Owners Manual

Option Description
NOTE: The default setting for In-System Characterization is subject to change
in future BIOS releases.
When enabled, In-System Characterization (ISC) executes during POST upon detecting
relevant changes in system conguration to optimize system power and performance. ISC
takes about 20 seconds to execute, and system reset is needed for ISC results to be
applied. The Enabled - No Reboot option executes ISC and continues without applying
ISC results until the next time system reset occurs. The Enabled option executes ISC and
forces an immediate system reset so that ISC results can be applied. It takes the system
longer to be ready due to the forced system reset. When disabled, ISC does not execute.
Dell Wyse P25/P45 BIOS Access Enables or disables the Dell Wyse P25/P45 BIOS Access. This option is set to Enabled by
default.
Power Cycle Request Enables or disables the Power Cycle Request. This option is set to None by default.
iDRAC Settings utility
The iDRAC settings utility is an interface to set up and congure the iDRAC parameters by using UEFI. You can enable or disable various
iDRAC parameters by using the iDRAC settings utility.
NOTE: Accessing some of the features on the iDRAC settings utility needs the iDRAC Enterprise License upgrade.
For more information about using iDRAC, see Dell Integrated Dell Remote Access Controller User's Guide at Dell.com/idracmanuals.
Entering the iDRAC Settings utility
1 Turn on or restart the managed system.
2 Press F2 during Power-on Self-test (POST).
3 On the System Setup Main Menu page, click iDRAC Settings.
The iDRAC Settings screen is displayed.
Changing thermal settings
The iDRAC settings utility enables you to select and customize the thermal control settings for your system.
NOTE
: Selection of thermal prole does not change the default Fan speed. Fan speed automatically changes as per the system
temperature irrespective of the THERMAL PROFILE in eect or select the Custom fan speed option to set it to desired speed.
1 Click iDRAC Settings > Thermal.
2 Under SYSTEM THERMAL PROFILE > Thermal Prole, select one of the following options:
Default Thermal Prole Settings
Maximum Performance (Optimized)
Minimum Power (Performance per Watt Optimized)
3 Under USER COOLING OPTIONS, set the Fan Speed Oset, Minimum Fan Speed, and Custom Minimum Fan Speed.
4 Click Back > Finish > Yes.
44