Administrator Guide

To resolve this issue, reset the Dell PERC H700 BIOS to revise the proper boot order setting to configure the proper boot
LUN to be RAID1. To reset the proper LUN boot order, complete the following steps:
1. Start Restore Manager.
2. Select Option 1 Recover My Appliance.
The OS Virtual Disk is created: Warning Code 2002 dialog is displayed.
3. Click Proceed.
The Operating System installation was successful dialog is displayed.
4. Click Reboot, and during reboot, press Ctrl+R to enter the PERC BIOS.
The PERC BIOS Configuration Utility page is displayed.
5. Select Controller 0: PERC H700 in the list.
6. Press Ctrl+N twice to select the Ctrl Mgmt (Controller Management) tab.
7. Select Ctrl Mgmt, click Select bootable VD, and select VD 0 as the VD0 RAID1.
8. Click Apply, and reboot the DR Series system.
The RM Recover My Appliance mode process will then complete.
卸下或更换硬件
要正确卸下或更换任意 DR Series 系统硬件必须遵守并使用关闭和启动过程的最佳做法。有关全套卸下和更
换过程及其分步说明请参阅
Dell DR Series System Owners ManualDell DR Series 系统所有者手册
有关最佳做法的更多信息请参阅 DR Series 系统正确关闭和启动关闭 DR Series 系统
DR Series 系统正确关闭和启动
DR Series 系统中尝试卸下或更换任何硬件组件之前请确保遵循以下最佳做法正确关闭和启动系统
1. 通过在 System Configuration系统配置页面中选择 Shutdown关闭来关闭 DR Series 系统。
有关更多信息请参阅关闭 DR Series 系统。可用于关闭系统的另一种方法是 DR Series 系统 CLI 命令
system --shutdown
2. 等待 DR Series 系统彻底完成其关闭过程。
关闭过程完成后电源设备状态指示灯将熄灭。
3. 从电源插座中拔下 DR Series 系统电源线插头。
4. 请再等一段时间最多 10 分钟),/或验证系统机箱后面板上的所有绿色和琥珀色 NVRAM LED 都熄灭。
: 如果没有让 NVRAM 超级电容器有足够的时间来放电 DR Series 系统随后启动时NVRAM 状态
将报告 DATA LOSS数据丢失
5. 打开插闩释放锁向后将 DR Series 系统护盖滑离以接触到设备内部组件。
要接触到 DR Series 系统的内部请卸下护盖。有关更多信息请参阅
Dell DR Series System Owners
ManualDell DR Series 系统所有者手册
中的过程。
6.
根据需要卸下和更换系统硬件组件。
7. 装回护盖将系统电源线重新连接到电源插座。
8. 按开机指示灯/电源按钮开启 DR Series 系统。
DR Series 系统 NVRAM
NVRAM DR Series 系统中的现场可换单元 (FRU)。为 NVRAM 双数据速率 (DDR) 内存供电的超级电容器必须在
电源中断期间能够将其内容移动到固态驱动器 (SSD)
120