Table 35. Warning events (continued)
Event Code Message Text and Description Details and Solution
4015 Power supply failed. Redundancy is not
available.
Ensure that all power supplies are installed
properly (two per module), and that each
power supply is connected to a valid power
source.
4016 Back up conguration data to base module
failed.
Attempt to save the library conguration,
power cycle the library, and retry the operation.
4017 Restore conguration data from Chassis
failed.
Attempt to save the library conguration,
power cycle the library, and retry the operation.
4019 Drive Firmware bundle upgrade failed.
1. Verify that the rmware le is correct for the
drives.
2. Ensure that the drives are in a healthy state
with no cartridge in the drive.
3. Retry the operation.
4020 Database was reset due to a problem that
prevented the library from powering up.
If the library was restored to default settings,
restore a saved conguration by using a
previously saved cong le.
If no cong le exists, then proceed in
conguring the library.
4021 Drive was hot-removed while in active
status as data transfer device.
Tape drives must be disabled (powered-off)
before they are removed from the Library. In
case of hot removal, this event is created if the
drive was no active LUN master. A similar event
is dened with higher severity (critical) if the
drive was LUN master.
Put the drive back into the library.
Follow the “Removing a tape drive” on page
118 procedure to remove the tape drive.
4022 Drive in wrong position. A full height drive was installed to a drive bay
with even physical number. These positions
can be used only with half height drives
because elements of the parting wall are
covering the medium load area.
4025 Library test failed due to a cartridge error. Remove the cartridge and inspect it for
damage. Retry operation with another
cartridge.
4028 Library Test failed due to incompatible
cartridge.
Check LTO generation for cartridge and drives.
Remove cartridges that aren’t compatible to
your tape drives.
4029 Library Test failed - Cartridge bar code
indicates incompatibility with drive.
Check if Media bar code label is matching LTO
generation. Replace the label or remove
incompatible media from your system.
4030 Move cartridge operation failed due to
cartridge error.
Remove the cartridge and inspect it for
damage. Retry operation with another
cartridge.