LED Description
FC port status LED
Both o—No light or signal carrier—no module, no cable—for
the media interface
Solid amber—Receiving light or signal carrier, but not yet online
Slow ashing amber, 2-second intervals—Disabled; results of
diagnostics or the portdisable command.
Fast ashing amber, 1/2-second intervals—Error occurred, fault
with port.
Solid green—Online; connected with external device over cable
Slow ashing green, 2-second intervals—Online but segmented;
Loopback cable or incompatible switch.
Fast ashing green, 1/2-second intervals—Internal loopback,
diagnostic.
Flickering green—Online and frames owing through the port.
POST results
The power-on self-test (POST) system check performs each time you start up, reboot, or reset the switch module. During the POST, the
LEDs activate in various indicator patterns.
NOTE: The default POST diagnostic level is 0; therefore, no POST runs by default. To run the post, set the POST diagnostic level
to a nonzero value before powering on the switch module.
After installation, the chassis management application manages the switch module. For specic information about managing the switch
module, see the documentation that comes with your blade server chassis.
To determine whether POST completed successfully or whether any errors were detected:
Verify that the LEDs on the switch module indicate a healthy switch.
If one or more LEDs do not display a healthy state, verify that the LEDs are not set to beacon. To verify the LED state, use the
switchShow command or web Tools.
To verify that the switch module is working correctly, use the blade server management application.
Review the system log for errors.
Any errors detected during POST are written to the system log. This log is accessible through the errShow command.
BOOT results
BOOT includes the following tasks after POST completes:
Performs universal port conguration
Initializes links
Analyzes the fabric. If any ports are connected to other switches, the switch participates in a fabric conguration.
Obtains a domain ID and assigns port addresses.
Constructs unicast routing tables.
Enables normal port operation.
Diagnostic tests
In addition to POST, the fabric OS includes diagnostic tests to help troubleshoot the hardware and rmware. These tests include internal
connections and circuitry, xed media, and the transceivers and cables in use.