Setup Guide
33 Dell EMC PowerEdge MX SmartFabric Configuration and Troubleshooting Guide
CNA partition 1 configuration
10. Select Partition 2 Configuration and set the NIC Mode to Disabled.
11. Set the FCoE Mode to Enabled, then click Back.
CNA partition 2 configuration
12. If present, select Partition 3 Configuration and set all modes to Disabled, then click Back.
13. If present, select Partition 4 Configuration and set all modes to Disabled, then click Back.
14. Click Back, and then Finish.
15. When prompted to save changes, click Yes and then click OK in the Success window.
16. Select the second CNA port and repeat steps in this section for port 2
17. After configuring port 2, click Finish, then Finish.
18. Click Yes to exit and reboot.
5.2 Create a server template
A server template contains parameters extracted from a server and allows these parameters to be quickly
applied to multiple compute sleds. The server template allows an administrator to associate VLANs to
compute sleds. The templates contain settings for the following categories:
• Local access configuration
• Location configuration
• Power configuration
• Chassis network configuration
• Slot configuration
• Setup configuration