White Papers
Table Of Contents
- 1 Installing and configuring the DR Series system for use with CommVault Simpana
- 2 Configuring CIFS and NFS containers for CommVault Simpana
- 2.1 Creating containers in the DR Series system
- 2.2 Adding the target container(s) to CommVault Simpana
- 2.2 Setting up a single system environment (DR Series system as NFS disk library)
- 2.3 Setting up a replicated system environment
- 2.4 Using the continuous data replicator to replicate client data to a DR Series container
- 3 Configuring VTL for CommVault Simpana
- 4 Setting up the DR Series system cleaner
- 5 Monitoring deduplication, compression, and performance
- A VTL configuration guidelines
- A.1 Managing VTL protocol accounts and credentials
- A.2 VTL default account summary table
- A.3 Managing VTL media and space use
- A.3.1 General performance guidelines for DMA configuration
- A.3.2 Physical space sizing and planning
- A.3.3 Logical VTL geometry and media sizing
- A.3.4 Media retention and grouping
- A.3.5 VTL media count guidelines
- A.3.6 Adding the VTL media to the container
- A.3.7 Updating CommVault to identify newly added VTL media
- A.3.8 Space reclamation
- B Glossary
![](/manual/dell/dr6000/21-20-19-18-17-16-15-14-13-12-11-10-9-8-7-6-5-4-3-2-1-white-papers-english/images/img-44.png)
43 Setting Up the Dell™ DR Series System as a CIFS or VTL Backup Target on CommVault Simpana |
April 2015
3.1.3 Configuring the iSCSI target – Linux
Before you begin this procedure, ensure that the iSCSI initiator is installed (iscsi-initiator-
utils). For example:
yum install iscsi-initiator-utils ; /etc/init.d/iscsi start
To configure the iSCSI target for Linux, follow these steps.
1. Add the CHAP Authentication details for the DR Series system on the Linux Initiator
as follows:
a. Edit /etc/iscsi/iscsid.conf and un-comment the following line:
node.session.auth.authmethod = CHAP
b. Modify the following lines:
# To set a CHAP username and password for initiator
# authentication by the target(s), uncomment the following
lines:
node.session.auth.username = iscsi_user
node.session.auth.password = St0r@ge!iscsi
2. Set the Discovery Target Node(s) by using this command:
iscsiadm -m discovery -t st -p <IP or IQN of DR>
For example:
iscsiadm -m discovery -t st -p 10.8.230.108
3. Enable logon to the DR Series system iSCSI VTL target(s) by using the following
command:
iscsiadm -m node --portal <IP or IQN of DR:PORT> --login
For example:
iscsiadm -m node --portal "10.8.230.108:3260" --login
4. Display the open session(s) with DR VTL(s) by using the following command:
iscsiadm -m session
For example:
iscsiadm -m session = tcp: [8] 10.8.230.108:3260,1 iqn.1984-
05.com.dell:dr4000.3071067.interoprhel52n1.30
5. Review dmesg or /var/log/messages for details about the tape devices created
upon adding the DR Series system iSCSI VTL.