2. The green light illuminates.
3. When the library is powered on, it inventories the tape cartridges in the magazines, checks the
rmware version on all modules, congures the tape drives, conrms the presence of the existing
modules, and searches for any new modules.
Verifying the installation
1. Verify that the library powers on and initializes correctly, and that the status is Ready.
2. If the UID LEDs are still illuminated, deactivate them by using the Operator Panel or Management GUI.
3. Run Library Verify to ensure that the library is working correctly.
Returning the accessor to the Base Module
If you powered off the library and the accessor did not return to its park position in the Base Module
behind the Operator Panel.
1. Power on the library by pressing Power on the Base Module just below the Operator Panel.
2. Return the accessor to its park position.
3. Power off the library by pressing Power on the Base Module and holding for 5 seconds.
If the accessor is still not in the Base Module, use one of the procedures in the following two sections.
If the accessor is stopped in an Expansion Module that is near the Base Module or is stopped directly
between two modules.
1. Remove the front bezel from the Base Module, the Expansion Module containing the accessor, and
modules in between as needed.
2. Insert a small flat head screwdriver into the screwdriver relief on the right rear bearing block of the
accessor.
Figure 77. Inserting the screwdriver to manually operate the accessor
3. Turn the screwdriver to manually operate the accessor gear train and move the accessor into the Base
Module.
Chapter 6. Upgrading and servicing