System Event Message Description/Meaning or Action
NVRAM does not match the data volume. If this is a newly replaced NVRAM, use "maintenance --
hardware --reinit_nvram" to initialize.
Software upgrade is in progress. Informational message. No user intervention is required.
Upgrade did not complete. Retry upgrade after rebooting the appliance.
Upgrade completed successfully. Reboot required. Reboot the system.
Upgrade completed successfully. System coming
online.
Informational message. No user intervention is required.
Unable to set Filesystem Scan Markers. Reboot the system. If problem persist contact Dell Support.
Not enough space to run Filesystem Scan. Please clean-up older diagnostics file(s) and reboot the
system. On reboot, execute "maintenance --filesystem --
start_scan" to start filesystem scan. If the file system scan
fails with not enough space, please contact Dell Support.
Filesystem server is crashing repeatedly in
Maintenance Mode.
Please contact Dell Support.
One or more software package is incompatible, please
upgrade the appliance to rectify the issue.
Please upgrade the system appliance to rectify the issue.
Upgrade the DR Series system appliance (in the
Software
Upgrade page, click Start Upgrade).
NVRAM Controller detected a memory failure
NVRAM Health check in progress, please wait for it to
complete before using the system.
Informational message. No user intervention is required.
NVRAM Health check is required, system will perform
a quick health check
Informational message. No user intervention is required.
Failed to start NVRAM Health check, please reboot the
appliance to recover from this state
Reboot the system.
Appliance encountered O/S issues. Please reboot the
appliance to recover from this condition.
Reboot the system.
High system memory usage detected, system
performance will be sluggish.
System memory usage has returned to an optimal
level.
Informational message. No user intervention is required.
A high level of system process usage has been
detected, if it persists, please collect system
diagnostics.
Informational message. No user intervention is required.
System process usage has returned to an optimal
level.
Informational message. No user intervention is required.
A high-temperature reading has been detected on the
NVRAM PCI controller. System will operate only in a
read-only mode. Please check system airflow.
Informational message. No user intervention is required.