Users Guide

The command upgrades the software (SW) on the library. It returns before the SW upgrade process is
started. After the upgrade, a reboot is initiated. The connection is lost during this time frame.
Parameters
Table 108. Parameters
Type Name Description Schema
FormData
SWImage
required
The SW upgrade le le
Responses
Table 109. Responses
HTTP code Description Schema
200 OK No content
401 Access denied - not
authenticated
No content
500 Error occurred at operation. Error
Consumes
multipart/form-data
Security
Table 110. Security
Type Name
apiKey AdminSecurity
Library test
Slot to Slot Test
POST /test/slot2slot
Description
Performs the slot to slot test n times. The number of executions must be dened in the count parameter.
The command returns immediately after the test is started. The progress must be polled by the /test/
status request.
Parameters
Table 111. Parameters
Type Name Description Schema
Body
count
required
The number of test
iterations to perform
Table 112 on page 188
count
Appendix D. REST API for scalable tape libraries
187