Owners Manual

Error Code Message Information
PDR1016
Message Drive <number> is removed from disk drive bay <bay>.
Details The controller detected that the drive was removed.
Action Verify drive installation. Re-seat the failed drive. If the issue
persists, see Getting Help.
PST0128
Message No memory is detected.
Details System BIOS was unable to detect memory in the system.
Action Re-seat the memory modules. If the issue persists, see
Getting Help.
PST0129
Message Memory is detected, but is not configurable.
Details System BIOS detected memory, but was unable to configure
the memory for system operation.
Action Compare system memory installation to supported system
memory configurations.
PSU0001
Message Power supply <number> failed.
Action Remove and reinstall the power supply. If the issue persists,
see Getting Help.
PSU0002
Message A predictive failure detected on power supply <number>.
Details System performance and power redundancy may be
degraded or lost.
Action Remove and reinstall the power supply at the next service
window. If the issue persists, see Getting Help.
PSU0003
Message The power input for power supply <number> is lost.
Details The power supply is installed correctly but an input source is
not connected or is not functional.
Action Verify the input source is attached to the power supply.
Verify the input power is within the operating requirements
for the power supply.
PSU0006
Message Power supply <number> type mismatch.
Details Power supplies should be of the same input type and power
rating.
115