe detects a failure value. Sets actions when a hardware log detects a warning value. Sets actions when a hardware log is full. Sets actions when a chassis intrusion event is detected.
Table 4-22. Events for Which You Can Set Alert Actions (continued) Event Name Description event=watchdogasr Sets actions that Server Administrator performs on the next system startup after a watchdog Automatic System Recovery (ASR) is performed for a hung operating system. event= Sets actions that Server Administrator performs when the removableflashmediapresent system detects a removable flash media.
Example Current Probe Actions To disable system console alert if a current probe detects a warning event, type: omconfig system alertaction event=currentwarn alert=false or omconfig servermodule alertaction event= currentwarn alert=false To enable broadcast messages if a current probe detects a failure event, type: omconfig system alertaction event=currentfail broadcast=true or omconfig servermodule alertaction event= currentfail broadcast=true Example Fan Probe Actions To generate alerts when a fan probe
Commands for Clearing Logs NOTE: For more information about alert messages, see the Dell OpenManage Server Administrator Messages Reference Guide. You can use the omconfig system or omconfig servermodule command to clear three logs: the alert log, the command log, and the hardware or ESM log. To clear the contents of the alert log, type: omconfig system alertlog action=clear or omconfig servermodule alertlog action=clear NOTE: Entering an invalid RAC user name may prevent the command log from displaying.
Table 4-23. omconfig system pedestinations/omconfig servermodule pedestinations name=Value Pair Description destenable=true | false true: Enables an individual platform event filter destination after a valid IP address has been set. false: Disables an individual platform event filter. index=number Sets the index for the destination. ipaddress=ipv4|ipv6 Sets the IP address for the destination.
Table 4-24. Parameters for Alert Action Command (continued) Action Description action= powerreduction Reduces the processor speed until the power consumption comes down and reaches below the warning threshold. If the system power consumption stays below the warning threshold, increases the processor speed NOTE: This action is applicable only to non–modular systems.
Table 4-25. omconfig system platformevents (continued) Event Name Description event=intrusion Sets action or enables/disables alert generation when a chassis is opened. event=powerwarn Sets action or enables/disables alert generation when a power device probe detects that the power supply, voltage regulator module, or DC to DC converter is pending a failure condition. event=powerabsent Sets action or enables/disables alert generation when a processor probe detects that the power supply is absent.
Table 4-25. omconfig system platformevents (continued) Event Name Description event= removableflashmediapresent Sets actions that Server Administrator performs when the system detects a removable flash media. event= Sets actions that Server Administrator performs when a removableflashmediaremoved removable flash media is removed. event= removableflashmediafail Sets actions that Server Administrator performs when a removable flash media fails.
omconfig system events source=snmptraps or omconfig servermodule events source=snmptraps Type Type refers to the name of the component(s) involved in the event. Table 4-26 shows the valid parameters for system event types. Table 4-26.
Table 4-27. Command System Event Severity Parameters Result omconfig system events type= Enables notification severity=info for informational, or warning, and critical omconfig servermodule events events. type= severity=info omconfig system events type= Enables notification severity= for warning and warning critical events.
omconfig system events type=fan index=0 severity= critical or omconfig servermodule events type=fan index=0 severity=critical As a result of the example command, Server Administrator sends an SNMP trap only when the first fan in the system chassis (index 0) has reached critical fan RPMs. omconfig system webserver/omconfig servermodule webserver Use the omconfig system webserver or omconfig servermodule webserver command to start or stop the Web server. Table 4-28 shows the valid parameters for the command.
Table 4-29. Recovery Parameters (continued) action=poweroff Turns off electrical power to the system. action=powercycle Turns off electrical power to the system, pauses, turns the power on, and reboots the system. Power cycling is useful when you want to re-initialize system components such as hard drives. timer= Number of seconds that must pass before the operating system in a system is considered hung operating system (from 20 seconds to 480 seconds).
Table 4-30. Shutdown Parameters (continued) name=value pair Description action=poweroff action=powercycle Turns off the electrical power to the system. Turns off the electrical power to the system, pauses, turns the power on, and reboots the system. Power cycling is useful when you want to re-initialize system components such as hard drives. true: Closes the file system and exits the operating system before shutting down the system.
Table 4-31 shows the valid parameters for the command. Table 4-31. Thermal Shutdown Parameters name=value pair Description severity= disabled | warning | failure disabled: Disable thermal shutdown. An administrator must intervene. warning: Perform a shutdown when a temperature warning event is detected. A warning event occurs when any temperature probe inside a chassis reads a temperature (in degrees Celsius) that exceeds the maximum temperature warning threshold value.
omconfig: Managing Components Using the Instrumentation Service
5 omconfig system or servermodule assetinfo: Editing Cost of Ownership Values Overview The omconfig system assetinfo or omconfig servermodule assetinfo command helps you to edit a comprehensive set of parameters that make up your system's total cost of ownership. This section explains the parameters that can be reported and configured under the omconfig system assetinfo or omconfig servermodule assetinfo command.
Adding Acquisition Information Acquisition refers to the facts about a business entity's purchase or lease of a system. Use the omconfig system assetinfo info=acquisition or omconfig servermodule assetinfo info=acquisition command to add detailed information about the purchase or lease of a system. Table 5-2 shows the valid parameters for the command. Table 5-2.
Table 5-2. omconfig system assetinfo info=acquisition/omconfig servermodule assetinfo info=acquisition (continued) Command Command Level 1 Level 2 Command Name= Name= Value Pair 2 Description Level 3 Value Pair 1 purchasedate= signauth= waybill= Date the owner purchased the system. Name of the person who approved the purchase or the service call on the system. Receipt from the carrier for the goods received.
yes costcenter=finance or omconfig servermodule assetinfo info=acquisition purchasecost=5000 waybill=123456 installdate=120501 purchasedate= 050601 ponum=9999 signauth="John Smith" expensed= yes costcenter=finance The following message appears: Asset information set successfully. Adding Depreciation Information Depreciation is a set of methods for computing the devaluation of your asset over time.
Table 5-3. omconfig system assetinfo info=depreciation/omconfig servermodule assetinfo info=depreciation (continued) Command Level 1 Command Level 2 Command Name= Value Name= Value Level 3 Pair 1 Pair 2 Description percent= Portion of 100 that an asset is devalued or depreciated. unit=months Unit is months or | years years.
Table 5-4 shows the valid parameters for the command. Table 5-4. omconfig system assetinfo info=extwarranty/omconfig servermodule assetinfo info=extwarranty Command Level 1 Command Level 2 Command Level 3 Name= Value Name= Value Description Pair 1 Pair 2 omconfig system/server module assetinfo info= extwarranty cost= enddate= Cost of the extended warranty service. Date the extended warranty agreement ends.
You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1. For an example, see "Example Commands for Adding Acquisition Information" on page 153. Adding Lease Information A lease is an agreement to pay for the use of a system for a specified period of time. The lessor retains ownership of the system. Table 5-5 shows the valid parameters for the command. Table 5-5.
Example Command for Adding Lease Information To provide a value for a lease parameter, type a command of the form: omconfig system assetinfo info=lease or omconfig servermodule assetinfo info=lease . For example, type: omconfig system assetinfo info=lease value=4500 or omconfig servermodule assetinfo info=lease value= 4500 The following message appears: Asset information set successfully.
Table 5-6. omconfig system assetinfo info=maintenance/omconfig servermodule assetinfo info=maintenance (continued) Command Command Level 1 Level 2 Command Name= Value Level 3 Pair 1 Name= Value Pair 2 Description provider= Business entity providing the maintenance service. startdate= Date the maintenance begins. restrictions= Activities not covered by the maintenance contract.
Adding Outsource Information Outsourcing is the practice of contracting with another business to maintain the system in good working order. Table 5-7 shows the valid parameters for adding outsource information. Table 5-7.
Example Command for Adding Outsource Information To provide a value for an outsource parameter, type a command of the form: omconfig system assetinfo info=outsource or omconfig servermodule assetinfo info=outsource . For example, type: omconfig system assetinfo info=outsource providerfee=75 or omconfig servermodule assetinfo info=outsource providerfee=75 The following message appears: Asset information set successfully.
Table 5-8. omconfig system assetinfo info=owner/omconfig servermodule assetinfo info=owner (continued) Command Command Level 1 Level 2 Command Name= Value Name= Value Level 3 Pair 1 Pair 2 ownername = type=owned | leased | rented Description Business entity that owns the system. Whether the user of the system owns, leases, or rents the system.
Table 5-9. omconfig system assetinfo info=service/omconfig servermodule assetinfo info=service Command Level 1 Command Level Command Name= Name= Value 2 Level 3 Value Pair 1 Pair 2 Description omconfig system/server module assetinfo info= service renewed= true | false Whether the service agreement has been renewed. type= Type of service that the contract covers. vendor= Business entity that offers service on the system.
You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1. For an example, see "Example Commands for Adding Acquisition Information" on page 153. Adding Support Information Support refers to technical assistance that the system user can seek when the user seeks guidance on the proper use of a system to perform tasks.
Table 5-10. omconfig system assetinfo info=support/omconfig servermodule assetinfo info=support (continued) Command Command Level 1 Level 2 Command Name= Name= Value Pair 2 Description Level 3 Value Pair 1 outsourced=true Whether an external | false business entity provides technical support or the system owner's employees provide technical support. type=network | Whether support is storage for network attached devices or for storage devices.
Adding System Information System information includes the primary user of the system, the phone number for the primary user, and the location of the system. Table 5-11 shows the valid parameters for adding system information. Table 5-11.
You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time, as long as all the parameters for name=value pair 2 belong to the same name=value pair 1. For an example, see "Example Commands for Adding Acquisition Information" on page 153. Adding Warranty Information Use the omconfig system warranty or omconfig servermodule warranty command to assign values for warranty information.
Example Command for Adding Warranty Information To provide a value for a warranty parameter, type a command of the form: omconfig system assetinfo info=warranty or omconfig servermodule assetinfo info=warranty . For example, type: omconfig system assetinfo info=warranty unit=days or omconfig servermodule assetinfo info=warranty unit=days The following message appears: Asset information set successfully.
Using the Storage Management Service 6 The CLI of Storage Management enables you to perform all of Storage Management’s reporting, configuration, and management functions from an operating system command shell. The Storage Management CLI also enables you to script command sequences. The Storage Management CLI provides expanded options for the Dell OpenManage Server Administrator omreport and omconfig commands. This chapter only documents the omreport and omconfig commands that apply to Storage Management.
Table 6-1 describes these command levels. Table 6-1. Example Command Levels Command level 1 Command level 2 Command level 3 Use omconfig storage pdisk Specifies the command Indicates the Server Administrator service (in this case, Storage Management) that implements the command Specifies the type of object on which the command operates Following the command levels, the omreport and omconfig command syntax may require one or more name=value pairs.
Table 6-2. Syntax For Name=Value Pairs For Parameters Syntax Description controller=id Indicates the controller ID as reported by the omreport storage controller command. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=id to display the IDs for the physical disks attached to the controller. connector=id vdisk=id For example, the controller=id parameter might be specified as controller=1.
Table 6-2. Syntax For Name=Value Pairs For Parameters (continued) Syntax Description battery=id Indicates the battery ID as reported by the omreport command. To obtain this value, type omreport storage controller to display the controller IDs and then type omreport storage battery controller=id to display the ID for the controller battery. The caret symbols (< >) enclose variable elements that you must specify. <> [] | For example, the name= parameter might be specified as name=VirtualDisk1.
omreport Storage Help Table 6-3 provides the omreport storage command syntax. Table 6-3. omreport storage help Command Level 1 Command Level 2 Command Level 3 Use omreport storage pdisk vdisk controller enclosure connector battery globalinfo Displays a list of storage components for which omreport commands are available. Displays a list of the omreport storage pdisk parameters for displaying physical disk information.
omreport Controller Status Table 6-4 describes the syntax for the omreport Controller Commands. Table 6-4. omreport Controller Commands Required Command Optional name= Levels (1, 2, 3) value pairs Use omreport storage controller Displays property information for all controllers attached to the system. Displays the specified controller and all attached components such as enclosures, virtual disks, physical disks, and so on. controller=id where id is the controller number.
Table 6-5. omreport Global Information Commands Required Command Levels (1, 2, 3) Optional name= value pairs omreport storage globalinfo Use Displays whether smart thermal shutdown is enabled or disabled. See the "omconfig Global Enable Smart Thermal Shutdown" on page 185 command for more information. Displays the hot spare protection policy that you have set. See the Dell OpenManage Server Administrator Storage Management User’s Guide for more information on setting hot spare protection policy.
Table 6-7. omreport Connector Commands Required Command Levels (1, 2, 3) Optional name=value pairs omreport storage connector Use Displays all connectors present on all controllers on the system. NOTE: This command works only controller=id where id is the controller number. For example: controller=0 controller=id where id is the controller number. For example: controller=0 connector=id where id is the connector number. For example: connector=0 when the controller ID is specified.
Table 6-8. omreport Enclosure Commands (continued) Required Command Levels (1, 2, 3) Optional name=value pairs Use controller=id enclosure= Displays the specified enclosure and its components. where id is the controller number and is the enclosure ID. Example for SCSI controllers: controller=0 enclosure=2. Example for SAS controllers: controller=0 enclosure= 1:2.
omreport Temperature Probe Status Table 6-9 describes the syntax for the omreport Probe Commands Table 6-9. omreport Temperature Probe Commands Required Command Levels Optional name=value pairs (1, 2, 3) and name=value pair Use omreport storage enclosure Displays property information for all enclosures attached to the system. controller=id enclosure= Displays the temperature probes for the specified info=temps enclosure.
omreport Fan Status Table 6-10 describes the syntax for the omreport Fan Commands Table 6-10. omreport Fan Status Required Command Levels Optional name=value pairs (1, 2, 3) and name=value pair Use omreport storage enclosure Displays property information for all enclosures attached to the system. Displays the fans for the specified enclosure. controller=id enclosure= info=fans where id is the controller number and ENCLOSUREID is the enclosure number.
omreport Power Supply Status Table 6-11 describes the syntax for the omreport Power Supply Commands Table 6-11. omreport Power Supply Commands Required Command Levels (1, Optional name=value pairs 2, 3) and name=value pair Use omreport storage enclosure Displays property information for all enclosures attached to the system. Displays the power supplies for the specified enclosure.
omreport EMM Status NOTE: The status of the EMMs is displayed as degraded if there is a mismatch between the EMM firmware. Table 6-12 describes the syntax for the omreport EMM Commands Table 6-12. omreport EMM Commands Required Command Levels Optional name=value pairs Use (1, 2, 3) and name=value pair omreport storage enclosure Displays property information for all enclosures attached to the system.
omreport Enclosure Slot Occupancy Report Table 6-13 describes the syntax for the omreport Enclosure Slot Occupancy Report Commands Table 6-13. omreport Enclosure Slot Occupancy Report Commands Required Command Levels Optional name=value pairs Use (1, 2, 3) and name=value pair omreport storage enclosure Displays property information for all enclosures attached to the system. controller=id enclosure= Displays the empty and occupied slot details for the info=pdslotreport specified enclosure.
omreport Physical Disk Status Table 6-14 describes the syntax for the omreport Physical Disk Commands Table 6-14. omreport Physical Disk Commands Required Command Levels (1, 2, 3) and name=value pair Optional name=value pairs Use omreport storage pdisk controller=id Displays all physical disks attached to the specified controller. where id is the controller number.
omreport Virtual Disk Status Table 6-15 describes the syntax for the omreport Virtual Disk Commands Table 6-15. omreport Virtual Disk Commands Required Command Levels (1, 2, 3) Optional name=value pairs omreport storage vdisk controller=id where id is the controller number. For example: controller=0. controller=id vdisk=id where id is the controller number and the virtual disk number. For example: controller=0 vdisk=1. Use Displays property information for all virtual disks on all controllers.
omconfig Global Enable Smart Thermal Shutdown By default, the operating system and server shut down when the PV220S and PV221S enclosures reach a critical temperature of 0 or 50° Celsius. However, if you have implemented connector redundancy on the PV220S and PV221S enclosures you can specify that only the enclosure and not the operating system and server be shut down when the enclosure reaches a critical temperature of 0 or 50° Celsius.
Complete Syntax omconfig storage globalinfo action=disablests Example Syntax The omconfig command syntax for disabling thermal shutdown does not require that you specify a controller or enclosure ID. To disable thermal shutdown, type the following: omconfig storage globalinfo action=disablests NOTE: You can use the omreport storage globalinfo command to determine whether smart thermal shutdown is currently enabled or disabled.
Complete Syntax For dedicated hot spare protection policy, type: omconfig storage globalinfo action= setprotectionpolicies type=dhs raid= hscount=<1-16> warnlevel= <0-3> where hscount is the number of hot spares to be assigned to the virtual disk and warnlevel is the severity level you want to assign to the generated alert, if this policy is violated. Use hscount=0 warnlevel=0 to reset the dedicated hot spare protection policy for the RAID level.
Table 6-17.
Table 6-17.
omconfig Rescan Controller Use the following omconfig command syntax to rescan a controller. See Dell OpenManage Online Help for more information about Rescan Controller. Complete Syntax omconfig storage controller action=rescan controller=id where id is the controller ID as reported by the omreport storage controller command.
omconfig Disable Controller Alarm Use the following omconfig command syntax to disable the controller alarm. See the Dell OpenManage Online Help for more information about Disable Controller Alarm. Complete Syntax omconfig storage controller action=disablealarm controller=id where id is the controller ID as reported by the omreport storage controller command.
omconfig Test Controller Alarm Use the following omconfig command syntax to test the functionality of the controller alarm. The alarm will sound for about two seconds. See the Dell OpenManage Online Help for more information about Test Controller Alarm. Complete Syntax omconfig storage controller action=testalarm controller=id where id is the controller ID as reported by the omreport storage controller command.
omconfig storage controller action=resetconfig controller=id force=yes Example Syntax To reset the configuration on controller 1, type: omconfig storage controller action=resetconfig controller=1 omconfig Create Virtual Disk The Dell OpenManage Online Help provides additional information about creating virtual disks. The omconfig syntax for creating a virtual disk has several parameters.
Complete Syntax omconfig storage controller action=createvdisk controller=id raid= size= pdisk= [stripesize=< 2kb| 4kb| 8kb| 16kb| 32kb| 64kb| 128kb>] [cachepolicy=] [diskcachepolicy= ][readpolicy=] [writepolicy=] [name=] [spanlength=] | [secureflag=yes] NOTE: If you are configuring RAID for SAS controllers with firmware version 6.
raid= Parameter (Required) Use the raid= parameter to specify concatenation or a RAID level for a virtual disk. Different controllers support different RAID levels. See the Dell OpenManage Online Help for more information about RAID levels a controller supports and for general information about RAID levels and concatenation. Table 6-18 indicates how to specify the raid=n parameter for each RAID level and concatenation.
size= Parameter (Required) Table 6-19 indicates how to specify the size= parameter. Table 6-19. Size Parameter size= Description Parameter Specification size= size=max size=min Use this specification to indicate a specific size for the virtual disk. The virtual disk size may be specified in b (bytes), m (megabytes), or g (gigabytes). For example, size=500m indicates that the virtual disk should be 500 MB.
[cachepolicy=] Parameter (Optional) Different controllers support different cache policies. Table 6-20 indicates how to specify the [cachepolicy=] parameter for each of the cache policies. Table 6-20. Cache Policy Parameters Cache Policy cachepolicy=d | c Parameter Specification Direct I/O Cache I/O cachepolicy=d cachepolicy=c [diskcachepolicy=] Parameter (Optional) Different controllers support different disk cache policies.
[writepolicy=] Parameter (Optional) Different controllers support different write policies. Table 6-22 indicates how to specify the [writepolicy=] parameter for each of the write policies. Table 6-22.
Example Syntax For example, you may want to create a RAID-5 virtual disk on a PERC 3/QC controller. See the Dell OpenManage Online Help for information on read, write, and cache policies are supported by this controller. For example, to create a virtual disk with the following read, write, and cache policy: • Read-ahead • Write–through caching • Cache I/O The virtual disk will be 500 MB with a stripe size of 16 KB.
Example Syntax To set the rebuild rate to 50 on controller 1, type: omconfig storage controller action=setrebuildrate controller=1 rate=50 omconfig Set Background Initialization Rate Use the following omconfig command syntax to set the background initialization rate. Complete Syntax omconfig storage controller action=setbgirate controller=id rate=<0 to 100> where id is the controller ID as reported by the omreport storage controller command.
Example Syntax To set the reconstruct rate to 50 on controller 1, type: omconfig storage controller action= setreconstructrate controller=1 rate=50 omconfig Set Check Consistency Rate Use the following omconfig command syntax to set the check consistency rate. Complete Syntax omconfig storage controller action= setcheckconsistencyrate controller=id rate=<0 to 100> where id is the controller ID as reported by the omreport storage controller command.
Example Syntax To export the log on controller 1, type: omconfig storage controller action=exportlog controller=1 By default, the log file is exported to C:\WINNT or C:\Windows on Microsoft Windows systems (based on the Windows version used) and /var/log on all Linux systems. Depending on the controller, the log file name will either be afa_.log or lsi_.log where is the month and date. See the Dell OpenManage Online Help for more information on the controller log file.
Complete Syntax omconfig storage controller action= importrecoverforeignconfig controller=id where id is the controller ID as reported by the omreport storage controller command. NOTE: This command is supported only in firmware version 5.1.1.
Complete Syntax omconfig storage controller action= setpdiskpwrmanagement spindownunconfigureddrives= spindownhotspares= spindowntimeinterval=<30 to 1440 minutes> controller=id Example Syntax To spin down drives that are not configured or hot spares that are unattended for 30 minutes, type: omconfig storage controller action= setpdiskpwrmanagement spindownunconfigureddrives= enabled spindownhotspares=enabled spindowntimeinterval=30 controller=1 omconfig Set Patrol Re
omconfig Start Patrol Read Use the following omconfig command syntax to start the patrol read task on the controller. Complete Syntax omconfig storage controller action=startpatrolread controller=id where id is the controller ID as reported by the omreport storage controller command. Example Syntax To start the patrol read task on controller 1, type: omconfig storage controller action=startpatrolread controller=1 NOTE: To be able to start patrol read, the current patrol read mode should be set to Manual.
omconfig Change Controller Properties Use the following omconfig command to change any or all of the following controller properties.
Example Syntax To replace physical disk (PD1) with another physical disk (PD2), type: omconfig storage vdisk action=replacememberdisk controller=0 vdisk=1 source=PD1 destination=PD2 omconfig Storage Controller Use the following omconfig storage command syntax to discard the preserved cache on the controller.
omconfig Virtual Disk Commands The following sections provide the omconfig command syntax required to execute virtual disk tasks. CAUTION: The omconfig storage vdisk action=deletevdisk controller=id vdisk=id command deletes a virtual disk. Deleting a virtual disk destroys all information including file systems and volumes residing on the virtual disk. Table 6-23.
Table 6-23. omconfig Manage Virtual Disk Commands (continued) Optional name=value pairs Required Command Levels (1, 2, 3) action=rename controller=id vdisk=id action=clearvdbadblocks controller=id vdisk=id action=replacememberdisk controller=id vdisk=id source= destination= action=securevd controller=id vdisk=id omconfig Blink Virtual Disk Use the following omconfig command syntax to blink the physical disks included in a virtual disk.
where id is the controller ID and virtual disk ID as reported by the omreport command. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller= ID to display the IDs for the virtual disks attached to the controller.
where id is the controller ID and virtual disk ID as reported by the omreport command. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller= ID to display the IDs for the virtual disks attached to the controller.
omconfig Slow Initialize Virtualize Disk Use the following omconfig command syntax to slow initialize a virtual disk. CAUTION: You may receive a warning message if you attempt to delete the system or boot partition. However, this warning message is not generated always. Ensure that you do not delete the system or boot partition or other vital data when using this command.
where id is the controller ID and virtual disk ID as reported by the omreport command. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller= ID to display the IDs for the virtual disks attached to the controller.
Complete Syntax omconfig storage vdisk action=splitmirror controller=id vdisk=id where id is the controller ID and virtual disk ID as reported by the omreport command. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
omconfig Assign Dedicated Hot Spare Use the following omconfig command syntax to assign one or more physical disks to a virtual disk as a dedicated hot spare. NOTE: The PERC 2/SC, 2/DC, and CERC SATA 1.5/2s controllers do not support dedicated hot spares. Complete Syntax omconfig storage vdisk action= assigndedicatedhotspare controller=id vdisk=id pdisk= assign=yes where id is the controller ID and virtual disk ID. The variable specifies the physical disk.
omconfig Unassign Dedicated Hot Spare Use the following omconfig command syntax to unassign one or more physical disks previously assigned as a hot spare to a virtual disk. Complete Syntax omconfig storage vdisk action= assigndedicatedhotspare controller=id vdisk=id pdisk= assign=no where id is the controller ID and virtual disk ID. The variable specifies the physical disk.
omconfig Check Consistency Use the following omconfig command syntax to initiate a check consistency on a virtual disk. The check consistency task verifies the virtual disk’s redundant data. Complete Syntax omconfig storage vdisk action=checkconsistency controller=id vdisk=id where id is the controller ID and virtual disk ID as reported by the omreport command.
omconfig Pause Check Consistency Use the following omconfig command syntax to pause a check consistency while in progress. See the Dell OpenManage Online Help for more information about Pause Check Consistency. Complete Syntax omconfig storage vdisk action= pausecheckconsistency controller=id vdisk=id where id is the controller ID and virtual disk ID as reported by the omreport command.
omconfig Delete Virtual Disk Use the following omconfig command syntax to delete a virtual disk. CAUTION: Deleting a virtual disk destroys all information including file systems and volumes residing on the virtual disk. You may receive a warning message if you attempt to delete the system or boot partition. However, this warning message is not generated always. Ensure that you do not delete the system or boot partition or other vital data when using this command.
where id is the controller ID and virtual disk ID as reported by the omreport command. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
omconfig storage vdisk action=reconfigure controller=1 vdisk=4 raid=r5 pdisk= 0:2:0,0:2:1,0:2:2,0:2:3 Example Syntax to resize To increase the size of the virtual disk by 20 percent using the available free space, use RAID-5 and physical disks 0 through 3 on connector 0 of controller 1. On a SAS controller, the physical disks reside in enclosure 2.
• [writepolicy=] Parameter (Optional) • [cachepolicy=] Parameter (Optional) • [diskcachepolicy=] Parameter (Optional) Example Syntax To change the read policy of virtual disk 4 on controller 1 to no-read-ahead, type: omconfig storage vdisk action=changepolicy controller=1 vdisk=4 readpolicy=nra omconfig Rename Virtual Disk Use the following omconfig command syntax to rename a virtual disk. NOTE: On a CERC SATA 1.
where id is the controller ID and virtual disk ID as reported by the omreport command. To obtain the values for controller ID and virtual disk ID, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
Table 6-24. omconfig Physical Disk Commands (continued) Required Command Levels Optional name=value pairs (1, 2, 3) action=cancelreplacemember controller=id pdisk= action=instantsecureerase controller=id pdisk= omconfig Blink Physical Disk You can blink the light (light emitting diode or LED display) on one or more physical disks attached to a controller. Use the following omconfig command syntax to blink one or more physical disks.
omconfig Unblink Physical Disk You can unblink the light (light emitting diode or LED display) on one or more physical disks attached to a controller. Use the following omconfig command syntax to unblink one or more physical disks. Complete Syntax omconfig storage pdisk action=unblink controller= id pdisk= where id is the controller ID. The variable specifies the physical disk.
where id is the controller ID. The variable specifies the physical disk. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller. Example Syntax In this example, you want to prepare physical disk 3 on connector 0 of controller 1 for removal. On a SAS controller, the physical disk resides in enclosure 2.
Example Syntax In this example, you want to initialize physical disk 3 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.
Complete Syntax omconfig storage pdisk action=offline controller= id pdisk= where id is the controller ID. The variable specifies the physical disk. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller. Example Syntax In this example, you want to offline physical disk 3 on connector 0 of controller 1.
Example Syntax In this example, you want to bring physical disk 3 on connector 0 of controller 1 back online. On a SAS controller, the physical disk resides in enclosure 2.
omconfig storage pdisk action=assignglobalhotspare controller=1 pdisk=0:3 assign=yes Example for SAS Controllers To assign the physical disk described in this example as a global hot spare, type: omconfig storage pdisk action=assignglobalhotspare controller=1 pdisk=0:2:3 assign=yes omconfig Unassign Global Hot Spare Use the following omconfig command syntax to unassign a physical disk as a global hot spare.
Example for SAS Controllers To unassign the physical disk described in this example as a global hot spare, type: omconfig storage pdisk action=assignglobalhotspare controller=1 pdisk=0:2:3 assign=no omconfig Rebuild Physical Disk Use the following omconfig command syntax to rebuild a failed physical disk. Rebuilding a disk may take several hours. If you need to cancel the rebuild, use the Cancel Rebuild task. See the Dell OpenManage Online Help for more information about Rebuild Physical Disk.
omconfig Cancel Rebuild Physical Disk Use the following omconfig command syntax to cancel a rebuild that is in progress. If you cancel a rebuild, the virtual disk remains in a degraded state. See the Dell OpenManage Online Help for more information about Cancel Rebuild Physical Disk. Complete Syntax omconfig storage pdisk action=cancelrebuild controller=id pdisk= where id is the controller ID. The variable specifies the physical disk.
Complete Syntax omconfig storage pdisk action=removedeadsegments controller=id pdisk= where id is the controller ID. The variable specifies the physical disk. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller. Example Syntax In this example, you want to remove dead disk segments on physical disk 3 on connector 0 of controller 1.
To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller. Example Syntax In this example, you want to clear physical disk 3 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.
omconfig Cancel Replace Member Use the following omconfig command syntax to cancel a replace member operation. Complete Syntax action=cancelreplacemember controller=id pdisk= where id is the physical disk IDs as reported by the omreport command.
Complete Syntax omconfig storage battery action=recondition controller=id battery=id where id is the controller ID and battery ID as reported by the omreport command. To obtain this value, type omreport storage controller to display the controller IDs and then type omreport storage battery controller=ID to display the ID for the controller battery.
Complete Syntax omconfig storage battery action=delaylearn controller=id battery=id days=d hours=h where id is the controller ID and battery ID as reported by the omreport command. To obtain this value, type omreport storage controller to display the controller IDs and then type omreport storage battery controller=ID to display the ID for the controller battery.
where id is the controller ID and the connector ID as reported by the omreport command. To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage connector controller=ID to display the IDs for the connectors attached to the controller.
Table 6-27.
omconfig Enable Enclosure Alarm Use the following omconfig command syntax to enable the enclosure alarm: Complete Syntax omconfig storage enclosure action=enablealarm controller=id enclosure= where id is the controller ID. The variable specifies the enclosure.
Example for SCSI, SATA, and ATA Controllers To disable the alarm on the enclosure attached to connector 2 on controller 1, type: omconfig storage enclosure action=disablealarm controller=1 enclosure=2 Example for SAS Controllers To disable the alarm on enclosure 2 attached to connector 1 on controller 1, type: omconfig storage enclosure action=disablealarm controller=1 enclosure=1:2 omconfig Set Enclosure Asset Tag Use the following omconfig command syntax to specify the enclosure’s asset tag: Complete S
omconfig Set Enclosure Asset Name Use the following omconfig command syntax to specify the asset name for an enclosure. Complete Syntax omconfig storage enclosure action=setassetname controller=id enclosure= assetname= where id is the controller ID. The variable specifies the enclosure. In this syntax, is a user-specified alphanumeric string.
where id is the controller ID and the temperature probe ID. The variable specifies the enclosure. In this syntax, “n” is a user-specified value for the temperature in Celsius. Example Syntax For example, you may want to specify the minimum and maximum warning thresholds for temperature probe 3 to 10 and 40° Celsius. Example for SCSI, SATA, and ATA Controllers In this example, temperature probe 3 resides in the enclosure attached to connector 2 on controller 1.
Example for SCSI, SATA, and ATA Controllers In this example, temperature probe 3 resides in the enclosure attached to connector 2 on controller 1. To reset the thresholds for temperature probe 3 to the default values, type: omconfig storage enclosure action=resettempprobes controller=1 enclosure=2 index=3 omconfig Set All Temperature Probe Thresholds Use the following omconfig command syntax to set the minimum and maximum warning temperature thresholds for all temperature probes in the enclosure.
omconfig Reset All Temperature Probe Thresholds Use the following omconfig command syntax to reset the minimum and maximum warning temperature thresholds back to their default value for all temperature probes in the enclosure. NOTE: This command is not supported on SCSI RAID controllers. Complete Syntax omconfig storage enclosure action= resetalltempprobes controller=id enclosure= where id is the controller ID. The variable specifies the enclosure.
Example for SCSI, SATA, and ATA Controllers To blink the LEDs for the enclosure attached to connector 2 on controller 1, type: omconfig storage enclosure action=blink controller=1 enclosure=2 Example for SAS Controllers To blink the LEDs for enclosure 3 attached to connector 2 on controller 1, type: omconfig storage enclosure action=blink controller=1 enclosure=2:3 246 Using the Storage Management Service
Using the Storage Management Service 247
Using the Storage Management Service
Using the Storage Management Service 249
Using the Storage Management Service
7 Working With CLI Command Results Server Administrator Command Line Interface (CLI) users can use the command output in various ways. This section explains how to save command output to a file and how to select a format for your command results that fits different objectives. Table 7-1.
Linux Enterprise Server terminal. To display command output with control over scrolling, type the CLI command and append the pipe symbol followed by more. For example, type: omreport system summary | more or omreport servermodule summary | more The multiscreen system summary displays the first screen. When you want to see the next screen of command output, press the spacebar.
Four hours later, you repeat the command. You have no interest in the 11:00 A.M. snapshot as written to fans.txt. You type the same command: omreport chassis fans index=0 -outc fans.txt or omreport mainsystem fans index=0 -outc fans.txt The 3:00 P.M. data overwrites the 11:00 A.M. data in the fans.txt file. Fans.
Fans.
The available formats include: • List (lst) • Semicolon-separated values (ssv) • Table (tbl) • Raw XML (xml) • Custom delimited format (cdv) The Syntax for the formatting option is: -fmt For example, type: omreport system summary -fmt tbl or omreport servermodule summary -fmt tbl where -fmt tbl specifies table format. You can combine the formatting option with the option to direct output to a file. For example, type: omreport system summary -fmt tbl -outa summary.
No special formatting option is required because list format is the default display format. The network data part of the example system summary appears as follows: -------------Network Data -------------Network Interface Card 0 Data IP Address: 143.166.152.108 Subnet Mask: 255.255.255.0 Default Gateway: 143.166.152.1 MAC Address: 00-02-b3-23-d2-ca Table (tbl) Use the tbl or table formatting option to have your data formatted in table rows and columns.
Semicolon-separated Values (ssv) Use the ssv formatting option to deliver output formatted in semicolonseparated value format. This format also allows you to import your command output results into a spreadsheet program such as Microsoft Excel, or into a database program.
Custom Delimited Format (cdv) Use the cdv formatting option to report exported data in custom delimited format. You can specify this option with any omreport command. For example, to generate a system summary in custom delimited format, type: omreport system summary -fmt cdv or omreport servermodule summary -fmt cdv You can also set preferences for the custom delimited format with the omconfig command.
Index Symbols -? omconfig, 86 omconfig chassis, 89 omreport, 35 request for help, 23 alertlog clearing logs, 139 omconfig system, 23, 82 omreport system, 62 arrays memory, 31, 75 asset information, 151 A about omconfig, 87 acquisition information, 152 optional parameters, 25 assetinfo acquisition, 65 omreport system, 65 assign dedicated hot spare omconfig, 215 assign global hot spare omconfig, 229 acquisition information adding, 152 available alert actions, 135 acswitch omreport chassis, 38 omreport c
bios omreport chassis, 39 biossetup omconfig chassis, 89 omreport chassis, 39 blink omconfig, 245 blink physical disk omconfig, 224 bmc omconfig chassis, 114 omreport chassis, 59 chassis omconfig, 89 chassis fault LED, 108 chassis identification LED, 108 chassis information summary, 46 check consistency omconfig, 217 check consistency rate omconfig, 201 clear foreign configuration omconfig, 203 clear physical disk omconfig, 233 C cache policy parameters, 197 cache properties omreport chassis processors, 5
Windows command prompt, 16 cmdlog omconfig system, 139 omreport system, 62 connector omconfig storage, 237 connector commands omconfig, 237 command levels 1,2, and 3 omconfig, 81 connector name omreport chassis processors, 52 command levels 1,2,3 omreport, 29 connector status omreport, 175 command syntax overview, 21 controller battery, 175-176 BMC, 59, 69, 85 display IDs, 171 omconfig storage, 188-189 omreport storage, 174 SATA, 100 commands for clearing logs, 139 commands for viewing logs, 62 comp
default maximum warning threshold, 104 omconfig system, 139 omreport system, 62 default minimum warning threshold, 104 event name alert actions, 135 omconfig system platformevents, 141 defining alert actions, 134 delay battery learn cycle omconfig, 236 delete virtual disk omconfig, 219 delimiters data fields, 129 depreciation information about, 154 adding, 154 dirservice omconfig preferences, 129 disable enclosure alarm omconfig, 240 display IDs, 171-172 event notification configuring, 143 index, 145 s
omreport chassis, 44 firmware omreport chassis, 45 format virtual disk, 219 formatting CLI command output, 254 frontpanel omconfig chassis, 105 omreport chassis, 45 initialize virtual disk omconfig, 210 introduction, 15 intrusion omreport chassis, 47 IP address alert destinations, 139 IRQ level omreport chassis ports, 51 G L globalinfo omconfig storage, 184 omreport storage, 175 lease information, 157 H levels of help for a CLI command, 24 help, levels of, 24 hot spare, 215 leds omconfig chassis, 1
minimum warning threshold, 127 N name=value pairs omconfig chassis biossetup, 89 omconfig chassis bmc, 115 nics omreport chassis, 50 NMI button, 45 O offline physical disk omconfig, 227 omconfg cancel initialize virtual disk, 210 omconfig -?, 86 about, 87 assign dedicated hot spare, 215 assign global hot spare, 229 blink physical disk, 224 blink virtual disk, 209 cancel background initialize, 212 cancel check consistency, 217 cancel rebuild physical disk, 232 change virtual disk policy, 221 chassis, 89 ch
set enclosure asset name, 242 set enclosure asset tag, 241 set temperature probe thresholds, 242 split mirror, 213 system, 134 test controller alarm, 192 unassign dedicated hot spare, 216 unassign global hot spare, 230 unblink physical disk, 225 unblink virtual disk, 209 unmirror, 214 omconfig about details=true, 87 omconfig battery commands, 235 omconfig channel commands, 237 omconfig chassis, 89 -?, 89 biossetup, 89 bmc, 114 currents, 104 fancontrol, 105 fans, 104 frontpanel, 105 info, 107 leds, 108 memor
dirservice, 129 snmp, 130-131 useraccess, 132 webserver, 132 omconfig preferences dirservice name=value pair, parameters, 130 omconfig preferences snmp name=value pairs, parameters, 131 omconfig storage battery, 235 connector, 237 controller, 188-189 enclosure, 238 globalinfo, 184 pdisk, 170, 223 vdisk, 208 omconfig system alertaction, 134 alertlog, 23, 82, 139 assetinfo, 151 cmdlog, 139 esmlog, 139 events, 143 extwarranty, 155 name=value pairs, parameters, 144 pedestinations, 139 platformevents, 140 recove
about, 36 battery status, 175 chassis, 37 command levels 1, 2, 3, 29 command summary, 28 connector status, 175 controller status, 174 EMM status, 181-182 enclosure status, 176 fan status, 179 getting help, 35 global information, 174 physical disk status, 183 power supply status, 180 system, 61 temperature probe status, 178 virtual disk status, 184 omreport chassis acswitch, 38 bios, 39 biossetup, 39, 43 currents, 43 fancontrol, 45 fans, 44 firmware, 45 frontpanel, 45 fru, 45 intrusion, 47 leds, 48 memory, 4
enclosure, 176, 178-182 globalinfo, 175 pdisk, 183 vdisk, 184 omreport system alertaction, 63 alertlog, 62 assetinfo, 65 cmdlog, 62 esmlog, 62 events, 65 operatingsystem, 67 pedestinations, 68 platformevents, 69 recovery, 69 shutdown, 70 summary, 70 thrmshutdown, 76 version, 76 omreport system assetinfo, 65 omreport system commands, 61 omreport system events name=value pairs, 66 omrpeort system components, 61 online physical disk omconfig, 228 operating system omreport system, 67 outsource information, 160
processors omreport chassis, 51 omconfig, 245 pwrmanagement, 55 restore dead segments omconfig, 213 pwrsupplies omreport chassis, 58 resume check consistency omconfig, 218 R S read policy parameters, 197 scripting, 20 rebuild physical disk omconfig, 231 scripting with the CLI, 20 recondition battery omconfig, 235 service contract information, 162 adding, 162 reconfiguring virtual disks omconfig, 220 reconstruct rate omconfig, 200 recovery omconfig system, 146 omreport system, 69 recovery from
smart thermal shutdown status, 174 temperature probe warning threshold, 127 snmp omconfig preferences, 130 temps omconfig chassis, 126 omreport chassis, 60 SNMP traps, 143 disabling, 143 enabling, 143 split mirror omconfig, 213 start battery learn cycle omconfig, 236 state omreport chassis processors, 52 thermal shutdown about, 76 configuring, 148 example commands, 149 thrmshutdown omconfig system, 148 omreport system, 76 storage management, 169 U storage management CLI, 169 successful commands, 18
V vdisk omconfig storage, 208 omreport storage, 184 CLI, 16 write policy parameters, 198 version omreport system, 76 viewing alert actions for specific components and events, 63 viewing properties for system temperature probes, 60 viewing properties for system voltage probes, 61 viewing properties of system power supplies, 58 viewing properties of system slots, 60 voltage warning thresholds, 127 volts omconfig chassis, 127 omreport chassis, 61 W warranty adding, 167 components, 155, 167 omconfig system,
Index 272