Setup Guide

Power
NOTE: This system is also designed to be
connected to IT power systems with a phase
to phase voltage not exceeding 230 V.
Battery
Coin-cell battery 3 V CR2032 Lithium coin cell
Physical
Height 87.3 mm (3.44 inch)
Width
With rack latches 482.4 mm (18.98 inch)
Without rack latches 444 mm (17.08 inch)
Depth (includes bezel) 755.8 mm (29.75 inch)
Weight (maximum) 31.86 kg (70.24 lb)
Weight (empty) 18.78 kg (41.4 lb)
Environmental
NOTE: Your system is capable of 40 °C and 45 °C excursion operation for fresh air cooled data
centers. For more information, see the Owner's Manual at dell.com/support/manuals.
NOTE: For additional information about environmental measurements for specific system
configurations, see dell.com/environmental_datasheets.
Temperature
Maximum Temperature Gradient (Operating
and Storage)
20 °C/h (36 °F/h)
Storage Temperature Limits –40 °C to 65 °C (–40 °F to 149 °F)
Temperature (Continuous Operation)
Temperature Ranges (for altitude less than 950
m or 3117 ft)
10 °C to 35 °C (50 °F to 95 °F) with no direct
sunlight on the equipment.
Humidity Percentage Range 10% to 80% Relative Humidity with 26 °C (78.8 °F)
maximum dew point.
Relative Humidity
Storage 5% to 95% RH with 33 °C (91 °F) maximum dew
point. Atmosphere must be non-condensing at all
times.
Maximum Vibration
Operating 0.26 G
rms
at 5 Hz to 350 Hz (all operation
orientations).
7