Table 15. Location requirements (continued)
Criteria Denition
Air quality
• Place the library in an area with minimal sources of particulate
contamination.
• Avoid areas near frequently used doors and walkways, stacks of supplies
that collect dust, printers, and smoke-lled rooms.
• Excessive dust and debris can damage tapes and tape drive.
Technical specications for this library can be referenced in the following tables.
Physical specications
Table 16. Physical specications
Characteristic Product alone Packaged
Height 133 mm 330 mm
Width 480 mm
1
640 mm
Depth 885 mm
2
1160 mm
Weight
Base module: 20 Kg
Expansion module: 14 Kg
Base module: 25 Kg
Expansion module: 19 Kg
1
Includes front covering of rack rails, allowing for magazine opening clearance.
2
Includes front covering and drive fan.
Electrical specications for one module (base or expansion)
Table 17. Electrical
specications for one module (base or expansion)
Characteristic Specication
Current max. 12.5 A
Voltage 100 - 240 V 50/60 Hz
Power 300 W
Chapter 2. Planning 23