23 Dell EMC PowerEdge MX SmartFabric Configuration and Troubleshooting Guide
3.7.3 Two MX9116n Fabric Switching Engines in the same chassis
This placement should only be used in environments with a single chassis, with the switches in either slots
A1/A2 or slots B1/B2. A SmartFabric cannot include a switch in Fabric A and a switch in Fabric B.
IOM placement 2 x MX9116n in the same chassis
3.8 Switch-to-Switch cabling
When operating in SmartFabric mode, each switch pair runs a VLT interconnect (VLTi) between them. For the
MX9116n, QSFP28-DD port groups 11 and 12 (eth1/1/37-1/1/40) are used.
For the MX5108n, ports 9 and 10 are used. Port 10 will operate at 40GbE instead of 100GbE because all
VLTi links must run at the same speed.
NOTE: The VLTi ports are not user selectable and the connection topology is enforced by the SmartFabric
engine.
MX9116n SmartFabric VLTi cabling
MX5108n SmartFabric VLTi cabling