Users Guide

NOTE: If there is only one power supply in the system, the power supply redundancy is set to Disabled.
Removable Flash Media — Provides information about the Internal SD Modules; vFlash and Internal Dual SD Module (IDSDM).
When IDSDM redundancy is enabled, the following IDSDM sensor status is displayed — IDSDM Redundancy Status, IDSDM
SD1, IDSDM SD2. When redundancy is disabled, only IDSDM SD1 is displayed.
If IDSDM redundancy is initially disabled when the system is powered on or after an iDRAC reset, the IDSDM SD1 sensor
status is displayed only after a card is inserted.
If IDSDM redundancy is enabled with two SD cards present in the IDSDM, and the status of one SD card is online while the
status of the other card is offline. A system reboot is required to restore redundancy between the two SD cards in the
IDSDM. After the redundancy is restored, the status of both the SD cards in the IDSDM is online.
During the rebuilding operation to restore redundancy between two SD cards present in the IDSDM, the IDSDM status is not
displayed since the IDSDM sensors are powered off.
NOTE: If the host system is rebooted during IDSDM rebuild operation, the iDRAC does not display the IDSDM
information. To resolve this, rebuild IDSDM again or reset the iDRAC.
NOTE: On the Dell 13th generation of PowerEdge servers, the IDSDM rebuild operation is performed in the
background and the system is not halted during the rebuild process. You can check the Lifecycle Controller logs
to view the status of the rebuild operation. On a Dell 12
th
generation PowerEdge server, the system is halted
while the rebuild operation is performed.
System Event Logs (SEL) for a write-protected or corrupt SD card in the IDSDM module are not repeated until they are
cleared by replacing the SD card with a writable or good SD card, respectively.
Temperature — Provides information about the system board inlet temperature and exhaust temperature (only applies to rack
servers). The temperature probe indicates whether the status of the probe is within the preset warning and critical threshold
value.
Voltage — Indicates the status and reading of the voltage sensors on various system components.
The following table provides information about viewing the sensor information using iDRAC web interface and RACADM. For
information about the properties that are displayed on the web interface, see the iDRAC Online Help.
NOTE: The Hardware Overview page displays data only for sensors present on your system.
Table 13. Sensor information using web interface and RACADM
View sensor information For Using web interface Using RACADM
Batteries
OverviewHardwareBatteries
Use the getsensorinfo command.
For power supplies, you can also use the
System.Power.Supply command with the
get subcommand.
For more information, see the iDRAC
RACADM Command Line Interface
Reference Guide
available at dell.com/
idracmanuals.
Fan
OverviewHardwareFans
CPU
OverviewHardwareCPU
Memory
OverviewHardwareMemory
Intrusion
OverviewServerIntrusion
Power Supplies
OverviewHardwarePower
Supplies
Removable Flash Media
OverviewHardwareRemovable
Flash Media
Temperature
OverviewServerPower/Thermal
Temperatures
Voltage
OverviewServerPower/Thermal
Voltages
98