Users Guide

Table 34. Main error events (continued)
Event Code Message Text and
Description
Details and Solution
2080 Cartridge lost while inserting it
into slot/drive.
Check the source/destination element and ensure that no
obstructions are in the pathway of the accessor.
2085 Communication failure to the
Base Module controller board
I2C port expander component
This event is reported if read or write access to I2C port
expanders on the main library controller is failing.
Reboot the library to see if the error persists.
If the error persists, power off the library and reseat the base
module controller.
If the error continues to persist, replace the base module
controller.
2086 Communication failure to the
Expansion Module controller
board I2C port expander
component.
This event is reported if read or write access to I2C port
expanders on expansion controller is failing.
Restart the library to see if the error persists.
If the error persists, power off the library and reseat the
expansion module controller.
If the error continues to persist, replace the expansion
module controller.
2087 Error accessing the backplane
flash memory.
Restart the library and if the error persists, replace the
chassis.
Before the chassis is replaced, ensure that you remove all of
your tape cartridges.
If magazines need to be removed to get access to the tape
cartridges, rst power down the device and then manually
release each magazine. Only one magazine must be opened
at a time.
2089 Incompatible Robotics
Assembly Detected
An incompatible robotics assembly is detected. The robotics
assembly was not powered on to avoid damage to the library.
Power off the library and replace the robotics assembly with a
compatible version.
2092 Locking the accessor
assembly failed during power
down process
Power up the library. In case of accessor failure, error events
are reported at power-up. Look for the proposed solution for
these new errors. If no new errors are reported, the 2092
event can be ignored.
2093 Communication to accessor
controller couldn’t be
established.
Restart the library and if the error persists, replace the
accessor assembly.
2094 An emergency stop condition
was detected in one or more
modules and prevented the
accessor from running the
inventory scan.
Ensure that all magazines, top or bottom covers and unit
locks are inserted and properly locked.
Insert all open magazines and install all necessary covers
and unit locks before powering on the library.
Ensure that all modules are powered and have the
interconnect cable properly attached.
90 Dell EMC ML3 Tape Library: User's Guide