Specifications

All operational orientations; 40 G ± 5% with pulse duration of 2 msec ± 10% (equivalent to 20 in/sec
[51 cm/sec])
Non-operational
Half sine shock
Tested on all six sides; 160 G ± 5% with pulse duration of 2 msec ± 10% (equivalent to 50 in/sec [127
cm/sec])
Maximum altitude
Operational (maximum,
unpressurized)
15.20 m to 5,000 m (–50 ft to 16,404 ft)
NOTE: The maximum temperature is derated 1°C/305 m (1000 ft) above sea level altitude.
Non-operational (maximum,
unpressurized)
15.20 m to 10,668 m (–50 ft to 35,000 ft)
Operating environment
Temperature range (system)
Operating:
With 0.7 m/s airow: –30°C to 70°C (22°F to 158°F)
Without airow: –30°C to 60°C (22°F to 140°F)
Non-operating–With a maximum temperature gradation of 15°C (59°F) per hour:
With 0.7 m/s airow:40°C to 85°C (40°F to 185°F)
Without airow: –40°C to 85°C (40°F to 185°F)
WARNING: The maximum operating temperature of the Edge Gateway is 60C (140°F).
Do not exceed this maximum temperature while operating the Edge Gateway inside an
enclosure. Internal heating of the Edge Gateway electronics, other electronics, and the
lack of ventilation inside an enclosure can cause the operating temperature of the Edge
Gateway to be greater than the outside ambient temperature. Continuous operation of the
Edge Gateway at temperatures greater than 60C (140°F) may result in an increased
failure rate and a reduction of the product life. Ensure that the maximum operating
temperature of the Edge Gateway when placed inside an enclosure is 60C (140°F) or less.
Temperature range (with
components)
Operating (SD card): –40°C to 85°C (40°F to 185°F)
Operating (eMMC): –40°C to 85°C (40°F to 185°F)
Maximum relative humidity
(non-condensing)
Operating: 10% to 90%–With a maximum temperature gradation of 15°C (59°F) per hour
Non-operating: 5% to 95%–With a maximum temperature gradation of 20°C (68°F) per hour
Pollution degree 2
NOTE: The ambient temperature is based on the free-air environment, system mounting, and certain workload assumptions.
NOTE: An open space of 63.50 mm (2.50 in) is recommended around the Edge Gateway for optimal air circulation.
NOTE: The maximum operating temperature may vary, depending on factors such as air ow, system mounting, software
applications, and so on.
NOTE: The temperature at the center of the exposed base surface must not exceed 82°C (179.6°F).
NOTE: For optimal thermal distribution when mounted, ensure that Edge Gateway is installed as instructed in the supplied
documentation.