Reference Guide

Phys Disk HDB PD20 ready no no optimal 6 Z1P26QBM
no 2 TB Encl - 1
Phys Disk HDB PD21 ready no no optimal 7 Z1P1R6T3
no 2 TB Encl - 1
Phys Disk HDB PD22 ready no no optimal 8 Z1P26TK6
no 2 TB Encl - 1
Phys Disk HDB PD23 ready no no optimal 9 Z1P26MZ8
no 2 TB Encl - 1
Phys Disk HDB PD24 ready no no optimal 10 Z1P27C4S
no 2 TB Encl - 1
Phys Disk HDB PD25 ready no no optimal 11 Z1P1WR0F
no 2 TB Encl - 1
Component Signature Health Name NexusId
EMM HDB EM00 optimal "EMM 0" "\\1\\0\\0\\0"
EMM HDB EM01 optimal "EMM 1" "\\1\\0\\0\\1"
Component Signature Health Name Vendor
PartNumber
Power Supply HDB EP00 optimal "Power Supply 1" "DELL"
"0NFCG1A02"
Power Supply HDB EP01 optimal "Power Supply 2" "DELL"
"0NFCG1A02"
Component Signature Health Temp_Reading
Name Vendor
Temperature Probe HDB ET00 optimal 27.0 "Temperature
Probe 0" "DELL"
Temperature Probe HDB ET01 optimal 29.0 "Temperature
Probe 1" "DELL"
Temperature Probe HDB ET02 optimal 21.0 "Temperature
Probe 2" "DELL"
Temperature Probe HDB ET03 optimal 21.0 "Temperature
Probe 3" "DELL"
Component Signature Health Speed Name Vendor
Fan HDB EF00 optimal 0 "0NFCG1A02" "DELL"
Fan HDB EF01 optimal 0 "0NFCG1A02" "DELL"
Fan HDB EF02 optimal 0 "0NFCG1A02" "DELL"
Fan HDB EF03 optimal 0 "0NFCG1A02" "DELL"
system --show [--storage]
Description
Displays the service tag, size, configuration state, RAID level, the percentage used, and the state of the storage type (or
types) installed on a DR Series system.
Syntax
system --show --storage
Result
Type Service Tag RawSize Configured RAIDLevel Used State
Boot 16TGJTR 278.88 GB Yes 1 -- ready
Internal 16TGJTR 8.18 TB Yes 6 2.69% ready
Enclosure-1 DCGTXR1 8.18 TB No -- -- ready
For more information about a system storage, see system --add_storage --enclosure <service tag> and system --show
[--storage] [--type <boot | internal | external>] [--service_tag <service tag>].
81