Owners Manual

Error Code Message Information
Action Install matched power supplies and review proper
configuration in this manual.
PSU0016
Message Power supply <number> is absent.
Details The power supply has been removed or has failed.
Action
1. Remove and reinstall the power supply.
2. Check cables and subsystem components in the system
for damage.
3. If the issue persists, see Getting Help.
PSU0031
Message Cannot communicate with power supply <number>.
Details The power supply may operate, however power supply
monitoring is degraded. System performance may be
degraded.
Action Remove and reinstall the power supply. If the issue persists,
see Getting Help.
PSU0032
Message The temperature for power supply <number> is in a warning
range.
Details System performance may be degraded.
Action Check the system operating environment, including airflow
and inlet temperature. Check system logs for temperature
and thermal component failures.
PSU0033
Message The temperature for power supply <number> is outside of
the allowable range.
Details System performance may be degraded.
Action Check the system operating environment, including airflow
and inlet temperature. Check system logs for temperature
and thermal component failures.
PSU0034
Message An under voltage fault detected on power supply <number>.
Details This failure may be the result of an electrical issue with
cables or subsystem components in the system.
Action
1. Remove and reinstall the power supply.
2. Check cables and subsystem components in the system
for damage.
116