Owners Manual
Table Of Contents
- PowerVault NX440 Network Attached Storage System Installation and Service Manual
- Contents
- System overview
- Technical specifications
- Initial system setup and configuration
- Reinstalling the operating system using a DVD
- Diagnostics and indicators
- Pre-operating system management applications
- System Setup
- Viewing System Setup
- System Setup details
- System BIOS
- Viewing System BIOS
- System BIOS Settings details
- System Information
- Viewing System Information
- System Information details
- Memory Settings
- Viewing Memory Settings
- Memory Settings details
- Processor Settings
- Viewing Processor Settings
- Processor Settings details
- SATA Settings
- Viewing SATA Settings
- SATA Settings details
- Boot Settings
- Viewing Boot Settings
- Boot Settings details
- Integrated Devices
- Viewing Integrated Devices
- Integrated Devices details
- Serial Communication
- Viewing Serial Communication
- Serial Communication details
- System Profile Settings
- Viewing System Profile Settings
- System Profile Settings details
- System Security
- Viewing System Security
- System Security Settings details
- Creating a system and setup password
- Using your system password to secure your system
- Deleting or changing system and setup password
- Operating with setup password enabled
- Redundant OS Control
- Viewing Redundant OS Control
- Redundant OS Control screen details
- Miscellaneous Settings
- Viewing Miscellaneous Settings
- Miscellaneous Settings details
- iDRAC Settings utility
- Device Settings
- Dell Lifecycle Controller
- Boot Manager
- PXE boot
- System Setup
- Jumpers and connectors
- Installing and removing system components
- Safety instructions
- Before working inside your system
- After working inside your system
- Front bezel
- Hard Drives
- System cover
- Cooling fans
- Intrusion switch
- System memory
- Expansion cards and expansion card riser
- Storage controller card
- Replacing the system battery
- Replacing the optional internal USB memory key
- Optical drive
- Processor and heat sink
- Drive backplane
- Power supply unit
- Power distribution board
- System board
- Trusted Platform Module
- Control panels
- Getting help
- Documentation resources
Next steps
1. Install the cooling fan or install the cooling fan blank
2. Install the air shroud
Installing a cooling fan
Prerequisites
1. Follow the safety guidelines listed in Safety instructions.
2. Follow the procedures in Before working inside your system.
Steps
1. Lower the cooling fan into the cooling fan cage.
2. Press the release tabs on the fan cable connector and connect the cable from the system board.
NOTE: Route the cable properly to prevent the cable from being pinched or crimped.
Figure 29. Installing a cooling fan
Next steps
1. Install the air shroud.
2. Follow the procedures in After working inside your system.
Intrusion switch
Removing the intrusion switch
Prerequisites
1. Follow the safety guidelines listed in Safety instructions.
2. Follow the procedures in Before working inside your system.
3. Keep the plastic scribe ready.
Steps
1. Disconnect and remove the intrusion switch cable.
Installing and removing system components
61