Configuring the DRAC 5 Using the Web User Interface 87
Configuring Terminal Mode
1
Expand the
System
tree and click
Remote Access
.
2
Click the
Configuration
tab and then click
Serial
.
3
In the
Serial Configuration
page, click
Terminal Mode Settings
.
4
Configure the terminal mode settings.
Table 4-30 provides information about the terminal mode settings.
5
Click
Apply Changes
.
6
Click the appropriate
Terminal Mode Settings
page button to continue. See Table 4-31.
Table 4-28. RAC Serial Settings
Setting Description
Enabled Enables or disables the RAC serial console. Checked=Enabled;
Unchecked=Disabled
Maximum Sessions The maximum number of simultaneous sessions allowed for this system.
Timeout The maximum number of seconds of line idle time before the line is
disconnected. The range is 60 to 1920 seconds. Default is 300 seconds. Use
0 seconds to disable the Timeout feature.
Redirect Enabled Enables or disables Console Redirection. Checked=Enabled; Unchecked=
Disabled
Baud Rate The data speed on the external serial port. Values are 9600 bps, 28.8 kbps,
57.6 kbps, and 115.2 kbps. Default is 57.6 kbps.
Escape Key Specifies the <Esc> key. The default are the ^\ characters.
History Buffer Size The size of the serial history buffer, which holds the last characters written to
the console. The maximum and default = 8192 characters.
Login Command The DRAC command line to be executed upon valid login.
Table 4-29. Serial Configuration Page Settings
Button Description
Print Print the Serial Configuration page.
Refresh Refresh the Serial Configuration page.
Apply Changes Apply the IPMI and RAC serial changes.
Terminal Mode Settings Opens the Terminal Mode Settings page.