Table 34. Main error events (continued)
Event Code Message Text and
Description
Details and Solution
2052 An open magazine was
detected in one or more
modules.
Ensure that all magazines are inserted and properly locked.
Don’t open magazines by using the emergency release while
the library is operating and the accessor is moving.
2053 An open top cover was
detected.
Ensure that the top cover is inserted and properly locked.
Don’t open top cover by using the emergency release while
the library is operating and the accessor is moving.
2054 An open bottom cover was
detected.
Ensure that the bottom cover is inserted and properly
locked.
Don’t open bottom cover by using the emergency release
while the library is operating and the accessor is moving.
2055 An open unit lock was
detected.
Ensure that all unit locks are properly locked.
Don’t open unit locks by using the emergency release while
the library is operating and the accessor is moving.
2056 Initialization failure due to
picker push pull positioning
error.
Check for obstructions in the horizontal pathway of the
accessor such as a cartridge that is sticking out or a cable that
is impeding progress.
2057 Startup failure due to shipping
lock in incorrect position.
1. Get access to the picker assembly and manually move the
shipping lock lever to either locked or unlocked position.
2. After the shipping lock is moved to the one of the correct
positions, restart the library.
2061 Move failed pulling cartridge
from drive.
Check for labels or cartridge misalignments that would prevent
the cartridge from coming out of the drive.
2062 Move failed inserting cartridge
to drive.
Check for labels or cartridge misalignments that would prevent
the cartridge from moving into the drive.
2063 Move failed positioning picker
in front of drive.
Check for obstructions in the vertical or horizontal pathway of
the accessor. Examples might include a cartridge that isn’t
seated completely in a slot, an accessor isn’t sitting
horizontally level, or a problem with the accessor spooling
cable that is impeding progress.
2064 Library test failed with critical
error.
An unidentied failure occurred. Contact your service
representative.
Chapter 5. Troubleshooting 87