OS10 supports DCBX versions CEE and IEEE2.5.
If ETS and PFC are enabled, DCBX advertises ETS configuration, ETS recommendation, and PFC configuration. When you
configure application-specific parameters such as FCoE or iSCSI to be advertised, DCBX advertises the respective
Application Priority TLVs.
A DCBX-enabled port operates only in a manual role. In this mode, the port operates only with user-configured settings and
does not autoconfigure with DCB settings that are received from a DCBX peer. When you enable DCBX, the port advertises
its PFC and ETS configurations to peer devices but does not accept external, or propagate internal, DCB configurations.
NOTE: OS10 does not support autoupstream and autodownstream DCBX port roles. Hence, DCBX-enabled port
autoconfiguration is not supported.
DCBX detects a misconfiguration on a peer device when DCB features are not compatibly configured with the local switch.
NOTE: Misconfiguration detection is feature-specific because some DCB features support asymmetric (nonidentical)
configurations.
Verify DCBX configuration
Verify the DCBX, PFC, and ETS configurations on an interface, using the appropriate commands.
View DCBX configuration
OS10# show lldp dcbx detail | no-more
E-ETS Configuration TLV enabled e-ETS Configuration TLV disabled
R-ETS Recommendation TLV enabled r-ETS Recommendation TLV disabled
P-PFC Configuration TLV enabled p-PFC Configuration TLV disabled
F-Application priority for FCOE enabled f-Application Priority for FCOE disabled
I-Application priority for iSCSI enabled i-Application Priority for iSCSI disabled
-----------------------------------------------------------------------------------------
-
Interface ethernet1/1/1
Port Role is Manual
DCBX Operational Status is Disabled
Reason: Port Shutdown
Is Configuration Source? FALSE
Local DCBX Compatibility mode is AUTO
Local DCBX Configured mode is AUTO
Peer Operating version is Not Detected
Local DCBX TLVs Transmitted: erpfi
0 Input PFC TLV pkts, 0 Output PFC TLV pkts, 0 Error PFC pkts
0 Input ETS Conf TLV Pkts, 0 Output ETS Conf TLV Pkts, 0 Error ETS Conf TLV Pkts
0 Input ETS Reco TLV pkts, 0 Output ETS Reco TLV pkts, 0 Error ETS Reco TLV Pkts
0 Input Appln Priority TLV pkts, 0 Output Appln Priority TLV pkts, 0 Error Appln
Priority TLV Pkts
Total DCBX Frames transmitted 0
Total DCBX Frames received 0
Total DCBX Frame errors 0
Total DCBX Frames unrecognized 0
Interface ethernet1/1/2
Port Role is Manual
DCBX Operational Status is Disabled
Reason: Port Shutdown
Is Configuration Source? FALSE
Local DCBX Compatibility mode is AUTO
Local DCBX Configured mode is AUTO
Peer Operating version is Not Detected
Local DCBX TLVs Transmitted: erpfi
0 Input PFC TLV pkts, 0 Output PFC TLV pkts, 0 Error PFC pkts
0 Input ETS Conf TLV Pkts, 0 Output ETS Conf TLV Pkts, 0 Error ETS Conf TLV Pkts
0 Input ETS Reco TLV pkts, 0 Output ETS Reco TLV pkts, 0 Error ETS Reco TLV Pkts
0 Input Appln Priority TLV pkts, 0 Output Appln Priority TLV pkts, 0 Error Appln
Priority TLV Pkts
Total DCBX Frames transmitted 0
Total DCBX Frames received 0
Total DCBX Frame errors 0
Total DCBX Frames unrecognized 0