API Guide

----------------------------------------------------------
Name : L2VxLANUplink
Description : Uplink On L2VxLAN Network770
ID : L2VxLANUplink-770
Media Type : ETHERNET
Native Vlan : 0
Untagged-network :
Networks : Network770
Configured-Interfaces : CAC00N2:ethernet1/1/22:3
----------------------------------------------------------
----------------------------------------------------------
Name : L2VxLANUplink
Description : Uplink On L2VxLAN Network771
ID : L2VxLANUplink-771
Media Type : ETHERNET
Native Vlan : 0
Untagged-network : Network771
Networks :
Configured-Interfaces : CAC00N2:ethernet1/1/22:4
----------------------------------------------------------
----------------------------------------------------------
Name : L3Uplink
Description : Uplink On L3 Network600
ID : L3RUplink-600
Media Type : ETHERNET
Native Vlan : 0
Untagged-network : Network600
Networks :
Configured-Interfaces : AZY1234:ethernet1/1/21:2
----------------------------------------------------------
Supported
Releases
10.5.0.1 or later
show smartfabric validation-errors
Displays all topology validation-error information such as category, subcategory, description, recommended action, severity,
timestamp, EEMI, problem, and recommended link for each error seen.
Syntax
show smartfabric validation-errors
Parameters None
Default None
Command Mode EXEC
Usage
Information
Use the command to view a list of topology validation errors with detailed description about each error.
This command is supported both in Full Switch and SmartFabric modes.
Supported on the MX9116n and MX5108n switches starting in release 10.5.0.1. Also available on SFS-
supported OS10 switches starting in release 10.5.0.3. For supported platforms, see SmartFabric Services
for leaf and spine.
NOTE: The show smartfabric validation-errors CLI command can be executed in any
IOM that is a part of the same cluster.
Example
OS10# show smartfabric validation-errors
----------------------------------------------------------
ErrorKey : d77d0133-f8c8-4cd7-82b5-83266e5361eb-ISL-
[ICL-3_REVERSE]-NotFound-Issue
MessageID :
Description : Unable to validate the SmartFabric because
the VLTi cable for link ICL-3_REVERSE is not connected as per
fabric design 2xMX9116n_Fabric_Switching_Engines_in_same_chassis.
EEMI : NFAB0012
Category : FABRIC_ERROR
Subcategory : ISL_ERROR
SmartFabric Services 141