Installing the cooling shroud
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Complete the procedure listed in Before working inside your system.
Steps
Place the shrould in place on the system board and secure the three screws.
Next steps
1. Connect the CPU2 power cable.
2. Install the expansion-card riser module.
3. Complete the procedure listed in After working inside your system.
Related Links
Removing the expansion-card riser module
Installing the expansion-card riser module
Removing the server sled
Installing the server sled
System memory
Your system supports DDR4 registered DIMMs (RDIMMs).
NOTE: MT/s indicates DIMM speed in MegaTransfers per second.
Memory bus operating frequency can be 2400 MT/s, 2133 MT/s, 1866 MT/s, 1600 MT/s, or 1333 MT/s
depending on the following factors:
• System profile selected (for example, Performance Optimized, Custom, or Dense Configuration
Optimized)
• Maximum supported DIMM frequency of the processors
The system contains 12 memory sockets split into four sets — two sets of 4 sockets and two sets of 2
sockets each. Each 4-socket set is organized into two channels and each 2–socket set is organized into
one channel. In each channel of the 4-socket set, the release levers of the first socket are marked white
and the second socket black. In the 2-socket set, each release lever is marked white.
NOTE: DIMMs in sockets A1 – A8 are assigned to processor 1 and DIMMs in sockets B1 – B4 are
assigned to processor 2.