book.
book.book Page 2 Monday, March 14, 2011 3:01 PM Notes and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. __________________ Information in this publication is subject to change without notice. © 2003–2011 Dell Inc. All rights reserved. Reproduction of these materials whatsoever without the written permission of Dell Inc. is strictly forbidden.
book.book Page 3 Monday, March 14, 2011 3:01 PM Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . Supported SNMP Versions . . . . . . . . . . . . . . . Introduction to the SNMP Reference Guide . . . . . . 15 15 16 Server Administrator Instrumentation MIB . . . . 17 Server Administrator Remote Access MIB . . . . 20 Server Administrator Baseboard Management Controller, ASF MIB . . . . . . . . . . . . . . . . 20 . . . . . . . . . . . . . . . . . . . . . .
book.book Page 4 Monday, March 14, 2011 3:01 PM Updates For Dell OpenManage Server Administrator Version 6.5 . . . . . . . . . 2 What’s New in This Release Device Group . . . . . . . . . . 39 . . . . . . . . . . . . . . . . . . . . . . 40 Device Tables . . . . . . . . . . . . . . . . . . . . Network Device Table . . . . . . . . . . . . . . . Device Group Variable Values Memory Group . . . . . . . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . 41 . . . . . . . 41 . . . . . . .
book.book Page 5 Monday, March 14, 2011 3:01 PM 5 6 System State Group . . . . . . . . . . . . . . . . . 55 System State Group Table . . . . . . . . . . . . . . . . 55 System State Table . . . . . . . . . . . . . . . . . 55 System State Table . . . . . . . . . . . . . . . . . 57 Chassis Information Group . . . . . . . . . . . 77 Chassis Information Group Tables . . . . . . . . . . . 77 . . . . . . . . . . . . . 77 . . . . . . . . . . . . . . . . . . . . .
book.book Page 6 Monday, March 14, 2011 3:01 PM System Resource Direct Memory Access (DMA) Table . . . . . . . . . . . . . . . . . . . . . . . System Resource Group Variable Values 9 Power Group . . . . . . . . 152 . . . . . . . . . . . . . . . . . . . Power Unit Table . . . . . . . . . . . . . . . . . . 157 157 157 Power Supply Table . . . . . . . . . . . . . . . . 160 Voltage Probe Table . . . . . . . . . . . . . . . . 164 Amperage Probe Table . . . . . . . . . . . . . . .
book.book Page 7 Monday, March 14, 2011 3:01 PM 12 Remote Flash BIOS Group . Remote Flash BIOS Group Table Remote Flash BIOS Table 227 . . . . . . . . . . . . . 227 233 239 . . . . . . . . . . . . . . . Memory Device Port Table . . . . . . . . . . . . . 242 . . . . . . . . . . . . . . . . . 245 Small Computer System Interface (SCSI) Port Table . . . . . . . . . . . . . . . . . . . . . . . . 248 . . . . . . . . . . . . . . . . . 250 . . . . . . . . . . . . . . . . . .
book.book Page 8 Monday, March 14, 2011 3:01 PM PCI Device Configuration Space Table . Network Device Table . . . . . . 306 . . . . . . . . . . . . . . . 309 Managed System Services Device Table SD Card Unit Table . . . . . 317 . . . . . . . . . . . . . . . . . 319 SD Card Device Table . . . . . . . . . . . . . . . Device Group Variable Values 15 Slot Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Slot Group Table . System Slot Table . . . . . . . . .
book.book Page 9 Monday, March 14, 2011 3:01 PM Diskette Control Table Network Interface Control Table . BIOS Group Variable Values . . . . . . . . . 416 . . . . . . . . . . . . . . 419 18 Local Response Agent Group LRA Group Tables 414 . . . . . . . . . . . . . . . . . . . . . . . 429 429 . . . . . . . . . . . . . . . . . . . . LRA Global Settings LRA Action Table 429 . . . . . . . . . . . . . . . . LRA Global Settings Table . . . . . . . . . . . . . 430 . . . . . . . . . . . . . . . . .
book.book Page 10 Monday, March 14, 2011 3:01 PM DRAC III . . . . . . . . . . . . . . . . . . . . . . . . . Remote Access Table . . . . . . . . . . . . . . . Remote User Administration Table . . . . . . . . . 487 495 . . . . . . . . . . . . . . . 500 Remote User Dial-In Configuration Table Remote Dial-Out Table . . . . . 504 . . . . . . . . . . . . . . . 507 Remote Access Variable Values 21 Cluster Group Cluster Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
book.book Page 11 Monday, March 14, 2011 3:01 PM 24 Storage Management Group . Storage Management Group . . . . . . . . 553 . . . . . . . . . . . . . . Storage Management Information Group . Global Data Group . 553 . . . . . . . 555 . . . . . . . . . . . . . . . . . . . 556 Physical Devices Group . . . . . . . . . . . . . . . . . 562 . . . . . . . . . . . . . . . . . . 563 . . . . . . . . . . . . . . . . . . . 583 Enclosure Table . . . . . . . . . . . . . . . . . .
book.book Page 12 Monday, March 14, 2011 3:01 PM Application Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 677 . . . . . . . . . . . . . . . . 679 Application Group Table Operating System Group . Inventory Collector Product Information 26 Dell Remote Access Controller Out-of-Band Group . . . . . . . . . Product Information Chassis Status 687 . . . . . . . . . . . . . . . 696 . . . . . . . . . . . . . . . . . . . . . 697 . . . . . . . . . . . . . . . . . 698 . . .
book.book Page 13 Monday, March 14, 2011 3:01 PM Power Supply Traps Memory Device Traps Fan Enclosure Traps . . . . . . . . . . . . . . . 733 . . . . . . . . . . . . . . . . 734 . . . . . . . . . . . . . . . 735 . . . . . . . . . . . . . . . . 736 AC Power Cord Traps Hardware Log Traps Processor Device Status Traps . . . . . . . . . . 737 . . . . . . . . . . . . . . 739 . . . . . . . . . . . . . . . . . . . . 740 Pluggable Device Traps Battery Traps 731 . . . . . . . . . . . . . . . .
book.book Page 14 Monday, March 14, 2011 3:01 PM Dell Status Data Types . Dell Date . . . . . . . . . . . . . . . . . 764 . . . . . . . . . . . . . . . . . . . . . . . . . 765 Full Dates . . . . . . . . . . . . . . . . . . . . . . B SNMP Sample Output Index 14 766 . . . . . . . . . . . . . . 767 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
book.book Page 15 Monday, March 14, 2011 3:01 PM 1 Introduction This reference guide provides information about the Simple Network Management Protocol (SNMP) Management Information Base (MIB) which is applicable for Dell OpenManage Version 6.4. NOTE: This guide contains information that may also be applicable to earlier OpenManage supported platforms. This introduction is divided into two sections.
book.book Page 16 Monday, March 14, 2011 3:01 PM Introduction to the SNMP Reference Guide This reference guide provides a formatted version of the following Management Information Base that are released with the current version of Dell OpenManage. Management Information Base (MIB) Name Management Information Base (MIB) Filename Server Administrator Instrumentation MIB 10892.mib Remote Access MIB dcs3rmt.mib Server Administrator Field Replaceable Unit MIB dcs3fru.
book.book Page 17 Monday, March 14, 2011 3:01 PM Table 1-1. General Content Sections in This Guide (continued) Section Topics MIB Group Number Appendix A Standard Data Type Definitions — defines standard data types used in this reference guide. NA Appendix B SNMP Sample Output — provides a sample SNMP output. NA Server Administrator Instrumentation MIB The Server Administrator Instrumentation MIB (filename 10892.
book.book Page 18 Monday, March 14, 2011 3:01 PM Table 1-2.
book.book Page 19 Monday, March 14, 2011 3:01 PM Table 1-2. Server Administrator Instrumentation MIB Sections in This Guide Section Topics MIB Group Numbers 16 BIOS Setup Control Group — defines variables for BIOS functions such as boot sequence, speakers, Wake on the local area network (LAN), diskettes, ports, and network interface controllers (NIC) 1400 17 Local Response Agent Group — defines variables for global settings and actions.
book.book Page 20 Monday, March 14, 2011 3:01 PM Server Administrator Remote Access MIB The Server Administrator Remote Access MIB (filename dcs3rmt.mib) provides in-band information about remote access hardware that may be present in your system. The Server Administrator Remote Access MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information.
book.book Page 21 Monday, March 14, 2011 3:01 PM The Server Administrator Field Replaceable Unit MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. Table 1-4 describes each Server Administrator Field Replaceable Unit MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Field Replaceable Unit MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1.
book.book Page 22 Monday, March 14, 2011 3:01 PM Table 1-5.
book.book Page 23 Monday, March 14, 2011 3:01 PM Dell Remote Access Controller Out-of-Band MIB The Dell Remote Access Controller Out-of-Band MIB (filename dellRAC.mib) provides management data that allows you to monitor the Chassis Management Controller. This MIB also contains information on RAC legacy alerting. Table 1-7 describes each Dell RAC Out-of-Band group and lists the MIB group number assigned to the MIB group.
book.book Page 24 Monday, March 14, 2011 3:01 PM Table 1-8. Where to Find Definitions for Technical Terms (continued) Type of Definition See Server Administrator-standard data types that specify Appendix A, "Standard Data variable values in this reference guide. Type Definitions" on page 761. SNMP Basic Terminology It is important to have a good understanding of the key technical terms used in this guide.
book.book Page 25 Monday, March 14, 2011 3:01 PM SNMP Extension Agent The SNMP extension agent is responsible for registering the MIB objects that it supports with the SNMP master agent and then processing requests from the SNMP master agent for those MIB objects. The SNMP extension agent also initiates event notifications to the SNMP master agent. The SNMP extension agent does not receive or send standard SNMP protocol messages.
book.book Page 26 Monday, March 14, 2011 3:01 PM Zero-Based Index When an index is zero-based, counting starts at 0. Zero-based indexing counts the first instance as 0, the second index as 1, and so on. Fields Managed object variables contain fields. In this reference guide, managed object variables have the following fields defined: Name is the exact string by which the variable is known in the MIB.
book.book Page 27 Monday, March 14, 2011 3:01 PM Description is a brief explanation of what a particular managed object does. Syntax defines the data type in which the values of the variable must be expressed. Most variables in this reference guide use standard data types such as string or boolean. All data types that are unique to server administrator variables are defined at the end of the section in which they occur. Standard data types are defined in "Standard Data Type Definitions" on page 761.
book.book Page 28 Monday, March 14, 2011 3:01 PM Tables This reference guide contains two types of tables: tables that are used to organize and define variable values and tables that define MIB objects. Readers must understand the difference between these two types of tables. SNMP Tables Most of the MIB objects defined in this reference guide are organized into SNMP tables. SNMP tables organize data into two-dimensional structural arrays.
book.book Page 29 Monday, March 14, 2011 3:01 PM UUID Table Entry Name uUIDTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.20.1 Description Defines the UUID table entry. Syntax UUIDTableEntry Access Not accessible Index uUIDIndex, uUIDchassisIndex UUID Chassis Index Name uUIDchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.674.
book.book Page 30 Monday, March 14, 2011 3:01 PM UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4 Description Defines the value of the UUID for this chassis. Syntax Octet String (SIZE[16]) Access Read-only Reference Guide Content Tables NOTE: Variable values are defined for any variable that is Server Administrator-specific. Industry-standard variable definitions are documented in "Standard Data Type Definitions" on page 761.
book.book Page 31 Monday, March 14, 2011 3:01 PM Section Organization Sections in this reference guide are based on the Server Administrator MIBs, so the complexity of each section depends on the complexity of each MIB group. The first section provides a high-level introduction to the MIB group. If the group is defined by one or more tables, the second section lists these tables. The third section documents the variables that comprise the group, and if applicable, the variables that comprise the tables.
book.book Page 32 Monday, March 14, 2011 3:01 PM 4 BIOS Variable Values This section explains any Server Administrator-specific variables and data types that are used in this section. In the BIOS group example, there are 17 unique, Server Administrator-specific variable meanings. Information on each Server Administrator-specific variable is presented in a formatted table.
book.book Page 33 Monday, March 14, 2011 3:01 PM For each MIB group that has unique variable definitions, tables are included in the last section of the section to explain the meaning of the terms. Standards for writing MIBs are defined by the Internet Engineering Task Force (IETF). Structure of Management Information (SMI) is a standard that specifies the rules for defining the structure and type of managed objects and events in a MIB. SMIv1 is specified in Request For Comments (RFC) 1155.
book.book Page 34 Monday, March 14, 2011 3:01 PM SNMP Management Information Base Object Identifiers Each data class within a Management Information Base (MIB) is defined by an Object Identifier (OID). OIDs are unique across all MIBs. An OID consists of a series of digits separated by periods. The OID functions in a similar fashion to a phone number. The phone number 011-512-471-0000 uniquely identifies a single phone.
book.book Page 35 Monday, March 14, 2011 3:01 PM In the preceding example, the OID prefix for the Dell enterprise would be 1.3.6.1.4.1.674. The numbers in boldface type show the categories and numbers that apply to Server Administrator. All Server Administrator-defined OIDs consist of 1.3.6.1.4.1.674 followed by additional component values. SNMP Security SNMP version 1 has a very limited security mechanism.
book.book Page 36 Monday, March 14, 2011 3:01 PM Management Actions Management actions can be performed using the SNMP Set command. These actions can consist of configuring a phone number for the system’s owner, rebooting a system, or changing the asset tag of the system. See the previous section, "SNMP Security" on page 35, for limitations on Set operations. SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on.
book.book Page 39 Monday, March 14, 2011 3:01 PM Updates For Dell OpenManage Server Administrator Version 6.5 2 This section contains information added or updated for the current release. NOTE: OpenManage Storage Management updates for Version 6.5 are also listed in this section. What’s New in This Release New Features Added • Added an attribute (Network Device Capability) to the Network Device Table in the Device Group.
book.book Page 40 Monday, March 14, 2011 3:01 PM Device Group Device Tables The following MIB table in the Device Group is updated for the current release: • Network Device Table For information about the other Device Group MIB tables, see "Device Group" on page 267. Network Device Table This section provides information about the updates done to the Network Device Table for the current release. For all other information about the Network Device Table, see "Network Device Table" on page 309.
book.book Page 41 Monday, March 14, 2011 3:01 PM Device Group Variable Values The following attribute has enumeration values added for this release: Table 2-1. Network Device Capabilities Variable Name: DellNetworkDeviceCapabilities Data Type: Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value notSupported(0) Device does not support reporting capabilities. supported(1) Device supports reporting capabilities.
book.book Page 42 Monday, March 14, 2011 3:01 PM Physical Memory Configuration Memory Operating Mode Capabilities Name physicalMemoryConfigMOMCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.8 Description Defines the Memory Operating Mode capabilities of the physical memory. Syntax DellPhysicalMemoryConfigMOMCapabilities Access Read-only Physical Memory Configuration Memory Operating Mode Settings Name physicalMemoryConfigMOMSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.
book.book Page 43 Monday, March 14, 2011 3:01 PM Table 2-2. Physical Memory Configuration Memory Operating Mode Capabilities Variable Name: DellPhysicalMemoryConfigMOMCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) There are no memory operating mode capabilities. unknownCapabilities(1) Memory operating mode capabilities are unknown. momOptimizerCapable(2) Optimizer memory operating feature is supported.
book.book Page 44 Monday, March 14, 2011 3:01 PM Table 2-4. Physical Memory Configuration Redundant Capabilities Variable Name: DellPhysicalMemoryConfigRedundantCapabilities Data Type: Integer Possible Data Values Meaning of Data Value dddcCapable(16) DDDC redundancy is supported. Table 2-5.
book.book Page 45 Monday, March 14, 2011 3:01 PM Controller Storport Driver Version Name controllerStorportDriverVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.55 Description Provides current Windows OS storport driver version. Not applicable for Linux. Syntax DisplayString Access Read-only Controller Minimum Required Storport Version Name controllerMinimumRequiredStorportVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 46 Monday, March 14, 2011 3:01 PM Array Disk Table This section provides information about the updates done to the Array Disk Table in the current release. For all other information about the Array Disk Table, see "Array Disk Table" on page 599 section. Array Disk Alta Vendor Id Name arrayDiskAltaVendorId Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.37 Description Provides vendor information for Alta interposer.
book.book Page 47 Monday, March 14, 2011 3:01 PM 3 Instrumentation MIB Version Group The Instrumentation Management Information Base (MIB) Version Group defines the attributes that identify the version of the Instrumentation MIB supported by the systems management software. The mIBMajorVersionNumber, mIBMinorVersionNumber, and mIBMaintenanceVersionNumber attributes are scalar objects, meaning that they are not related to other MIB objects and are thus not placed in a table.
book.book Page 48 Monday, March 14, 2011 3:01 PM Management Information Base Minor Version Number Name mIBMinorVersionNumber Object ID 1.3.6.1.4.1.674.10892.1.1.2.0 Description Defines the minor version number of the version of this MIB supported by the systems management software. For example, if the MIB version is 1.2.3, the minor version number is 2. A minor revision provides additional support for new objects as well as problem fixes.
book.book Page 49 Monday, March 14, 2011 3:01 PM Systems Management Software Group 4 The Systems Management Software Group allows users to see information about the standards and software that are supported by the agent of a particular managed computer chassis. The Systems Management Software Group classifies each computer chassis according to the systems management standard that the agent supports.
book.book Page 50 Monday, March 14, 2011 3:01 PM Systems Management Software Name Name systemManagementSoftwareName Object ID 1.3.6.1.4.1.674.10892.1.100.1 Description Defines the systems management software product name. Syntax DellString Access Read-only Systems Management Software Version Number Name Name systemManagementSoftwareVersionNumberName Object ID 1.3.6.1.4.1.674.10892.1.100.2 Description Defines the version number of the systems management software.
book.book Page 51 Monday, March 14, 2011 3:01 PM Systems Management Software Supported Protocol Name systemManagementSoftwareSupportedProtocol Object ID 1.3.6.1.4.1.674.10892.1.100.5 Description Defines the systems management standards (SNMP or CIM) supported by the systems management software. Syntax SMSSupportedTypes (See Table 4-1) Access Read-only Systems Management Software Preferred Protocol Name systemManagementSoftwarePreferredProtocol Object ID 1.3.6.1.4.1.674.10892.1.100.
book.book Page 52 Monday, March 14, 2011 3:01 PM Name systemManagementSoftwareURLName Access Read-only Systems Management Software Language Name Name systemManagementSoftwareLanguageName Object ID 1.3.6.1.4.1.674.10892.1.100.9 Description Defines the language of the systems management software. Syntax DisplayString (SIZE (0..255)) Access Read-only Systems Management Software Global Version Name Name systemManagementSoftwareGlobalVersionName Object ID 1.3.6.1.4.1.674.10892.1.100.
book.book Page 53 Monday, March 14, 2011 3:01 PM Name systemManagementSoftwareSNMPAgentFeatureFlags Syntax SMSSNMPAgentFeatureFlags (See Table 4-3) Access Read-only Systems Management Software Manufacturer Name Name systemManagementSoftwareManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.100.13 Description Defines the manufacturer of the systems management software.
book.book Page 54 Monday, March 14, 2011 3:01 PM Table 4-2. Systems Management Software Feature Flags Variable Name: SMSFeatureFlags Data Type: Integer Possible Data Values Meaning of Data Value none(0) The Systems Management Software features are not enabled. webOneToOneManagementPreferred(1) The web 1:1 management preferred feature is enabled. Table 4-3.
book.book Page 55 Monday, March 14, 2011 3:01 PM 5 System State Group The Management Information Base (MIB) variables presented in this section enable you to track various attributes that describe the state of the critical components supported by your system. Components monitored under the System State Group include power supplies, AC power cords, AC power switches, and cooling devices, as well as temperature, fan, amperage, and voltage probes.
book.
book.
book.book Page 58 Monday, March 14, 2011 3:01 PM System State Chassis Index Name systemStatechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System State Global System Status Name systemStateGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.2 Description Defines the global system status of all chassis being monitored by this instrumentation instance.
book.book Page 59 Monday, March 14, 2011 3:01 PM System State Power Unit State Details Name systemStatePowerUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.5 Description Defines the state of all power units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific power unit.
book.book Page 60 Monday, March 14, 2011 3:01 PM System State Power Supply State Details Name systemStatePowerSupplyStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.8 Description Defines the state of all power supplies in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific power supply.
book.book Page 61 Monday, March 14, 2011 3:01 PM System State Voltage State Details Name systemStateVoltageStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.11 Description Defines the state of all voltage probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific voltage probe.
book.book Page 62 Monday, March 14, 2011 3:01 PM System State Amperage State Details Name systemStateAmperageStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.14 Description Defines the state of all current probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific current probe.
book.book Page 63 Monday, March 14, 2011 3:01 PM System State Cooling Unit State Details Name statesystemStateCoolingUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.17 Description Defines the state of all cooling units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling unit.
book.book Page 64 Monday, March 14, 2011 3:01 PM System State Cooling Device State Details Name systemStateCoolingDeviceStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.20 Description Defines the state of all cooling devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling device.
book.book Page 65 Monday, March 14, 2011 3:01 PM System State Temperature State Details Name systemStateTemperatureStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.23 Description Defines the state of all temperature probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific temperature probe.
book.book Page 66 Monday, March 14, 2011 3:01 PM System State Memory Device State Details Name systemStateMemoryDeviceStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.26 Description Defines the state of all memory devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of the specific memory device.
book.book Page 67 Monday, March 14, 2011 3:01 PM System State Chassis Intrusion State Details Name systemStateChassisIntrusionStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.29 Description Defines the intrusion state of all intrusion detection devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific intrusion detection device.
book.book Page 68 Monday, March 14, 2011 3:01 PM System State AC Power Switch State Details Name systemStateACPowerSwitchStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.32 Description Defines the individual state of all AC power switches in this chassis. The first byte returned represents the state of the first AC power switch, the second byte returned represents the state of the second AC power switch, and so on. Syntax Octet String (Size(1..
book.book Page 69 Monday, March 14, 2011 3:01 PM System State AC Power Cord State Details Name systemStateACPowerCordStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.35 Description Defines the individual state of all AC power cords for any AC power switches in this chassis. The first byte returned represents the state of the first AC power cord, the second byte returned represents the state of the second AC power cord, and so on. Syntax Octet String (Size(1..
book.book Page 70 Monday, March 14, 2011 3:01 PM System State Redundant Memory Unit State Details Name systemStateRedundantMemoryUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.38 Description Defines the state of all redundant memory units in this chassis. The results are returned as a binary octet string, each byte of the octet string represents the state of the specific object. The first byte returned represents the state of the first object, and so on.
book.book Page 71 Monday, March 14, 2011 3:01 PM System State Event Log Status Name systemStateEventLogStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.41 Description Defines the overall status of this chassis (ESM) event log. Syntax DellStatus Access Read-only System State Power Unit Status Combined Name systemStatePowerUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.42 Description Defines the combined status of all power units of this chassis.
book.book Page 72 Monday, March 14, 2011 3:01 PM System State Cooling Unit Status Combined Name systemStateCoolingUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.44 Description Defines the combined status of all cooling units of this chassis. Syntax DellStatus Access Read-only System State Cooling Unit Status List Name systemStateCoolingUnitStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.45 Description Lists the status of each cooling unit of this chassis.
book.book Page 73 Monday, March 14, 2011 3:01 PM System State AC Power Switch Status List Name systemStateACPowerSwitchStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.47 Description Lists the status of each AC power switch of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of an AC power switch. The first byte returned represents the status of the first AC power switch, and so on.
book.book Page 74 Monday, March 14, 2011 3:01 PM System State Processor Device Status Combined Name systemStateProcessorDeviceStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.50 Description Defines the combined status of all processor devices of this chassis. Syntax DellStatus Access Read-only System State Processor Device Status List Name systemStateProcessorDeviceStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
book.book Page 75 Monday, March 14, 2011 3:01 PM Name systemStateBatteryStatusList Description Lists the status of each battery of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a battery. The first byte returned represents the status of the first battery, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String (Size(1..
book.book Page 76 Monday, March 14, 2011 3:01 PM Name systemStateSDCardDeviceStatusCombined Syntax DellStatus Access Read-only System State SD Card Device Status List Name systemStateSDCardDeviceStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.57 Description Lists the status of each SD Card device of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a SD Card device.
book.book Page 77 Monday, March 14, 2011 3:01 PM Chassis Information Group 6 The Chassis Information Group provides information about the type or types of chassis in your system, as well as information about the light-emitting diode (LED) indicators and settings for devices on each chassis. Information is also available about the current date and time displayed on the chassis, intrusion warnings, watchdog timer, systems management basic input/output system (SMBIOS), and so on.
book.book Page 78 Monday, March 14, 2011 3:01 PM Chassis Information Table Entry Name chassisInformationTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.10.1 Description Defines the chassis information table entry. Syntax ChassisInformationTableEntry Access Not accessible Index chassisIndexChassisInformation Chassis Index Chassis Information Name chassisIndexChassisInformation Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 79 Monday, March 14, 2011 3:01 PM Chassis Status Name chassisStatus Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4 Description Defines the status of the chassis. Syntax DellStatus Access Read-only Chassis Parent Index Reference Name chassisparentIndexReference Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4 Description Defines the index (one-based) of the parent chassis of this chassis, if any.
book.book Page 80 Monday, March 14, 2011 3:01 PM Chassis Manufacturer Name Name chassisManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.8 Description Defines the manufacturer’s name for this chassis. Syntax DellString Access Read-only Chassis Model Name Name chassisModelName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.9 Description Defines the system model type for this chassis. Syntax DellString Access Read-only Chassis Asset Tag Name Name chassisAssetTagName Object ID 1.
book.book Page 81 Monday, March 14, 2011 3:01 PM Chassis ID Name chassisID Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.12 Description Defines the asset tag name for this chassis. Syntax DellUnsigned8BitRange Access Read-only Chassis ID Extension Name chassisIDExtension Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.13 Description Defines the SMBIOS machine ID of this chassis. Syntax DellUnsigned16BitRange Access Read-only Chassis System Class Name chassisSystemClass Object ID 1.3.6.1.4.1.
book.book Page 82 Monday, March 14, 2011 3:01 PM Chassis System Boot Date Name Name chassisSystemBootDateName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.16 Description Defines the boot time of this system. Syntax DellDateName Access Read-only Chassis System Date Name Name chassisSystemDateName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.17 Description Defines the current time on this system.
book.book Page 83 Monday, March 14, 2011 3:01 PM Chassis System User Phone Number Name Name chassisSystemUserPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.20 Description Defines the user-assigned phone number of the primary user of the system. Syntax DellString Access Read-write Chassis Connection Status Unique Name chassisConnectionStatusUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
book.book Page 84 Monday, March 14, 2011 3:01 PM Chassis LED Control Capabilities Unique Name chassisLEDControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.24 Description Defines the capabilities of the LED control function in the chassis. Syntax DellLEDControlCapabilities (See Table 6-5) Access Read-only Chassis LED Control Settings Unique Name chassisLEDControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
book.book Page 85 Monday, March 14, 2011 3:01 PM Chassis Identify Flash Control Capabilities Name chassisIdentifyFlashControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.28 Description Specifies whether the chassis front-panel LED can be set to flash. Syntax DellChassisIdentifyControlCapabilities (See Table 6-9) Access Read-only Chassis Identify Flash Control Settings Name chassisIdentifyFlashControlSettings Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
book.book Page 86 Monday, March 14, 2011 3:01 PM Chassis Host Control Settings Unique Name chassishostControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.32 Description Defines the current settings of the host control object. Syntax DellHostControlSettings (See Table 6-12) Access Read-write Chassis Watchdog Control Capabilities Unique Name chassiswatchDogControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
book.book Page 87 Monday, March 14, 2011 3:01 PM Chassis Watchdog Control Expiry Time Name chassiswatchDogControlExpiryTime Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.36 Description Defines the current reading and allows setting of the nonrecoverable watchdog expiry timer object. Syntax DellUnsigned16BitRange Access Read-write Chassis Allow Set Commands From SNMP Name chassisallowSETCommandsfromSNMP Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
book.book Page 88 Monday, March 14, 2011 3:01 PM Name chassisPowerButtonControlSettingsUnique Syntax DellPowerButtonControlSettings (See Table 6-17) Access Read-write Chassis Reseller Name Name chassisResellerName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.40 Description Defines the name of the chassis reseller. Syntax DisplayString (SIZE (0..128)) Access Read-only Chassis Reseller Contact Information Name Name chassisResellerContactInformationName Object ID 1.3.6.1.4.1.674.10892.1.300.
book.book Page 89 Monday, March 14, 2011 3:01 PM Name chassisResellerSystemID Syntax DellUnsigned16BitRange Access Read-only Chassis NMI Button Control Capabilities Unique Name chassisNMIButtonControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.44 Description Defines the capabilities of the NMI button control function.
book.book Page 90 Monday, March 14, 2011 3:01 PM Chassis System Revision Number Name chassisSystemRevisionNumber Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.47 Description Defines the revision number of the system where zero indicates the original version of the system. The revision number is not available on all systems. Syntax DellUnsigned8BitRange Access Read-only Chassis System Revision Name Name chassisSystemRevisionName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
book.book Page 91 Monday, March 14, 2011 3:01 PM Name uUIDTable Access Not accessible UUID Table Entry Name uUIDTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.20.1 Description Defines the UUID table entry. Syntax UUIDTableEntry Access Not accessible Index uUIDIndex, uUIDchassisIndex UUID Chassis Index Name uUIDchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 92 Monday, March 14, 2011 3:01 PM Name uUIDType Syntax DellUUIDType Access Read-only UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4 Description Defines the value of the UUID for this chassis. Syntax Octet String (SIZE(16)) Access Read-only POST Log Table This section defines attributes for the power-on self-test (POST) log. When you turn on your computer, the POST checks various system components before the operating system loads.
book.book Page 93 Monday, March 14, 2011 3:01 PM Name postLogTableEntry Access Not accessible Index postLogchassisIndex, postLogRecordIndex POST Log Chassis Index Name postLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only POST Log Record Index Name postLogRecordIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.2 Description Defines the record number (one-based) of the POST log.
book.book Page 94 Monday, March 14, 2011 3:01 PM Name postLogStateSettingsUnique Syntax DellStateSettingsLogUnique Access Read-write POST Log Record Name postLogRecord Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5 Description Defines the data for the specified chassis and record index in the POST log being returned. Syntax DisplayString (SIZE (0..1024)) Access Read-only POST Log Format Name postLogFormat Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.
book.book Page 95 Monday, March 14, 2011 3:01 PM Name eventLogTableEntry Description Defines the event Log Table Entry. Syntax EventLogTableEntry Access Not accessible Index eventLogchassisIndex,eventLogRecordIndex Event Log Chassis Index Name eventLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Event Log Record Index Name eventLogRecordIndex Object ID 1.3.6.1.4.1.674.
book.book Page 96 Monday, March 14, 2011 3:01 PM Event Log State Settings Unique Name eventLogStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.4 Description Defines the state settings for the object that is writing the event log. Syntax DellStateSettingsLogUnique Access Read-write Event Log Record Name eventLogRecord Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.5 Description Defines the data for the specified chassis and log record index in the event log being returned.
book.book Page 97 Monday, March 14, 2011 3:01 PM Event Log Date Name Name eventLogDateName Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.8 Description Defines the date and time of the event log record. Syntax DellDateName Access Read-only Status Mandatory System BIOS Table This table lists objects that define the system’s basic input/output system (BIOS). Name systemBIOSTable Object ID 1.3.6.1.4.1.674.10892.1.300.50 Description Defines the System BIOS Table.
book.book Page 98 Monday, March 14, 2011 3:01 PM Name systemBIOSchassisIndex Access Read-only System BIOS Index Name systemBIOSIndex Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.2 Description Defines the index (one-based) of the system BIOS of this object. Syntax DellObjectRange Access Read-only System BIOS State Capabilities Name systemBIOSStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.3 Description Defines the capabilities of the system BIOS of this object.
book.book Page 99 Monday, March 14, 2011 3:01 PM Name systemBIOSStatus Access Read-only System BIOS Size Name systemBIOSSize Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.6 Description Defines the image size of the system BIOS in kilobytes (KB). A zero (0) indicates that the image size of the BIOS is unknown. Syntax DellUnsigned32BitRange Access Read-only System BIOS Release Date Name Name systemBIOSReleaseDateName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.
book.book Page 100 Monday, March 14, 2011 3:01 PM Name systemBIOSStartingAddress Description Defines the starting address of the system BIOS. A zero (0) indicates that the address is unknown. Syntax DellUnsigned64BitRange Access Read-only System BIOS Ending Address Name systemBIOSEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.10 Description Defines the ending address of the system BIOS. A zero (0) indicates that the address is unknown.
book.book Page 101 Monday, March 14, 2011 3:01 PM Name systemBIOSCharacteristics Description Defines characteristics of the system BIOS. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one). Bit 63 is the first bit in the value, and bit 0 is the last bit in the value. See the description of DellUnsigned64BitRange at the beginning of this file for more information on the format of the value. Bits 48-63 need to be examined in the context of the system ID.
book.book Page 102 Monday, March 14, 2011 3:01 PM Name systemBIOSCharacteristics Description Bit Position Meaning if Set -------------- -----------------Bit 16Selectable Boot is supported Bit 17BIOS ROM is socketed Bit 18Boot From PC Card (PCMCIA) is supported Bit 19EDD (Enhanced Disk Drive) Specification is supported Bit 20Int 13h - Japanese Floppy for NEC 9800 1.2mb (3.5 in, 1k Bytes/Sector, 360 RPM) is supported Bit 21Int 13h - Japanese Floppy for Toshiba 1.2mb (3.
book.book Page 103 Monday, March 14, 2011 3:01 PM System BIOS Characteristics Ext 1 Name systemBIOSCharacteristicsExt1 Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.13 Description Defines additional characteristics of the system basic input/output system (BIOS). This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
book.book Page 104 Monday, March 14, 2011 3:01 PM Firmware Table Name firmwareTable Object ID 1.3.6.1.4.1.674.10892.1.300.60 Description Defines the Firmware Table. Syntax SEQUENCE OF FirmwareTableEntry Access Not accessible Firmware Table Entry Name firmwareTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.60.1 Description Defines the Firmware Table entry.
book.book Page 105 Monday, March 14, 2011 3:01 PM Firmware State Capabilities Name firmwareStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.3 Description Defines the capabilities of the firmware states. Syntax DellStateCapabilities Access Read-only Firmware State Capabilities Name firmwareStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.4 Description Defines the state of the firmware and allows for the setting of the firmware.
book.book Page 106 Monday, March 14, 2011 3:01 PM Firmware Type Name firmwareType Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.7 Description Defines the type of the firmware. Syntax DellFirmwareType Access Read-only Firmware Type Name Name firmwareTypeName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.8 Description Defines the name of firmware type. Syntax DellString Access Read-only Firmware Update Capabilities Name firmwareUpdateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.
book.book Page 107 Monday, March 14, 2011 3:01 PM Firmware Version Name Name firmwareVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.11 Description Defines the version name of the firmware. Syntax DellString Access Read-only Intrusion Table The following objects and attributes describe the different forms of chassis intrusion, a situation that occurs when the cover of a computer is removed. Name intrusionTable Object ID 1.3.6.1.4.1.674.10892.1.300.
book.book Page 108 Monday, March 14, 2011 3:01 PM Intrusion Index Name intrusionIndex Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.2 Description Defines the index of the intrusion objects in this subgroup. Syntax DellObjectRange Access Read-only Intrusion State Capabilities Name intrusionStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.3 Description Defines the capabilities of the intrusion object.
book.book Page 109 Monday, March 14, 2011 3:01 PM Intrusion Reading Name intrusionReading Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.6 Description Defines the reading of the intrusion object. Syntax DellIntrusionReading Access Read-only Intrusion Type Name intrusionType Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.7 Description Defines the type of the intrusion object. Syntax DellIntrusionType Access Read-only Intrusion Location Name Name intrusionLocationName Object ID 1.3.6.1.4.1.
book.book Page 110 Monday, March 14, 2011 3:01 PM Baseboard Table Entry Name baseBoardTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.80.1 Description Defines the Baseboard Table entry. Syntax BaseBoardTableEntry Access Not accessible Index baseBoardChassisIndex, baseBoardIndex Baseboard Chassis Index Name baseBoardChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.1 Description Defines the index (one-based) of the associated chassis.
book.book Page 111 Monday, March 14, 2011 3:01 PM Baseboard State Settings Name baseBoardStateSettings Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.4 Description Defines the state settings of the baseboard. Syntax DellStateSettings Access Read-write Baseboard Status Name baseBoardStatus Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.5 Description Defines the status of the baseboard. Syntax DellStatus Access Read-only Baseboard Feature Flags Name baseBoardFeatureFlags Object ID 1.3.6.1.4.1.
book.book Page 112 Monday, March 14, 2011 3:01 PM Baseboard Type Name Name baseBoardTypeName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.8 Description Defines the name of the type of baseboard. Syntax DellString Access Read-only Baseboard Location Name Name baseBoardLocationName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.9 Description Defines the location name of the baseboard. Syntax DellString Access Read-only Baseboard Manufacturer Name Name baseBoardManufacturerName Object ID 1.3.
book.book Page 113 Monday, March 14, 2011 3:01 PM Baseboard Version Name Name baseBoardVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.12 Description Defines the baseboard version name. Syntax DellString Access Read-only Baseboard Service Tag Name Name baseBoardServiceTagName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.13 Description Defines the baseboard service tag name.
book.book Page 114 Monday, March 14, 2011 3:01 PM Baseboard Express Service Code Name Name baseBoardExpressServiceCodeName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.16 Description Defines the express service code of the baseboard. Syntax DellString Access Read-only Chassis Information Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 6-1.
book.book Page 115 Monday, March 14, 2011 3:01 PM Table 6-2. Chassis Type (continued) Variable Name: DellChassisType Data Type: Integer Possible Data Values Meaning of Data Value tower(7) The chassis type is a tower. portable(8) The chassis type is a portable. lapTop(9) The chassis type is a laptop. noteBook(10) The chassis type is a notebook. handHeld(11) The chassis type is a handheld. dockingStation(12) The chassis type is a docking station. allInOne(13) The chassis type is an all-in-one.
book.book Page 116 Monday, March 14, 2011 3:01 PM Table 6-3. Connection Status Variable Name: DellConnectionStatus Data Type: Integer Possible Data Values Meaning of Data Value unknown(2) The status of the chassis connection is unknown. ok(3) The status of the chassis connection is OK. failure(4) The status of the chassis connection is failure. Table 6-4.
book.book Page 117 Monday, March 14, 2011 3:01 PM Table 6-6. Front-Panel LED Control Settings Variable Name: DellLEDControlSettings Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The LED control setting is unknown. alertOnError(2) The LED control is set to alert on an error condition. alertOnWarningAndError(4) The LED control is set to alert on an error or a warning condition. Table 6-7.
book.book Page 118 Monday, March 14, 2011 3:01 PM Table 6-8. Hard-Drive Fault LED Control Settings Variable Name: DellHDFaultLEDControlSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The LEDs do not have any fault settings capabilities. unknown(1) The hard-drive fault LEDs’ state is unknown. enabled(2) The hard-drive fault LEDs’ state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).
book.book Page 119 Monday, March 14, 2011 3:01 PM Table 6-9. Chassis Identification Control Capabilities (continued) Variable Name: DellChassisIdentifyControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value NOTE: Chassis identification capabilities allow system administrators to set front panel light-emitting diodes (LEDs) to blink when the chassis has malfunctioning components. When enabled, the blinking lights help administrators locate the problem chassis. Table 6-10.
book.book Page 120 Monday, March 14, 2011 3:01 PM Table 6-11. Host Control Capabilities Variable Name: DellHostControlCapabilities NOTE: An operator can manually enable these actions using SNMP. Data Type: Integer Possible Data Values Meaning of Data Value manualRebootCapable(1) The operator can reboot capable host. manualPowerOFFCapable(2) The operator can power off capable host. manualPowerCycleCapable(4) The operator can power-cycle capable host.
book.book Page 121 Monday, March 14, 2011 3:01 PM Table 6-12. Host Control Settings Variable Name: DellHostControlSettings NOTE: An operator can manually cause these actions using SNMP. Data Type: Integer Possible Data Values Meaning of Data Value manualReboot(1) The operator can reboot the host. manualPowerOFF(2) The operator can power off the host. manualPowerCycle(4) Power cycle the host. manualOperatingSystemShutdown(8) The operator can shut down the operating system on the host.
book.book Page 122 Monday, March 14, 2011 3:01 PM Table 6-13. Watchdog Control Capabilities (continued) Variable Name: DellWatchDogControlCapabilities NOTE: When the system determines that the operating system is not responding, it automatically performs the selected action without operator intervention.
book.book Page 123 Monday, March 14, 2011 3:01 PM Table 6-15. Watchdog Timer Capabilities Variable Name: DellWatchDogTimerCapabilities Data Type: Integer Possible Data Values Meaning of Data Value type1Capable(1) Watchdog timer can time in intervals from 20–480 seconds. type2Capable(2) Watchdog timer can time in 30-, 60-, 120-, and 480-second intervals. type3Capable(4) Watchdog timer can time in 60-second intervals. Table 6-16.
book.book Page 124 Monday, March 14, 2011 3:01 PM Table 6-18. NMI Button Control Capabilities Variable Name: DellNMIButtonControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The NMI button has no capabilities. unknownCapabilities(1) The NMI button capabilities are unknown. The NMI button can be enabled (online) or disabled (offline). enableCapable(2) Table 6-19.
book.book Page 125 Monday, March 14, 2011 3:01 PM Table 6-21. Chassis System Class Variable Name: DellChassisSystemClass Data Type: Integer Possible Data Values Meaning of Data Value other(1) The chassis system class is not one of the following: unknown(2) The chassis system class is unknown. workstationClass(3) The chassis system class is a workstation. serverClass(4) The chassis system class is a server. desktopClass(5) The chassis system class is a desktop.
book.book Page 126 Monday, March 14, 2011 3:01 PM Table 6-22. Firmware Type (continued) Variable Name: DellFirmwareType Data Type: Integer Possible Data Values Meaning of Data Value frontPanel(9) The firmware type is Front Panel Controller. baseboardManagementController (10) The firmware type is Baseboard Management Controller. hotPlugPCI(11) The firmware type is Hot Plug Peripheral Component Interconnect (PCI) Controller. sensorData(12) The firmware type is Sensor Data Records.
book.book Page 127 Monday, March 14, 2011 3:01 PM Table 6-23. Baseboard Type Variable Name: DellBaseBoardType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The baseboard type is unknown. other(2) The baseboard type is not one of the following types. serverBlade(3) The baseboard type is a server blade. connectivitySwitch(4) The baseboard type is a connectivity switch. systemManagementModule(5) The baseboard type is a system management module.
book.book Page 128 Monday, March 14, 2011 3:01 PM Table 6-24. Baseboard Feature Flags Variable Name: DellBaseBoardFeatureFlags Data Type: Integer Possible Data Values Meaning of Data Value boardRequiresDaughterBoard This baseboard requires at least one (2) daughter board or auxiliary card. boardIsRemovable(4) This baseboard is removable. boardIsReplaceable(8) This baseboard is replaceable. boardIsHotSwappable(16) This baseboard is hot swappable.
book.book Page 129 Monday, March 14, 2011 3:01 PM Operating System Group 7 The Operating System Group provides status and identifying information about a system’s operating system. Identifying information includes the name, version, service pack, and patch level of the installed operating system.
book.book Page 130 Monday, March 14, 2011 3:01 PM Operating System Chassis Index Name operatingSystemchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Operating System State Capabilities Name operatingSystemStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.2 Description Defines the capabilities of the operating system.
book.book Page 131 Monday, March 14, 2011 3:01 PM Operating System Is Primary Name operatingSystemIsPrimary Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.5 Description Specifies whether this operating system is the primary operating system. Syntax DellBoolean Access Read-only Operating System Name Name operatingSystemOperatingSystemName Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.6 Description Defines the name of the operating system running on the system. Syntax DisplayString (SIZE (0..
book.book Page 132 Monday, March 14, 2011 3:01 PM Operating System Memory Table Entry Name operatingSystemTableEntry Object ID 1.3.6.1.4.1.674.10892.1.400.20.1 Description Defines the Operating System Memory Table entry. Syntax OperatingSystemMemoryTableEntry Access Not accessible Index operatingSystemMemorychassisIndex Operating System Memory Chassis Index Name operatingSystemMemorychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.
book.book Page 133 Monday, March 14, 2011 3:01 PM Operating System Memory Status Name operatingSystemMemoryStatus Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.4 Description Defines the status of the operating system memory. Syntax DellStatus Access Read-only Operating System Memory Total Physical Size Name operatingSystemMemoryTotalPhysicalSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.5 Description Defines the total physical memory size in kilobytes.
book.book Page 134 Monday, March 14, 2011 3:01 PM Operating System Memory Available Page File Size Name operatingSystemMemoryAvailablePageFileSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.8 Description Defines the available page file memory size in kilobytes. Syntax DellUnsigned32BitRange Access Read-only Operating System Memory Total Virtual Size Name operatingSystemMemoryTotalVirtualSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.
book.book Page 135 Monday, March 14, 2011 3:01 PM System Resource Group 8 The Management Information Base (MIB) variables presented in this section enable you to track various attributes of your system resources. This section includes "System Resource Group Tables" on page 135 that track variables such as the owner, ports, system memory, interrupts, and direct memory access.
book.book Page 136 Monday, March 14, 2011 3:01 PM System Resource Map Table Entry Name systemResourceMapTableEntry Object ID 1.3.6.1.4.1.674.10892.1.500.10.1 Description Defines the System Resource Map Table entry. Syntax SystemResourceMapTableEntry Access Not accessible Index systemResourceMapchassisIndex, systemResourceMapIndex System Resource Map Chassis Index Name systemResourceMapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.
book.book Page 137 Monday, March 14, 2011 3:01 PM System Resource Map State Settings Name systemResourceMapStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.4 Description Defines the state and allows the setting of this system map. Syntax DellStateSettings Access Read-write System Resource Map Status Name systemResourceMapStatus Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.5 Description Defines the status of this system map.
book.book Page 138 Monday, March 14, 2011 3:01 PM System Resource Owner Table Entry Name systemResourceOwnerTable Object ID 1.3.6.1.4.1.674.10892.1.500.20.1 Description Defines the System Resource Owner Table entry. Variables in this group reference the System Resource Map index. Syntax SystemResourceOwnerTableEntry Access Not accessible Index systemResourceOwnerchassisIndex, systemResourceOwnerIndex System Resource Owner Chassis Index Name systemResourceOwnerchassisIndex Object ID 1.3.6.1.
book.book Page 139 Monday, March 14, 2011 3:01 PM System Resource Owner State Settings Name systemResourceOwnerStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.4 Description Defines the state settings of this system resource owner. Syntax DellStateSettings Access Read-write System Resource Owner Status Name systemResourceOwnerStatus Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.5 Description Defines the status of this system resource owner.
book.book Page 140 Monday, March 14, 2011 3:01 PM System Resource Owner Description Name Name systemResourceOwnerDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.8 Description Defines the description name of the system resource owner. Syntax DellString Access Read-only System Resource Owner Interface Instance Name systemResourceOwnerInterfaceInstance Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.
book.book Page 141 Monday, March 14, 2011 3:01 PM System Resource I/O Port Chassis Index Name systemResourceIOPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System Resource I/O Port Index Name systemResourceIOPortIndex Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.2 Description Defines the index (one-based) of the system resource I/O ports in this chassis.
book.book Page 142 Monday, March 14, 2011 3:01 PM System Resource I/O Port Status Name systemResourceIOPortStatus Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.5 Description Defines the status of the system resource I/O port. Syntax DellStateSettings Access Read-only System Resource I/O Port Owner Index Reference Name systemResourceIOPortOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.6 Description Defines the index to the associated system resource owner in this chassis.
book.book Page 143 Monday, March 14, 2011 3:01 PM System Resource I/O Port Ending Address Name systemResourceIOPortEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.9 Description Defines the 64 bits of the ending address of the system resource I/O port. Syntax DellUnsigned64BitRange Access Read-only System Resource Memory Table Name systemResourceMemoryTable Object ID 1.3.6.1.4.1.674.10892.1.500.40 Description Defines the System Resource Memory Table.
book.book Page 144 Monday, March 14, 2011 3:01 PM System Resource Memory Index Name systemResourceMemoryIndex Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.2 Description Defines the index of system resource memory in this chassis. Syntax DellObjectRange Access Read-only System Resource Memory State Capabilities Name systemResourceMemoryStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.3 Description Defines the capabilities of this system resource memory.
book.book Page 145 Monday, March 14, 2011 3:01 PM System Resource Memory Owner Index Reference Name systemResourceMemoryOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.6 Description Defines the index to the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only System Resource Memory Share Disposition Name systemResourceMemoryShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.
book.book Page 146 Monday, March 14, 2011 3:01 PM System Resource Memory Flags Name systemResourceMemoryFlags Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.10 Description Defines the permission flags for the system resource memory. Syntax DellResourceMemoryFlags (See Table 8-4) Access Read-only System Resource Interrupt Table Name systemResourceInterruptTable Object ID 1.3.6.1.4.1.674.10892.1.500.50 Description Defines the System Resource Interrupt Table.
book.book Page 147 Monday, March 14, 2011 3:01 PM System Resource Interrupt Index Name systemResourceInterruptIndex Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.2 Description Defines the index (one-based) of this interrupt resource. Syntax DellObjectRange Access Read-only System Resource Interrupt State Capabilities Name systemResourceInterruptStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.3 Description Defines the capabilities of this system resource interrupt.
book.book Page 148 Monday, March 14, 2011 3:01 PM System Resource Interrupt Owner Index Reference Name systemResourceInterruptOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.6 Description Defines the index for the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only System Resource Interrupt Owner Share Disposition Name systemResourceInterruptShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.
book.book Page 149 Monday, March 14, 2011 3:01 PM System Resource Interrupt Trigger Name systemResourceInterruptTrigger Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.10 Description Defines the interrupt trigger of the system resource interrupt. Syntax DellResourceInterruptTrigger (See Table 8-6) Access Read-only System Resource Direct Memory Access (DMA) Table Name systemResourceDMATable Object ID 1.3.6.1.4.1.674.10892.1.500.60 Description Defines the System Resource DMA Table.
book.book Page 150 Monday, March 14, 2011 3:01 PM System Resource DMA Index Name systemResourceDMAIndex Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.2 Description Defines the index of system resource DMAs in this chassis. Syntax DellObjectRange Access Read-only System Resource DMA State Capabilities Name systemResourceDMAStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.3 Description Defines the capabilities of this system resource DMA.
book.book Page 151 Monday, March 14, 2011 3:01 PM System Resource DMA Owner Index Reference Name systemResourceDMAOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.6 Description Defines the index to the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only System Resource DMA Share Disposition Name systemResourceDMAShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.
book.book Page 152 Monday, March 14, 2011 3:01 PM System Resource DMA Bus Master Name systemResourceDMABusMaster Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.10 Description Defines the bus mastering capabilities of the system resource DMA. Syntax DellResourceDMABusMaster (See Table 8-7) Access Read-only System Resource Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 8-1.
book.book Page 153 Monday, March 14, 2011 3:01 PM Table 8-2. Resource Owner Interface Type (continued) Variable Name: DellResourceOwnerInterfaceType Data Type: Integer Possible Data Values Meaning of Data Value typeIsEISA(5) The interface type is an Extended Industry Standard Architecture (EISA) bus. typeIsMCA(6) The interface type is a microchannel architecture (MCA) bus. typeIsTurboChannel(7) The interface type is a turbo-channel bus. Table 8-3.
book.book Page 154 Monday, March 14, 2011 3:01 PM Table 8-5. Resource Interrupt Type Variable Name: DellResourceInterruptType Data Type: Integer Possible Data Values Meaning of Data Value interruptIsLevelSensitive(1) The interrupt type is level sensitive. The interrupt type is latched. interruptIsLatched(2) Table 8-6.
book.book Page 155 Monday, March 14, 2011 3:01 PM Table 8-8. Resource DMA Transfer Width Variable Name: DellResourceDMATransferWidth Data Type: Integer Possible Data Values Meaning of Data Value dmaTransferWidthIsOther(1) The DMA transfer width is not one of the following: dmaTransferWidthIsunknown(2) The DMA transfer width is unknown. dmaTransferWidthIs8Bits(3) The DMA transfer width is 8 bits. dmaTransferWidthIs16Bits(4) The DMA transfer width is 16 bits.
book.
book.book Page 157 Monday, March 14, 2011 3:01 PM 9 Power Group The Power Group provides information about power units (a group of power supplies in a system chassis), power supplies, and voltage and amperage probes. NOTE: Power Management features are only available for PowerEdge systems that have hot-swappable power supplies and not systems that have a fixed, nonredundant power supply installed.
book.book Page 158 Monday, March 14, 2011 3:01 PM Power Unit Table Entry Name powerUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.10.1 Description Defines the Power Unit Table entry. Syntax DellObjectRange Access Read-only Index powerUnitchassisIndex, powerUnitIndex Power Unit Chassis Index Name powerUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 159 Monday, March 14, 2011 3:01 PM Power Unit State Settings Name powerUnitStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.4 Description Defines the state and settings of the power unit. Syntax DellStateSettings Access Read-write Power Unit Redundancy Status Name powerUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.5 Description Defines the redundancy status of the power unit.
book.book Page 160 Monday, March 14, 2011 3:01 PM Power Unit Status Name powerUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.8 Description Defines the status of the power unit in this chassis. Syntax DellStatus Access Read-only Power Supply Table Name powerSupplyTable Object ID 1.3.6.1.4.1.674.10892.1.600.12 Description Defines the Power Supply Table. Syntax PowerSupplyTableEntry Access Not accessible Power Supply Table Entry Name powerSupplyTableEntry Object ID 1.3.6.1.4.1.
book.book Page 161 Monday, March 14, 2011 3:01 PM Power Supply Index Name powerSupplyIndex Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.2 Description Defines the index of power supply. Syntax DellObjectRange Access Read-only Power Supply State Capabilities Unique Name powerSupplyStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.3 Description Defines the capabilities of the power supply.
book.book Page 162 Monday, March 14, 2011 3:01 PM Power Supply Output Watts Name powerSupplyOutputWatts Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.6 Description Defines the maximum sustained output wattage of the power supply in tenths of watts. Syntax DellSigned32BitRange Access Read-only Power Supply Type Name powerSupplyType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.7 Description Defines the type of power supply.
book.book Page 163 Monday, March 14, 2011 3:01 PM Power Supply Power Unit Index Reference Name powerSupplypowerUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.10 Description Defines the index to the associated system power unit in this chassis. Syntax DellObjectRange Access Read-only Power Supply Sensor State Name powerSupplySensorState Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.
book.book Page 164 Monday, March 14, 2011 3:01 PM Power Supply Rated Input Wattage Name powerSupplyRatedInputWattage Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.14 Description Defines the rated input wattage of the power supply (in tenths of Watts.) Syntax DellSigned32BitRange Access Read-only Voltage Probe Table Name voltageProbeTable Object ID 1.3.6.1.4.1.674.10892.1.600.20 Description Defines the Voltage Probe Table.
book.book Page 165 Monday, March 14, 2011 3:01 PM Voltage Probe Index Name voltageProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.2 Description Defines the index of voltage probes in this chassis. Syntax DellObjectRange Access Read-only Voltage Probe State Capabilities Name voltageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.3 Description Defines the capabilities of the voltage probe.
book.book Page 166 Monday, March 14, 2011 3:01 PM Voltage Probe Reading Name voltageProbeReading Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.6 Description Defines the value of the voltage probe reading. The value is an integer representing the voltage in millivolts that the probe is reading. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, a value is not returned for this attribute.
book.book Page 167 Monday, March 14, 2011 3:01 PM Name voltageProbeUpperNonRecoverableThreshold Access Read-only Voltage Probe Upper Critical Threshold Name voltageProbeUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.10 Description Defines the value of the voltage probe’s upper critical threshold. Syntax DellSigned32BitRange Access Read-only Voltage Probe Upper Noncritical Threshold Name voltageProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.
book.book Page 168 Monday, March 14, 2011 3:01 PM Voltage Probe Lower Critical Threshold Name voltageProbeLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.13 Description Defines the value of the voltage probe’s lower critical threshold. Syntax DellSigned32BitRange Access Read-only Voltage Probe Lower Nonrecoverable Threshold Name voltageProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.
book.book Page 169 Monday, March 14, 2011 3:01 PM Voltage Probe Discrete Reading Name voltageProbeDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.16 Description Defines the reading for a voltage probe of type voltageProbeTypeIsDiscrete. When the value for voltageProbeType is other than voltageProbeTypeIsDiscrete, a value is not returned for this attribute.
book.book Page 170 Monday, March 14, 2011 3:01 PM Amperage Probe Chassis Index Name amperageProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Amperage Probe Index Name amperageProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.2 Description Defines the index of amperage probes in this chassis.
book.book Page 171 Monday, March 14, 2011 3:01 PM Amperage Probe Status Name amperageProbeStatus Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.5 Description Defines the status of the amperage probe. Syntax DellSigned32BitRange Access Read-only Amperage Probe Reading Name amperageProbeReading Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.6 Description Defines the reading for an amperage probe of type other than amperageProbeTypeIsDiscrete.
book.book Page 172 Monday, March 14, 2011 3:01 PM Amperage Probe Type Name amperageProbeType Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.7 Description Defines the type of the amperage probe. Syntax DellAmperageProbeType Access Read-only Amperage Probe Location Name Name amperageProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.8 Description Defines the location name of the amperage probe in this chassis.
book.book Page 173 Monday, March 14, 2011 3:01 PM Amperage Probe Upper Noncritical Threshold Name amperageProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.11 Description Defines the user-assigned value of the amperage probe’s upper critical threshold. Syntax DellSigned32BitRange Access Read-write Amperage Probe Lower Noncritical Threshold Name amperageProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.
book.book Page 174 Monday, March 14, 2011 3:01 PM Amperage Probe Lower Nonrecoverable Threshold Name amperageProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.14 Description Defines the value of the amperage probe’s lower nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Amperage Probe Probe Capabilities Name amperageProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.
book.book Page 175 Monday, March 14, 2011 3:01 PM AC Power Switch Table Name aCPowerSwitchTable Object ID 1.3.6.1.4.1.674.10892.1.600.40 Description Defines the AC Power Switch Table. Syntax SEQUENCE OF ACPowerSwitchTableEntry Access Not accessible AC Power Switch Table Entry Name aCPowerSwitchTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.40.1 Description Defines the AC Power Switch Table entry.
book.book Page 176 Monday, March 14, 2011 3:01 PM AC Power Switch Capabilities Name aCPowerSwitchCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.3 Description Defines the capabilities of this AC power switch. Syntax DellACPowerSwitchCapabilities Access Read-only AC Power Switch Settings Name aCPowerSwitchSettings Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.4 Description Defines the settings of this AC power switch.
book.book Page 177 Monday, March 14, 2011 3:01 PM AC Power Switch Name Name aCPowerSwitchName Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.7 Description Defines the name of this AC power switch. Syntax DellString Access Read-only AC Power Switch Redundancy Mode Name aCPowerSwitchRedundancyMode Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.8 Description Defines the redundancy mode of this AC power switch.
book.book Page 178 Monday, March 14, 2011 3:01 PM AC Power Cord Table Entry Name aCPowerCordTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.42.1 Description Defines the AC Power Cord Table entry. Syntax ACPowerCordTableEntry Access Not accessible Index aCPowerCordchassisIndex, aCPowerCordIndex AC Power Cord Chassis Index Name aCPowerCordChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.1 Description Defines the index (one-based) of the chassis containing this AC power cord.
book.book Page 179 Monday, March 14, 2011 3:01 PM AC Power Cord State Settings Name aCPowerCordStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.4 Description Defines the settings of this AC power cord. Syntax DellACPowerCordStateSettings Access Read-write AC Power Cord Status Name aCPowerCordStatus Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.5 Description Defines the status of this AC power cord.
book.book Page 180 Monday, March 14, 2011 3:01 PM Battery Table Name batteryTable Object ID 1.3.6.1.4.1.674.10892.1.600.50 Description Defines the Battery Table. Syntax SEQUENCE OF BatteryTableEntry Access Not accessible Battery Table Entry Name batteryTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.50.1 Description Defines the Battery Table Entry.
book.book Page 181 Monday, March 14, 2011 3:01 PM Battery State Capabilities Name batteryStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.3 Description Defines the state capabilities of the battery. Syntax DellStateCapabilities Access Read-only Battery State Settings Name batteryStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.4 Description Defines the state settings of the battery.
book.book Page 182 Monday, March 14, 2011 3:01 PM Battery Location Name Name batteryLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.7 Description Defines the location of the battery. Syntax DellString Access Read-only Power Usage Table Name powerUsageTable Object ID 1.3.6.1.4.1.674.10892.1.600.60 Description Defines the Power Usage Table. Syntax SEQUENCE OF PowerUsageTableEntry Access Not accessible Power Usage Table Entry Name powerUsageTableEntry Object ID 1.3.6.1.4.1.674.
book.book Page 183 Monday, March 14, 2011 3:01 PM Power Usage Index Name powerUsageIndex Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.2 Description Defines the index (one-based) of the power usage information. Syntax DellObjectRange Access Read-only Power Usage State Capabilities Name powerUsageStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.3 Description Defines the state capabilities of the power usage information.
book.book Page 184 Monday, March 14, 2011 3:01 PM Power Usage Entity Name Name powerUsageEntityName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.6 Description Defines the name of the entity associated with this power usage information. Syntax DellString Access Read-only Power Usage Cumulative Wattage Name powerUsageCumulativeWattage Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
book.book Page 185 Monday, March 14, 2011 3:01 PM Name powerUsagePeakWatts Description Defines the peak wattage reading (in Watts) for this entity since the date and time specified by the powerUsagePeakWattsStartDateName attribute. Syntax DellUnsigned32BitRange Access Read-only Power Usage Peak Watts Start Date Name Name powerUsagePeakWattsStartDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
book.book Page 186 Monday, March 14, 2011 3:01 PM Power Usage Peak Amps Start Date Name Name powerUsagePeakAmpsStartDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.13 Description Defines the date and time at which the data collection started for the value reported by the powerUsagePeakAmps attribute. Syntax DellDateName Access Read-only Power Usage Peak Amps Reading Date Name Name powerUsagePeakAmpsReadingDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
book.book Page 187 Monday, March 14, 2011 3:01 PM Name powerUsageMaxPotentialPower Description Defines the maximum potential power (in Watts) of the system. This is the maximum power the system can consume based on the current hardware configuration. Syntax DellUnsigned32BitRange Access Read-only Power Usage Power Cap Capabilities Name powerUsagePowerCapCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.17 Description Defines the system power cap capabilities.
book.book Page 188 Monday, March 14, 2011 3:01 PM Power Usage Instantaneous Headroom Name powerUsageInstantaneousHeadroom Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.20 Description Defines the system instantaneous headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus instantaneous power draw. Syntax DellUnsigned32BitRange Access Read-only Power Usage Peak Headroom Name powerUsagePeakHeadroom Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
book.book Page 189 Monday, March 14, 2011 3:01 PM Name powerProfileTableEntry Access Not accessible Index powerProfileChassisIndex, powerProfileIndex Power Profile Chassis Index Name powerProfileChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Power Profile Index Name powerProfileIndex Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.
book.book Page 190 Monday, March 14, 2011 3:01 PM Name powerProfileSetting Syntax DellPowerProfileType Access Read-only Power Profile Custom CPU Management Capabilities Name powerProfileCustomCPUManagementCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.5 Description Defines the custom CPU power and performance management capabilities that are available for the Custom power profile.
book.book Page 191 Monday, March 14, 2011 3:01 PM Power Profile Custom Memory Management Setting Name powerProfileCustomMemoryManagementSetting Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.8 Description Defines the custom memory power and performance management setting for the Custom power profile. Syntax DellMemoryPowerPerformanceManagementType Access Read-only Power Profile Custom Fan Management Capabilities Name powerProfileCustomFanManagementCapabilities Object ID 1.3.6.1.4.1.674.10892.1.
book.book Page 192 Monday, March 14, 2011 3:01 PM Table 9-1. Power Supply State Capabilities Unique Variable Name: DellPowerSupplyStateCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The power supply’s capabilities are unknown. onlineCapable(2) The power supply can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The power supply’s capabilities are not ready. Table 9-2.
book.book Page 193 Monday, March 14, 2011 3:01 PM Table 9-2. Power Supply State Settings Unique (continued) Variable Name: DellPowerSupplyStateSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value onlineAndPredictiveFail The power supply is online and indicating that it ure(210) has a problem. acPowerAndSwitchAreOn The power supply is online and OK. PowerSupplyIsOnIsOkAnd Online(242) Table 9-3.
book.book Page 194 Monday, March 14, 2011 3:01 PM Table 9-3. Power Supply Type Definitions (continued) Variable Name: DellPowerSupplyType Data Type: Integer Possible Data Values Meaning of Data Value powerSupplyTypeIsDC(10) The power supply type is a DC power supply. powerSupplyTypeIsVRM(11) The power supply type is a voltage regulator module (VRM) power supply. Table 9-4.
book.book Page 195 Monday, March 14, 2011 3:01 PM Table 9-5. Power Supply Configuration Error Type Variable Name: DellPowerSupplyConfigurationErrorType Data Type: Integer Possible Data Values Meaning of Data Value vendorMismatch(1) The power supply configuration error type is vendor mismatch. revisionMismatch(2) The power supply configuration error type is revision mismatch. processorMissing(3) The power supply configuration error type is processor missing. Table 9-6.
book.book Page 196 Monday, March 14, 2011 3:01 PM Table 9-6. Voltage Probe Type (continued) Variable Name: DellVoltageType Data Type: Integer Possible Data Values Meaning of Data Value voltageProbeTypeIsCore(10) The voltage probe type is a core volt probe. voltageProbeTypeIsFLEA(11) The voltage probe type is a FLEA (standby) volt probe. voltageProbeTypeIsBattery(12) The voltage probe type is a battery volt probe.
book.book Page 197 Monday, March 14, 2011 3:01 PM Table 9-8. Amperage Probe Definitions Variable Name: DellAmperageType Data Type: Integer Possible Data Values Meaning of Data Value amperageProbeTypeIsOther(1) The amperage probe type is not one of the following: amperageProbeTypeIsUnknown(2) The amperage probe type is unknown (not known or not monitored). amperageProbeTypeIs1Point5Volt(3) The amperage probe type is a 1.5-ampere (A) probe.
book.book Page 198 Monday, March 14, 2011 3:01 PM Table 9-8. Amperage Probe Definitions (continued) Variable Name: DellAmperageType Data Type: Integer Possible Data Values Meaning of Data Value amperageProbeTypeIs2Point5Volt(14) The amperage probe type is a 2.5-V amperage probe. amperageProbeTypeIsGTL(15) The amperage probe type is a Gunning Transceiver Logic (GTL) probe. amperageProbeTypeIsDiscrete(16) The amperage probe type is an amperage probe with discrete reading.
book.book Page 199 Monday, March 14, 2011 3:01 PM Table 9-10. AC Power Switch Capabilities Variable Name: DellACPowerSwitchCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknownCapabilities(1) The AC power switch’s capabilities are unknown. inputSourceCord1NoReturnCapable(2) Input source is AC power cord 1, with no return. inputSourceCord1ReturnCapable(4) Input source is AC power cord 1, with return.
book.book Page 200 Monday, March 14, 2011 3:01 PM Table 9-12. AC Power Switch Redundancy Mode Variable Name: DellACPowerSwitchRedundancyMode Data Type: Integer Possible Data Values Meaning of Data Value nonRedundant(1) The AC power switch is not expecting redundancy. redundant(2) The AC power switch is expecting redundancy. Table 9-13.
book.book Page 201 Monday, March 14, 2011 3:01 PM Table 9-15. Battery Reading Variable Name: DellBatteryReading Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value predictiveFailure(1) Battery sensor detects predictive failure. failed(2) Battery has failed. presenceDetected(4) Battery presence is detected. Table 9-16.
book.book Page 202 Monday, March 14, 2011 3:01 PM Table 9-18. Power Profile Type Variable Name: DellPowerProfileType Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) Power profile type is Maximum Performance. osControl(2) Power profile type is OS control. activePowerController(4) Power profile type is Active Power Controller. custom(8) Power profile type is Custom. Table 9-19.
book.book Page 203 Monday, March 14, 2011 3:01 PM Table 9-20. Memory Power Performance Management Type Variable Name: DellMemoryPowerPerformanceManagementType Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) Memory power and performance management type is Maximum Performance. mhz1333(2) Memory power and performance is 1333 MHz. mhz1067(4) Memory power and performance is 1067 MHz.
book.
book.book Page 205 Monday, March 14, 2011 3:01 PM 10 Thermal Group The Thermal Group provides information about cooling units, cooling devices, and temperature probes. Cooling units are sets of fans or other cooling devices in a system chassis. Thermal Group variables include threshold values and types of cooling devices and temperature probes.
book.book Page 206 Monday, March 14, 2011 3:01 PM Cooling Unit Chassis Index Name coolingUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.1 Description Defines the index (one-based) of this chassis. Syntax TableEntry Access Read-only Cooling Unit Index Name coolingUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.2 Description Defines the index (one-based) of cooling units.
book.book Page 207 Monday, March 14, 2011 3:01 PM Cooling Unit Redundancy Status Name coolingUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.5 Description Defines the redundancy status of the cooling unit. Syntax DellStatusRedundancy Access Read-only Cooling Device Count For Redundancy Name coolingDeviceCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.6 Description Defines the total number of cooling devices required for this cooling unit to have redundancy.
book.book Page 208 Monday, March 14, 2011 3:01 PM Cooling Device Table Name coolingDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.700.12 Description Defines the Cooling Device Table. Syntax CoolingDeviceTableEntry Access Not accessible Cooling Device Table Entry Name coolingDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.12.1 Description Defines the Cooling Device Table entry.
book.book Page 209 Monday, March 14, 2011 3:01 PM Cooling Device State Capabilities Name coolingDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.3 Description Defines the capabilities of the cooling device. Syntax DellStateCapabilities Access Read-only Cooling Device State Settings Name coolingDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.4 Description Defines the state and settings of the cooling device.
book.book Page 210 Monday, March 14, 2011 3:01 PM Cooling Device Reading Name coolingDeviceReading Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.6 Description Defines either the cooling device’s speed in revolutions per minute (RPM), or the off/on value of the fan. When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the speed in RPM or the OFF/ON value of the cooling device.
book.book Page 211 Monday, March 14, 2011 3:01 PM Cooling Device Upper Nonrecoverable Threshold Name coolingDeviceUppernonrecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.9 Description Defines the value of the fan’s upper nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Cooling Device Upper Critical Threshold Name coolingDeviceUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.
book.book Page 212 Monday, March 14, 2011 3:01 PM Cooling Device Lower Critical Threshold Name coolingDeviceLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.13 Description Defines the value of the fan’s lower critical threshold. Syntax DellSigned32BitRange Access Read-only Cooling Device Lower Nonrecoverable Threshold Name coolingDeviceLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.
book.book Page 213 Monday, March 14, 2011 3:01 PM Cooling Device Probe Capabilities Name coolingDeviceProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.17 Description Defines the probe capabilities of the cooling device. Syntax DellProbeCapabilities Access Read-only Cooling Device Discrete Reading Name coolingDeviceDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.18 Description Defines the reading for a voltage probe of type coolingDeviceSubTypeIsDiscrete.
book.book Page 214 Monday, March 14, 2011 3:01 PM Temperature Probe Table Entry Name temperatureProbeTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.20.1 Description Defines the Temperature Probe Table entry. Syntax TemperatureProbeTableEntry Access Not accessible Index temperatureProbechassisIndex, temperatureProbeIndex Temperature Probe Chassis Index Name temperatureProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 215 Monday, March 14, 2011 3:01 PM Temperature Probe State Settings Name temperatureProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.4 Description Defines the state and settings of the temperature probe. Syntax DellStateSettings Access Read-write Temperature Probe Status Name temperatureProbeStatus Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.5 Description Defines the status of the temperature probe in tenths of degrees Celsius.
book.book Page 216 Monday, March 14, 2011 3:01 PM Temperature Probe Type Name temperatureProbeType Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.7 Description Defines the temperature probe type. Syntax DellTemperatureProbeType (See Table 10-4) Access Read-only Temperature Probe Location Name Name temperatureProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.8 Description Defines the location of the temperature probe in this chassis.
book.book Page 217 Monday, March 14, 2011 3:01 PM Temperature Probe Upper Noncritical Threshold Name temperatureProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.11 Description Defines the user-assigned value of the temperature probe’s upper noncritical threshold. Syntax DellSigned32BitRange Access Read-write Temperature Probe Lower Noncritical Threshold Name temperatureProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
book.book Page 218 Monday, March 14, 2011 3:01 PM Temperature Probe Probe Capabilities Name temperatureProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.15 Description Defines the probe capabilities of the temperature probe. Syntax DellProbeCapabilities Access Read-only Temperature Probe Discrete Reading Name temperatureProbeDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
book.book Page 219 Monday, March 14, 2011 3:01 PM Thermal Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 10-1. Cooling Device Type Variable Name: DellCoolingDeviceType Data Type: Integer Possible Data Values Meaning of Data Value coolingDeviceTypeIsOther(1) The cooling device type is not one of the following: coolingDeviceTypeIsUnknown(2) The cooling device type is unknown (not known or not monitored).
book.book Page 220 Monday, March 14, 2011 3:01 PM Table 10-2. Cooling Device Subtype Variable Name: DellCoolingDeviceSubType Data Type: Integer Possible Data Values Meaning of Data Value coolingDeviceSubTypeIsOther(1) The cooling device subtype is not one of the following: coolingDeviceSubTypeIsUnknown(2) The cooling device subtype is unknown (not known or not monitored). coolingDeviceSubTypeIsAFanThatReads The cooling device subtype is a InRPM(3) fan that reads in RPMs.
book.book Page 221 Monday, March 14, 2011 3:01 PM Table 10-4. Temperature Probe Type Variable Name: DellTemperatureProbeType Data Type: Integer Possible Data Values Meaning of Data Value temperatureProbeTypeIsOther(1) The temperature probe subtype is not one of the following: temperatureProbeTypeIsUnknown(2) The temperature probe subtype is unknown (not known or not monitored). temperatureProbeTypeIsAmbientESM(3) The temperature probe is for ambient Embedded Systems Management (ESM).
book.
book.book Page 223 Monday, March 14, 2011 3:01 PM 11 User Security Group The User Security Table defines the objects that allow administrators to create and modify user accounts and to control which users can perform Set operations on managed systems. User Security Group Table The User Security Group defines objects in the User Security MIB table. User Security Table The following object sets up the User Security Table: Name userSecurityTable Object ID 1.3.6.1.4.1.674.10892.1.
book.book Page 224 Monday, March 14, 2011 3:01 PM User Security Chassis Index Name userSecuritychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.800.1.1 Description Defines the user security index (one-based) of this chassis. Syntax DellObjectRange Access Read-only User Security Index Name userSecurityIndex Object ID 1.3.6.1.4.1.674.10892.1.800.1.2 Description Defines the user security index.
book.book Page 225 Monday, March 14, 2011 3:01 PM User Security Request Name Name userSecurityRequestName Object ID 1.3.6.1.4.1.674.10892.1.800.1.5 Description Defines a request name used for creating, deleting, and editing users.
book.
book.book Page 227 Monday, March 14, 2011 3:01 PM Remote Flash BIOS Group 12 The Remote Flash Basic Input/Output System (BIOS) Table defines the variables used to remotely update the BIOS in a system. The variables also define the capabilities of BIOS updates on the system. Remote Flash BIOS Group Table The Remote Flash BIOS Group defines objects in the Remote Flash BIOS MIB table.
book.book Page 228 Monday, March 14, 2011 3:01 PM Remote Flash BIOS Chassis Index Name remoteFlashBIOSchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Remote Flash BIOS Index Name remoteFlashBIOSIndex Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.2 Description Defines the index to the remote BIOS update hardware on this system.
book.book Page 229 Monday, March 14, 2011 3:01 PM Remote Flash BIOS Status Name remoteFlashBIOSStatus Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.5 Description Defines the status of the remote BIOS update hardware on this system. Syntax DellRemoteFlashBIOSStateStatus Access Read-only Remote Flash BIOS Last BIOS Date Name Name remoteFlashBIOSLastBIOSDateName Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.6 Description Defines the date of the last BIOS update.
book.book Page 230 Monday, March 14, 2011 3:01 PM Remote Flash BIOS Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 12-1. Remote Flash BIOS State Capabilities Unique Variable Name: DellRemoteFlashBIOSStateCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The remote flash BIOS’s capabilities are unknown.
book.book Page 231 Monday, March 14, 2011 3:01 PM Table 12-3. Remote Flash BIOS Completion Code Variable Name: DellRemoteFlashBIOSCompletionCode Data Type: Integer Possible Data Values Meaning of Data Value completionCodeIsOther(1) The completion code status is not one of the following: completionCodeIsUnknown(2) The completion code is unknown (not known or not monitored). completionCodeIsOK(3) This completion code completed successfully.
book.
book.book Page 233 Monday, March 14, 2011 3:01 PM 13 Port Group The Port Group provides information about the different types of ports that may be present in your system. This management information base (MIB) group also provides information about the capabilities, states, and settings that are possible for each port.
book.book Page 234 Monday, March 14, 2011 3:01 PM Pointing Port Table Entry Name pointingPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1 Description Defines the Pointing Port Table entry. Syntax PointingPortTableEntry Access Not accessible Index pointingPortchassisIndex, pointingPortIndex Pointing Port Chassis Index Name pointingPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 235 Monday, March 14, 2011 3:01 PM Pointing Port State Settings Name pointingPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.10.4 Description Defines the state and settings of the pointing port. Syntax DellStateSettings Access Read-write Pointing Port Status Name pointingPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.10.5 Description Defines the status of the pointing port.
book.book Page 236 Monday, March 14, 2011 3:01 PM Pointing Port Name Name pointingPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.10.8 Description Defines the name of the pointing port. Syntax DellString Access Read-only Pointing Port BIOS Connector Type Name pointingPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.10.9 Description Defines the basic input/output system (BIOS) connector type of the pointing port.
book.book Page 237 Monday, March 14, 2011 3:01 PM Keyboard Port Chassis Index Name keyboardPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Keyboard Port Index Name keyboardPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.2 Description Defines the index of the keyboard ports in this chassis.
book.book Page 238 Monday, March 14, 2011 3:01 PM Keyboard Port Status Name keyboardPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.5 Description Defines the status of the keyboard port. Syntax DellStatus Access Read-only Keyboard Port Security State Name keyboardPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.6 Description Defines the security settings of the keyboard port.
book.book Page 239 Monday, March 14, 2011 3:01 PM Keyboard Port BIOS Connector Type Name keyboardPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.9 Description Defines the BIOS connector type of the keyboard port. Syntax DellGenericPortConnectorType Access Read-only Processor Port Table Name processorPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.30 Description Defines the Processor Port Table.
book.book Page 240 Monday, March 14, 2011 3:01 PM Processor Port Index Name processorPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.2 Description Defines the index of the processor ports in this chassis. Syntax DellObjectRange Access Read-only Processor Port State Capabilities Name processorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.3 Description Defines the capabilities of the processor port.
book.book Page 241 Monday, March 14, 2011 3:01 PM Processor Port Security State Name processorPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.6 Description Defines the security settings of the processor port. Syntax DellPortSecurityState Access Read-only Processor Port Connector Type Name processorPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.7 Description Defines the connector type of the processor port.
book.book Page 242 Monday, March 14, 2011 3:01 PM Memory Device Port Table Name memoryDevicePortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.40 Description Defines the Memory Device Port Table. Syntax IntegerMemoryDevicePortTableEntry Access Not accessible Memory Device Port Table Entry Name memoryDevicePortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1 Description Defines the Memory Device Port Table entry.
book.book Page 243 Monday, March 14, 2011 3:01 PM Memory Device Port State Capabilities Name memoryDevicePortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.3 Description Defines the capabilities of the memory device port. Syntax DellStateCapabilities Access Read-only Memory Device Port State Settings Name memoryDevicePortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.4 Description Defines the state and settings of the memory device port.
book.book Page 244 Monday, March 14, 2011 3:01 PM Memory Device Port Connector Type Name memoryDevicePortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.7 Description Defines the connector type of the memory device port. Syntax DellMemoryDevicePortConnectorType (See Table 13-4) Access Read-only Memory Device Port Name Name memoryDevicePortName Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.8 Description Defines the name of the memory device port.
book.book Page 245 Monday, March 14, 2011 3:01 PM Memory Device Port Physical Memory Card Index Reference Name memoryDevicePortPhysicalMemoryCardIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.11 Description Defines the index (one-based) of the Physical Memory Card Table entry for the physical memory card with the same chassis index that this memory device port is associated with (if any).
book.book Page 246 Monday, March 14, 2011 3:01 PM Monitor Port Index Name monitorPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.2 Description Defines the index of the monitor ports in this chassis. Syntax DellObjectRange Access Read-only Monitor Port State Capabilities Name monitorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.3 Description Defines the capabilities of the monitor port.
book.book Page 247 Monday, March 14, 2011 3:01 PM Monitor Port Security State Name monitorPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.6 Description Defines the security settings of the monitor port. Syntax DellPortSecurityState Access Read-only Monitor Port Connector Type Name monitorPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.7 Description Defines the connector type of the monitor port.
book.book Page 248 Monday, March 14, 2011 3:01 PM Small Computer System Interface (SCSI) Port Table Name sCSIPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.60 Description Defines the SCSI Port Table. Syntax IntegerSCSIPortTableEntry Access Not accessible SCSI Port Table Entry Name sCSIPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1 Description Defines the SCSI Port Table entry.
book.book Page 249 Monday, March 14, 2011 3:01 PM SCSI Port State Capabilities Name sCSIPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.3 Description Defines the capabilities of the SCSI port. Syntax DellStateCapabilities Access Read-only SCSI Port State Settings Name DellStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.4 Description Defines the state and settings of the SCSI port.
book.book Page 250 Monday, March 14, 2011 3:01 PM SCSI Port Connector Type Name sCSIPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.7 Description Defines the connector type of the SCSI port. Syntax DellSCSIPortConnectorType (See Table 13-6) Access Read-only SCSI Port Name Name sCSIPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.8 Description Defines the name of the SCSI port.
book.book Page 251 Monday, March 14, 2011 3:01 PM Parallel Port Table Entry Name parallelPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1 Description Defines the Parallel Port Table entry. Syntax ParallelPortTableEntry Access Not accessible Index parallelPortchassisIndex, parallelPortIndex Parallel Port Chassis Index Name parallelPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 252 Monday, March 14, 2011 3:01 PM Parallel Port State Settings Name parallelPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.4 Description Defines the state and settings of the parallel port. Syntax DellStateSettings Access Read-write Parallel Port Status Name parallelPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.5 Description Defines the status of the parallel port.
book.book Page 253 Monday, March 14, 2011 3:01 PM Parallel Port Name Name parallelPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.8 Description Defines the name of the parallel port. Syntax DellString Access Read-only Parallel Port Connector Pin Out Name parallelPortConnectorPinOut Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.9 Description Defines the pinout of the parallel port.
book.book Page 254 Monday, March 14, 2011 3:01 PM Parallel Port IRQ Level Name parallelPortIRQLevel Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.12 Description Defines the Interrupt Request Level (IRQ) of the parallel port. Syntax DellUnsigned8BitRange Access Read-only Parallel Port DMA Support Name parallelPortDMASupport Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.13 Description Defines if direct memory access (DMA) is supported by the parallel port.
book.book Page 255 Monday, March 14, 2011 3:01 PM Serial Port Chassis Index Name serialPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Serial Port Index Name serialPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.2 Description Defines the index of the serial ports in this chassis.
book.book Page 256 Monday, March 14, 2011 3:01 PM Serial Port Status Name serialPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.5 Description Defines the status of the serial port. Syntax DellStatus Access Read-only Serial Port Security State Name serialPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.6 Description Defines the security settings of the serial port.
book.book Page 257 Monday, March 14, 2011 3:01 PM Serial Port Maximum Speed Name serialPortMaximumSpeed Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.9 Description Defines the maximum speed the serial interface can support in bits per second (bps). Syntax DellUnsigned32BitRange Access Read-only Serial Port Capabilities Unique Name serialPortCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.10 Description Defines additional capabilities of the serial port.
book.book Page 258 Monday, March 14, 2011 3:01 PM Universal Serial Bus (USB) Port Table Name uSBPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.90 Description Defines the USB Port Table. Syntax IntegerUSBPortTableEntry Access Not accessible USB Port Table Entry Name uSBPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1 Description Defines the USB Port Table entry.
book.book Page 259 Monday, March 14, 2011 3:01 PM USB Port State Capabilities Name uSBPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.3 Description Defines the capabilities of the USB port. Syntax DellStateCapabilities Access Read-only USB Port State Settings Name uSBPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.4 Description Defines the state and settings of the USB port.
book.book Page 260 Monday, March 14, 2011 3:01 PM USB Port Connector Type Name uSBPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.7 Description Defines the connector type of the USB port. Syntax DellUSBPortConnectorType Access Read-only USB Port Name Name uSBPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.8 Description Defines the name of the USB port. Syntax DellString Access Read-only USB Port BIOS Connector Type Name uSBPortBIOSConnectorType Object ID 1.3.6.1.4.
book.book Page 261 Monday, March 14, 2011 3:01 PM Port Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 13-1. Pointing Port Connector Type Variable Name: DellPointingPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The pointing port connector type is not one of the following: connectorPortTypeIsUnknown(2) The pointing port connector type is unknown.
book.book Page 262 Monday, March 14, 2011 3:01 PM Table 13-2. Keyboard Port Connector Types Variable Name: DellKeyboardPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The keyboard port connector type is not one of the following: connectorPortTypeIsUnknown(2) The keyboard port connector type is unknown. connectorPortTypeIsMiniDIN(3) The keyboard port connector type is a mini DIN.
book.book Page 263 Monday, March 14, 2011 3:01 PM Table 13-3. Processor Port Connector Types Variable Name: DellProcessorPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The processor port connector type is not one of the following: connectorPortTypeIsUnknown(2) The processor port connector type is unknown. connectorPortTypeIsDaughterdBoard(3) The processor port connector type is a daughter board.
book.book Page 264 Monday, March 14, 2011 3:01 PM Table 13-4. Memory Device Port Connector Types Variable Name: DellMemoryDevicePortConnectorType Data Type: Integer Possible Data Value Meaning of Data Value connectorPortTypeIsOther(1) The memory device port connector type is not one of the following: connectorPortTypeIsUnknown(2) The memory device port connector type is unknown. connectorPortTypeIsSIMM(3) The memory device port connector type is a single in-line memory module (SIMM).
book.book Page 265 Monday, March 14, 2011 3:01 PM Table 13-4. Memory Device Port Connector Types (continued) Variable Name: DellMemoryDevicePortConnectorType Data Type: Integer Possible Data Value Meaning of Data Value connectorPortTypeIsRIMM(12) The memory device port connector type is a Rambus Inline Memory Module (RIMM). connectorPortTypeIsSODIMM(13) The memory device port connector type is a small outline, dual in-line memory module (SODIMM).
book.book Page 266 Monday, March 14, 2011 3:01 PM Table 13-6. SCSI Port Connector Types Variable Name: DellSCSIPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The SCSI port connector type is not one of the following: connectorPortTypeIsUnknown(2) The SCSI port connector type is unknown. connectorPortTypeIsDIN25pin(3) The SCSI port connector type is a DIN 25-pin. connectorPortTypeIsDIN50pin(4) The SCSI port connector type is a DIN 50-pin.
book.book Page 267 Monday, March 14, 2011 3:01 PM 14 Device Group The Device Group provides information about different types of pointing, keyboard, processor, cache, memory, and peripheral component interconnect (PCI) devices. Variables in this group cover information about type, settings, configuration, manufacturer, address or location, and if applicable, the speed of the device.
book.book Page 268 Monday, March 14, 2011 3:01 PM Pointing Device Table Name pointingDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.10 Description Defines the Pointing Device Table. This group of objects references the Pointing Port Index (See Section 12). Syntax SEQUENCE OF PointingDeviceTableEntry Access Not accessible Pointing Device Table Entry Name pointingDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1 Description Defines the Pointing Device Table entry.
book.book Page 269 Monday, March 14, 2011 3:01 PM Pointing Device State Capabilities Name pointingDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.3 Description Defines the capabilities of the pointing device. Syntax DellStateCapabilities Access Read-only Pointing Device State Settings Name pointingDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.4 Description Defines the state of the pointing device.
book.book Page 270 Monday, March 14, 2011 3:01 PM Pointing Device Type Name pointingDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.7 Description Defines the type of the pointing device. Syntax DellPointingDeviceType (See Table 14-1) Access Read-only Pointing Device Number of Buttons Name pointingDeviceNumberofButtons Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.8 Description Defines the number of buttons on the pointing device.
book.book Page 271 Monday, March 14, 2011 3:01 PM Keyboard Device Chassis Index Name keyboardDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Keyboard Device Index Name keyboardDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.2 Description Defines the index of the keyboard device for this chassis.
book.book Page 272 Monday, March 14, 2011 3:01 PM Keyboard Device Status Name keyboardDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.5 Description Defines the status of the keyboard device. Syntax DellStatus Access Read-only Keyboard Port Index Reference Name keyboardPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.6 Description Defines the index to the associated the keyboard port in this chassis.
book.book Page 273 Monday, March 14, 2011 3:01 PM Processor Device Table Name processorDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.30 Description Defines the Processor Device Table. Syntax SEQUENCE OF ProcessorDeviceTableEntry Access Not accessible Processor Device Table Entry Name processorDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1 Description Defines the Processor Device Table entry.
book.book Page 274 Monday, March 14, 2011 3:01 PM Processor Device State Capabilities Name processorDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.3 Description Defines the capabilities of the processor device. Syntax DellStateCapabilities Access Read-only Processor Device State Settings Name processorDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.4 Description Defines the state of the processor device.
book.book Page 275 Monday, March 14, 2011 3:01 PM Processor Device Type Name processorDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.7 Description Defines the type of processor device. Syntax DellProcessorDeviceType (See Table 14-4) Access Read-only Processor Device Manufacturer Name Name processorDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.8 Description Defines the name of manufacturer of the processor device.
book.book Page 276 Monday, March 14, 2011 3:01 PM Processor Device Maximum Speed Name processorDeviceMaximumSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.11 Description Defines the maximum speed of the processor device in megahertz (MHz). A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Processor Device Current Speed Name processorDeviceCurrentSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.
book.book Page 277 Monday, March 14, 2011 3:01 PM Processor Device Voltage Name processorDeviceVoltage Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.14 Description Defines the voltage powering the processor device in millivolts. A zero (0) indicates the speed is unknown. Syntax DellSigned32BitRange Access Read-only Processor Device Upgrade Information Name processorDeviceUpgradeInformation Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.
book.book Page 278 Monday, March 14, 2011 3:01 PM Processor Device Core Count Name processorDeviceCoreCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.17 Description Defines the number of processor cores detected for the processor device. Syntax DellUnsigned32BitRange Access Read-only Processor Device Core Enabled Count Name processorDeviceCoreEnabledCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.18 Description Defines the number of processor cores enabled for the processor device.
book.book Page 279 Monday, March 14, 2011 3:01 PM Processor Device Characteristics Name processorDeviceCharacteristics Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.20 Description This attribute defines characteristics of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one). NOTE: Bits 2-15 need to be examined in the context of bit 1.
book.book Page 280 Monday, March 14, 2011 3:01 PM Processor Device Extended Settings Name processorDeviceExtendedSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.22 Description This attribute defines extended settings of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
book.book Page 281 Monday, March 14, 2011 3:01 PM Processor Device Stepping Name Name processorDeviceSteppingName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.25 Description Defines the stepping of the processor device. Syntax DellString Access Read-only Processor Device Status Table Name processorDeviceStatusTable Object ID 1.3.6.1.4.1.674.10892.1.1100.32 Description Defines the Processor Device Status Table.
book.book Page 282 Monday, March 14, 2011 3:01 PM Processor Device Status Index Name processorDeviceStatusIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.2 Description Defines the index (one-based) of the processor device status probe. Syntax DellObjectRange Access Read-only Processor Device Status State Capabilities Name processorDeviceStatusStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.3 Description Defines the state capabilities of the processor device status probe.
book.book Page 283 Monday, March 14, 2011 3:01 PM Processor Device Status Reading Name processorDeviceStatusReading Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.6 Description Defines the reading of the processor device status probe. Syntax DellProcessorDeviceStatusReading Access Read-only Processor Device Status Location Name Name processorDeviceStatusLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.7 Description Defines the location name of the processor device status probe.
book.book Page 284 Monday, March 14, 2011 3:01 PM Cache Device Table Entry Name cacheDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1 Description Defines the Cache Device Table entry. Syntax CacheDeviceTableEntry Access Not accessible Index cacheDevicechassisIndex, cacheDeviceIndex Cache Device Chassis Index Name cacheDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 285 Monday, March 14, 2011 3:01 PM Cache Device State Settings Name cacheDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.4 Description Defines the state of the cache device. Syntax DellStateSettings Access Read-write Cache Device Status Name cacheDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.5 Description Defines the status of the cache device.
book.book Page 286 Monday, March 14, 2011 3:01 PM Cache Device Location Name cacheDeviceLocation Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.8 Description Defines the location of the cache device. Syntax DellCacheDeviceLocation (See Table 14-13) Access Read-only Cache Device Status State Name cacheDeviceStatusState Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.9 Description Defines the status state of the cache device.
book.book Page 287 Monday, March 14, 2011 3:01 PM Cache Device Maximum Size Name cacheDeviceMaximumSize Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.12 Description Defines the maximum size of the cache device in kilobytes (KB). A zero (0) indicates that the size is unknown. Syntax DellUnsigned32BitRange Access Read-only Cache Device Current Size Name cacheDeviceCurrentSize Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.13 Description Defines the current size of the cache device in KB.
book.book Page 288 Monday, March 14, 2011 3:01 PM Cache Device Is Socketed Name cacheDeviceIsSocketed Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.16 Description Defines if the cache device is socketed. Syntax DellBoolean Access Read-only Cache Device Error Checking and Correction (ECC) Type Name cacheDeviceECCType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.17 Description Defines the type of error correction in use by the cache device.
book.book Page 289 Monday, March 14, 2011 3:01 PM Cache Device Current Type Name cacheDeviceCurrentType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.20 Description Defines the current type of SRAM for the cache device. Syntax DellCacheDeviceSRAMType (See Table 14-14) Access Read-only Memory Device Table Name memoryDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.50 Description Defines the Memory Device Table.
book.book Page 290 Monday, March 14, 2011 3:01 PM Memory Device Index Name memoryDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.2 Description Defines the index of the memory device in this chassis. Syntax DellObjectRange Access Read-only Memory Device State Capabilities Name memoryDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.3 Description Defines the capabilities of the memory device.
book.book Page 291 Monday, March 14, 2011 3:01 PM Memory Device Memory Port Index Reference Name memoryDeviceMemoryPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.6 Description Defines the index of the memory port of which this memory device is part. Syntax DellObjectRange Access Read-only Memory Device Type Name memoryDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.7 Description Defines the type of the memory device.
book.book Page 292 Monday, March 14, 2011 3:01 PM Memory Device Error Count NOTE: "Memory Device Failure Modes" on page 295 has now replaced this attribute. Memory Device Error Count should no longer be used. If you use the Memory Device Error Count attribute, the value returned is always zero, and using the attribute has no effect. Name memoryDeviceErrorCount Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.
book.book Page 293 Monday, March 14, 2011 3:01 PM Memory Device Form Factor Name memoryDeviceFormFactor Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.12 Description Defines the form factor of the memory device. Syntax DellMemoryDeviceFormFactor (See Table 14-15) Access Read-only Memory Device Set Name memoryDeviceSet Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.13 Description Defines if the memory device is a part of a set. A zero (0) indicates that this device is not part of a set.
book.book Page 294 Monday, March 14, 2011 3:01 PM Memory Device Total Bus Width Name memoryDeviceTotalBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.16 Description Defines the total number of bits, including ECC, used by the memory device. Syntax DellUnsigned32BitRange Access Read-only Memory Device Total Data Bus Width Name memoryDeviceTotalDataBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.17 Description Defines the total number of data bits used by the memory device.
book.book Page 295 Monday, March 14, 2011 3:01 PM Memory Device Uncorrectable Memory Event Count NOTE: "Memory Device Failure Modes" on page 295 has now replaced this attribute. Memory Device Uncorrectable Memory Event Count should no longer be used. If you use the Memory Device Uncorrectable Memory Event Count attribute, the value returned is always zero, and using the attribute has no effect. Name memoryDeviceMultiBitErrorCount Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.
book.book Page 296 Monday, March 14, 2011 3:01 PM Memory Device Part Number Name Name memoryDevicePartNumberName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.22 Description Defines the manufacturer's part number for the memory device. Syntax DellString Access Read-only Memory Device Serial Number Name Name memoryDeviceSerialNumberName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.23 Description Defines the serial number of the memory device.
book.book Page 297 Monday, March 14, 2011 3:01 PM Memory Device Mapped Address Table Name memoryDeviceMappedAddressTable Object ID 1.3.6.1.4.1.674.10892.1.1100.60 Description Defines the Memory Device Mapped Address Table. Syntax SEQUENCE OF MemoryDeviceMappedAddressTableEntry Access Not accessible Memory Device Mapped Address Table Entry Name memoryDeviceMappedAddressTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1 Description Defines the Memory Device Mapped Address Table entry.
book.book Page 298 Monday, March 14, 2011 3:01 PM Memory Device Mapped Address Index Name memoryDeviceMappedAddressIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.2 Description Defines the index (one-based) of the memory device mapped address in this chassis. Syntax DellObjectRange Access Read-only Memory Device Mapped Address State Capabilities Name memoryDeviceMappedAddressStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.
book.book Page 299 Monday, March 14, 2011 3:01 PM Memory Device Index Reference Name memoryDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.6 Description Defines the index of the memory device(s) associated with this memory device mapped address. Syntax DellObjectRange Access Read-only Memory Device Mapped Address Row Position Name memoryDeviceMappedAddressRowPosition Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.
book.book Page 300 Monday, March 14, 2011 3:01 PM Memory Device Mapped Address Interleave Depth Name memoryDeviceMappedAddressInterleaveDepth Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.9 Description Defines the maximum number of consecutive rows from the referenced memory device that are accessed in a single interleaved transfer in the memory device mapped address.
book.book Page 301 Monday, March 14, 2011 3:01 PM Generic Device Table Entry Name genericDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1 Description Defines the Generic Device Table entry. Syntax GenericDeviceTableEntry Access Not accessible Index genericDevicechassisIndex, genericDeviceIndex Generic Device Chassis Index Name genericDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 302 Monday, March 14, 2011 3:01 PM Generic Device State Settings Name genericDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.4 Description Defines the state of the generic device. Syntax DellStateSettings Access Read-write Generic Device Status Name genericDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.5 Description Defines the status of the generic device.
book.book Page 303 Monday, March 14, 2011 3:01 PM Generic Device Name Name genericDeviceName Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.8 Description Defines the name of the generic device. Syntax DellString Access Read-only PCI Device Table Name pCIDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.80 Description Defines the PCI Device Detail Table. Syntax SEQUENCE OF PCIDeviceTableEntry Access Not accessible PCI Device Table Entry Name pCIDeviceTableEntry Object ID 1.3.6.1.4.1.
book.book Page 304 Monday, March 14, 2011 3:01 PM PCI Device Index Name pCIDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.2 Description Defines the index (one-based) of the PCI device in this chassis. Syntax DellObjectRange Access Read-only PCI Device State Capabilities Name pCIDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.3 Description Defines the capabilities of the PCI device.
book.book Page 305 Monday, March 14, 2011 3:01 PM PCI Device System Slot Index Reference Name pCIDeviceSystemSlotIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.6 Description Defines the index number of the system slot that this PCI device is in. Syntax DellObjectRange Access Read-only PCI Device Data Bus Width Name pCIDeviceDataBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.7 Description Defines the bus width of the PCI device in this chassis.
book.book Page 306 Monday, March 14, 2011 3:01 PM PCI Device Speed Name pCIDeviceSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.10 Description Defines the bus speed in MHz of the PCI device in this chassis. A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only PCI Device Adapter Fault Name pCIDeviceAdapterFault Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.11 Description Defines whether the PCI device in this chassis has detected a fault.
book.book Page 307 Monday, March 14, 2011 3:01 PM PCI Device Configuration Space Chassis Index Name pCIDeviceConfigurationSpacechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only PCI Device Configuration Space Index Name pCIDeviceConfigurationSpaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.2 Description Defines the index (one-based) of the PCI device configuration in this chassis.
book.book Page 308 Monday, March 14, 2011 3:01 PM PCI Device Configuration Space Status Name pCIDeviceConfigurationSpaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.5 Description Defines the status of the PCI device configuration. Syntax DellStatus Access Read-only PCI Device Index Reference Name pCIDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.6 Description Defines the index number of PCI device that this configuration applies to.
book.book Page 309 Monday, March 14, 2011 3:01 PM PCI Device Configuration Space Function Number Name pCIDeviceConfigurationSpaceFunctionNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.9 Description Defines the function number of the PCI device in this chassis. Syntax DellUnsigned32BitRange Access Read-only PCI Device Configuration Space Header Name pCIDeviceConfigurationSpaceHeader Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.
book.book Page 310 Monday, March 14, 2011 3:01 PM Network Device Chassis Index Name networkDeviceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.1 Description Defines the index (one-based) of the chassis that contains the network device. Syntax DellObjectRange Access Read-only Network Device Index Name networkDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.2 Description Defines the index (one-based) of the network device.
book.book Page 311 Monday, March 14, 2011 3:01 PM Network Device Description Name Name networkDeviceDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.5 Description Defines the description of the network device. Syntax DellString Access Read-only Network Device Product Name Name networkDeviceProductName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.6 Description Defines the product name of the network device.
book.book Page 312 Monday, March 14, 2011 3:01 PM Network Device Driver Image Path Name Name networkDeviceDriverImagePathName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.9 Description Defines the path to the binary image of the driver for the network device. Syntax DellString Access Read-only Network Device Driver Version Name Name networkDeviceDriverVersionName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.10 Description Defines the version of the driver for the network device.
book.book Page 313 Monday, March 14, 2011 3:01 PM Network Device Default Gateway IP Address Name networkDeviceDefaultGatewayIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.13 Description Defines the IP address of the default gateway for the network device. Syntax IpAddress Access Read-only Network Device DHCP Server IP Address Name networkDeviceDHCPServerIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
book.book Page 314 Monday, March 14, 2011 3:01 PM Network Device PCI Bus Number Name networkDevicePCIBusNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.17 Description Defines the PCI bus number of the network device. Syntax DellUnsigned8BitRange Access Read-only Network Device PCI Device Number Name networkDevicePCIDeviceNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.18 Description Defines the PCI device number of the network device.
book.book Page 315 Monday, March 14, 2011 3:01 PM Network Device Base IO Port Address Name networkDeviceBaseIOPortAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.21 Description Defines the base input/outport port address of the network device. Syntax DellUnsigned32BitRange Access Read-only Network Device Teaming Flags Name networkDeviceTeamingFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.22 Description Defines the teaming features of the network device.
book.book Page 316 Monday, March 14, 2011 3:01 PM Network Device RDMA Capability Flags Name networkDeviceRDMACapabilityFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.25 Description Defines the Remote Direct Memory Access (RDMA) capability flags of the network device. Syntax DellNetworkDeviceRDMACapabilityFlags (see Table 14-23) Access Read-only Network Device RDMA Enabled Name networkDeviceRDMAEnabled Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
book.book Page 317 Monday, March 14, 2011 3:01 PM Managed System Services Device Table Name managedSystemServicesDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.100 Description Defines the Managed System Services Device Table. Syntax Sequence of ManagedSystemServicesDeviceTable Access Not accessible Managed System Services Device Table Entry Name managedSystemServicesDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.100.
book.book Page 318 Monday, March 14, 2011 3:01 PM Managed System Services Device Index Name managedSystemServicesDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.2 Description Defines the index (one-based) of the managed system services device. Syntax DellObjectRange Access Read-only Managed System Services Device Status Name managedSystemServicesDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.3 Description Defines the status of the managed system services device.
book.book Page 319 Monday, March 14, 2011 3:01 PM Managed System Services Device Storage Present Name managedSystemServicesDeviceStoragePresent Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.5 Description Defines whether storage is present on the managed system services device. Syntax DellBoolean Access Read-only Managed System Services Device Storage Size Name managedSystemServicesDeviceStorageSize Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.
book.book Page 320 Monday, March 14, 2011 3:01 PM Name sdCardUnitTableEntry Index sdCardUnitChassisIndex, sdCardUnitIndex SD Card Unit Chassis Index Name sdCardUnitChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.1 Description Defines the index (one-based) of the chassis that contains the SD Card unit. Syntax DellObjectRange Access Read-only SD Card Unit Index Name sdCardUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.
book.book Page 321 Monday, March 14, 2011 3:01 PM Name sdCardUnitStateSettings Description Defines the state settings of the SD Card unit. Syntax DellStateSettings Access Read-only SD Card Unit Redundancy Status Name sdCardUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.5 Description Defines the redundancy status of the SD Card unit. Syntax DellStatusRedundancy Access Read-only SD Card Unit Count For Redundancy Name sdCardUnitCountForRedundancy Object ID 1.3.6.1.4.1.
book.book Page 322 Monday, March 14, 2011 3:01 PM SD Card Unit Status Name sdCardUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.8 Description Defines the status of the SD Card unit. Syntax DellStatus Access Read-only SD Card Device Table Name sdCardDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.112 Description Defines the SD Card Device Table.
book.book Page 323 Monday, March 14, 2011 3:01 PM Name sdCardDeviceChassisIndex Access Read-only SD Card Device Index Name sdCardDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.2 Description Defines the index (one-based) of the SD Card device. Syntax DellObjectRange Access Read-only SD Card Device Status Name sdCardDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.3 Description Defines the status of the SD Card device.
book.book Page 324 Monday, March 14, 2011 3:01 PM Name sdCardDeviceConfigCapabilities Access Read-only SD Card Device Config Settings Name sdCardDeviceConfigSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.6 Description Defines the configuration settings of the SD Card device. Syntax DellSDCardDeviceConfigSettings Access Read-only SD Card Device Location Name Name sdCardDeviceLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.
book.book Page 325 Monday, March 14, 2011 3:01 PM Name sdCardDeviceCardState Access Read-only SD Card Device Card Storage Size Name sdCardDeviceCardStorageSize Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.10 Description Defines the storage size in MB (megabytes) of the SD card for the SD Card device. Syntax DellUnsigned32BitRange Access Read-only SD Card Device Unit Index Reference Name sdCardDeviceUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.
book.book Page 326 Monday, March 14, 2011 3:01 PM SD Card Device Card Available Storage Size Name sdCardDeviceCardAvailableStorageSize Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.12 Description Defines the available storage size in MB (megabytes) of the SD card for the SD card device. Syntax DellSigned32BitRange Access Read-only SD Card Device Card Licensed Name sdCardDeviceCardLicensed Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.
book.book Page 327 Monday, March 14, 2011 3:01 PM Table 14-1. Pointing Device Type (continued) Variable Name: DellPointingDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsATouchPad(7) Device type is a touch pad. Table 14-2. Processor Device Status State Variable Name: DellProcessorDeviceStatusState Data Type: Integer Possible Data Values Meaning of Data Value other(1) Processor device type is not one of the following: unknown(2) Device type is unknown.
book.book Page 328 Monday, March 14, 2011 3:01 PM Table 14-3. Processor Device Status Reading (continued) Variable Name: DellProcessorDeviceStatusReading Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value processorDisabled(256) The processor is disabled terminatorPresent(512) The terminator is Present processorThrottled(1024) The processor is throttled Table 14-4.
book.book Page 329 Monday, March 14, 2011 3:01 PM Table 14-5. Processor Upgrade Information Variable Name: DellProcessorUpgradeInformation Data Type: Integer Possible Data Values Meaning of Data Value processorUpgradeIsOther(1) The upgrade device type is not one of the following: processorUpgradeIsUnknown(2) Upgrade device type is unknown. processorUpgradeIsByDaughterBoard(3) Upgrade device is on a daughter board.
book.book Page 330 Monday, March 14, 2011 3:01 PM Table 14-5. Processor Upgrade Information (continued) Variable Name: DellProcessorUpgradeInformation Data Type: Integer Possible Data Values Meaning of Data Value processorUpgradeIsBySocket939(18) Upgrade is by Socket 939. processorUpgradeIsBySocketmPGA604(19) Upgrade is by Socket mPGA604. processorUpgradeIsBySocketLGA771(20) Upgrade is by Socket LGA771. processorUpgradeIsBySocketLGA775(21) Upgrade is by Socket LGA775.
book.book Page 331 Monday, March 14, 2011 3:01 PM Table 14-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIs80287(8) The processor family is 80287. deviceFamilyIs80387(9) The processor family is 80387. deviceFamilyIs80487(10) The processor family is 80487. deviceFamilyIsPentium(11) The processor family is Intel Pentium. deviceFamilyIsPentiumPro(12) The processor family is Pentium Pro.
book.book Page 332 Monday, March 14, 2011 3:01 PM Table 14-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsK6-2Plus(31) The processor family is K6-2+. deviceFamilyIsPowerPC(32) The processor family is Power PC. deviceFamilyIsPowerPC601(33) The processor family is Power PC 601. deviceFamilyIsPowerPC603(34) The processor family is Power PC 603.
book.book Page 333 Monday, March 14, 2011 3:01 PM Table 14-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsAMDTurionIIUltra The processor family is AMD Turion II DualMobileM(56) Ultra Dual-Core Mobile M Processor Family. deviceFamilyIsAMDTurionIIDualM The processor family is AMD Turion II obileM(57) Dual-Core Mobile M Processor Family.
book.book Page 334 Monday, March 14, 2011 3:01 PM Table 14-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsUltraSPARCIIi(86) The processor family is UltraSPARC IIi. deviceFamilyIsUltraSPARCIII(87) The processor family is UltraSPARC III. deviceFamilyIsUltraSPARCIIIi (88) The processor family is UltraSPARC IIIi. deviceFamilyIs68040(96) The processor family is 68040 Family.
book.book Page 335 Monday, March 14, 2011 3:01 PM Table 14-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsAMDAthlon64X2Dual The processor family is AMD Athlon Core(136) 64 X2 Dual-Core. deviceFamilyIsAMDTurion64X2Mob The processor family is AMD Turion 64 ile(137) X2 Mobile Technology. deviceFamilyIsQuadCoreAMDOpter The processor family is Quad-Core on(138) AMD Opteron.
book.book Page 336 Monday, March 14, 2011 3:01 PM Table 14-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel n3000(162) Xeon processor 3000 Series. deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core n5300(163) Intel Xeon processor 5300 Series.
book.book Page 337 Monday, March 14, 2011 3:01 PM Table 14-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsM2(177) The processor family is M2. deviceFamilyIsIntelPentium4HT (179) The processor family is Intel Pentium 4 HT processor. deviceFamilyIsAS400(180) The processor family is AS400. deviceFamilyIsAMDAthlonXP(182) The processor family is AMD Athlon XP.
book.book Page 338 Monday, March 14, 2011 3:01 PM Table 14-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsIntelCore2Extrem The processor family is Intel Core2 eMobile(195) Extreme mobile processor. deviceFamilyIsIntelCore2DuoMob The processor family is Intel Core2 ile(196) Duo mobile processor. deviceFamilyIsIntelCore2SoloMo The processor family is Intel Core2 bile(197) Solo mobile processor.
book.book Page 339 Monday, March 14, 2011 3:01 PM Table 14-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel n3xxx(215) Xeon processor 3xxx Series. deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core n3xxx(216) Intel Xeon processor 3xxx Series. deviceFamilyIsVIANano(217) The processor family is VIA Nano.
book.book Page 340 Monday, March 14, 2011 3:01 PM Table 14-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsAMDPhenomII(236) The processor family is AMD Phenom II. deviceFamilyIsAMDAthlonII(237) The processor family is AMD Athlon II. deviceFamilyIsSixCoreAMDOptero The processor family is Six-Core AMD n(238) Opteron. deviceFamilyIsAMDSempronM(239) The processor family is AMD Sempron M.
book.book Page 341 Monday, March 14, 2011 3:01 PM Table 14-8. Cache Device Level Variable Name: DellCacheDeviceLevel Data Type: Integer Possible Data Values Meaning of Data Value deviceLevelIsOther(1) Device level is not one of the following: deviceLevelIsUnknown(2) Device level is unknown. deviceLevelIsPrimary(3) Device level is primary. deviceLevelIsSecondary(4) Device level is secondary. deviceLevelIsTertiary(5) Device level is tertiary. Table 14-9.
book.book Page 342 Monday, March 14, 2011 3:01 PM Table 14-10. Cache Device Status State Variable Name: DellCacheDeviceStatusState Data Type: Integer Possible Data Values Meaning of Data Value other(1) Device state is not one of the following: unknown(2) Device state is unknown. enabled(3) Device is enabled. userDisabled(4) Device is disabled by the user. biosDisabled(5) Device basic input/output system (BIOS) is disabled. Table 14-11.
book.book Page 343 Monday, March 14, 2011 3:01 PM Table 14-12. Cache Device Associativity (continued) Variable Name: DellCacheDeviceAssociativity Data Type: Integer Possible Data Values Meaning of Data Value deviceAssociativityIsUnknown(2) Device associativity is unknown. deviceAssociativityIsDirectMapped(3) Device is direct mapped. deviceAssociativityIsTwoWaySetAsso ciative(4) Device is two-way set associative. deviceAssociativityIsFourWaySetAsso Device is four-way set ciative(5) associative.
book.book Page 344 Monday, March 14, 2011 3:01 PM Table 14-13. Cache Device Location Variable Name: DellCacheDeviceLocation Data Type: Integer Possible Data Values Meaning of Data Value deviceLocationIsOther(1) Device location is not one of the following: deviceLocationIsUnknown(2) Device location is unknown. deviceLocationIsInternal(3) Device location is internal. deviceLocationIsExternal(4) Device location is external. Table 14-14.
book.book Page 345 Monday, March 14, 2011 3:01 PM Table 14-15. Memory Device Type Form Factor (continued) Variable Name: DellMemoryDeviceFormFactor Data Type: Integer Possible Data Values Meaning of Data Value deviceFormFactorIsUnknown(2) Device form factor is unknown. deviceFormFactorIsSIMM(3) Device form factor is SIMM. deviceFormFactorIsSIP(4) Device form factor is SIP. deviceFormFactorIsAChip(5) Device form factor is a chip. deviceFormFactorIsDIP(6) Device form factor is DIP.
book.book Page 346 Monday, March 14, 2011 3:01 PM Table 14-16. Memory Device Type (continued) Variable Name: DellMemoryDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsVRAM(5) Device type is VRAM. deviceTypeIsSRAM(6) Device type is SRAM. deviceTypeIsRAM(7) Device type is RAM. deviceTypeIsROM(8) Device type is ROM. deviceTypeIsFLASH(9) Device type is FLASH. deviceTypeIsEEPROM(10) Device type is EEPROM. deviceTypeIsFEPROM(11) Device type is FEPROM.
book.book Page 347 Monday, March 14, 2011 3:01 PM Table 14-17. Memory Device Type Details Variable Name: DellMemoryDeviceTypeDetails Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeDetailIsOther(2) The detailed device type is not one of the following: deviceTypeDetailIsUnknown(4) The detailed device type is unknown. deviceTypeDetailIsFastPaged (8) The detailed device type is fast paged. deviceTypeDetailIsStaticColum The detailed device type is static column.
book.book Page 348 Monday, March 14, 2011 3:01 PM Table 14-18. Generic Device Type Variable Name: DellGenericDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1) Device type is not one of the following: deviceTypeIsUnknown(2) Device type is unknown. deviceTypeIsAVideoDevice(3) Device type is a video. deviceTypeIsASCSIController(4) Device type is a SCSI controller. deviceTypeIsAnEthernetDevice(5) Device type is Ethernet.
book.book Page 349 Monday, March 14, 2011 3:01 PM Table 14-19. Memory Device Failure Modes (continued) Variable Name: DellMemoryDeviceFailureModes Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value eccSingleBitCorrectionLoggingDisabled(8) Correctable Memory Event logging for memory device has been disabled. deviceDisabledBySpareActivation(16) Memory device is disabled because of spare memory activation. Table 14-20.
book.book Page 350 Monday, March 14, 2011 3:01 PM Table 14-21. Network Device Teaming Flags Variable Name: DellNetworkDeviceTeamingFlags Data Type: Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value undefined(0) Teaming flags are undefined. noTeam(1) Device is not part of any team. teamingEnabled(2) Teaming is enabled. adapterFaultToleranceMode(4) Adapter fault tolerance teaming mode.
book.book Page 351 Monday, March 14, 2011 3:01 PM Table 14-23. Network Device RDMA Capability Flags Variable Name: DellNetworkDeviceRDMACapabilityFlags Data Type: Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) Querying for RDMA capability is not supported. unknown(1) Querying for RDMA capability is supported but query returned an error. available(2) Device has RDMA capability.
book.book Page 352 Monday, March 14, 2011 3:01 PM Table 14-25. Managed System Services Device Type Variable Name: DellManagedSystemServicesDeviceType Data Type: Integer Possible Data Values Meaning of Data Value baseDevice(0) Device type is base device. optionalDevice(1) Device type is optional device. Table 14-26. SD Card Device Type Variable Name: DellSDCardDeviceType Data Type: Integer Possible Data Values Meaning of Data Value other(1) Device type is other.
book.book Page 353 Monday, March 14, 2011 3:01 PM Table 14-28. SD Card Device Config Settings Variable Name: DellSDCardDeviceConfigSettings Data Type: Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) SD card device has none of the following settings. sdEnabled(1) SD media is enabled. vFlashEnabled(2) Virtual Flash (vFlash) is enabled. Table 14-29.
book.book Page 354 Monday, March 14, 2011 3:01 PM Variable Name: DellSDCardDeviceCardLicensed Data Type: Integer Possible Data Values Meaning of Data Value licensed(1) SD card is licensed by system vendor. ipmiReady(2) Device is IPMI ready. fullReady(4) Device is full ready. offline(8) Device is offline. failed(16) Device is failed. active(32) Device is active. bootable(64) Device is bootable. writeProtect(128) Device is write-protected. standby(256) Device is in standby mode.
book.book Page 355 Monday, March 14, 2011 3:01 PM Slot Group 15 The Slot Group provides information about the types of slots that your system supports. This management information base (MIB) group also provides information about the voltages, capabilities, states, and settings that are possible for these slots. System Slot Group Table The System Slot Group defines objects in the System Slot MIB table.
book.book Page 356 Monday, March 14, 2011 3:01 PM System Slot Chassis Index Name systemSlotchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System Slot Index Name systemSlotIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.2 Description Defines the index (one-based) of the system slot in this chassis.
book.book Page 357 Monday, March 14, 2011 3:01 PM System Slot Status Name systemSlotStatus Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.5 Description Defines the status of the system slot. Syntax DellStatus Access Read-only System Slot Current Usage Name systemSlotCurrentUsage Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.6 Description Defines the current usage of the system slot. Syntax DellStatus Access Read-only System Slot Type Name systemSlotType Object ID 1.3.6.1.4.1.674.10892.1.
book.book Page 358 Monday, March 14, 2011 3:01 PM System Slot Length Name systemSlotLength Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.9 Description Defines the length of the system slot. Syntax DellSystemSlotLength (See Table 15-5) Access Read-only System Slot Slot ID Name systemSlotSlotID Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.10 Description Defines the slot identification number of the system slot. A zero (0) indicates that the slot is embedded on the motherboard.
book.book Page 359 Monday, March 14, 2011 3:01 PM System Slot Hot-Plug Slot Speed Name systemSlotHotPlugSlotSpeed Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.13 Description Defines the slot speed in megahertz of the hot-plug system slot. A zero (0) indicates that the slot speed is unknown. Syntax DellUnsigned32BitRange Access Read-only System Slot Hot-Plug Adapter Speed Name systemSlotHotPlugAdapterSpeed Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.
book.book Page 360 Monday, March 14, 2011 3:01 PM Table 15-1. System Slot State Capabilities (continued) Variable Name: DellSystemSlotStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value systemSlotHotPlugCanSignal The system slot attention state Attention(8) (and corresponding LED) can be set. systemSlotHotPlugCanSignal Power on fault (and corresponding LED) can PowerFault(16) be detected due to a short or overcurrent.
book.book Page 361 Monday, March 14, 2011 3:01 PM Table 15-2. System Slot State Settings Variable Name: DellSystemSlotStateSettings Data Type: Integer Possible Data Values Meaning of Data Value systemSlotHotPlugIsUnknown(1) The system slot’s capabilities are unknown. systemSlotHotPlugIsHotPluggable(2) The system slot supports hot-plug. systemSlotHotPlugIsPoweredOn(4) The system slot power (and corresponding LED) can be powered on.
book.book Page 362 Monday, March 14, 2011 3:01 PM Table 15-2. System Slot State Settings (continued) Variable Name: DellSystemSlotStateSettings Data Type: Integer Possible Data Values Meaning of Data Value systemSlotSupportsCard16(1024) The system slot supports PC Card-16. systemSlotSupportsCardBus(2048) The system slot supports CardBus. systemSlotSupportsZoomVideo(4096) The system slot supports zoom video. systemSlotSupportsModemRingResume The system slot supports modem (8192) ring resume.
book.book Page 363 Monday, March 14, 2011 3:01 PM Table 15-3. System Slot Type Variable Name: DellSystemSlotType Data Type: Integer Possible Data Values Meaning of Data Value systemSlotIsOther(1) The system slot type is not one of following: systemSlotIsUnknown(2) The system slot type is unknown. systemSlotIsISA(3) The system slot is Industry Standard Architecture (ISA). systemSlotIsMCA(4) The system slot is Micro Channel Architecture (MCA).
book.book Page 364 Monday, March 14, 2011 3:01 PM Table 15-3. System Slot Type (continued) Variable Name: DellSystemSlotType Data Type: Integer Possible Data Values Meaning of Data Value systemSlotIsPC98C20(18) The system slot is a PC-98/C20. systemSlotIsPC98C24(19) The system slot is a PC-98/C24. systemSlotIsPC98E(20) The system slot type is PC-98/E. systemSlotIsPC98LocalBus(21) The system slot type is a PC-98 local bus. systemSlotIsPC98Card(22) The system slot type is a PC-98 card.
book.book Page 365 Monday, March 14, 2011 3:01 PM Table 15-3. System Slot Type (continued) Variable Name: DellSystemSlotType Data Type: Integer Possible Data Values Meaning of Data Value systemSlotIsPCIExpressGen2X4(174) The system slot type is PCI Express Gen 2 x4. systemSlotIsPCIExpressGen2X8(175) The system slot type is PCI Express Gen 2 x8. systemSlotIsPCIExpressGen2X16(176) The system slot type is PCI Express Gen 2 x16. Table 15-4.
book.book Page 366 Monday, March 14, 2011 3:01 PM Table 15-6. System Slot Category Variable Name: DellSystemSlotCategory Data Type: Integer Possible Data Values Meaning of Data Value systemSlotCategoryIsOther(1) The system slot category is not one of following: systemSlotCategoryIsUnknown(2) The system slot category is unknown. systemSlotCategoryIsBusConnector(3) The system slot is a bus connector. systemSlotCategoryIsPCMCIA(4) The system slot category is PCMCIA.
book.book Page 367 Monday, March 14, 2011 3:01 PM Table 15-7. Hot-Plug Bus Width (continued) Variable Name: DellSystemSlotHotPlugBusWidth Data Type: Integer Possible Data Values Meaning of Data Value busWidthIs12xOrx12(12) The system slot bus width is 12x or x12. busWidthIs16xOrx16(13) The system slot bus width is 16x or x16. busWidthIs32xOrx32(14) The system slot bus width is 32x or x32. NOTE: System slot bus width of type n bits are for parallel buses such as PCI.
book.
book.book Page 369 Monday, March 14, 2011 3:01 PM 16 Memory Group The Memory Group provides information about the physical memory in your system. Variables in this group include error correction type, location, and different types of memory use, such as cache, flash, system, video, and nonvolatile memory.
book.book Page 370 Monday, March 14, 2011 3:01 PM The following object sets up the Physical Memory Array Table: Name physicalMemoryArrayTable Object ID 1.3.6.1.4.1.674.10892.1.1300.10 Description Defines the Physical Memory Array Table. Syntax PhysicalMemoryArrayTableEntry Access Not accessible Physical Memory Array Table Entry Name physicalMemoryArrayTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1 Description Defines the Physical Memory Array Table entry.
book.book Page 371 Monday, March 14, 2011 3:01 PM Physical Memory Array State Capabilities Name physicalMemoryArrayStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.3 Description Defines the capabilities of the physical memory array. Syntax DellStateCapabilities Access Read-only Physical Memory Array State Settings Name physicalMemoryArrayStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.4 Description Defines the state of the physical memory array.
book.book Page 372 Monday, March 14, 2011 3:01 PM Physical Memory Array Error Checking and Correcting (ECC) Type Name physicalMemoryArrayECCType Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.7 Description Defines the ECC type used by the physical memory array. Syntax DellPhysicalMemoryArrayECCType (See Table 16-2) Access Read-only Physical Memory Array Location Name physicalMemoryArrayLocation Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.
book.book Page 373 Monday, March 14, 2011 3:01 PM Physical Memory Array In Use Number Sockets Name physicalMemoryArrayInUseNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.11 Description Defines the total number of memory sockets in use by the physical memory array. Syntax DellUnsigned32BitRange Access Read-only Physical Memory Array ECC Error Nonrecoverable Threshold Name physicalMemoryArrayECCErrorNonRecoverbeThreshold Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.
book.book Page 374 Monday, March 14, 2011 3:01 PM Physical Memory Array Redundant Memory Unit Index Reference Name physicalMemoryArrayRedundantMemoryUnitIndex Reference Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.15 Description Defines the index to the associated Redundant Memory Unit in this chassis. Syntax DellObjectRange Access Read-only Physical Memory Array Mapped Table The physical memory array is divided into memory array mapped addresses.
book.book Page 375 Monday, March 14, 2011 3:01 PM Physical Memory Array Mapped Chassis Index Name physicalMemoryArrayMappedchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Physical Memory Array Mapped Index Name physicalMemoryArrayMappedIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.2 Description Defines the index (one-based) of the memory array mapped address in this chassis.
book.book Page 376 Monday, March 14, 2011 3:01 PM Physical Memory Array Mapped Status Name physicalMemoryArrayMappedStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.5 Description Defines the status of the memory array mapped address. Syntax DellStatus Access Read-only Physical Memory Array Index Reference Name physicalMemoryArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.6 Description Defines the index to the associated physical memory array in this chassis.
book.book Page 377 Monday, March 14, 2011 3:01 PM Physical Memory Array Mapped Partition Width Name physicalMemoryArrayMappedPartitionWidth Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.9 Description Defines the number of memory devices that form a single row in the memory array mapped address. A zero (0) indicates that the number is unknown.
book.book Page 378 Monday, March 14, 2011 3:01 PM Physical Memory Configuration Chassis Index Name physicalMemoryConfigChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.1 Description Defines the index (one-based) of the chassis associated with the physical memory configuration. Syntax DellObjectRange Access Read-only Physical Memory Configuration Index Name physicalMemoryConfigIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.
book.book Page 379 Monday, March 14, 2011 3:01 PM Physical Memory Configuration Status Name physicalMemoryConfigStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.5 Description Defines the status of the physical memory configuration. Syntax DellStatus Access Read-only Physical Memory Configuration Redundant Capabilities Name physicalMemoryConfigRedundantCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.6 Description Defines the redundant capabilities of the physical memory.
book.book Page 380 Monday, March 14, 2011 3:01 PM Physical Memory Logging Table Entry Name physicalMemoryLoggingTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1 Description Defines the Physical Memory Logging Table entry. Syntax PhysicalMemoryLoggingTableEntry Access Not accessible Index physicalMemoryLoggingChassisIndex, physicalMemoryLoggingIndex Physical Memory Logging Chassis Index Name physicalMemoryLoggingChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.
book.book Page 381 Monday, March 14, 2011 3:01 PM Physical Memory Logging Settings Name physicalMemoryLoggingSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.4 Description Defines the settings of the physical memory logging. Syntax DellPhysicalMemoryLoggingSettings Access Read-write Physical Memory Logging Status Name physicalMemoryLoggingStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.5 Description Defines the status of the physical memory logging.
book.book Page 382 Monday, March 14, 2011 3:01 PM Redundant Memory Unit Table Entry Name redundantMemoryUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1 Description Defines the Redundant Memory Unit Table entry. Syntax RedundantMemoryUnitTableEntry Access Not accessible Index redundantMemoryUnitChassisIndex, redundantMemoryUnitIndex Redundant Memory Unit Chassis Index Name redundantMemoryUnitChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.
book.book Page 383 Monday, March 14, 2011 3:01 PM Redundant Memory Unit State Settings Name redundantMemoryUnitStatesettings Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.4 Description Defines the state settings of the redundant memory unit. Syntax DellStateSettings Access Read-write Redundant Memory Unit Redundancy Status Name redundantMemoryUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.5 Description Defines the redundancy status of the redundant memory unit.
book.book Page 384 Monday, March 14, 2011 3:01 PM Physical Memory Card Table This table defines the name of the memory card, the total number of device slots present on the memory card, and the number of memory device slots in use on the memory card. The following objects set up the Physical Memory Card Table: Physical Memory Card Table Name physicalMemoryCardTable Object ID 1.3.6.1.4.1.674.10892.1.1300.60 Description Defines the Physical Memory Card Table.
book.book Page 385 Monday, March 14, 2011 3:01 PM Physical Memory Card Index Name physicalMemoryCardIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.2 Description Defines the index (one-based) of the Physical Memory Card. Syntax DellObjectRange Access Read-only Physical Memory Card State Capabilities Name physicalMemoryCardStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.3 Description Defines the state capabilities of the Physical Memory Card.
book.book Page 386 Monday, March 14, 2011 3:01 PM Physical Memory Card Name Name physicalMemoryCardName Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.6 Description Defines the name of the Physical Memory Card. Syntax DellString Access Read-only Physical Memory Card Total Number Sockets Name physicalMemoryCardTotalNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.7 Description Defines the total number of memory sockets available on the Physical Memory Card.
book.book Page 387 Monday, March 14, 2011 3:01 PM Physical Memory Card Physical Memory Array Index Reference Name physicalMemoryCardPhyMemArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.9 Description Defines the index (one-based) of the Physical Memory Array Table entry for the physical memory array with the same chassis index that this physical memory card is associated with.
book.book Page 388 Monday, March 14, 2011 3:01 PM Table 16-1. Physical Memory Array Location (continued) Variable Name: DellPhysicalMemoryArrayLocation Data Type: Integer Possible Data Values Meaning of Data Value memoryArrayLocationIsPCMCIA(8) The memory array location is a Personal Computer Memory Card International Association (PCMCIA) option card. memoryArrayLocationIsProprietary(9) The memory array location is a proprietary option card.
book.book Page 389 Monday, March 14, 2011 3:01 PM Table 16-2. Physical Memory Array ECC Type Definitions Variable Name: DellPhysicalMemoryArrayECCType Data Type: Integer Possible Data Values Meaning of Data Value memoryArrayECCTypeIsOther(1) There is not one of the following: memoryArrayECCTypeIsUnknown(2) The memory array ECC type is unknown. memoryArrayECCTypeIsNone(3) The memory array ECC type is none. memoryArrayECCTypeIsParity(4) The memory array ECC type is parity.
book.book Page 390 Monday, March 14, 2011 3:01 PM Table 16-4. Physical Memory Configuration State Settings Variable Name: DellPhysicalMemoryConfigStateSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no state settings. unknown(1) State settings are unknown. enabled(2) Object is disabled (offline) 0, or enabled (online) 1. notReady(4) Object not ready.
book.book Page 391 Monday, March 14, 2011 3:01 PM Table 16-6. Physical Memory Configuration Redundant Settings Variable Name: DellPhysicalMemoryConfigRedundantSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no redundant memory settings enabled. unknown(1) Redundant settings are unknown. The following redundant settings are mutually exclusive: spareEnabled(2) Spare redundant memory feature is enabled.
book.book Page 392 Monday, March 14, 2011 3:01 PM Table 16-8. Physical Memory Logging Settings Variable Name: DellPhysicalMemoryLoggingSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no logging settings enabled. unknown Capabilities(1) Logging capabilities are unknown. The logging settings are: enabled(2) 392 Memory Group Logging is disabled (0), or enabled (1).
book.book Page 393 Monday, March 14, 2011 3:01 PM BIOS Setup Control Group 17 Basic Input/Output System (BIOS) Setup Control Group variables provide information about the functions that the BIOS performs in your system. This management information base (MIB) group includes variables for the boot sequence, speakers, diskettes, ports, network interface controllers (NICs), and the Wakeup on local area network (LAN) feature.
book.book Page 394 Monday, March 14, 2011 3:01 PM BIOS Setup Control Table Entry Name biosSetUpControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1 Description Defines the BIOS Control Device Table entry. Syntax BiosSetUpControlTableEntry Access Not accessible Index biosSetUpControlchassisIndex BIOS Setup Control Chassis Index Name biosSetUpControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 395 Monday, March 14, 2011 3:01 PM BIOS Setup Control Pointing Device Control Status Name bSUCpointingDeviceControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.4 Description Defines the status of the pointing device. Syntax DellStatus Access Read-only BIOS Setup Control Pointing Device Control Name Name bSUCpointingDeviceControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.5 Description Defines the setup BIOS name of the pointing device.
book.book Page 396 Monday, March 14, 2011 3:01 PM BIOS Setup Control Numeric Lock Control Status Name bSUCnumLockControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.8 Description Defines the status of the numeric lock. Syntax DellStatus Access Read-only BIOS Setup Control Numeric Lock Control Name Name bSUCnumLockControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.9 Description Defines the setup BIOS name of the numeric lock.
book.book Page 397 Monday, March 14, 2011 3:01 PM BIOS Setup Control Processor Serial Number Control Status Name bSUCprocessorSerialNumberControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.12 Description Defines the status of the processor serial number. Syntax DellStatus Access Read-only BIOS Setup Control Processor Serial Number Control Name Name bSUCprocessorSerialNumberControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
book.book Page 398 Monday, March 14, 2011 3:01 PM BIOS Setup Control Speaker Control Status Name bSUCspeakerControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.16 Description Defines the status of speaker control. Syntax DellStatus Access Read-only BIOS Setup Control Speaker Control Name Name bSUCspeakerControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.17 Description Defines the setup BIOS name of the speaker control.
book.book Page 399 Monday, March 14, 2011 3:01 PM BIOS Setup Control NIF Wakeup on LAN Control Status Name bSUCnIFwakeonLanControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.20 Description Defines the status of the NIF Wakeup on LAN. Syntax DellStatus Access Read-only BIOS Setup Control NIF Wakeup on LAN Control Name Name bSUCnIFwakeonLanControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.21 Description Defines the setup BIOS name of the NIF Wakeup on LAN.
book.book Page 400 Monday, March 14, 2011 3:01 PM BIOS Setup Control Boot Sequence Control Status Name bSUCbootSequenceControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.24 Description Defines the status of the boot sequence. Syntax DellStatus Access Read-only BIOS Setup Control Boot Sequence Control Name Name bSUCbootSequenceControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.25 Description Defines the control name of the boot sequence.
book.book Page 401 Monday, March 14, 2011 3:01 PM BIOS Setup Control Administrator Password Control Status Name bSUCadministratorPasswordControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.28 Description Defines the status for administrator password control. Syntax DellStatus Access Read-only BIOS Setup Control Administrator Password Verify Name Name bSUCadministratorPasswordVerifyName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
book.book Page 402 Monday, March 14, 2011 3:01 PM BIOS Setup Control User Password Control Settings Unique Name bSUCuserPasswordControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.32 Description Defines the control settings for user password control. Syntax DellBIOSPasswordControlSettingsUnique (See Table 17-9) Access Read-write BIOS Setup Control User Password Control Status Name bSUCuserPasswordControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
book.book Page 403 Monday, March 14, 2011 3:01 PM BIOS Setup Control TPM Security Control Capabilities Name bSUCtpmSecurityControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.36 Description Defines the BIOS setup control capabilities of Trusted Platform Module (TPM) security. Syntax DellTPMSecurityControlCapabilities Access Read-only BIOS Setup Control TPM Security Control Setting Name bSUCtpmSecurityControlSetting Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
book.book Page 404 Monday, March 14, 2011 3:01 PM SCSI Control Table Name sCSIControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.20 Description Defines the Small Computer System Interface (SCSI) Control Table. Syntax SCSIControlTableEntry Access Not accessible SCSI Control Table Entry Name sCSIControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1 Description Defines the SCSI Control Table entry.
book.book Page 405 Monday, March 14, 2011 3:01 PM SCSI Control Capabilities Name sCSIControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.3 Description Defines the capabilities of the SCSI controller. Syntax DellStateCapabilities Access Read-only SCSI Control Settings Name sCSIControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.4 Description Defines the state of the SCSI controller.
book.book Page 406 Monday, March 14, 2011 3:01 PM Parallel Port Control Table Name parallelPortControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.30 Description Defines the Parallel Port Control Table. Syntax ParallelPortControlTableEntry Access Not accessible Parallel Port Control Table Entry Name parallelPortControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1 Description Defines the Parallel Port Control Table entry.
book.book Page 407 Monday, March 14, 2011 3:01 PM Parallel Port Control Capabilities Unique Name parallelPortControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.3 Description Defines the capabilities of the parallel port. Syntax DellParallelPortControlCapabilitiesUnique (See Table 17-12) Access Read-only Parallel Port Control Settings Unique Name parallelPortControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.
book.book Page 408 Monday, March 14, 2011 3:01 PM Parallel Port Control Mode Capabilities Unique Name parallelPortControlModeCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.7 Description Defines the mode capabilities of the parallel port. Syntax DellParallelPortControlModeCapabilitiesUnique (See Table 17-14) Access Read-only Parallel Port Control Mode Settings Unique Name parallelPortControlModeSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.
book.book Page 409 Monday, March 14, 2011 3:01 PM Serial Port Control Chassis Index Name serialPortControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.1 Description Defines index (one-based) of this chassis. Syntax DellObjectRange Access read-only Serial Port Control Index Name serialPortControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.2 Description Defines the index (one-based) of the serial port in this chassis.
book.book Page 410 Monday, March 14, 2011 3:01 PM Serial Port Control Status Name serialPortControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.5 Description Defines the status of the serial port. Syntax DellStatus Access Read-only Serial Port Control Name Name serialPortControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.6 Description Defines the setup BIOS name of the serial port.
book.book Page 411 Monday, March 14, 2011 3:01 PM USB Control Chassis Index Name usbControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.1 Description Defines index (one-based) of this chassis. Syntax DellObjectRange Access Read-only USB Control Index Name usbControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.2 Description Defines the index (one-based) of the USB in this chassis.
book.book Page 412 Monday, March 14, 2011 3:01 PM USB Control Status Name usbControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.5 Description Defines the status of the USB. Syntax DellStatus Access Read-only USB Control Name Name usbControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.6 Description Defines the setup BIOS name of the USB.
book.book Page 413 Monday, March 14, 2011 3:01 PM IDE Control Chassis Index Name ideControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only IDE Control Index Name ideControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.2 Description Defines the index (one-based) of the IDE controller in this chassis.
book.book Page 414 Monday, March 14, 2011 3:01 PM IDE Control Status Name ideControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.5 Description Defines the status for the IDE controller. Syntax DellStatus Access Read-only IDE Control Name Name ideControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.6 Description Defines the setup BIOS name for the IDE controller. Syntax DellStatus Access Read-only Diskette Control Table Name disketteControlTable Object ID 1.3.6.1.4.1.674.
book.book Page 415 Monday, March 14, 2011 3:01 PM Diskette Control Chassis Index Name disketteControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Diskette Control Index Name disketteControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.2 Description Defines the index of the diskette controllers in this chassis.
book.book Page 416 Monday, March 14, 2011 3:01 PM Diskette Control Status Name disketteControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.5 Description Defines the status of the diskette controller. Syntax DellStatus Access Read-only Diskette Control Name Name disketteControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.6 Description Defines the setup BIOS name of the diskette controller.
book.book Page 417 Monday, March 14, 2011 3:01 PM Network Interface Control Table Entry Name networkInterfaceControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1 Description Defines the Network Interface Control Table entry. Syntax NetworkInterfaceControlTableEntry Access Not accessible Index networkInterfaceControlchassisIndex, networkInterfaceControlIndex Network Interface Control Chassis Index Name networkInterfaceControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.
book.book Page 418 Monday, March 14, 2011 3:01 PM Network Interface Control Capabilities Unique Name networkInterfaceControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.3 Description Defines the capabilities of the NIC. Syntax DellNetworkInterfaceControlCapabilitiesUnique (See Table 17-19) Access Read-only Network Interface Control Settings Unique Name networkInterfaceControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.
book.book Page 419 Monday, March 14, 2011 3:01 PM BIOS Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 17-1. Speaker Control Capabilities Unique Variable Name: DellSpeakerControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Speaker control capabilities are unknown. enableCapable(2) Setup BIOS can enable speaker control.
book.book Page 420 Monday, March 14, 2011 3:01 PM Table 17-3. Network Interface (NIF) Wakeup on LAN Capabilities Unique Variable Name: DellNIFwakeonLanControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Setup BIOS Wakeup on LAN capabilities are unknown. enableCapable(2) Setup BIOS is capable of enabling the NIF Wakeup on LAN. addInCardCapable(4) Setup BIOS is capable of enabling Wakeup on LAN by option card.
book.book Page 421 Monday, March 14, 2011 3:01 PM Table 17-5. Boot Sequence Control Capabilities Unique Variable Name: DellBootSequenceControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value bootSequenceUnknown(1) Boot sequence capabilities are unknown. bootFromDisketteFirstCapable Setup BIOS can boot from a diskette (2) first. bootFromhardDriveFirstCapable Setup BIOS can boot from an IDE hard (4) drive first.
book.book Page 422 Monday, March 14, 2011 3:01 PM Table 17-7. BIOS Password Control Capabilities Variable Name: DellBIOSPasswordControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value passwordControlCapabilitiesUn BIOS password capabilities are known(1) unknown. passwordControlEnableCapable (2) Setup BIOS is capable of enabling password changes. passwordControlJumperDisable Capable(4) Setup BIOS is capable of determining if password control can be jumper disabled.
book.book Page 423 Monday, March 14, 2011 3:01 PM Table 17-9. BIOS Password Control Settings Variable Name: DellBIOSPasswordControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value passwordControlSettingsUnknown(1) Setup BIOS password state is unknown. passwordControlEnabled(2) Setup BIOS has password changes enabled. passwordControlJumperDisabled(4) Setup BIOS has determined that password control has been disabled by a jumper. Table 17-10.
book.book Page 424 Monday, March 14, 2011 3:01 PM Table 17-12. Parallel Port Control Capabilities Variable Name: DellParallelPortControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Setup BIOS parallel port capabilities are unknown. enableCapable(2) Setup BIOS can enable the parallel port. lpt1Capable(4) Setup BIOS can support parallel port 1. lpt1andEnableCapable(6) Setup BIOS has enabled parallel port 1.
book.book Page 425 Monday, March 14, 2011 3:01 PM Table 17-14. Parallel Port Control Mode Settings Variable Name: DellParallelPortControlModeSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Parallel port mode is unknown. atModeEnabled(2) Setup BIOS has set the parallel port to AT mode. ps2ModeEnabled(4) Setup BIOS has set the parallel port to Personal Systems/2 (PS/2) mode.
book.book Page 426 Monday, March 14, 2011 3:01 PM Table 17-15. Serial Port Control Capabilities (continued) Variable Name: DellSerialPortControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value com1OrCom3CapableAndAuto Setup BIOS has enabled autoconfiguration of ConfigCapable(86) COM1 and COM3 serial ports. com2OrCom4CapableAndAuto Setup BIOS has enabled autoconfiguration of ConfigCapable(106) COM2 and COM4 serial ports.
book.book Page 427 Monday, March 14, 2011 3:01 PM Table 17-17. IDE Control Capabilities Variable Name: DellideControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) IDE control capabilities are unknown. ideControlAutoConfigOrEnable IDE controller is autoconfigurable or Capable(2) enable capable. Table 17-18.
book.book Page 428 Monday, March 14, 2011 3:01 PM Table 17-20. Network Interface Control Settings Variable Name: DellNetworkInterfaceControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Network interface state is unknown. enabled(2) Network interface is enabled. enabledWithoutPXE(4) Network interface is enabled without PXE.
book.book Page 429 Monday, March 14, 2011 3:01 PM Local Response Agent Group 18 The Local Response Agent Group provides information about various attributes of your system’s local response agent (LRA). The LRA allows systems managers to predetermine how a system running the server administrator responds to a particular event type, such as the loss of redundancy in a specific component or the elevation of temperature in a chassis.
book.book Page 430 Monday, March 14, 2011 3:01 PM LRA Global Settings Table Name lRAGlobalSettingsTable Object ID 1.3.6.1.4.1.674.10892.1.1500.10 Description Defines the LRA Global Settings Table. Syntax SEQUENCE OF LRAGlobalSettingsTableEntry Access Not accessible LRA Global Settings Table Entry Name lRAGlobalSettingsTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1 Description Defines the LRA Global Settings Table entry.
book.book Page 431 Monday, March 14, 2011 3:01 PM LRA Global Settings Disable Time-out Value Name lRAGlobalSettingsDisableTimeoutValue Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.3 Description Defines the time-out duration countdown, in seconds, that the LRA global settings are disabled after a system shutdown and reboot. Syntax DellUnsigned32BitRange Access Read-only LRA Global Settings Capabilities Unique Name lRAGlobalSettingsCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.
book.book Page 432 Monday, March 14, 2011 3:01 PM LRA Action Table The DellLocalResponseAgentCapabilitiesUnique variable in the global action table defines the capabilities that are allowed for a particular system. The LRA Action Table that follows selects which of the system’s capabilities (global actions) are to be enabled. Name lRAActionTableTable Object ID 1.3.6.1.4.1.674.10892.1.1500.20 Description Defines the LRA Action Table.
book.book Page 433 Monday, March 14, 2011 3:01 PM LRA Action Table Action Number Index Name lRAActionTableActionNumberIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.2 Description Defines the LRA action number index.
book.book Page 434 Monday, March 14, 2011 3:01 PM LRA Action Table User Application Name Name lRAActionTableUserApplicationName Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.3 Description When the execute application value is set, provides the following user-assignable LRA information: • Name of the user application executable path • File name to execute Syntax DisplayString (SIZE (0..256) Access Read-write LRA Action Table Settings Unique Name lRAActionTableSettingsUnique Object ID 1.3.6.1.4.1.
book.book Page 435 Monday, March 14, 2011 3:01 PM Table 18-1. LRA Capabilities Definitions (continued) Variable Name: DellLocalResponseAgentCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value rebootCapable(16) The LRA can reboot the system. powerCycleCapable(32) The LRA is capable of a system power cycle. powerOFFCapable(64) The LRA can shut the system power off. executeApplicationCapable(256) The LRA can execute a user mode application.
book.book Page 436 Monday, March 14, 2011 3:01 PM Table 18-2. LRA Thermal Shutdown Capabilities Unique (continued) Variable Name: DellLRAThermalShutdownCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value enableOnFailureCapable(10) The LRA enables activation of chassisdetermined action(s) when a failure condition is detected. The LRA enables activation of chassisdetermined action(s) when either a failure or a warning condition is detected.
book.book Page 437 Monday, March 14, 2011 3:01 PM Cost of Ownership Group 19 The Cost of Ownership (COO) Group provides a full set of cost-tracking objects, including fields for the computer’s manufacturer, insurer, lessor, warranty, user, trouble tickets, and many others. You can use these management information base (MIB) objects to obtain accurate and complete measurements of the cost of each computer asset in your organization.
book.book Page 438 Monday, March 14, 2011 3:01 PM Cost of Ownership Table Entry Name cooTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1 Description Defines the Cost of Ownership Table entry. Syntax CooTableEntry Access Not accessible Index coochassisIndex COO Chassis Index Name coochassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.1 Description Defines the index (one-based) of this chassis. Syntax CooTableEntry Access Read-only COO State Name cooState Object ID 1.3.6.
book.book Page 439 Monday, March 14, 2011 3:01 PM COO Acquisition Waybill Number Name cooAquisitionWayBillNumber Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.4 Description Defines the waybill number of the system. Syntax DellUnsigned32BitRange Access Read-write COO Acquisition Install Date Name Name cooAquisitionInstallDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.5 Description Defines the installation date and time for the system.
book.book Page 440 Monday, March 14, 2011 3:01 PM COO Acquisition Signing Authority Name Name cooAquisitionSigningAuthorityName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.8 Description Defines the name of the authorized person who signs for the system. Syntax DellCostofOwnershipString Access Read-write COO Original Machine Configuration Expensed Name cooOriginalMachineConfigurationExpensed Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.
book.book Page 441 Monday, March 14, 2011 3:01 PM COO User Information User Name Name cooUserInformationUserName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.12 Description Defines the name of the user for this system. Syntax DellCostofOwnershipString Access Read-write COO Extended Warranty Start Date Name Name cooExtendedWarrantyStartDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.13 Description Defines the extended warranty start date for this system.
book.book Page 442 Monday, March 14, 2011 3:01 PM COO Extended Warranty Provider Name Name cooExtendedWarrantyProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.16 Description Defines the name of the extended warranty provider for this system. Syntax DellCostofOwnershipString Access Read-write COO Ownership Code Name cooOwnershipCode Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.17 Description Defines the ownership code for this system.
book.book Page 443 Monday, March 14, 2011 3:01 PM COO Deployment Date Length Name cooDeploymentDateLength Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.20 Description Defines the deployment time for this system. Syntax DellUnsigned32BitRange Access Read-write COO Deployment Duration Type Name cooDeploymentDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.21 Description Defines the deployment time units for this system.
book.book Page 444 Monday, March 14, 2011 3:01 PM COO Outsourcing Service Fee Name Name cooOutsourcingServiceFeeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.24 Description Defines amount that the outsourcing vendor charges for service. Syntax DellCostofOwnershipString Access Read-write COO Outsourcing Signing Authority Name Name cooOutsourcingSigningAuthorityName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.
book.book Page 445 Monday, March 14, 2011 3:01 PM COO Insurance Company Name Name cooInsuranceCompanyName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.28 Description Defines the name of the company that insures this system. Syntax DellCostofOwnershipString Access Read-write COO Box Asset Tag Name Name cooBoxAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.29 Description Defines the name of the asset tag.
book.book Page 446 Monday, March 14, 2011 3:01 PM COO Operating System Upgrade Type Name Name cooOperatingSystemUpgradeTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.32 Description Defines the name of the operating system on this system. Syntax DellCostofOwnershipString Access Read-write COO Operating System Upgrade Patch Level Name Name cooOperatingSystemUpgradePatchLevelName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.
book.book Page 447 Monday, March 14, 2011 3:01 PM COO Depreciation Duration Type Name cooDepreciationDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.36 Description Defines the unit of time for the depreciation of this system. Syntax DellCooMonthYearDurationType Access Read-write COO Depreciation Percentage Name cooDepreciationPercentage Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.37 Description Defines the percentage of depreciation for this system.
book.book Page 448 Monday, March 14, 2011 3:01 PM COO Service Contract Table The service contract table provides MIB objects that help you track the name, vendor, and type of service contract you have for your system. Name cooServiceContractTable Object ID 1.3.6.1.4.1.674.10892.1.1600.20 Description Defines the COO Service Contract Table. Syntax SEQUENCE OF CooServiceContractTableEntry Access Not accessible COO Service Contract Table Entry Name cooServiceContractTableEntry Object ID 1.3.6.1.4.
book.book Page 449 Monday, March 14, 2011 3:01 PM COO Service Contract State Name cooServiceContractState Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.3 Description Defines the status of the service contract for this system. Syntax DellStateSettings Access Read-only COO Service Contract Was Renewed Name cooServiceContractWasRenewed Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.4 Description Specifies whether the service contract for this system was renewed.
book.book Page 450 Monday, March 14, 2011 3:01 PM COO Cost Event Log Table The COO Cost Event Log Table provides MIB objects that allow you to track the duration and type of events that are logged for a particular system. Name cooCostEventLogTable Object ID 1.3.6.1.4.1.674.10892.1.1600.30 Description Defines the COO Cost Event Log Table. Syntax SEQUENCE OF COO CostEventLogTableEntry Access Not accessible COO Cost Event Log Table Entry Name cooCostEventLogTableEntry Object ID 1.3.6.1.4.1.674.
book.book Page 451 Monday, March 14, 2011 3:01 PM COO Cost Event Log State Name cooCostEventLogState Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.3 Description Defines the cost event log state of this system. Syntax DellStateSettings Access Read-only COO Cost Event Log Duration Name cooCostEventLogDuration Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.4 Description Defines the duration of the event for this system.
book.book Page 452 Monday, March 14, 2011 3:01 PM COO Warranty Table The COO Warranty Table objects enable you to track facts about the type and duration of the warranty for a particular system. Name cooWarrantyTable Object ID 1.3.6.1.4.1.674.10892.1.1600.40 Description Defines the COO Warranty Table. Syntax SEQUENCE OF CooWarrantyTableEntry Access Not accessible COO Warranty Table Entry Name cooWarrantyTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.40.
book.book Page 453 Monday, March 14, 2011 3:01 PM COO Warranty State Name cooWarrantyState Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.3 Description Defines the state of the warranty for this system. Syntax DellStateSettings Access Read-only COO Warranty Duration Name cooWarrantyDuration Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.4 Description Defines the duration of the warranty.
book.book Page 454 Monday, March 14, 2011 3:01 PM COO Warranty Cost Name cooWarrantyCost Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.7 Description Defines the cost of the warranty for this system. Syntax DellUnsigned32BitRange Access Read-write COO Lease Information Table The COO lease information MIB objects enable you to track information about your lessor, lease duration, and lease type for each system. Name cooLeaseInformationTable Object ID 1.3.6.1.4.1.674.10892.1.1600.
book.book Page 455 Monday, March 14, 2011 3:01 PM COO Lease Information Index Name cooLeaseInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.2 Description Defines the index of the lease information for this system. Syntax DellObjectRange Access Read-only COO Lease Information State Name cooLeaseInformationState Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.3 Description Defines the lease information state for this system.
book.book Page 456 Monday, March 14, 2011 3:01 PM COO Lease Information Lease Rate Factor Name cooLeaseInformationLeaseRateFactor Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.6 Description Defines the rate factor for the lease on this system. Syntax DellUnsigned32BitRange Access Read-write COO Lease Information End Date Name Name cooLeaseInformationEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.7 Description Defines the end date for the lease on this system.
book.book Page 457 Monday, March 14, 2011 3:01 PM COO Schedule Number Table Name cooScheduleNumberTable Object ID 1.3.6.1.4.1.674.10892.1.1600.60 Description Defines the COO Schedule Number Information Table. Syntax SEQUENCE OF CooScheduleNumberTableEntry Access Not accessible COO Schedule Number Table Entry Name cooScheduleNumberTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1 Description Defines the COO Schedule Number Information Table entry.
book.book Page 458 Monday, March 14, 2011 3:01 PM COO Schedule Number State Name cooScheduleNumberState Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.3 Description Defines the schedule number information state of this system. Syntax DellStateSettings Access Read-only COO Schedule Number Lease Information Index Reference Name cooScheduleNumberLeaseInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.
book.book Page 459 Monday, March 14, 2011 3:01 PM COO Options Table Entry Name cooOptionsTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1 Description Defines the COO Options Table entry. Syntax CooOptionsTableEntry Access Not accessible Index cooOptionschassisIndex, cooOptionsIndex COO Options Chassis Index Name cooOptionschassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 460 Monday, March 14, 2011 3:01 PM COO Options Lease Information Index Reference Name cooOptionsLeaseInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.4 Description Defines the lease information index of the option information for this system. Syntax DellUnsigned32BitRange Access Read-write COO Options Description Name Name cooOptionsDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.5 Description Defines the option information description name.
book.book Page 461 Monday, March 14, 2011 3:01 PM COO Maintenance Chassis Index Name cooMaintenancechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Maintenance Index Name cooMaintenanceIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.2 Description Defines the index of this system’s maintenance information.
book.book Page 462 Monday, March 14, 2011 3:01 PM COO Maintenance End Date Name Name cooMaintenanceEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.5 Description Defines the end date for maintenance on this system. Syntax DellDateName Access Read-write COO Maintenance Provider Name Name cooMaintenanceProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.6 Description Defines the maintenance provider’s name.
book.book Page 463 Monday, March 14, 2011 3:01 PM COO Repair Table Entry Name cooRepairTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1 Description Defines the COO Repair Table entry. Syntax CooRepairTableEntry Access Not accessible Index cooRepairchassisIndex, cooRepairIndex COO Repair Chassis Index Name cooRepairchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 464 Monday, March 14, 2011 3:01 PM COO Repair Counter Name cooRepairCounter Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.4 Description Defines the number of repairs that this system has undergone. Syntax DellCostofOwnershipString Access Read-write COO Repair Vendor Name Name cooRepairVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.5 Description Defines the name of the vendor that repairs this system.
book.book Page 465 Monday, March 14, 2011 3:01 PM COO Support Information Chassis Index Name cooSupportInformationchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Support Information Index Name cooSupportInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.2 Description Defines the index (one-based) for this system’s support information.
book.book Page 466 Monday, March 14, 2011 3:01 PM COO Support Information Type Name cooSupportInformationType Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.5 Description Defines the type of component, system, or network problem that occurred. Syntax DellUnsigned32BitRange Access Read-write COO Support Information Help Desk Name Name cooSupportInformationHelpDeskName Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.6 Description Defines the help desk information provided.
book.book Page 467 Monday, March 14, 2011 3:01 PM COO Trouble Ticket Table Entry Name cooTroubleTicketTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1 Description Defines the COO Trouble Ticket Table entry. Syntax cooTroubleTicketTableEntry Access Not accessible Index cooTroubleTicketchassisIndex, cooTroubleTicketIndex COO Trouble Ticket Chassis Index Name cooTroubleTicketchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.
book.book Page 468 Monday, March 14, 2011 3:01 PM COO Trouble Ticket Support Information Index Reference Name cooTroubleTicketSupportInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.4 Description Defines the support information index that references the trouble ticket. Syntax DellUnsigned32BitRange Access Read-write COO Trouble Ticket Number Name Name cooTroubleTicketNumberName Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.
book.book Page 469 Monday, March 14, 2011 3:01 PM Table 19-2. COO Hour Day Duration Type Variable Name: DellCooHourDayDurationType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Duration time type is unknown. hours(2) Duration time type is in hours. days(3) Duration time type is in days. Table 19-3.
book.
book.book Page 471 Monday, March 14, 2011 3:01 PM Remote Access Group 20 The Remote Access Group provides information about the remote access hardware that may be present in your system. In addition to providing general information about the capabilities and settings of the remote access hardware, this group provides information about administrative users, SNMP trap destinations, modem configuration for dial-up networking, dial-in configuration, and dial-out destinations.
book.book Page 472 Monday, March 14, 2011 3:01 PM Remote Access Chassis Index Name remoteAccessChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote Access Adapter Index Name remoteAccessAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.2 Description Defines the index (one-based) of the remote access hardware.
book.book Page 473 Monday, March 14, 2011 3:01 PM Remote Access State Settings Name remoteAccessStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.5 Description Defines the state setting of the remote access hardware. Syntax DellStateSettings Access Read-write Remote Access Status Name remoteAccessStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.6 Description Defines the status of the remote access hardware.
book.book Page 474 Monday, March 14, 2011 3:01 PM Remote Access Version Info Name Name remoteAccessVersionInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.9 Description Defines the version of the product providing the remote access functionality. Syntax DellDisplayString (SIZE (0..63)) Access Read-only Remote Access Local Area Network (LAN) Capabilities Name remoteAccessLANCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 475 Monday, March 14, 2011 3:01 PM Remote Access NIC Static Netmask Address Name remoteAccessNICStaticNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.26 Description Defines the netmask for the static IP address to be used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-write Remote Access NIC Static Gateway Address Name remoteAccessNICStaticGatewayAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 476 Monday, March 14, 2011 3:01 PM Remote Access Miscellaneous Information Name Name remoteAccessMiscInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.29 Description Defines the miscellaneous information for the remote access hardware. Syntax DisplayString (SIZE (0..63)) Access Read-write Remote Access NIC Current IP Address Name remoteAccessNICCurrentIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 477 Monday, March 14, 2011 3:01 PM Remote Access NIC Current Information From Dynamic Host Configuration Protocol (DHCP) Name remoteAccessNICCurrentInfoFromDHCP Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.33 Description Defines whether DHCP was used to obtain the NIC information currently being used by the integrated NIC provided by the remote access hardware. Syntax DellBoolean Access Read-only Remote Access Remote Connect URL Name remoteAccessRemoteConnectURL Object ID 1.3.6.
book.book Page 478 Monday, March 14, 2011 3:01 PM Remote Access Table The following MIB object sets up the Remote Access Table. Name remoteAccessTable Object ID 1.3.6.1.4.1.674.10892.1.1700.10 Description Defines the Remote Access Table. Syntax SEQUENCE OF RemoteAccessTableEntry Access Not accessible Remote Access Table Entry Name remoteAccessTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1 Description Defines the Remote Access Table entry.
book.book Page 479 Monday, March 14, 2011 3:01 PM Remote Access Type Name remoteAccessType Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.3 Description Defines the type of remote access hardware. Syntax DellRemoteAccessType (See Table 20-1) Access Read-only Remote Access State Capabilities Name remoteAccessStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.4 Description Defines the state capabilities of the remote access hardware.
book.book Page 480 Monday, March 14, 2011 3:01 PM Remote Access Product Info Name Name remoteAccessProductInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.7 Description Defines the name of the product providing the remote access functionality. Syntax DellDisplayString (SIZE (0..63)) Access Read-only Remote Access Description Info Name Name remoteAccessDescriptionInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 481 Monday, March 14, 2011 3:01 PM Remote Access Control Settings Name remoteAccessControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.11 Description Defines the control settings of the remote access hardware. Syntax DellRemoteAccessControlSettings (See Table 20-3) Access Read-write Remote Access Monitor Capabilities Name remoteAccessMonitorCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 482 Monday, March 14, 2011 3:01 PM Remote Access LAN Settings Name remoteAccessLANSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.15 Description Defines the LAN settings of the remote access hardware. Syntax DellRemoteAccessLANSettings (See Table 20-7) Access Read-write Remote Access Host Capabilities Name remoteAccessHostCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.16 Description Defines the host capabilities of the remote access hardware.
book.book Page 483 Monday, March 14, 2011 3:01 PM Remote Access Out-of-Band SNMP Settings Name remoteAccessOutOfBandSNMPSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.19 Description Defines the out-of-band SNMP settings of the remote access hardware. Syntax DellRemoteAccessOutOfBandSNMPSettings (See Table 20-11) Access Read-write Remote Access Simple Mail Transfer Protocol (SMTP) Server Internet Protocol (IP) Address Name remoteAccessSMTPServerIPAddress Object ID 1.3.6.1.4.1.674.10892.1.
book.book Page 484 Monday, March 14, 2011 3:01 PM Remote Access Firmware Update IP Address Name remoteAccessFirmwareUpdateIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.23 Description Defines the IP address of the update server providing the firmware image used by the remote access hardware. Syntax IpAddress Access Read-write Remote Access Firmware Update Path Name Name remoteAccessFirmwareUpdatePathName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 485 Monday, March 14, 2011 3:01 PM Remote Access NIC Static Gateway Address Name remoteAccessNICStaticGatewayAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.27 Description Defines the IP address for the gateway associated with the static IP address to be used by the integrated NIC provided by the remote access hardware.
book.book Page 486 Monday, March 14, 2011 3:01 PM Remote Access NIC Current IP Address Name remoteAccessNICCurrentIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.30 Description Defines the IP address currently being used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-only Remote Access NIC Current Netmask Address Name remoteAccessNICCurrentNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 487 Monday, March 14, 2011 3:01 PM Remote Access NIC Current Information From Dynamic Host Configuration Protocol (DHCP) Name remoteAccessNICCurrentInfoFromDHCP Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.33 Description Defines whether DHCP was used to obtain the NIC information currently being used by the integrated NIC provided by the remote access hardware. Syntax DellBoolean Access Read-only Remote User Administration Table Name remoteUserAdminTable Object ID 1.3.6.1.4.1.
book.book Page 488 Monday, March 14, 2011 3:01 PM Remote User Admin Chassis Index Name remoteUserAdminChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote User Admin Adapter Index Name remoteUserAdminAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
book.book Page 489 Monday, March 14, 2011 3:01 PM Remote User Admin State Settings Name remoteUserAdminStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.5 Description Defines the state settings for this remote access user. Syntax DellRemoteUserAdminStateSettings (See Table 20-13) Access Read-write Remote User Admin Status Name remoteUserAdminStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.6 Description Defines the status for this remote access user.
book.book Page 490 Monday, March 14, 2011 3:01 PM Remote User Admin User Privilege Name remoteUserAdminUserPrivilege Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.9 Description Defines the privileges for this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote User Admin User Privilege Capabilities Name remoteUserAdminUserPrivilegeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.10 Description Defines the privilege capabilities for this remote access user.
book.book Page 491 Monday, March 14, 2011 3:01 PM Remote User Admin Alert Filter DRS Capabilities Name remoteUserAdminAlertFilterDrsCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.13 Description Defines the DRS events filter capabilities for this remote access user. Syntax DellUnsigned32BitRange Access Read-only Remote User Admin Alert Filter System Capabilities Name remoteUserAdminAlertFilterSysCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
book.book Page 492 Monday, March 14, 2011 3:01 PM Remote User Admin Pager Numeric Hang-up Delay Name remoteUserAdminPagerNumericHangupDelay Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.17 Description Defines the numeric pager hang-up delay for this remote access user. Syntax DellUnsigned32BitRange Access Read-write Remote User Admin Pager Alpha Phone Number Name Name remoteUserAdminPagerAlphaPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
book.book Page 493 Monday, March 14, 2011 3:01 PM Remote User Admin Pager Alpha Custom Message Name Name remoteUserAdminPagerAlphaCustomMessageName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.21 Description Defines the message to be sent to the alphanumeric pager to inform the user of a call by this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote User Admin Pager Alpha Modem Connect Time-out Name remoteUserAdminPagerAlphaModemConnectTimeout Object ID 1.3.6.1.4.
book.book Page 494 Monday, March 14, 2011 3:01 PM Remote User Admin Pager Modem Init String Name Name remoteUserAdminPagerModemInitStringName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.25 Description Defines the initialization string to be sent to the pager modem for this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote User Admin Pager Modem Port Name remoteUserAdminPagerModemPort Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
book.book Page 495 Monday, March 14, 2011 3:01 PM Remote User Admin Control Capabilities Name remoteUserAdminControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.29 Description Defines the control capabilities for this remote access user. Syntax DellRemoteUserAdminControlCapabilities (See Table 20-14 on page 517) Access Read-only Remote User Admin Control Settings Name remoteUserAdminControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
book.book Page 496 Monday, March 14, 2011 3:01 PM Remote SNMP Trap Table Entry Name remoteSNMPTrapTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1 Description Defines the Remote Access SNMP Trap Destination Table entry. Syntax RemoteSNMPTrapTableEntry Access Not accessible Index remoteSNMPTrapChassisIndex, remoteSNMPTrapAdapterIndex, remoteSNMPTrapIndex Remote SNMP Trap Chassis Index Name remoteSNMPTrapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.
book.book Page 497 Monday, March 14, 2011 3:01 PM Remote SNMP Trap Index Name remoteSNMPTrapIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.3 Description Defines the index (one-based) of this remote access SNMP trap destination. Syntax DellObjectRange Access Read-only Remote SNMP Trap State Capabilities Name remoteSNMPTrapStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.4 Description Defines the state capabilities of this remote access SNMP trap destination.
book.book Page 498 Monday, March 14, 2011 3:01 PM Remote SNMP Trap Destination IP Address Name remoteSNMPTrapDestinationIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.7 Description Defines the IP address of this remote access SNMP trap destination. Syntax IpAddress Access Read-write Remote SNMP Trap SNMP Community Name Name remoteSNMPTrapSNMPCommunityName Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.
book.book Page 499 Monday, March 14, 2011 3:01 PM Remote SNMP Trap Filter DRS Capabilities Name remoteSNMPTrapFilterDrsCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.11 Description Defines the DRS events filter capabilities for this remote access SNMP trap destination. Syntax DellUnsigned32BitRange Access Read-only Remote SNMP Trap Filter System Capabilities Name remoteSNMPTrapFilterSysCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.
book.book Page 500 Monday, March 14, 2011 3:01 PM Remote Dial-Up Table Name remoteDialUpTable Object ID 1.3.6.1.4.1.674.10892.1.1700.40 Description Defines the Remote Access Dial-Up Table. Syntax SEQUENCE OF RemoteDialUpTableEntry Access Not accessible Remote Dial-Up Table Entry Name remoteDialUpTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1 Description Defines the Remote Access Dial-Up Table entry.
book.book Page 501 Monday, March 14, 2011 3:01 PM Remote Dial-Up Adapter Index Name remoteDialUpAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.2 Description Defines the index (one-based) of the remote access hardware that supports this remote access dial-up functionality. Syntax DellObjectRange Access Read-only Remote Dial-Up Index Name remoteDialUpIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.
book.book Page 502 Monday, March 14, 2011 3:01 PM Remote Dial-Up Status Name remoteDialUpStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.6 Description Defines the status of this remote access dial-up functionality. Syntax DellStatus Access Read-only Remote Dial-Up PPP Dial-In Base IP Address Name remoteDialUpPPPDialInBaseIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.7 Description Defines the base IP address of the PPP server for this remote access dial-up functionality.
book.book Page 503 Monday, March 14, 2011 3:01 PM Remote Dial-Up Dial-Out Modem Connect Time-out Name remoteDialUpDialOutModemConnectTimeout Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.10 Description Defines the modem dial-out time-out value in seconds for this remote access dial-up functionality. Syntax DellUnsigned32BitRange Access Read-write Remote Dial-Up Modem Dial Type Name remoteDialUpModemDialType Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.
book.book Page 504 Monday, March 14, 2011 3:01 PM Remote Dial-Up Modem Port Name remoteDialUpModemPort Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.14 Description Defines the port for the modem used by this remote access dialup functionality. Syntax DellUnsigned32BitRange Access Read-write Remote User Dial-In Configuration Table Name remoteUserDialInCfgTable Object ID 1.3.6.1.4.1.674.10892.1.1700.50 Description Defines the Remote Access User Dial-In Configuration Table.
book.book Page 505 Monday, March 14, 2011 3:01 PM Remote User Dial-In Configuration Chassis Index Name remoteUserDialInCfgChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote User Dial-In Configuration Adapter Index Name remoteUserDialInCfgAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.
book.book Page 506 Monday, March 14, 2011 3:01 PM Remote User Dial-In Configuration State Settings Name remoteUserDialInCfgStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.5 Description Defines the state settings of this remote access dial-in user. Syntax DellRemoteUserDialInStateSettings (See Table 20-26) Access Read-write Remote User Dial-In Configuration Status Name remoteUserDialInCfgStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.
book.book Page 507 Monday, March 14, 2011 3:01 PM Remote User Dial-In Configuration Callback Phone Number Name Name remoteUserDialInCfgCallbackPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.9 Description Defines the callback phone number for this remote access dial-in user. Syntax DisplayString (SIZE (0..95)) Access Read-write Remote Dial-Out Table Name remoteDialOutTable Object ID 1.3.6.1.4.1.674.10892.1.1700.60 Description Defines the Remote Access Dial-Out Table.
book.book Page 508 Monday, March 14, 2011 3:01 PM Remote Dial-Out Adapter Index Name remoteDialOutAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.2 Description Defines the index (one-based) of the remote access hardware that supports this remote access dial-out functionality. Syntax DellObjectRange Access Read-only Remote Dial-Out Dial-Out Index Name remoteDialOutDialOutIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.
book.book Page 509 Monday, March 14, 2011 3:01 PM Remote Dial-Out Status Name remoteDialOutStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.6 Description Defines the status of this remote access dial-out functionality. Syntax DellStatus Access Read-only Remote Dial-Out IP Address Name remoteDialOutIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.7 Description Defines the IP address for this remote access dial-out destination.
book.book Page 510 Monday, March 14, 2011 3:01 PM Remote Dial-Out PPP Password Name Name remoteDialOutPPPPasswordName Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.10 Description Defines the PPP password for this remote access dial-out destination. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote Access Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 20-1.
book.book Page 511 Monday, March 14, 2011 3:01 PM Table 20-2. Remote Access Control Capabilities (continued) Variable Name: DellRemoteAccessControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value logResetCapable(2) The remote access hardware can reset its integrated logs. hardResetCapable(4) The remote access hardware can perform a hard reset. softResetCapable(8) The remote access hardware can perform a soft reset.
book.book Page 512 Monday, March 14, 2011 3:01 PM Table 20-3. Remote Access Control Settings (continued) Variable Name: DellRemoteAccessControlSettings Data Type: Integer Possible Data Values Meaning of Data Value defaultConfigReset(32) The remote access hardware resets to its default settings. shutdown(64) The remote access hardware shuts down. Table 20-4.
book.book Page 513 Monday, March 14, 2011 3:01 PM Table 20-5. Remote Access Monitor Settings Variable Name: DellRemoteAccessMonitorSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no monitor settings. unknown(1) The remote access hardware monitor settings are unknown. extPwrSupplyMonitorIfConn The remote access hardware monitors the ectedEnabled(2) external power supply, if connected.
book.book Page 514 Monday, March 14, 2011 3:01 PM Table 20-7. Remote Access LAN Settings Variable Name: DellRemoteAccessLANSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no LAN settings. unknown(1) The remote access hardware LAN settings are unknown. nicEnabled(2) The remote access hardware NIC is enabled. nicDHCPEnabled(4) The remote access hardware NIC uses DHCP to obtain an IP address. Table 20-8.
book.book Page 515 Monday, March 14, 2011 3:01 PM Table 20-9. Remote Access Host Settings Variable Name: DellRemoteAccessHostSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no host settings. unknown(1) The remote access hardware host settings are unknown. smtpEmailEnabled(2) The remote access hardware SMTP client is enabled for sending e-mail.
book.book Page 516 Monday, March 14, 2011 3:01 PM Table 20-11. Remote Access Out-Of-Band Simple Network Management Protocol (SNMP) Settings Variable Name: DellRemoteAccessOutOfBandSNMPSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no out-of-band SNMP settings. unknown(1) The remote access hardware out-of-band SNMP settings are unknown. oobSNMPAgentEnabled(2) The remote access hardware out-of-band SNMP agent is enabled.
book.book Page 517 Monday, March 14, 2011 3:01 PM Table 20-13. Remote User Admin State Settings Variable Name: DellRemoteUserAdminStateSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The admin user has no state settings. unknown(1) The admin user state settings are unknown. enabled(2) The admin user is enabled. notReady(4) The admin user is in the not ready state. numericPagerEnabled(8) Numeric paging is enabled for the admin user.
book.book Page 518 Monday, March 14, 2011 3:01 PM Table 20-15. Remote User Admin Control Settings Variable Name: DellRemoteUserAdminControlSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The admin user has no control settings. unknown(1) The admin user control settings are unknown. numericPagerTest(2) A numeric pager test is performed for the admin user. alphaPagerTest(4) An alphanumeric pager test is performed for the admin user.
book.book Page 519 Monday, March 14, 2011 3:01 PM Table 20-17. Remote User Admin Alpha Baud Type Variable Name: DellRemoteUserAdminAlphaBaudType Data Type: Integer Possible Data Values Meaning of Data Value other(1) The remote user alphanumeric baud rate is not one of the following: unknown(2) The remote user alphanumeric baud rate is unknown. alphaBaud300(3) The remote user alphanumeric baud rate is 300. alphaBaud1200(4) The remote user alphanumeric baud rate is 1200. Table 20-18.
book.book Page 520 Monday, March 14, 2011 3:01 PM Table 20-20. Remote SNMP Trap Control Capabilities Variable Name: DellRemoteSNMPTrapControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The SNMP trap destination has no control capabilities. unknownCapabilities The SNMP trap destination control capabilities are (1) unknown. trapTestCapable(2) A SNMP trap test can be performed for the SNMP trap destination. Table 20-21.
book.book Page 521 Monday, March 14, 2011 3:01 PM Table 20-22. Remote Dial-Up State Capabilities (continued) Variable Name: DellRemoteDialUpStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value notReadyCapable(4) The dial-up functionality can be in the not ready state. dialInCapable(8) The dial-up functionality can support the dial-in feature. dialOutCapable(16) The dial-up functionality can support the dial-out feature.
book.book Page 522 Monday, March 14, 2011 3:01 PM Table 20-23. Remote Dial-Up State Settings (continued) Variable Name: DellRemoteDialUpStateSettings Data Type: Integer Possible Data Values Meaning of Data Value dialInDHCPEnabled(32) The dial-up functionality uses DHCP to obtain an IP address for the dial-in feature. dialInAuthAnyEnabled The dial-up functionality accepts any authentication (64) type (including clear text) for the dial-in feature.
book.book Page 523 Monday, March 14, 2011 3:01 PM Table 20-25. Remote User Dial-In State Capabilities Variable Name: DellRemoteUserDialInStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-in user has no state capabilities. unknownCapabilities(1) The dial-in user state capabilities are unknown. enableCapable(2) The dial-in user can be disabled or enabled. notReadyCapable(4) The dial-in user can be in the not ready state.
book.book Page 524 Monday, March 14, 2011 3:01 PM Table 20-27. Remote Dial-Out State Capabilities Variable Name: DellRemoteDialOutStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-out destination has no state capabilities. unknownCapabilities(1) The dial-out destination state capabilities are unknown. enableCapable(2) The dial-out destination can be disabled or enabled. notReadyCapable(4) The dial-out destination can be in the not ready state.
book.book Page 525 Monday, March 14, 2011 3:01 PM Table 20-28. Remote Dial-Out State Settings Variable Name: DellRemoteDialOutStateSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-out destination has no state settings. unknown(1) The dial-out destination state settings are unknown. enabled(2) The dial-out destination is disabled or enabled. notReady(4) The dial-out destination is in the not ready state.
book.
book.book Page 527 Monday, March 14, 2011 3:01 PM 21 Cluster Group Clustering combines multiple systems in such a way that they provide services a single system cannot. Clustering enhances higher availability, scalability, and management. Higher availability is achieved by using failover clusters, in which resources can automatically move between two or more systems in the event of a failure. Scalability is achieved by balancing the load of an application across several computer systems.
book.book Page 528 Monday, March 14, 2011 3:01 PM Cluster Chassis Index Name clusterChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Cluster Index Name clusterIndex Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.2 Description Defines the index (one-based) of the cluster. Syntax DellObjectRange Access Read-only Cluster State Capabilities Name clusterStateCapabilities Object ID 1.
book.book Page 529 Monday, March 14, 2011 3:01 PM Cluster Status Name clusterStatus Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.5 Description Defines the status of the cluster. Syntax DellStatus Access Read-only Cluster Type Name clusterType Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.6 Description Defines the type of the cluster. Syntax DellClusterType Access Read-only Cluster Type Description Name Name clusterTypeDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.
book.book Page 530 Monday, March 14, 2011 3:01 PM Cluster Group Variable Values This section includes definitions for Server Administrator-specific variable values used in this section. Table 21-1. Cluster Type Variable Name: DellClusterType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The cluster type is unknown. highAvailabilityCluster(2) The cluster type is a high-availability cluster.
book.book Page 531 Monday, March 14, 2011 3:01 PM 22 Baseboard Management Controller Group The Baseboard Management Controller (BMC) monitors the system for critical events by communicating with various sensors on the system board and sends alerts and log events when certain parameters exceed their preset thresholds. The BMC Group provides information about the BMC that may be present in your system.
book.book Page 532 Monday, March 14, 2011 3:01 PM BMC Table Entry Name bmcTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1 Description Defines the Baseboard Management Controller (BMC) Table Entry. Syntax BmcTableEntry Access Not accessible Index bmcChassisIndex, bmcIndex BMC Chassis Index Name bmcChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.1 Description Defines the index (one-based) of the associated chassis.
book.book Page 533 Monday, March 14, 2011 3:01 PM BMC State Settings Name bmcStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.4 Description Defines the state settings of the BMC. Syntax DellStateSettings Access Read-write BMC Status Name bmcStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.5 Description Defines the status of the BMC. Syntax DellStatus Access Read-only BMC Display Name Name bmcDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.
book.book Page 534 Monday, March 14, 2011 3:01 PM BMC IPMI Version Name Name bmcIPMIVersionName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.8 Description Defines the version of the Intelligent Platform Management Interface (IPMI) specification that the BMC supports. Syntax DellString Access Read-only BMC GUID Name bmcGUID Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.9 Description Defines the Globally Unique ID (GUID) of the BMC.
book.book Page 535 Monday, March 14, 2011 3:01 PM BMC IPv4 URL Name Name bmcIPv4URLName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.12 Description Defines the IPv4 URL for the BMC. The URL is not present on all systems. Syntax DisplayString (SIZE (0..1024)) Access Read-only BMC IPv6 URL Name Name bmcIPv6URLName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.13 Description Defines the IPv6 URL for the BMC. The URL is not present on all systems. Syntax DisplayString (SIZE (0..
book.book Page 536 Monday, March 14, 2011 3:01 PM BMC Serial Interface Table Entry Name bmcSerialInterfaceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1 Description Defines the BMC Serial Interface Table Entry. Syntax BmcSerialInterfaceTableEntry Access Not accessible Index bmcSerialInterfaceChassisIndex, bmcSerialInterfaceBMCIndex, bmcSerialInterfaceIndex BMC Serial Interface Chassis Index Name bmcSerialInterfaceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.
book.book Page 537 Monday, March 14, 2011 3:01 PM BMC Serial Interface State Capabilities Name bmcSerialInterfaceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.4 Description Defines the state capabilities of the BMC serial interface. Syntax DellStateCapabilities Access Read-only BMC Serial Interface State Settings Name bmcSerialInterfaceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.5 Description Defines the state settings of the BMC serial interface.
book.book Page 538 Monday, March 14, 2011 3:01 PM BMC Serial Interface Connection Mode Capabilities Name bmcSerialInterfaceConnectionModeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.8 Description Defines the connection mode capabilities of the BMC serial interface. Syntax DellBMCSerialConnectionModeCapabilities Access Read-only BMC Serial Interface Connection Mode Settings Name bmcSerialInterfaceConnectionModeSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.
book.book Page 539 Monday, March 14, 2011 3:01 PM Baseboard Management Controller LAN Interface Table Name bmcLANInterfaceTable Object ID 1.3.6.1.4.1.674.10892.1.1900.30 Description Defines the Baseboard Management Controller (BMC) LAN Interface Table. Syntax SEQUENCE OF BmcLANInterfaceTableEntry Access Not accessible BMC LAN Interface Table Entry Name bmcLANInterfaceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.30.
book.book Page 540 Monday, March 14, 2011 3:01 PM BMC LAN Interface BMC Index Name bmcLANInterfaceBMCIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.2 Description Defines the index (one-based) of the associated BMC. Syntax DellObjectRange Access Read-only BMC LAN Interface Index Name bmcLANInterfaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.3 Description Defines the index (one-based) of the BMC LAN interface.
book.book Page 541 Monday, March 14, 2011 3:01 PM BMC LAN Interface Status Name bmcLANInterfaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.6 Description Defines the status of the BMC LAN interface. Syntax DellStatus Access Read-only BMC LAN Interface Channel Number Name bmcLANInterfaceChannelNumber Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.7 Description Defines the BMC channel number of the BMC LAN interface.
book.book Page 542 Monday, March 14, 2011 3:01 PM BMC LAN Interface Subnet Mask Address Name bmcLANInterfaceSubnetMaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.10 Description Defines the subnet mask of the BMC LAN interface. Syntax IpAddress Access Read-only BMC LAN Interface Default Gateway Address Name bmcLANInterfaceDefaultGatewayAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.11 Description Defines the IP address of the default gateway for the BMC LAN interface.
book.book Page 543 Monday, March 14, 2011 3:01 PM Baseboard Management Controller Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 22-1. BMC Serial Connection Mode Capabilities Variable Name: DellBMCSerialConnectionModeCapabilities Data Type: Integer These values are bit masks; therefore, combination values are possible. Possible Data Values Meaning of Data Value -- none(0) No mode capabilities.
book.book Page 544 Monday, March 14, 2011 3:01 PM Table 22-3. BMC Serial Flow Control Type Variable Name: DellBMCSerialFlowControlType Data Type: Integer Possible Data Values Meaning of Data Value -- none(0) No flow control used. rtscts(1) RTS/CTS (hardware) flow control used. xonXoff(2) XON/XOFF flow control used. Table 22-4.
book.book Page 545 Monday, March 14, 2011 3:01 PM Table 22-6. BMC Management Controller Type Variable Name: DellManagementControllerType Data Type: Integer Possible Data Values Meaning of Data Value -- legacyBMC(0) Controller type is legacy Baseboard Management Controller. iDRAC(8) Controller type is iDRAC.
book.
book.book Page 547 Monday, March 14, 2011 3:01 PM 23 Field Replaceable Unit Group A field replaceable unit (FRU) is a part that can be removed and replaced without having to send the system to a repair facility. The Field Replaceable Unit Group provides information about the field replaceable units that may be present in your system.
book.book Page 548 Monday, March 14, 2011 3:01 PM FRU Chassis Index Name fruChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.1 Description Defines the index (one-based) of the chassis containing the FRU. Syntax DellObjectRange Access Read-only FRU Index Name fruIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.2 Description Defines the index (one-based) of the FRU. Syntax DellObjectRange Access Read-only FRU Information Status Name fruInformationStatus Object ID 1.3.6.1.4.1.
book.book Page 549 Monday, March 14, 2011 3:01 PM FRU Device Name Name fruDeviceName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.5 Description Defines the device name of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only FRU Manufacturer Name Name fruManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.6 Description Defines the manufacturer of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only FRU Serial Number Name Name fruSerialNumberName Object ID 1.
book.book Page 550 Monday, March 14, 2011 3:01 PM FRU Revision Name Name fruRevisionName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.9 Description Defines the revision of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only FRU Manufacturing Date Name Name fruManufacturingDateName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.10 Description Defines the manufacturing date of the FRU. Syntax DellDateName Access Read-only FRU Asset Tag Name Name fruAssetTagName Object ID 1.3.6.1.
book.book Page 551 Monday, March 14, 2011 3:01 PM Field Replaceable Unit Group Variable Values This section includes definitions for server administrator-specific variable values. Table 23-1. FRU Information State Variable Name: DellFRUInformationState Data Type: Integer Possible Data Values Meaning of Data Value ok(1) FRU information is okay. notSupported(2) FRU information is not supported. notAvailable(3) FRU information is not available.
book.
book.book Page 553 Monday, March 14, 2011 3:01 PM Storage Management Group 24 The Storage Management Group is composed of the following: • Storage Management Group—information about the software product and system status. • Storage Management Information Group—properties about the Simple Network Management Protocol (SNMP) agent. • Global Data Group—system status. • Physical Devices Group—physical devices managed by the software. • Logical Devices Group—logical devices managed by the software.
book.book Page 554 Monday, March 14, 2011 3:01 PM Global Status Name globalStatus Object ID 1.3.6.1.4.1.674.10893.1.20.2 Description Identifies global health for the subsystem managed by the Storage Management software. This global status is customized for HP OpenView. Other applications should refer to the agentSystemGlobalStatus entry in the globalData object group.
book.book Page 555 Monday, March 14, 2011 3:01 PM Software Description Name softwareDescription Object ID 1.3.6.1.4.1.674.10893.1.20.5 Description Identifies the product description for the Storage Management software. Syntax DisplayString Access Read-only Storage Management Information Group The Storage Management Information MIB Group defines the properties that identify the Storage Management software SNMP agent. Display Name Name displayName Object ID 1.3.6.1.4.1.674.10893.1.20.100.
book.book Page 556 Monday, March 14, 2011 3:01 PM Agent Vendor Name agentVendor Object ID 1.3.6.1.4.1.674.10893.1.20.100.3 Description Identifies the name of the management software manufacturer. Syntax DisplayString Access Read-only Agent Version Name agentVersion Object ID 1.3.6.1.4.1.674.10893.1.20.100.4 Description This entry is obsolete. Refer to softwareVersion.
book.book Page 557 Monday, March 14, 2011 3:01 PM Agent Last Global Status Name agentLastGlobalStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.2 Description This entry is obsolete. Use the value agentLastGlobalSystemStatus. Syntax Integer Access Read-only Agent Time Stamp Name agentTimeStamp Object ID 1.3.6.1.4.1.674.10893.1.20.110.3 Description Identifies the last time that the agent values have been updated. Universal time in sec since UTC 1/1/70.
book.book Page 558 Monday, March 14, 2011 3:01 PM Agent Modifiers Name agentModifiers Object ID 1.3.6.1.4.1.674.10893.1.20.110.5 Description Identifies the agent functional modifiers. When set, the modifier is active. Bit definitions: Bit 3: agent in debug mode. All other bits are product specific. Syntax Integer Access Read-only Agent Refresh Rate Name agentRefreshRate Object ID 1.3.6.1.4.1.674.10893.1.20.110.
book.book Page 559 Monday, March 14, 2011 3:01 PM Agent IP Address Name agentIPAddress Object ID 1.3.6.1.4.1.674.10893.1.20.110.8 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Agent Software Status Name agentSoftwareStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.9 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Agent SNMP Version Name agentSnmpVersion Object ID 1.3.6.1.4.1.674.10893.
book.book Page 560 Monday, March 14, 2011 3:01 PM Agent Management Software URL Name Name agentManagementSoftwareURLName Object ID 1.3.6.1.4.1.674.10893.1.20.110.12 Description Identifies the Universal Resource Locator (URL) of the systems management software. Syntax DisplayString Access Read-only Agent Global System Status Name agentGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.
book.book Page 561 Monday, March 14, 2011 3:01 PM Agent Last Global System Status Name agentLastGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.14 Description The previous global status of the system managed by the Storage Management software. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Agent Smart Thermal Shutdown Name agentSmartThermalShutdown Object ID 1.3.6.1.4.1.674.10893.1.20.110.
book.book Page 562 Monday, March 14, 2011 3:01 PM Physical Devices Group The Physical Devices MIB group provides information about the devices managed by the Storage Management software and their relationships to each other. The following MIB tables define objects and relationships (connections) among the objects. 562 • Controller Table—describes available properties for each controller on the managed system. • Channel Table—describes available properties for each channel on the managed system.
book.book Page 563 Monday, March 14, 2011 3:01 PM • Temperature Probe Table—describes available properties for each temperature probe on the managed system. • Temperature Probe Connection Table—describes the connection between each temperature probe on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table. • EMM Table—describes available properties for each Enclosure Management Module (EMM) on the managed system.
book.book Page 564 Monday, March 14, 2011 3:01 PM Controller Entry Name controllerEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1 Description Defines the controller table entry, which is an entry in the table of RAID controllers. A row in this table cannot be created or deleted by SNMP operations on columns of the table. Syntax ControllerEntry Access Not accessible Index controllerNumber Controller Number Name controllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 565 Monday, March 14, 2011 3:01 PM Controller Vendor Name controllerVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.3 Description Identifies the controller's (re)seller's name. Syntax DisplayString Access Read-only Controller Type Name controllerType Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 566 Monday, March 14, 2011 3:01 PM Controller Severity Name controllerSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.6 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Controller Rebuild Rate in Percent Name controllerRebuildRateInPercent Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 567 Monday, March 14, 2011 3:01 PM Controller Cache Size in Bytes Name controllerCacheSizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.10 Description Identifies the controller's current amount of cache memory that is less than a megabyte. This combined with the controllerCacheSizeInMB is the total amount of memory. Syntax Integer Access Read-only Controller Physical Device Count Name controllerPhysicalDeviceCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 568 Monday, March 14, 2011 3:01 PM Controller Host Port Count Name controllerHostPortCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.14 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller Memory Size in Megabytes Name controllerMemorySizeInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.15 Description Identifies the size of memory in megabytes on the controller.
book.book Page 569 Monday, March 14, 2011 3:01 PM Name controllerDriveChannelCount Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller Fault Tolerant Name controllerFaultTolerant Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.18 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
book.book Page 570 Monday, March 14, 2011 3:01 PM Controller C0 Port 0 ID Name controllerC0Port0ID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.21 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller C0 Target Name controllerC0Target Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.22 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
book.book Page 571 Monday, March 14, 2011 3:01 PM Controller C0 Battery State Name controllerC0BatteryState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.25 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller C1 Port 0 World Wide Name Name controllerC1Port0WWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.26 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
book.book Page 572 Monday, March 14, 2011 3:01 PM Controller C1 Target Name controllerC1Target Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.29 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller C1 Channel Name controllerC1Channel Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.30 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
book.book Page 573 Monday, March 14, 2011 3:01 PM Controller Node World Wide Name Name controllerNodeWWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.33 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Controller C0 Port 1 World Wide Name Name controllerC0Port1WWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.34 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
book.book Page 574 Monday, March 14, 2011 3:01 PM Name controllerBatteryChargeCount Access Read-only Controller Roll-Up Status Name controllerRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.37 Description Indicates severity of the controller state. This is the combined status of the controller and its components.
book.book Page 575 Monday, March 14, 2011 3:01 PM Controller Nexus ID Name controllerNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.39 Description Durable unique ID for this controller. Syntax DisplayString Access Read-only Controller Alarm State Name controllerAlarmState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.40 Description Indicates state, or setting for the controller's alarm.
book.book Page 576 Monday, March 14, 2011 3:01 PM Name controllerPCISlot Syntax DisplayString Access Read-only Controller Cluster Mode Name controllerClusterMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.43 Description Identifies if the controller is in cluster mode. Possible values: 1: Enabled 2: Disabled 3: Active (enabled and active) 99: Not Applicable Syntax Integer Access Read-only Controller Minimum Firmware Version Name controllerMinFWVersion Object ID 1.3.6.1.4.1.674.10893.1.
book.book Page 577 Monday, March 14, 2011 3:01 PM Name controllerMinDriverVersion Access Read-write Controller SCSI Initiator ID Name controllerSCSIInitiatorID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.46 Description The SCSI ID of the initiator. Syntax Integer Access Read-only Controller Channel Count Name controllerChannelCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.47 Description The number of channels on the controller.
book.book Page 578 Monday, March 14, 2011 3:01 PM Name controllerPatrolReadRate Access Read-only Controller BGI Rate Name controllerBGIRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.50 Description The rate for background initialization on the controller. Syntax Integer Access Read-only Controller Check Consistency Rate Name controllerCheckConsistencyRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.51 Description The rate for check consistency on the controller.
book.book Page 579 Monday, March 14, 2011 3:01 PM Controller Patrol Read State Name controllerPatrolReadState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.53 Description The state of the patrol read. Possible values: 1: Stopped - not running 2: Ready - ready to start 4: Active - is running 8: Aborted - has aborted Syntax Integer Access Read-only Controller Patrol Read Iterations Name controllerPatrolReadIterations Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 580 Monday, March 14, 2011 3:01 PM Controller Minimum Required Storport Version Name controllerMinimumRequiredStorportVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.56 Description Provides minimum required storport driver version for Windows OS only. Syntax Octet String Access Read-only Controller Encryption Capable Name controllerEncryptionCapable Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.57 Description Indicates encryption capability of the controller.
book.book Page 581 Monday, March 14, 2011 3:01 PM Controller Persistent Hot Spare Name controllerPersistentHotSpare Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.59 Description Indicates Persistent Hot Spare capability of the controller. Value: 1 - Enabled, 0 - Disabled Syntax Integer Access Read-only Controller Spin Down Unconfigured Drives Name controllerSpinDownUnconfiguredDrives Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 582 Monday, March 14, 2011 3:01 PM Name controllerSpinDownTimeInterval Description Shows the duration in minutes after which, the unconfigured or hot spare drives is spun down to power save mode. Value: 30 to 1440 NOTE: A value of 9999 indicates that the feature is not available. Syntax Integer Access Read-write Controller Encryption Mode Name controllerEncryptionMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 583 Monday, March 14, 2011 3:01 PM Channel Table This table describes available properties for each channel on the managed system. The following object sets up the Channel Table. Name channelTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.2 Description Defines the channel table. Syntax SEQUENCE OF ChannelEntry Access Not accessible Channel Entry Name channelEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1 Description Defines the channel table entry.
book.book Page 584 Monday, March 14, 2011 3:01 PM Name channelName Description Identifies the name of the channel as represented in Storage Management. The name includes the word channel and the instance. For example: Channel 1. Syntax DisplayString Access Read-only Channel State Name channelState Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.3 Description Identifies the current state of this channel. Possible states: 0: Unknown 1: Ready - The I/O has resumed.
book.book Page 585 Monday, March 14, 2011 3:01 PM Channel Termination Name channelTermination Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.5 Description Identifies the type of SCSI termination on this channel. Termination is required for proper operation of this channel. Possible values: 1: Wide Termination (16 bit) 2: Narrow Termination (8 bit) 3: Not Terminated Syntax Integer Access Read-only Channel SCSI ID Name channelSCSIID Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.
book.book Page 586 Monday, March 14, 2011 3:01 PM Channel Roll-Up Status Name channelRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.7 Description Identifies the severity of the channel state. This is the combined status of the channel and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Channel Component Status Name channelComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.
book.book Page 587 Monday, March 14, 2011 3:01 PM Channel Nexus ID Name channelNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.9 Description Durable unique ID for this channel. Syntax DisplayString Access Read-only Channel Data Rate Name channelDataRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.10 Description Identifies the data rate of this channel. Syntax DisplayString Access Read-only Channel Bus Type Name channelBusType Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.
book.book Page 588 Monday, March 14, 2011 3:01 PM Enclosure Table This table describes available properties for each enclosure on the managed system. The following object sets up the Enclosure Table. Name enclosureTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.3 Description Defines the enclosure table. Syntax SEQUENCE OF EnclosureEntry Access Not accessible Enclosure Entry Name enclosureEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1 Description Defines the enclosure table entry.
book.book Page 589 Monday, March 14, 2011 3:01 PM Enclosure Name Name enclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.2 Description Identifies the enclosure's name as represented in Storage Management. Syntax DisplayString Access Read-only Enclosure Vendor Name enclosureVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.3 Description Identifies the enclosure's (re)seller's name. Syntax DisplayString Access Read-only Enclosure State Name enclosureState Object ID 1.3.6.1.4.
book.book Page 590 Monday, March 14, 2011 3:01 PM Enclosure Severity Name enclosureSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Enclosure ID Name enclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.6 Description Identifies the SCSI address of the processor.
book.book Page 591 Monday, March 14, 2011 3:01 PM Enclosure Asset Tag Name enclosureAssetTag Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.9 Description Customer definable asset tag for the enclosure. Syntax DisplayString Access Read-only Enclosure Asset Name Name enclosureAssetName Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.10 Description Customer definable asset name of the enclosure.
book.book Page 592 Monday, March 14, 2011 3:01 PM Enclosure Kernel Version Name enclosureKernelVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.13 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Enclosure ESM1 Part Number Name enclosureESM1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.14 Description This entry is obsolete for Storage Management.
book.book Page 593 Monday, March 14, 2011 3:01 PM Enclosure Type Name enclosureType Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.16 Description Indicates the type of the enclosure.
book.book Page 594 Monday, March 14, 2011 3:01 PM Enclosure Configuration Name enclosureConfig Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.18 Description Identifies the current configuration of the enclosure's backplane. Possible values: 1: Joined 2: Split Bus 3: Clustered 4: Unified Syntax Integer Access Read-only Enclosure Channel Number Name enclosureChannelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
book.book Page 595 Monday, March 14, 2011 3:01 PM Enclosure Backplane Part Number Name enclosureBackplanePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.21 Description Identifies the part number of the enclosure's backplane. Syntax Integer Access Read-only Enclosure SCSI ID Name enclosureSCSIID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.22 Description Identifies the SCSI ID of the controller to which this enclosure is attached.
book.book Page 596 Monday, March 14, 2011 3:01 PM Enclosure Component Status Name enclosureComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.24 Description The status of the enclosure itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Enclosure Nexus ID Name enclosureNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
book.book Page 597 Monday, March 14, 2011 3:01 PM Enclosure SCSI Rate Name enclosureSCSIRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.27 Description Actual SCSI rate in the enclosure. Syntax DisplayString Access Read-only Enclosure Part Number Name enclosurePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.28 Description The part number of the enclosure. Syntax DisplayString Access Read-only Enclosure Serial Number Name enclosureSerialNumber Object ID 1.3.6.1.4.1.674.10893.
book.book Page 598 Monday, March 14, 2011 3:01 PM Enclosure Occupied Slot Count Name enclosureOccupiedSlotCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.31 Description Shows the number of physical disk slots occupied in a storage enclosure. NOTE: A value of 9999 indicates that the feature is not available. Syntax Integer Access Read-only Enclosure Total Slots Name enclosureTotalSlots Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
book.book Page 599 Monday, March 14, 2011 3:01 PM Array Disk Table This table describes available properties for each physical array disk on the managed system. The following object sets up the Array Disk Table. Name arrayDiskTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.4 Description Defines the array disk table. Syntax SEQUENCE OF ArrayDiskEntry Access Not accessible Array Disk Entry Name arrayDiskEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.
book.book Page 600 Monday, March 14, 2011 3:01 PM Array Disk Name Name arrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.2 Description Identifies the name of the array disk as represented in Storage Management. Syntax DisplayString Access Read-only Array Disk Vendor Name arrayDiskVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.3 Description The array disk's manufacturer's name.
book.book Page 601 Monday, March 14, 2011 3:01 PM Array Disk State Name arrayDiskState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.4 Description Identifies the current state of the array disk. Possible states: 0: Unknown 1: Ready - Available for use, but no RAID configuration has been assigned. 2: Failed - Not operational. 3: Online - Operational. RAID configuration has been assigned. 4: Offline - The drive is not available to the RAID controller.
book.book Page 602 Monday, March 14, 2011 3:01 PM Array Disk Severity Name arrayDiskSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Array Disk Product ID Name arrayDiskProductID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.6 Description Identifies the model number of the array disk.
book.book Page 603 Monday, March 14, 2011 3:01 PM Array Disk Enclosure ID Name arrayDiskEnclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.9 Description Identifies the SCSI ID of the enclosure processor to which this array disk belongs. Syntax DisplayString Access Read-only Array Disk Channel Name arrayDiskChannel Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.10 Description Identifies the bus to which this array disk is connected.
book.book Page 604 Monday, March 14, 2011 3:01 PM Array Disk Largest Contiguous Free Space in Megabytes Name arrayDiskLargestContiguousFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.13 Description The size in megabytes of the largest contiguous free space on the array disk. If this size is 0, it is less than a megabyte. Syntax Integer Access Read-only Array Disk Largest Contiguous Free Space in Bytes Name arrayDiskLargestContiguousFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.
book.book Page 605 Monday, March 14, 2011 3:01 PM Array Disk Used Space in Megabytes Name arrayDiskUsedSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.17 Description Identifies the amount in megabytes of the used space on the array disk. If this size is 0, it is smaller than a megabyte. Syntax Integer Access Read-only Array Disk Used Space in Bytes Name arrayDiskUsedSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
book.book Page 606 Monday, March 14, 2011 3:01 PM Array Disk Free Space in Bytes Name arrayDiskFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.20 Description Identifies the size in bytes of the free space on the array disk that is smaller than a megabyte. This size plus the arrayDiskFreeSpaceInMB is the total amount of free space on the array disk. Syntax Integer Access Read-only Array Disk Bus Type Name arrayDiskBusType Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
book.book Page 607 Monday, March 14, 2011 3:01 PM Array Disk Spare State Name arrayDiskSpareState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.22 Description Identifies the status of the array disk as a spare. Possible states: 1: Disk is a member of a virtual disk 2: Disk is a member of a disk group 3: Disk is a global hot spare 4: Disk is a dedicated hot spare 5: Not a spare 99: Not applicable Syntax Integer Access Read-only Array Disk Roll-Up Status Name arrayDiskRollUpStatus Object ID 1.3.
book.book Page 608 Monday, March 14, 2011 3:01 PM Array Disk Component Status Name arrayDiskComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.24 Description The status of the array disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Array Disk Device Name Name arrayDiskDeviceName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
book.book Page 609 Monday, March 14, 2011 3:01 PM Array Disk Part Number Name arrayDiskPartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.27 Description Indicates the part number of the disk. Syntax DisplayString Access Read-only Array Disk SAS Address Name arrayDiskSASAddress Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.28 Description Indicates the specified SAS address if this is a SAS disk.
book.book Page 610 Monday, March 14, 2011 3:01 PM Array Disk Smart Alert Indication Name arrayDiskSmartAlertIndication Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.31 Description Indicates whether the disk has received a predictive failure. Possible values: 1: No - disk has not received a predictive failure alert 2: Yes - disk has received a predictive failure alert Syntax Integer Access Read-only Array Disk Manufacture Day Name arrayDiskManufactureDay Object ID 1.3.6.1.4.1.674.10893.1.20.130.
book.book Page 611 Monday, March 14, 2011 3:01 PM Array Disk Manufacture Year Name arrayDiskManufactureYear Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.34 Description Indicates the four digit year in which this disk was manufactured. Syntax DisplayString Access Read-only Array Disk Media Type Name arrayDiskMediaType Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.35 Description Indicates the media type of the array disk.
book.book Page 612 Monday, March 14, 2011 3:01 PM Array Disk Alta Product Id Name arrayDiskAltaProductId Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.38 Description Provides product ID for Alta interposer. Syntax Octet String Access Read-only Array Disk Alta Revision Id Name arrayDiskAltaRevisionId Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.39 Description Provides revision ID for Alta interposer.
book.book Page 613 Monday, March 14, 2011 3:01 PM Array Disk Power State Name arrayDiskPowerState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.42 Description Indicates power state of a physical drive. Value: 0 - Spun up, 1- Spun down, 255 - Transition Syntax Integer Access Read-only Array Disk Enclosure Connection Table This table describes the connections among array disks, their enclosure, and their associated controller.
book.book Page 614 Monday, March 14, 2011 3:01 PM Array Disk Enclosure Connection Number Name arrayDiskEnclosureConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.1 Description Identifies the instance number of the array disk enclosure connection entry. Syntax Integer Access Read-only Array Disk Enclosure Connection Array Disk Name Name arrayDiskEnclosureConnectionArrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.
book.book Page 615 Monday, March 14, 2011 3:01 PM Array Disk Enclosure Connection Enclosure Number Name arrayDiskEnclosureConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.5 Description Identifies the instance number in the enclosureTable of the enclosure to which this array disk belongs. Syntax Integer Access Read-only Array Disk Enclosure Connection Controller Name Name arrayDiskEnclosureConnectionControllerName Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.
book.book Page 616 Monday, March 14, 2011 3:01 PM The following object sets up the Array Disk Channel Connection Table. Name arrayDiskChannelConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.6 Description Defines the array disk channel connection table. Syntax SEQUENCE OF ArrayDiskChannelConnectionEntry Access Not accessible Array Disk Channel Connection Entry Name arrayDiskChannelConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.
book.book Page 617 Monday, March 14, 2011 3:01 PM Array Disk Channel Connection Array Disk Number Name arrayDiskChannelConnectionArrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.3 Description Identifies the instance number of the array disk in the arrayDiskTable in this connection. Syntax Integer Access Read-only Array Disk Channel Connection Channel Name Name arrayDiskChannelConnectionChannelName Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.
book.book Page 618 Monday, March 14, 2011 3:01 PM Array Disk Channel Connection Controller Number Name arrayDiskChannelConnectionControllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.7 Description Identifies the instance number in the controllerTable of the controller to which this array disk is connected. Syntax Integer Access Read-only Fan Table This table describes available properties for each fan on the managed system. The following object sets up the Fan Table.
book.book Page 619 Monday, March 14, 2011 3:01 PM Fan Number Name fanNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.1 Description Identifies the instance number of the fan entry. Syntax Integer Access Read-only Fan Name Name Fan Name Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.2 Description Identifies the fan's name as represented in Storage Management. Syntax DisplayString Access Read-only Fan Vendor Name fanVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.
book.book Page 620 Monday, March 14, 2011 3:01 PM Fan State Name fanState Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.4 Description Identifies the current state of the fan. Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded 21: Missing Syntax Integer Access Read-only Fan Severity Name fanSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.5 Description This entry is obsolete for Storage Management.
book.book Page 621 Monday, March 14, 2011 3:01 PM Fan Probe Minimum Warning Name fanProbeMinimumWarning Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.7 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Fan Probe Minimum Critical Name fanProbeMinimumCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.8 Description This entry is obsolete.
book.book Page 622 Monday, March 14, 2011 3:01 PM Fan Probe Current Value Name fanProbeCurrValue Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.11 Description Identifies the current speed of the fan. Syntax DisplayString Access Read-only Fan1 Part Number Name fan1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.12 Description Identifies the part number of the fan in the enclosure. Syntax DisplayString Access Read-only Fan 2 Part Number Name fan2PartNumber Object ID 1.3.6.1.4.1.
book.book Page 623 Monday, March 14, 2011 3:01 PM Fan Roll-Up Status Name fanRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.14 Description Severity of the fan state. This is the combined status of the fan and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Fan Component Status Name fanComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.
book.book Page 624 Monday, March 14, 2011 3:01 PM Fan Nexus ID Name fanNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.16 Description Durable unique ID for this fan. Syntax DisplayString Access Read-only Fan Revision Name fanRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.17 Description Indicates the revision number of the fan in the enclosure.
book.book Page 625 Monday, March 14, 2011 3:01 PM Name fanConnectionEntry Syntax FanConnectionEntry Access Not accessible Index fanConnectionNumber Fan Connection Number Name fanConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.1 Description Identifies the instance number of the fan connection entry. Syntax Integer Access Read-only Fan Connection Fan Name Name fanConnectionFanName Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.
book.book Page 626 Monday, March 14, 2011 3:01 PM Fan Connection Enclosure Name Name fanConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.4 Description Identifies the name of the enclosure as represented in Storage Management to which this fan belongs. Syntax DisplayString Access Read-only Fan Connection Enclosure Number Name fanConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.
book.book Page 627 Monday, March 14, 2011 3:01 PM Power Supply Entry Name powerSupplyEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1 Description Defines the power supply table entry. Syntax PowerSupplyEntry Access Not accessible Index powerSupplyNumber Power Supply Number Name powerSupplyNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.1 Description Identifies the instance number of the power supply entry.
book.book Page 628 Monday, March 14, 2011 3:01 PM Power Supply State Name powerSupplyState Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.4 Description Identifies the current state of the power supply. Possible states: 0: Unknown 1: Ready 2: Failed 5: Not Installed 6: Degraded 11: Removed Syntax Integer Access Read-only Power Supply Severity Name powerSupplySeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.5 Description This entry is obsolete for Storage Management.
book.book Page 629 Monday, March 14, 2011 3:01 PM Power Supply 2 Part Number Name powerSupply2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.7 Description This entry is obsolete. This setting is not supported by power supplies managed under Storage Management Syntax DisplayString Access Read-only Power Supply Roll-Up Status Name powerSupplyRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.8 Description Severity of the power supply state.
book.book Page 630 Monday, March 14, 2011 3:01 PM Power Supply Component Status Name powerSupplyComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.9 Description Severity of the power supply state. This is the combined status of the power supply and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Power Supply NexusID Name powerSupplyNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.
book.book Page 631 Monday, March 14, 2011 3:01 PM Power Supply Connection Table This table describes the connection between each power supply on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table. The following object sets up the Power Supply Connection Table. Name powerSupplyConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.10 Description Defines the power supply connection table.
book.book Page 632 Monday, March 14, 2011 3:01 PM Power Supply Connection Power Supply Name Name powerSupplyConnectionPowerSupplyName Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.2 Description Identifies the name of the power supply in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Power Supply Connection Power Supply Number Name powerSupplyConnectionPowerSupplyNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.
book.book Page 633 Monday, March 14, 2011 3:01 PM Temperature Probe Table This table describes available properties for each temperature probe on the managed system. The following object sets up the Temperature Probe Table. Name temperatureProbeTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.11 Description A table of managed temperature probes. The number of entries is related to the number of temperature probes discovered in the system. The maximum number of entries is implementation dependent.
book.book Page 634 Monday, March 14, 2011 3:01 PM Temperature Probe Name Name temperatureProbeName Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.2 Description Identifies the temperature probe's name as represented in Storage Management. Syntax DisplayString Access Read-only Temperature Probe Vendor Name temperatureProbeVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.3 Description Identifies the temperature probe's (re)seller's name.
book.book Page 635 Monday, March 14, 2011 3:01 PM Temperature Probe Severity Name temperatureProbeSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Temperature Probe Unit Name temperatureProbeUnit Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.
book.book Page 636 Monday, March 14, 2011 3:01 PM Temperature Probe Maximum Warning Name temperatureProbeMaxWarning Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.9 Description Identifies the maximum temperature that forces the probe into a warning state. Syntax Integer Access Read-only Temperature Probe Maximum Critical Name temperatureProbeMaxCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.10 Description Identifies the maximum temperature that forces the probe into an error state.
book.book Page 637 Monday, March 14, 2011 3:01 PM Temperature Probe Roll-Up Status Name temperatureProbeRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.12 Description Severity of the temperature probe state. This is the combined status of the temperature probe and its components.
book.book Page 638 Monday, March 14, 2011 3:01 PM Temperature Probe Nexus ID Name temperatureProbeNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.14 Description Durable unique ID for this temperature probe. Syntax DisplayString Access Read-only Temperature Probe Connection Table This table describes the connection between each temperature probe on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table.
book.book Page 639 Monday, March 14, 2011 3:01 PM Temperature Probe Connection Number Name temperatureConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.1 Description Identifies the instance number of the temperature probe connection entry. Syntax Integer Access Read-only Temperature Probe Connection Temperature Probe Name Name temperatureConnectionTemperatureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.
book.book Page 640 Monday, March 14, 2011 3:01 PM Temperature Probe Connection Enclosure Number Name temperatureConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.5 Description Identifies the instance number of the enclosure in the enclosureTable to which this temperature probe belongs. Syntax Integer Access Read-only Enclosure Management Module Table This table describes available properties for each enclosure management module on the managed system.
book.book Page 641 Monday, March 14, 2011 3:01 PM Enclosure Management Module Number Name enclosureManagementModuleNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.1 Description Identifies the instance number of the enclosure management module entry. Syntax Integer Access Read-only Enclosure Management Module Name Name enclosureManagementModuleName Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.
book.book Page 642 Monday, March 14, 2011 3:01 PM Enclosure Management Module State Name enclosureManagementModuleState Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.4 Description Identifies the current state of the enclosure management module. Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 5: Not Installed 6: Degraded 21: Missing Syntax Integer Access Read-only Enclosure Management Module Severity Name enclosureManagementModuleSeverity Object ID 1.3.6.1.4.1.674.10893.1.
book.book Page 643 Monday, March 14, 2011 3:01 PM Enclosure Management Module Type Name enclosureManagementModuleType Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.7 Description Identifies the type of the enclosure management module. Possible values: 0: Unknown 1: EMM 2: Termination Card Syntax Integer Access Read-only Enclosure Management Module Firmware Version Name enclosureManagementModuleFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.
book.book Page 644 Monday, March 14, 2011 3:01 PM Enclosure Management Module Roll-Up Status Name enclosureManagementModuleRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.10 Description Severity of the enclosure management module state. This is the combined status of the EMM and its components.
book.book Page 645 Monday, March 14, 2011 3:01 PM Enclosure Management Module Nexus ID Name enclosureManagementModuleNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.12 Description Durable unique ID for this EMM. Syntax DisplayString Access Read-only Enclosure Management Module Revision Name enclosureManagementModuleRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.13 Description Identifies the revision number of the enclosure management module.
book.book Page 646 Monday, March 14, 2011 3:01 PM Enclosure Management Module Connection Entry Name enclosureManagementModuleConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1 Description Defines the enclosure memory module connection table entry. Syntax EnclosureManagementModuleConnectionEntry Access Not accessible Index enclosureManagementModuleConnectionNumber Enclosure Management Module Connection Number Name enclosureManagementModuleConnectionNumber Object ID 1.3.6.1.4.1.674.
book.book Page 647 Monday, March 14, 2011 3:01 PM Enclosure Management Module Connection EMM Number Name enclosureManagementModuleConnectionEMMNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.3 Description Identifies the instance number in the enclosureManagementModuleTable of the enclosure memory module in this connection. Syntax Integer Access Read-only Enclosure Management Module Connection Enclosure Name Name enclosureManagementModuleConnectionEnclosureName Object ID 1.3.6.1.4.1.674.
book.book Page 648 Monday, March 14, 2011 3:01 PM Battery Table This table describes available properties for each controller battery on the managed system. The following object sets up the Battery Table. Name batteryTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.15 Description Defines the battery table. Syntax SEQUENCE OF BatteryEntry Access Not accessible Battery Entry Name batteryEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1 Description Defines the battery table entry.
book.book Page 649 Monday, March 14, 2011 3:01 PM Battery Name Name batteryName Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.2 Description Identifies the battery's name as represented in Storage Management. Syntax DisplayString Access Read-only Battery Vendor Name batteryVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.3 Description Identifies the battery's (re)seller's name. Syntax DisplayString Access Read-only Battery State Name batteryState Object ID 1.3.6.1.4.1.674.10893.1.
book.book Page 650 Monday, March 14, 2011 3:01 PM Battery Roll-Up Status Name batteryRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.5 Description Severity of the battery state. This is the combined status of the battery and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Battery Component Status Name batteryComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.
book.book Page 651 Monday, March 14, 2011 3:01 PM Battery Charge Count Name batteryChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.7 Description The number of charges that have been applied to the battery. Syntax Integer Access Read-only Battery Max Charge Count Name batteryMaxChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.8 Description The maximum number of charges that can be applied to the battery.
book.book Page 652 Monday, March 14, 2011 3:01 PM Battery Predicted Capacity Name batteryPredictedCapacity Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.10 Description Displays the battery's ability to be charged. Possible values: 1: Failed - The battery cannot be charged and needs to be replaced. 2: Ready - The battery can be charged to full capacity. 4: Unknown - The battery is completing a Learn cycle. The charge capacity of the battery cannot be determined until the Learn cycle is complete.
book.book Page 653 Monday, March 14, 2011 3:01 PM Battery Learn State Name batteryLearnState Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.12 Description Specifies the learn state activity of the battery. Possible values: 1: Failed 2: Active 4: Timed out 8: Requested 16: Idle Syntax Integer Access Read-only Battery Maximum Learn Delay Name batteryMaxLearnDelay Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.
book.book Page 654 Monday, March 14, 2011 3:01 PM Battery Connection Table This table describes the connection between each controller battery on the managed system and its controller. Each controller number in the table corresponds to that controller instance in the controller Table. The following object sets up the Battery Connection Table. Name batteryConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.16 Description Defines the battery connection table.
book.book Page 655 Monday, March 14, 2011 3:01 PM Battery Connection Battery Name Name batteryConnectionBatteryName Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.2 Description Identifies the name of the battery in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Battery Connection Battery Number Name batteryConnectionBatteryNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.
book.book Page 656 Monday, March 14, 2011 3:01 PM Logical Devices Group The Logical Devices Management Information Base (MIB) group provides information about the logical devices managed by the Dell Storage Management Software and their relationships to each other. This group and all of its associated tables and objects are not supported on Microsoft Windows Advanced Server Limited Edition 64-bit operating system (Windows.Net-64) on a Dell PowerEdge 7150.
book.book Page 657 Monday, March 14, 2011 3:01 PM Virtual Disk Entry Name virtualDiskEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1 Description Defines the virtual disk table entry. Syntax VirtualDiskEntry Access Not accessible Index virtualDiskNumber Virtual Disk Number Name virtualDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.1 Description Identifies the instance number of the virtual disk entry.
book.book Page 658 Monday, March 14, 2011 3:01 PM Virtual Disk State Name virtualDiskState Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.4 Description Identifies the current state of this virtual disk. Possible states: 0: Unknown 1: Ready - The disk is accessible and has no known problems. 2: Failed - The data on the virtual disk is no longer fault tolerant because one of the underlying disks is not online. 3: Online 4: Offline - The disk is not accessible.
book.book Page 659 Monday, March 14, 2011 3:01 PM Virtual Disk Severity Name virtualDiskSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Virtual Disk Length in Megabytes Name virtualDiskLengthInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.6 Description Identifies the size of this virtual disk in megabytes.
book.book Page 660 Monday, March 14, 2011 3:01 PM Virtual Disk Free Space in Megabytes Name virtualDiskFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.8 Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax Integer Access Read-only Virtual Disk Free Space in Bytes Name virtualDiskFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.9 Description This entry is obsolete.
book.book Page 661 Monday, March 14, 2011 3:01 PM Virtual Disk Read Policy Name virtualDiskReadPolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.11 Description Indicates whether the controller's read cache are used when reading from a virtual disk.
book.book Page 662 Monday, March 14, 2011 3:01 PM Virtual Disk Layout Name virtualDiskLayout Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.13 Description Indicates the virtual disk's RAID type. Possible values: 1: Concatenated 2: RAID-0 3: RAID-1 7: RAID-5 8: RAID-6 10: RAID-10 12: RAID-50 19: Concatenated RAID 1 24: RAID-60 Syntax Integer Access Read-only Virtual Disk Current Stripe Size in Megabytes Name virtualDiskCurStripeSizeInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
book.book Page 663 Monday, March 14, 2011 3:01 PM Virtual Disk Current Stripe Size in Bytes Name virtualDiskCurStripeSizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.15 Description Identifies the portion of the stripe size in bytes that is smaller than a megabyte. This size plus the virtualDiskCurStripeSizeInMB is the total stripe size on the virtual disk. Syntax Integer Access Read-only Virtual Disk Channel Name virtualDiskChannel Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
book.book Page 664 Monday, March 14, 2011 3:01 PM Virtual Disk Roll-Up Status Name virtualDiskRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.19 Description Severity of the virtual disk state. This is the combined status of the virtual disk and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Virtual Disk Component Status Name virtualDiskComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.
book.book Page 665 Monday, March 14, 2011 3:01 PM Virtual Disk Nexus ID Name virtualDiskNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.21 Description Durable unique ID for this virtual disk. Syntax DisplayString Access Read-only Virtual Disk Array Disk Type Name virtualDiskArrayDiskType Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.22 Description Identifies the type of array (physical) disks used to create the virtual disk.
book.book Page 666 Monday, March 14, 2011 3:01 PM Virtual Disk Encrypted Name virtualDiskEncrypted Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.24 Description Indicates if virtual disk is encrypted. Value: 0 - No, 1 - Yes, 99 - Unknown Syntax Integer Access Read-only Virtual Disk is CacheCade Name virtualDiskIsCacheCade Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.25 Description Indicates if this virtual disk is configured as CacheCade.
book.book Page 667 Monday, March 14, 2011 3:01 PM The following object sets up the Array Disk Logical Connection Table. Name arrayDiskLogicalConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.140.3 Description Defines the array disk logical connection table. Syntax SEQUENCE OF arrayDiskLogicalConnectionEntry Access Not accessible Array Disk Logical Connection Entry Name arrayDiskLogicalConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.
book.book Page 668 Monday, March 14, 2011 3:01 PM Array Disk Logical Connection Array Disk Number Name arrayDiskLogicalConnectionArrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.3 Description Identifies the instance number of the array disk in this logical connection. Syntax Integer Access Read-only Array Disk Logical Connection Virtual Disk Name Name arrayDiskLogicalConnectionVirtualDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.
book.book Page 669 Monday, March 14, 2011 3:01 PM Array Disk Logical Connection Disk Number Name arrayDiskLogicalConnectionDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.7 Description Identifies the instance number of the disk group to which this array disk belongs. This property is currently not supported. Syntax Integer Access Read-only Storage Management Event Group The Storage Management Event Group defines the properties that are sent with SNMP traps.
book.book Page 670 Monday, March 14, 2011 3:01 PM Name locationEvent Description Additional information identifying the location of the object causing the alert. Syntax DisplayString Access Read-only Object Name Event Name objectNameEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.4 Description Name of the object as represented in Storage Management causing the alert. Syntax DisplayString Access Read-only Object OID Event Name objectOIDEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.
book.book Page 671 Monday, March 14, 2011 3:01 PM Current Status Event Name currentStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.7 Description Current status of object causing the alert, if applicable. Syntax DellStatus Access Read-only Previous Status Event Name previousStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.8 Description Previous status of object causing the alert if applicable.
book.
book.book Page 673 Monday, March 14, 2011 3:01 PM Change Management Group 25 The Change Management Group lets you monitor information about the Dell devices and software that are present on a particular managed computer chassis. This information is collected during an inventory scan. Inventory Group The following objects describe the fields for inventory information. Inventory Locale Name inventoryLocale Object ID 1.3.6.1.4.1.674.10899.1.1 Description Defines the locale of the system.
book.book Page 674 Monday, March 14, 2011 3:01 PM Name inventorySystemID Access Read-only Device Group The Device Group defines information about the devices discovered on the system during an inventory scan. Identifying information includes the Component ID, the Device ID, and the Vendor ID. Device Group Table The following object sets up the Device Group Table. Name deviceTable Object ID 1.3.6.1.4.1.674.10899.1.5 Description Defines the Device Table.
book.book Page 675 Monday, March 14, 2011 3:01 PM Device Component ID Name deviceComponentID Object ID 1.3.6.1.4.1.674.10899.1.5.1.2 Description Defines an optional component ID field for the device. Syntax Integer Access Read-only Device Display String Name deviceDisplayString Object ID 1.3.6.1.4.1.674.10899.1.5.1.3 Description Provides a displayable string that describes the device. Syntax DisplayString Access Read-only Device Vendor ID Name deviceVendorID Object ID 1.3.6.1.4.1.
book.book Page 676 Monday, March 14, 2011 3:01 PM Device Sub ID Name deviceSubID Object ID 1.3.6.1.4.1.674.10899.1.5.1.6 Description Provides additional device identification. Syntax Octet String Access Read-only Device Sub Vendor ID Name deviceSubVendorID Object ID 1.3.6.1.4.1.674.10899.1.5.1.7 Description Provides additional vendor identification.
book.book Page 677 Monday, March 14, 2011 3:01 PM Application Group Table The following object sets up the Application Group Table. Name applicationTable Object ID 1.3.6.1.4.1.674.10899.1.6 Description Defines a table of application information for the system. Syntax SEQUENCE OF ApplicationEntry Access Not accessible Application Entry Name applicationEntry Object ID 1.3.6.1.4.1.674.10899.1.6.1 Description Defines an application entry.
book.book Page 678 Monday, March 14, 2011 3:01 PM Application Component Type Name applicationComponentType Object ID 1.3.6.1.4.1.674.10899.1.6.1.3 Description Identifies the type of application reported. Syntax DisplayString Access Read-only Application Version Name applicationVersion Object ID 1.3.6.1.4.1.674.10899.1.6.1.4 Description Identifies the version of the application. Syntax DisplayString Access Read-only Application Display String Name applicationDisplayString Object ID 1.
book.book Page 679 Monday, March 14, 2011 3:01 PM Operating System Group The Operating System Group provides status and identifying information about a system’s operating system. Identifying information includes the name, version, and service pack of the installed operating system. The following objects describe the fields for Operating System Group. Operating System Vendor Name operatingSystemVendor Object ID 1.3.6.1.4.1.674.10899.2.1 Description Defines the vendor of the Operating System.
book.book Page 680 Monday, March 14, 2011 3:01 PM Operating System Service Pack Major Version Name operatingSystemSPMajorVersion Object ID 1.3.6.1.4.1.674.10899.2.5 Description Defines the Operating System's Service Pack major version. Syntax DisplayString Access Read-only Operating System Service Pack Minor Version Name operatingSystemSPMinorVersion Object ID 1.3.6.1.4.1.674.10899.2.6 Description Defines the Operating System's Service Pack minor version.
book.book Page 681 Monday, March 14, 2011 3:01 PM Product ID Display Name Name productIDDisplayName Object ID 1.3.6.1.4.1.674.10899.100.1 Description Defines the display name of the product. Syntax DisplayString Access Read-only Product ID Description Name productIDDescription Object ID 1.3.6.1.4.1.674.10899.100.2 Description Provides a description of the product. Syntax DisplayString Access Read-only Product ID Vendor Name productIDVendor Object ID 1.3.6.1.4.1.674.10899.100.
book.book Page 682 Monday, March 14, 2011 3:01 PM Product ID Build Number Name productIDBuildNumber Object ID 1.3.6.1.4.1.674.10899.100.5 Description Describes the software build number of the product.
book.book Page 683 Monday, March 14, 2011 3:01 PM 26 Dell Remote Access Controller Outof-Band Group The Dell Remote Access Controller Out-of-Band MIB contains information for both Chassis Management Controller (CMC) and RAC Legacy Alerting. This MIB consists of information for the following groups: Product Information The following MIB tables define the Dell RAC Out-of-Band group: DRsProductName Name DRsProductName Object ID 1.3.6.1.4.1.674.10892.2.1.1.
book.book Page 684 Monday, March 14, 2011 3:01 PM DRsProductDescription Name DRsProductDescription Object ID 1.3.6.1.4.1.674.10892.2.1.1.3 Description Defines the product description of a chassis management controller. Syntax DellString Access Read-only DRsProductManufacturer Name DRsProductManufacturer Object ID 1.3.6.1.4.1.674.10892.2.1.1.4 Description Defines the product manufacturer of a chassis management controller.
book.book Page 685 Monday, March 14, 2011 3:01 PM DRsProductURL Name DrsProductURL Object ID 1.3.6.1.4.1.674.10892.2.1.1.7 Description Defines the out-of-band UI URL of a chassis management controller. Syntax DellString Access Read-only DRsProductChassisAssetTag Name DRsProductChassisAssetTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.8 Description Defines the Asset Tag of the chassis. Syntax DellString Access Read-only DRsProductChassisLocation Name DRsProductChassisLocation Object ID 1.
book.book Page 686 Monday, March 14, 2011 3:01 PM DRsSystemServiceTag Name DRsSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.11 Description Defines the service tag of a system. Syntax DellString Access Read-only DRsProductSystemAssetTag Name DRsProductSystemAssetTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.12 Description Defines the asset tag of a system. Syntax DellString Access Read-only DRsProductSystemSlot Name DRsProductSystemSlot Object ID 1.3.6.1.4.1.674.10892.2.1.1.
book.book Page 687 Monday, March 14, 2011 3:01 PM DRsFirmwareVersion Name DRsFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.2.1.2.1 Description Defines the firmware version of a chassis management controller. Syntax DellString Access Read-only Chassis Status The following MIB tables provide information on Chassis being monitored by the chassis management card. DRsGlobalSystemStatus Name DRsGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10892.2.2.
book.book Page 688 Monday, March 14, 2011 3:01 PM DRsIOMCurrStatus Name DRsIOMCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.2 Description Defines the IOM subsystem status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsKVMCurrStatus Name DRsKVMCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.3 Description Defines the iKVM subsystem health status being monitored by the chassis management card.
book.book Page 689 Monday, March 14, 2011 3:01 PM DRsPowerCurrStatus Name DRsPowerCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.5 Description Defines the power subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsFanCurrStatus Name DRsFanCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.6 Description Defines the fan subsystem health status being monitored by the chassis management card.
book.book Page 690 Monday, March 14, 2011 3:01 PM DRsTempCurrStatus Name DRsTempCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.8 Description Defines the temperature sensor subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsCMCCurrStatus Name DRsCMCCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.9 Description Defines the CMC health status being monitored by the chassis management card.
book.book Page 691 Monday, March 14, 2011 3:01 PM DRsCMAmbientTemperature Name drsCMCAmbientTemperature Object ID 1.3.6.1.4.1.674.10892.2.3.1.11 Description Defines the ambient temperature reading (in degrees Celsius) for the chassis management card. Syntax DellTemperatureReading Access Read-only DRsCMProcessorTemperature Name drsCMCProcessorTemperature Object ID 1.3.6.1.4.1.674.10892.2.3.1.12 Description Defines the temperature reading (in degrees Celsius) for the chassis management card.
book.book Page 692 Monday, March 14, 2011 3:01 PM DRsIOMPrevStatus Name DRsIOMPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.2 Description Defines the previous IOM subsystem status recorded by the chassis management card. Syntax DellStatus Access Read-only DRsKVMPrevStatus Name DRsKVMPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.3 Description Defines the previous iKVM subsystem health status recorded by the chassis management card.
book.book Page 693 Monday, March 14, 2011 3:01 PM DRsPowerPrevStatus Name DRsPowerPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.5 Description Defines the previous power subsystem health status recorded by the chassis management card. Syntax DellStatus Access Read-only DRsFanPrevStatus Name DrsFanPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.6 Description Defines the previous fan health status being monitored by the chassis management card.
book.book Page 694 Monday, March 14, 2011 3:01 PM DRsTempPrevStatus Name DRsTempPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.8 Description Defines the temperature sensor health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsCMCPrevStatus Name DRsCMCPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.9 Description Defines the CMC health status being monitored by the chassis management card.
book.book Page 695 Monday, March 14, 2011 3:01 PM DRsKVMChangeTime Name DRsKVMChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.3 Description Defines the timestamp of the most recent iKVM status change. Syntax TimeTicks Access Read-only DRsRedChangeTime Name DRsRedChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.4 Description Defines the timestamp of the most recent Redundancy status change. Syntax TimeTicks Access Read-only DRsPowerChangeTime Name DRsPowerChangeTime Object ID 1.3.6.
book.book Page 696 Monday, March 14, 2011 3:01 PM DRsBladeChangeTime Name DRsBladeChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.7 Description Defines the timestamp of the most recent blade health status change. Syntax TimeTicks Access Read-only DRsTempChangeTime Name DRsTempChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.8 Description Defines the timestamp of the most recent temperature sensor health status change.
book.book Page 697 Monday, March 14, 2011 3:01 PM Chassis Power The following MIB tables provide information on the chassis management controller table entry. DRsCMC Power Table Name DRsCMCPowerTable Object ID 1.3.6.1.4.1.674.10892.2.4.1 Description Defines the CMC power table. Syntax SEQUENCE OF DrsCMCPowerTableEntry Access Not-accessible DRsCMC Power Table Entry Name DRsCMCPowerTableEntry Object ID 1.3.6.1.4.1.674.10892.2.4.1.1 Description Defines the CMC power table entry.
book.book Page 698 Monday, March 14, 2011 3:01 PM DRsCMC PSUTableEntry Name DrsCMCPSUTableEntry Object ID 1.3.6.1.4.1.674.10892.2.4.2.1 Description Defines the CMC PSU table entry. Syntax DrsCMCPSUTableEntry Access Not-accessible CMC Power Information The following MIB tables provide information on the chassis power. DRsChassisIndex Name DrsChassisIndex Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.1 Description Defines the index (one-based) of the associated chassis.
book.book Page 699 Monday, March 14, 2011 3:01 PM DRsIdlePower Name DRsIdlePower Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.3 Description Defines the power (in Watts) required by the chassisinfrastructure, plus the sum of the minimum power requirements for all systems currently turned on. Syntax DellPowerReading Access Read-only DRsMaxPowerSpecification Name DRsMaxPowerSpecification Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.
book.book Page 700 Monday, March 14, 2011 3:01 PM DRsKWhCumulative Name DRsKWhCumulative Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.6 Description Defines the cumulative chassis power usage (in KWh) since last reset. Syntax DellPowerReading Access Read-only DRsKWhCumulativeTime Name DRsKWhCumulativeTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.7 Description Defines the timestamp of the most recent chassis power accumulator reset.
book.book Page 701 Monday, March 14, 2011 3:01 PM DRsWattsMinUsage Name DRsWattsMinUsage Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.10 Description Defines the chassis minimum power usage (in Watts) since last reset. Syntax DellPowerReading Access Read-only DRsWattsMinTime Name DRsWattsMinTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.11 Description Defines the timestamp of the most recent chassis minimum power usage.
book.book Page 702 Monday, March 14, 2011 3:01 PM DRsWattsReading Name DRsWattsReading Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.13 Description Defines the instantaneous chassis power usage (in Watts) Syntax DellPowerReading Access Read-only DRsAmpsReading Name DRsAmpsReading Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.14 Description Defines the instantaneous chassis current usage (in Watts).
book.book Page 703 Monday, March 14, 2011 3:01 PM DRsPSUIndex Name DRsPSUIndex Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.2 Description Defines the index (one-based) of the associated CMC PSU. Syntax DellCMCPSUIndexRange Access Read-only DRsPSULocation Name DRsPSULocation Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.3 Description Defines the location of the CMC PSU. Syntax DellString Access Read-only DRsPSUMonitoringCapable Name DRsPSUMonitoringCapable Object ID 1.3.6.1.4.1.674.10892.2.4.2.
book.book Page 704 Monday, March 14, 2011 3:01 PM DRsPSUAmpsReading Name DRsPSUAmpsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.6 Description Defines the instantaneous PSU Current reading. Syntax DellPowerReading Access Read-only DRsPSUWattsReading Name DrsPSUWattsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.7 Description Defines the instantaneous PSU Wattage reading.
book.book Page 705 Monday, March 14, 2011 3:01 PM DrsCASSCurrStatus Name DrsCASSCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.20.10.2 Description Defines the Current Status of the Alerting Sub-System. Syntax DellStatus Access Read-only DrsCASSPrevStatus Name DrsCASSPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.20.10.3 Description Defines the Previous Status of the Alerting Sub-System. Syntax DellStatus Access Read-only DrsCASSChangeTime Name DrsCASSChangeTime Object ID 1.3.6.1.4.1.674.
book.book Page 706 Monday, March 14, 2011 3:01 PM Legacy Alerting The following MIB tables provide information on the RAC legacy alerting. DRsAlertSystem Name DRsAlertSystem Object ID 1.3.6.1.4.1.674.10892.2.5000.10.1 Description Name of the system generating the alert. Syntax Octet String(SIZE (0..255)) Access Read-only DRsAlertTableIndexOID Name DRsAlertTableIndexOID Object ID 1.3.6.1.4.1.674.10892.2.5000.10.2 Description Alert Index Object Identifier.
book.book Page 707 Monday, March 14, 2011 3:01 PM DRsAlertCurrentStatus Name DRsAlertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.2.5000.10.4 Description Current status of object causing the alert. Syntax DellStatus Access Read-only DRsAlertPreviousStatus Name DRsAlertPreviousStatus Object ID 1.3.6.1.4.1.674.10892.2.5000.10.5 Description Previous status of object causing the alert. Syntax DellStatus Access Read-only DRsAlertData Name DRsAlertData Object ID 1.3.6.1.4.1.674.10892.2.
book.
book.book Page 709 Monday, March 14, 2011 3:01 PM Traps 27 The Server Administrator generates events that result in Simple Network Management Protocol (SNMP) traps or operating system event logs. Remote Access Controller (RAC) and Baseboard Management Controller (BMC) can also generate SNMP traps in response to hardware events. This section describes the traps, also known as alerts, generated by the Server Administrator, RAC, and BMC.
book.book Page 710 Monday, March 14, 2011 3:01 PM Trap Variables This section describes the variables that are sent to the management console to provide additional information about a trap or alert generated by some event on your system. The trap variables presented here apply to all Instrumentation and RAC traps. Trap variables are sent in the order listed and are reserved for use only in traps.
book.book Page 711 Monday, March 14, 2011 3:01 PM Current Status Variable Name alertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.1.5000.10.4 Description Gives the current status of the object causing the alert. Syntax DellStatus Previous Status Variable Name alertPreviousStatus Object ID 1.3.6.1.4.1.674.10892.1.5000.10.5 Description Gives the previous status of the object causing the alert. Syntax DellStatus Data Variable Name alertData Object ID 1.3.6.1.4.1.674.10892.1.5000.10.
book.book Page 712 Monday, March 14, 2011 3:01 PM Table 27-1.
book.book Page 713 Monday, March 14, 2011 3:01 PM Table 27-1. Trap Description Reference (continued) Description Line Item Explanation Current sensor value (in Amps): Specifies the current sensor value in amps, for example: Current sensor value: 7.853 Specifies the date and time that an automatic Date and time of action: server recovery action was performed, for example: Date and time of action: Fri May 30 23:55:44 2003.
book.book Page 714 Monday, March 14, 2011 3:01 PM Table 27-1.
book.book Page 715 Monday, March 14, 2011 3:01 PM Table 27-1.
book.book Page 716 Monday, March 14, 2011 3:01 PM Understanding Trap Severity Traps often contain information about values recorded by probes or sensors. Probes and sensors monitor critical components for values such as amperage, voltage, and temperature.
book.book Page 717 Monday, March 14, 2011 3:01 PM Table 27-2. Miscellaneous Traps Trap Description ID Severity Cause System Up 1001 Server Administrator startup complete Information Server Administrator completed its initialization. Thermal Shutdown 1004 Thermal shutdown protection has been initiated Error This message is generated when a system is configured for thermal shutdown due to an error event.
book.book Page 718 Monday, March 14, 2011 3:01 PM Table 27-2. Miscellaneous Traps (continued) Trap Description ID Severity Cause System Peak Power New Peak 1013 System Peak Power detected new peak value Information This message is generated when the system peak power sensor has detected a new peak value. Peak value (in Watts): System Software Event 1014 System software Minor event has occured. Description: This message is generated when a system software event occurs.
book.book Page 719 Monday, March 14, 2011 3:01 PM Table 27-3. Temperature Probe Traps Trap ID Description Severity Cause Temperature Probe Normal 1052 Information A temperature sensor on the backplane board, system board, Sensor location: or drive carrier in the specified system Chassis location: returned to a valid range after crossing a failure threshold.
book.book Page 720 Monday, March 14, 2011 3:01 PM Table 27-3. Temperature Probe Traps (continued) Trap ID Description Severity Cause Error A temperature sensor on the backplane board, system board, or drive carrier in the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and temperature sensor value are provided.
book.book Page 721 Monday, March 14, 2011 3:01 PM Cooling Device Traps Cooling device traps monitor how well a fan is functioning. Table 27-4.
book.book Page 722 Monday, March 14, 2011 3:01 PM Table 27-4. Cooling Device Traps (continued) Trap ID Description Severity Cause Error A fan sensor in the specified system detected the failure of one or more fans. The sensor location, chassis location, previous state, and fan sensor value are provided. Error A fan sensor detected an error from which it cannot recover. The sensor location, chassis location, previous state, and fan sensor value are provided.
book.book Page 723 Monday, March 14, 2011 3:01 PM Voltage Probe Traps Voltage probes monitor the number of volts across critical components. Table 27-5. Voltage Probe Traps Trap ID Description Severity Cause Voltage Probe Normal 1152 Information A voltage sensor in the specified system returned to a valid range Sensor location: after crossing a failure threshold.
book.book Page 724 Monday, March 14, 2011 3:01 PM Table 27-5. Voltage Probe Traps (continued) Trap ID Description Severity Cause Error A voltage sensor in the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and voltage sensor value are provided. Error A voltage sensor in the specified system detected an error from which it cannot recover. The sensor location, chassis location, previous state, and voltage sensor value are provided.
book.book Page 725 Monday, March 14, 2011 3:01 PM Amperage Probe Traps Amperage probes measure the amount of current (in amperes) that is traversing critical components. Table 27-6. Amperage Probe Traps Trap ID Description Severity Cause Amperage Probe Normal 1202 Information A current sensor on the power supply for the specified system Sensor location: returned to a valid range after crossing a failure Chassis location:
book.book Page 726 Monday, March 14, 2011 3:01 PM Table 27-6. Amperage Probe Traps (continued) Trap ID Description Severity Cause Error A current sensor on the power supply for the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and current sensor value are provided. Error A current sensor in the specified system detected an error from which it cannot recover.
book.book Page 727 Monday, March 14, 2011 3:01 PM Chassis Intrusion Traps Chassis intrusion traps are a security measure. Chassis intrusion means that someone is opening the cover to a system’s chassis. Alerts are sent to prevent unauthorized removal of parts from a chassis. Table 27-7.
book.book Page 728 Monday, March 14, 2011 3:01 PM Redundancy Unit Traps Redundancy means that a system chassis has more than one of certain critical components. Fans and power supplies, for example, are so important for preventing damage or disruption of a computer system that a chassis may have extra fans or power supplies installed. Redundancy allows a second or nth fan to keep the chassis components at a safe temperature when the primary fan has failed.
book.book Page 729 Monday, March 14, 2011 3:01 PM Table 27-8. Redundancy Unit Traps (continued) Trap ID Description Severity Cause Warning A redundancy sensor in the specified system detected that one of the components of the redundancy unit has failed but the unit is still redundant. The redundancy unit location, chassis location, and previous redundancy state are provided.
book.book Page 730 Monday, March 14, 2011 3:01 PM Power Supply Traps Power supply traps provide status and warning information for power supplies present in a particular chassis. Table 27-9.
book.book Page 731 Monday, March 14, 2011 3:01 PM Table 27-9. Power Supply Traps (continued) Trap ID Description Severity Cause Power Supply Warning 1353 Power supply detected a Warning warning Sensor location: Chassis location: Previous state was: A power supply sensor has detected a warning condition. The sensor location, chassis location, previous state, and additional power supply status information are provided.
book.book Page 732 Monday, March 14, 2011 3:01 PM Table 27-9. Power Supply Traps (continued) Trap ID Description Severity Cause Power Supply Failure 1354 Power supply detected a Error failure Sensor location: Chassis location: A power supply has been disconnected or has failed. The sensor location, chassis location, previous state, and additional information about the power supply event are provided.
book.book Page 733 Monday, March 14, 2011 3:01 PM Table 27-10. Memory Device Messages Trap ID Description 1403 Severity Memory device status is Warning Memory device location: Possible memory module event cause: 1404 Memory device status is Error Memory device location: Possible memory module event cause: Cause A memory device correction rate exceeded an acceptable value.
book.book Page 734 Monday, March 14, 2011 3:01 PM Table 27-11. Fan Enclosure Traps Trap ID Description Severity Cause Fan Enclosure Insertion 1452 Fan enclosure inserted Information into system Sensor location: Chassis location: A fan enclosure has been inserted into the specified system. The sensor location and chassis location are provided.
book.book Page 735 Monday, March 14, 2011 3:01 PM Table 27-12. AC Power Cord Traps Trap ID Description Severity Cause AC Power Cord No Power Nonredundant 1501 AC power cord is not being monitored Sensor location: Chassis location: Information The AC power cord status is not being monitored. This occurs when a system’s expected AC power configuration is set to nonredundant. The sensor location and chassis location information are provided.
book.book Page 736 Monday, March 14, 2011 3:01 PM Table 27-13. Hardware Log Traps Trap ID Description Severity Cause Hardware Log Normal 1552 Log size is no longer near or at capacity Log type: Information The hardware log on the specified system is no longer near or at its capacity, usually as the result of clearing the log. The log type information is provided.
book.book Page 737 Monday, March 14, 2011 3:01 PM Table 27-14. Processor Device Status Traps Trap ID Description Severity Cause Processor Device Status Normal 1602 Information A processor sensor in the specified system transitioned back to a normal state. The sensor Sensor Location: location, chassis location, previous state and processor Chassis Location:
book.book Page 738 Monday, March 14, 2011 3:01 PM Table 27-14. Processor Device Status Traps (continued) Trap ID Description Severity Cause Error A processor sensor in the specified system is disabled, has a configuration error, or experienced a thermal trip. The sensor location, chassis location, previous state and processor sensor status are provided.
book.book Page 739 Monday, March 14, 2011 3:01 PM Table 27-15. Pluggable Device Traps (continued) Trap ID Description Severity Cause Pluggable Device Removal 1652 Device removed from system Information A device was removed from the specified system. The Device Location: device location, chassis location, and additional Chassis Location: are provided.
book.book Page 740 Monday, March 14, 2011 3:01 PM Table 27-16. Battery Traps Trap ID Description Severity Cause Battery Normal 1702 Battery sensor returned Information to a normal value Sensor Location: Chassis Location: Previous state was: A battery sensor in the specified system detected that a battery transitioned back to a normal state. The sensor location, chassis location, previous state, and battery sensor status are provided.
book.book Page 741 Monday, March 14, 2011 3:01 PM Table 27-16. Battery Traps (continued) Trap ID Description Severity Cause Battery Failure 1704 Battery sensor detected Critical a failure value Sensor Location: Chassis Location: A battery sensor in the specified system detected that a battery has failed. The sensor location, chassis location, previous state, and battery sensor status are provided.
book.book Page 742 Monday, March 14, 2011 3:01 PM RAC Traps This section describes the traps that are generated by the SNMP agent of the Remote Access Controller (RAC). All of the enterprise-specific traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.674.10892.2 and are sent with all of the trap variables documented in the section "Traps" on page 709. The trap variables are sent in the order in which they are listed. Table 27-18.
book.book Page 743 Monday, March 14, 2011 3:01 PM Table 27-19.
book.book Page 744 Monday, March 14, 2011 3:01 PM Table 27-19. Enterprise-specific Traps (continued) Trap ID Name 1005 alertDrscPower The RAC Critical Off has detected a system power state change to poweredoff Error RAC DRAC III detected a system power state change to power-off. 1006 alertDrscPower The RAC Information Error On has detected a system power state change to powered-on RAC DRAC III detected a system power state change to power-on.
book.book Page 745 Monday, March 14, 2011 3:01 PM Table 27-19. Enterprise-specific Traps (continued) Trap ID Name Description Severity Category Cause Supported by RAC Platform 1008 alertDrscBatt Low The RAC Minor Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 8-10 minutes Error DRAC III 1009 Information Status alertDrscTemp The RAC Temperature Normal probe has returned to a normal value RAC DRAC III temperature probe reading returned to normal.
book.book Page 746 Monday, March 14, 2011 3:01 PM Table 27-19. Enterprise-specific Traps (continued) Trap ID Name Description Severity 1012 alertDrscVolt Normal The RAC voltage has returned to a normal value Information Error 1013 alertDrscVolt Warning The RAC Minor voltage probe has detected a warning value Error RAC voltage DRAC III probe reading exceeded warning threshold.
book.book Page 747 Monday, March 14, 2011 3:01 PM Table 27-19. Enterprise-specific Traps (continued) Trap ID Name Description Severity 1016 alertDrscSEL Critical The RAC Critical has detected a new event in the System Event Log with Severity: Critical 1017 alertDrscSEL The RAC 80 system percentFull event log is 80% full 1018 1019 Category Cause Supported by RAC Platform Error RAC All detected a new system event log with critical severity (detailed log info is in drsAlert Message varbind).
book.book Page 748 Monday, March 14, 2011 3:01 PM Table 27-19. Enterprise-specific Traps (continued) Trap ID Name Description Severity Category Cause 1020 alertDrscSEL Normal The RAC Information Error has detected a new event in the System Event Log with Severity: Normal Supported by RAC Platform RAC All detected a new system event log with normal severity (detailed log info is in drsAlert Message varbind).
book.book Page 749 Monday, March 14, 2011 3:01 PM Table 27-20.
book.book Page 750 Monday, March 14, 2011 3:01 PM Table 27-20.
book.book Page 751 Monday, March 14, 2011 3:01 PM Table 27-20.
book.book Page 752 Monday, March 14, 2011 3:01 PM Table 27-20.
book.
book.
book.book Page 755 Monday, March 14, 2011 3:01 PM Storage Management Alert Reference 28 Storage Management’s alert or event management features let you monitor the health of storage resources such as controllers, connectors, array disks, and virtual disks. Alert Monitoring and Logging The Storage Management Service performs alert monitoring and logging. By default, the Storage Management Service starts when the managed system starts up.
book.book Page 756 Monday, March 14, 2011 3:01 PM Viewing Alerts Storage Management generates alerts that are added to the Windows application alert log and to the Server Administrator Alert log. To view these alerts in Server Administrator: 1 Select the System object in the tree view. 2 Select the Logs tab. 3 Select the Alert subtab. You can also view these alerts in the Windows Event Viewer. Every alert consists of the following: • Severity — Shows the severity of alert.
book.book Page 757 Monday, March 14, 2011 3:01 PM The alert severity levels are as follows: Table 28-1. Storage Management Alert Severity Alert Severity Component Status OK/Normal/Informational No action is required. The alert is provided for informational purposes and does not indicate an error condition. For example, the alert may indicate the normal start or stop of an operation. Warning/Non-critical A component requires attention.
book.book Page 758 Monday, March 14, 2011 3:01 PM The Windows SNMP service must be configured to forward the SNMP traps to the target system or application. When forwarding to an application, the application should also be configured to receive the SNMP traps. The IT Assistant application is already configured to receive the SNMP traps generated by Storage Management. See your Windows operating system documentation for information on configuring the operating system to forward SNMP traps.
book.book Page 759 Monday, March 14, 2011 3:01 PM Viewing SNMP Traps SNMP traps that are generated by Storage Management can be viewed in any standard SNMP-compatible enterprise management console. These traps are defined in the Storage Management MIB. These traps correspond to the alerts documented in the “Alert Descriptions and Corrective Actions” section. For more information on the MIB and its structure, as well as a change history of the SNMP traps, see the "Introduction" on page 15 section.
book.
book.book Page 761 Monday, March 14, 2011 3:01 PM 29 Standard Data Type Definitions This appendix contains definitions for data types that are standard in most contexts across the information technology industry. These are the most common data types for describing variable values defined in the 10892.mib, dcs3rmt.mib and dcs3fru.mib files. Server Administrator-specific variable values are defined in the last section of the section in which they are introduced.
book.book Page 762 Monday, March 14, 2011 3:01 PM Variables with Data Types of State Capabilities and State Capabilities Unique Variables with definitions of StateCapabilities or StateCapabilitiesUnique are integers representing a series of bit definitions. They are NOT enumerations and should be treated as bit fields. The value is passed as a decimal value. The decimal value should be converted to hex and the appropriate bits should be parsed from hex.
book.book Page 763 Monday, March 14, 2011 3:01 PM Table 29-3. Dell State Settings Variable Name: DellStateSettings Data Type: Integer Possible Data Values Meaning of Data Value if set to zero(0) The object has no settings capabilities and its state is disabled. unknown(1) The object’s state is unknown. enabled(2) The object’s state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReady(4) The object is not ready.
book.book Page 764 Monday, March 14, 2011 3:01 PM Dell Status Data Types Status data types include DellStatus, DellStatusRedundancy, and DellStatusProbe. Table 29-5. Dell Status Variable Name: DellStatus Data Type: Integer Possible Data Values Meaning of Data Value other(1) The object’s status is not one of the following: unknown(2) The object’s status is unknown. ok(3) The object’s status is OK. nonCritical(4) The object’s status is warning, noncritical.
book.book Page 765 Monday, March 14, 2011 3:01 PM Table 29-7. Dell Status Probe Variable Name: DellStatusProbe Data Type: Integer Possible Data Values Meaning of Data Value other(1) The object’s status is not one of the following: unknown(2) The status of the object is unknown. ok(3) The status of the object is OK. nonCriticalUpper(4) The object is at the noncritical upper limit. CriticalUpper(5) The object is at the critical upper limit.
book.book Page 766 Monday, March 14, 2011 3:01 PM Full Dates Variable Name: DellDateName Data Type: DisplayString DisplayString (SIZE (25)) Full dates are defined in the ASCII format: yyyyMMddhhmmss.uuuuuu+fff or yyyyMMddhhmmss.uuuuuu-fff where yyyy is the year, MM is the month, dd is the day, hh are the hours, mm are the minutes, and ss are the seconds. uuuuuu is the number of microseconds, and +fff or -fff is the offset from UTC in minutes.
book.book Page 767 Monday, March 14, 2011 3:01 PM 30 SNMP Sample Output This appendix contains the sample output from the Simple Network Management Protocol (SNMP) covering the first four groups of the Instrumentation management information base (MIB) sample output from the Simple Network Management Protocol (SNMP) covers the first four groups of the Instrumentation management information base (MIB).
book.book Page 768 Monday, March 14, 2011 3:01 PM 1.3.6.1.4.1.674.10892.1.100.8.0 'https://1.2.3.4:1311' = 1.3.6.1.4.1.674.10892.1.100.9.0 = 'en_US' 1.3.6.1.4.1.674.10892.1.100.10.0 = '2.2.0' 1.3.6.1.4.1.674.10892.1.100.11.0 = 0 1.3.6.1.4.1.674.10892.1.100.12.0 = 1 1.3.6.1.4.1.674.10892.1.100.13.0 = 'Dell Inc.' 1.3.6.1.4.1.674.10892.1.200.10.1.1.1 = 1 1.3.6.1.4.1.674.10892.1.200.10.1.2.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.3.1 = 2 1.3.6.1.4.1.674.10892.1.200.10.1.4.1 = 3 1.3.
book.book Page 769 Monday, March 14, 2011 3:01 PM 1.3.6.1.4.1.674.10892.1.200.10.1.22.1 '\03\03\03\03\03' = 1.3.6.1.4.1.674.10892.1.200.10.1.23.1 '\02\02\02\02\02\02' = 1.3.6.1.4.1.674.10892.1.200.10.1.24.1 = 1.3.6.1.4.1.674.10892.1.200.10.1.25.1 '\03\03\03\03\03\03' = 1.3.6.1.4.1.674.10892.1.200.10.1.26.1 '\02\02\02\02' = 1.3.6.1.4.1.674.10892.1.200.10.1.27.1 = 1.3.6.1.4.1.674.10892.1.200.10.1.28.1 '\03\03\03\03' = 1.3.6.1.4.1.674.10892.1.200.10.1.29.1 = '\02' 1.3.6.1.4.1.674.10892.1.200.
book.book Page 770 Monday, March 14, 2011 3:01 PM 1.3.6.1.4.1.674.10892.1.300.10.1.9.1 2650' = 'PowerEdge 1.3.6.1.4.1.674.10892.1.300.10.1.10.1 = 'ASSETTAG' 1.3.6.1.4.1.674.10892.1.300.10.1.11.1 = '1234567' 1.3.6.1.4.1.674.10892.1.300.10.1.12.1 = 254 1.3.6.1.4.1.674.10892.1.300.10.1.13.1 = 289 1.3.6.1.4.1.674.10892.1.300.10.1.14.1 = 4 1.3.6.1.4.1.674.10892.1.300.10.1.15.1 = 'SERVER01' 1.3.6.1.4.1.674.10892.1.300.10.1.16.1 '20050513095213.000000-360' = 1.3.6.1.4.1.674.10892.1.300.10.
book.book Page 771 Monday, March 14, 2011 3:01 PM 1.3.6.1.4.1.674.10892.1.300.10.1.31.1 = 15 1.3.6.1.4.1.674.10892.1.300.10.1.32.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.33.1 = 27 1.3.6.1.4.1.674.10892.1.300.10.1.34.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.35.1 = 1 1.3.6.1.4.1.674.10892.1.300.10.1.36.1 = 480 1.3.6.1.4.1.674.10892.1.300.10.1.37.1 = 1 1.3.6.1.4.1.674.10892.1.300.10.1.38.1 = 2 1.3.6.1.4.1.674.10892.1.300.10.1.39.1 = 2 1.3.6.1.4.1.674.10892.1.300.10.1.44.1 = 0 1.3.6.
book.
book.
book.
book.
book.
book.
book.