Users Guide

86 Configuring the DRAC 5 Using the Web User Interface
Configuring Serial and Terminal Modes
Configuring IPMI and RAC Serial
1
Expand the
System
tree and click
Remote Access
.
2
Click the
Configuration
tab and then click
Serial
.
3
Configure the IPMI serial settings.
Table 4-27 provides information about the IPMI serial settings.
4
Configure the RAC serial settings.
Table 4-28 provides information about the RAC serial settings.
5
Click
Apply Changes
.
6
Click the appropriate
Serial Configuration
page button to continue. See Table 4-29.
Val id Fr om Issue date of the certificate
Val id To Expiration date of the certificate
Table 4-26. View Server Certificate Page Buttons
Button Description
Print Print the View Server Certificate page.
Go Back to SSL Main Menu Return to the SSL Main Menu page.
Table 4-27. IPMI Serial Settings
Setting Description
Connection Mode Setting
Direct Connect Basic Mode - IPMI Serial Basic Mode
Direct Connect Terminal Mode - IPMI Serial Terminal Mode
Baud Rate Sets the data speed rate. Select 9600 bps, 19.2 kbps, 57.6 kbps, or
115.2 kbps.
Flow Control
None — Hardware Flow Control Off
RTS/CTS — Hardware Flow Control On
Channel Privilege Level
Limit
•Administrator
•Operator
•User
Table 4-25. Certificate Information
(continued)
Field Description