Users Guide
Example
OS10(config)# port-group 1/1/8
OS10(conf-pg-1/1/8)#
Supported releases 10.3.1E or later
scale-prole vlan
Congures the L2 VLAN scale prole on a switch.
Syntax
scale-profile vlan
Parameters None
Defaults Not congured
Command Mode CONFIGURATION
Usage Information Use the VLAN scale prole when you scale the number of VLANs so that less memory is consumed. Enable the
scale prole before you congure VLANs on the switch. The scale prole globally applies L2 mode on all VLANs you
create and disables L3 transmission. The no version of the command disables L2 VLAN scaling. To enable L3
routing trac on a VLAN, use the mode L3 command.
Example
OS10(config)# scale-profile vlan
Supported Releases 10.4.0E(X2) or later
show discovered-expanders
Displays the Fabric Expanders attached to a Fabric Switching Engine.
Syntax
show discovered-expanders
Syntax
show discovered-expanders
Parameters None
Command Mode EXEC
Usage Information Use the show discovered-expanders command to verify the auto-discovered Fabric Expanders.
If a Fabric Switching Engine is in SmartFabric mode, it automatically discovers and congures an attached Fabric
Expander:
• Virtual ports on the Fabric Expander and a virtual slot ID are created and mapped to 8x25GE breakout
interfaces in FEM mode on the Fabric Engine.
• The unit ID is automatically discovered.
• Server trac is transmitted through the QSFP28-DD uplink on the Fabric Expander to the Fabric Engine.
If the Fabric Switching Engine is in Full Switch mode, congure the switch using the CLI. You must manually
congure the unit ID of the Fabric Expander (see Virtual ports). The unit ID is also called the virtual slot ID.
Example
OS10# show discovered-expanders
Service- Model Type Chassis- Chassis-slot Port-group Virtual-
tag service-tag Slot-Id
--------------------------------------------------------------------------
403RPK2 MX7116n Fabric 1 SKY003Q A2 1/1/2 71
Expander Module
Interfaces 121