Administrator Guide

To resolve this issue, reset the Dell PERC H700 BIOS to revise the proper boot order setting to configure the proper boot
LUN to be RAID1. To reset the proper LUN boot order, complete the following steps:
1. Start Restore Manager.
2. Select Option 1 Recover My Appliance.
The OS Virtual Disk is created: Warning Code 2002 dialog is displayed.
3. Click Proceed.
The Operating System installation was successful dialog is displayed.
4. Click Reboot, and during reboot, press Ctrl+R to enter the PERC BIOS.
The PERC BIOS Configuration Utility page is displayed.
5. Select Controller 0: PERC H700 in the list.
6. Press Ctrl+N twice to select the Ctrl Mgmt (Controller Management) tab.
7. Select Ctrl Mgmt, click Select bootable VD, and select VD 0 as the VD0 RAID1.
8. Click Apply, and reboot the DR Series system.
The RM Recover My Appliance mode process will then complete.
하드웨어 제거 또는 교체
DR Series 시스템 하드웨어를 올바르게 제거하거나 교체하려면 종료 시작 절차의 모범 사례를 검토하여 활용
해야 합니다. 단계별 지침이 있는 포괄적인 제거 교체 절차를 보려면
Dell DR Series 시스템 소유자 매뉴얼
참조하십시오.
모범 사례에 대한 자세한 내용은 DR Series 시스템: 올바른 종료 시작 DR Series 시스템 종료 참조하십시
.
DR Series 시스템: 올바른 종료 시작
DR Series 시스템에서 하드웨어 구성부품을 분리하거나 교체하기 전에 시스템을 올바르게 종료하고 시작하는
모범 사례를 검토하십시오.
1. System Configuration(시스템 구성) 페이지에서 Shutdown(종료) 선택하여 DR Series 시스템의 전원을 끕니
.
자세한 내용은 DR Series 시스템 종료 참조하십시오. DR Series 시스템 CLI 명령 system --shutdown 사용
하여 종료할 수도 있습니다.
2. DR Series 시스템의 전원이 완전히 꺼질 때까지 기다립니다.
전원이 완전히 꺼지면 전원 공급 장치 상태 표시등이 꺼집니다.
3. 전원 콘센트에서 DR Series 시스템 전원 케이블을 분리합니다.
4. 추가 시간(최대 10) 동안 기다리거나 시스템 섀시의 후면 패널에 있는 녹색 황색 NVRAM LED 모두
있는지 확인합니다.
노트: NVRAM 슈퍼 커패시터를 방전시키지 않으면 나중에 DR Series 시스템의 전원을 NVRAM
태가 데이터 손실 표시됩니다.
5. 분리 래치 잠금 장치를 풀고 DR Series 시스템 덮개를 뒤로 밀어 어플라이언스 내부 구성부품에 액세스합니
.
DR Series 시스템 내부에 액세스하려면 덮개를 제거합니다. 자세한 내용은
Dell DR Series 시스템 소유자
뉴얼
설명된 절차를 참조하십시오.
6. 필요에 따라 시스템 하드웨어 구성부품을 분리하고 교체합니다.
7. 덮개를 다시 장착하고 전원 콘센트에 시스템 전원 케이블을 다시 연결합니다.
8. 전원 켜짐 표시등/전원 단추를 눌러 DR Series 시스템의 전원을 켭니다.
120