Table 35. Warning events (continued)
Event Code Message Text and Description Details and Solution
4041 Library Verify failed because the power
supply redundancy test failed.
Ensure that all power supplies are installed
properly (two per module), and that each
power supply is connected to a valid power
source.
4044 One of the Library tests failed because a
source element or destination element
isn’t accessible.
Verify the source and destination elements and
retry the move operation.
4060 Connection to the KMIP server failed.
Verify the user name and password and all
needed SSL certicates that are needed for
connecting to the KMIP server.
Verify that the KMIP server is reachable
within the network.
Verify the IP addresses and host names of
the KMIP servers that are entered into the
wizard.
If this error happens during the connectivity
check, the additional information parameter
includes further error information received
from the Cryptsoft KMIP library. It also includes
the information if the server wasn't able to
ping.
4061 Key is not found on KMIP server. Verify that the requested key is available on the
KMIP server. Check the KMIP server logs for
details.
4062 Key creation on KMIP server failed. Check the KMIP server logs for details about
why key creation failed.
4063 KMIP conguration invalid. Use the KMIP conguration wizard to verify the
KMIP conguration.
4065 A tape alert flag was reported by a drive. Look for logged TapeAlert flags and see its
description in the “TapeAlert flags” on page
105 section.
4067 Cleaning cartridge will soon expire and
must be replaced.
Replace the cartridge.
4072 No cleaning cartridge in logical library
available for auto cleaning.
Auto cleaning is enabled, but the logical
library contains no labeled cleaning cartridge.
The library was unable to complete the auto
clean function for one or more drives in this
logical library.
Install a valid and labeled cleaning cartridge
into the logical library and then complete a
load and unload on the drive that needs
cleaning to start the auto cleaning.
4073 Medium source element empty. Check the source slot visually and rescan the
inventory. Additionally, check for valid and
readable bar code label.
94 Dell EMC ML3 Tape Library: User's Guide