API Guide

location-led system
Changes the location LED of the system.
Syntax
location-led system {node-id | node-id/unit-id} {on | off}
Parameters
node-id | node-id/unit-id Enter the system ID.
on | off Set the system LED to be on or off.
Default Not configured
Command Mode EXEC
Usage
Information
Use this command to change the location LED for the specified system ID.
Example
OS10# location-led system 1 on
OS10# location-led system 1 off
Supported
Releases
10.3.0E or later
show boot
Displays boot partition-related information.
Syntax
show boot [detail]
Parameters detail (Optional) Enter to display detailed information.
Default Not configured
Command Mode EXEC
Usage
Information
Use the boot system command to set the boot partition for the next reboot.
Example
OS10# show boot
Current system image information:
===================================
Type Boot Type Active Standby Next-Boot
-----------------------------------------------------------------------------------
Node-id 1 Flash Boot [B] 10.5.0.0 [A] 10.5.0.0 [B] active
Example (Detail)
OS10# show boot detail
Current system image information detail:
==========================================
Type: Node-id 1
Boot Type: Flash Boot
Active Partition: B
Active SW Version: 10.5.0.0
Active SW Build Version: 10.5.0.270
Active Kernel Version: Linux 4.9.168
Active Build Date/Time: 2019-07-29T23:35:01Z
Standby Partition: A
Standby SW Version: 10.5.0EX
Standby SW Build Version: 10.5.0EX.252
Standby Build Date/Time: 2019-07-27T17:31:55Z
Next-Boot: active[B]
Supported
Releases
10.2.0E or later
1400 Troubleshoot Dell EMC SmartFabric OS10