Users Guide

Table 34. Main error events (continued)
Event Code Message Text and
Description
Details and Solution
2066 Library startup process failed
during inventory scan.
Verify that magazines are closed, cartridges are fully seated,
and that no accessor obstructions exist.
Verify that all modules are powered and any expansion
modules are cabled correctly with the interconnect cable.
Verify that a top and bottom cover is properly installed on the
library.
Verify that the module alignment locks (at rear of module)
are in the proper position.
If the accessor moves front to back, but not vertically, the
accessor shipping lock might be positioned incorrectly and
must be moved to either the fully locked or fully unlocked
position.
If the error persists, review library events for information or
restart the library.
2067 For safety reason, the
accessor movement was
halted in place.
Ensure that all magazines, top or bottom covers and unit
locks are inserted and properly locked.
Don’t open magazines by using the emergency release or
remove covers or unit locks while the library is operating and
the accessor is moving.
Ensure that all modules are powered and have the
interconnect cable properly attached.
2068 An emergency stop condition
was detected in one or more
modules and prevented the
accessor from initialization.
Ensure that all magazines, top or bottom covers and unit
locks are inserted and properly locked.
Insert all open magazines and install all necessary covers
and unit locks before the library is powered on.
Ensure that all modules are powered and have the
interconnect cable properly attached.
2069 Initialization failure due to bar
code reader error.
Restart the library and if the error persists, replace the
accessor assembly.
88 Dell EMC ML3 Tape Library: User's Guide