120 Dell EMC PowerEdge MX SmartFabric Configuration and Troubleshooting Guide
D Additional information
D.1 Delete a SmartFabric
To remove the SmartFabric using the OME-M console, perform the following steps:
1. Open the OME-M console.
2. From the navigation menu, click Devices > Fabric.
3. Select SmartFabric.
4. Click the Delete button.
5. In the delete fabric dialog box click Yes.
All participating switches reboot to Full Switch mode.
NOTE: Any configuration not completed by the OME-M console is lost when switching between IOM operating
modes.
D.2 Delete an MCM group
To remove an MCM group using the OME-M console, perform the following steps:
1. Open the OME-M console.
2. In the MCM group pane, click the name of the lead chassis.
3. From the Configure menu, select Delete Group.
4. In the Delete Group dialog box, click Confirm.
At this point, the OME-M console removes the MCM group. To manage the chassis, use the individual IP
addresses assigned to each.
D.3 Reset chassis using RACADM
To reset the chassis to factory default settings, perform the following steps:
1. Connect to the MX9002m IP address using SSH. The default username is
root, and the default
password is
calvin.
2. In the RACADM shell, run the
racadm racresetcfg command.
3. The factory reset process is initiated, and a status message displays.
NOTE: The process takes several minutes to complete.
4. Optionally, after the reset process is complete, use the LCD screen to reassign a static IP address.
See Section B.2 for more information.