Users Guide

58 Configuring and Using the DRAC 5 Command LIne Console
Only four SSH sessions are supported at any given time. The session timeout is controlled by the
cfgSsnMgtSshIdleTimeout property as described in the "DRAC 5 Property Database Group and
Object Definitions."
You can enable the SSH on the DRAC 5 with the command:
racadm config -g cfgSerial -o cfgSerialSshEnable 1
You can change the SSH port with the command:
racadm config -g cfgRacTuning -o cfgRacTuneSshPort <port number>
For more information on cfgSerialSshEnable and cfgRacTuneSshPort properties, see
"DRAC 5 Property Database Group and Object Definitions."
The DRAC 5 SSH implementation supports multiple cryptography schemes, as shown in Table 3-6.
NOTE: SSHv1 is not supported.
Enabling Additional DRAC 5 Security Options
To prevent unauthorized access to your remote system, the DRAC 5 provides the following features:
IP address filtering (IPRange) — Defines a specific range of IP addresses that can access the DRAC 5.
IP address blocking — Limits the number of failed login attempts from a specific IP address
Table 3-6. Cryptography Schemes
Scheme Type Scheme
Asymmetric Cryptography Diffie-Hellman DSA/DSS 512-1024
(random) bits per NIST specification
Symmetric Cryptography
AES256-CBC
RIJNDAEL256-CBC
AES192-CBC
RIJNDAEL192-CBC
AES128-CBC
RIJNDAEL128-CBC
BLOWFISH-128-CBC
3DES-192-CBC
•ARCFOUR-128
Message Integrity
•HMAC-SHA1-160
•HMAC-SHA1-96
HMAC-MD5-128
HMAC-MD5-96
Authentication
•Password