iii. It is highly recommended to upgrade all the
networking switches (MX9116n and MX5108n) in the
MSM Chassis group to 10.5.0.5. During the upgrade
process, it is not recommended to make any
configuration changes in the chassis-group.
iv. For upgrading the networking switch from 10.4.0E
(R3S or R4S), refer to the Upgrade and Downgrade
section in the existing SmartFabric Release Notes for
additional instructions.
v. For upgrading the networking switches from 10.5.0.x
to 10.5.0.5, it is recommended to upgrade via CLI,
detailed in the "Networking Switch CLI upgrade
procedure" section.
vi. Power cycle the MX7000 chassis after updating all
applicable solution components.
b. Networking I/O Module CLI Upgrade Procedure
i. The master Networking I/O Module should be
upgraded only after all the members in the chassis-
group have completed the upgrade.
ii. If the chassis-group has a mix of MX5108n and
MX9116n, complete the upgrade of the MX5108n
Networking I/O Modules first (non-Master) and then
upgrade the MX9116n Networking I/O Modules.
iii. If multiple Networking I/O Modules are to be
upgraded, ensure not more than two Networking I/O
Modules are upgraded concurrently (and each
Networking I/O Module needs to be part of different
fabrics).
iv. Perform the following steps to upgrade the
Networking I/O Module:
i. (Optional) Backup the current running
configuration to the startup configuration in EXEC
mode.
Table 9. Command Description
Command Description
OS10# copy
running-
configuration
startup-
configuration
Back up the running
configuration to
startup configuration.
ii. Backup the startup configuration in EXEC mode.