Users Guide

40 Installing and Setting Up the DRAC 5
d
Update the IPMI SOL baud rate.
NOTE: To redirect the serial console over LAN, ensure that the SOL baud rate is identical to your managed
system’s baud rate.
e
Click the
Baud Rate
drop-down menu, select the appropriate baud rate, and click
Apply Changes
.
f
Update the
Minimum Required Privilege
. This property defines the minimum user privilege that
is required to use the
Serial Over LAN
feature.
Click the
Channel Privilege Level Limit
drop-down menu, select
User
,
Operator
, or
Administrator
.
g
Click
Apply Changes
.
4
Configure IPMI Serial.
a
In the
Configuration
tab, click
Serial
.
b
In the
Serial Configuration
menu, change the IPMI serial connection mode to the appropriate
setting.
Under
IPMI Serial
, click the
Connection Mode Setting
drop-down menu, select the appropriate
mode.
c
Set the IPMI Serial baud rate.
Click the
Baud Rate
drop-down menu, select the appropriate baud rate, and click
Apply Changes
.
d
Set the Channel Privilege Level Limit.
Click the
Channel Privilege Level Limit
drop-down menu, select
Administrator
,
Operator
, or
User
.
e
Click
Apply Changes
.
f
Ensure that the serial MUX is set correctly in the managed system’s BIOS Setup program.
Restart your system.
During POST, press <F2> to enter the BIOS Setup program.
Navigate to
Serial Communication
.
•In the
Serial Connection
menu, ensure that
External Serial Connector
is set to
Remote
Access Device
.
Save and exit the BIOS Setup program.
Restart your system.
If IPMI serial is in terminal mode, you can configure the following additional settings:
Delete control
Echo control
Line edit