Users Guide

Mechanical and environmental specications
Mounting Wall mounted
Connector type SMA male
Antenna color White
Cable type Plenum rated low loss RG58
Cable color White
Mounting bracket Swivel type (plastic)
Mounting bracket length (approximate) 175 mm (6.89 in)
Mounting bracket color Black
Pig tail length 500 mm ± 10 mm (19.69 in ± 0.39 in)
Coaxial cable specication
Impedance 50 ± 2.00 ohms
Structural return loss -16 dB or better from 100-2500 MHz un-terminated sample
(direct bridge method)
Nominal RTL reference -16 dB or better to 6.0 GHz
Dielectric Foam FEP
Dielectric (outer diameter) 2.79 mm ± 0.076 mm (0.110 in ± 0.003 in)
Velocity of propagation 80%
Center conductor Solid copper, 0.94 mm ± 0.025 mm (0.037 in ± 0.001 in)
Shield #1 Foil, aluminium/poly tape, adhered to dielectric
Diameter over foil 3.02 mm ± 0.07 mm (0.119 in ± 0.003 in)
Shield #2 Braid, 90% 36-AWG tin/copper
Outer jacket Plenum PVDF, o-white, lead-free, and UV stable
Outer diameter 4.52 mm ± 0.15 mm (0.178 in ± 0.006 in)
PLENUM rating CMP(ETL)C(ETL)
Attenuation dB/100 feet (nominal reference values)
8.0 dB@ 450 MHz
12.5 dB @900 MHz
19.6 dB@ l.8 GHz
23.6 dB @ 2.5 GHz
23.0 dB @ 3.0 GHz
27.5 dB @ 4.0 GHz
31.0 dB @ 5.0 GHz
35.0 dB @ 6.0 GHz
Installation temperature -20°C (-4°F) to +65°C (149°F)
Operating temperature -30°C (-22°F) to +65°C (149°F)
CC pullout 6 pound-force minimum, 16 pound-force maximum
64