Users Guide
Table Of Contents
- Dell EMC OpenManage Ansible Modules Version 1.1 User’s Guide
 - Overview
 - Getting Started
 - Updating Firmware
 - Configuring PowerEdge Servers
 - Deploying operating system
 - Server Inventory
 - Server Administration Tasks
 - Troubleshooting
 - Accessing support content from the Dell EMC support site
 
Table 13. dellemc_configure_idrac_timezone (continued)
Parameter Required Default Choices Comments
idrac_pwd Yes NA NA iDRAC user password
idrac_port No 443 NA iDRAC port
share_name Yes NA NA CIFS or NFS Network share or a local path
share_user No NA NA
Network share user in the format
'user@domain' or 'domain\user' if user is
part of a domain else 'user'. This option is
mandatory for CIFS Network share.
share_pwd No NA NA
Network share user password. This option
is mandatory for CIFS Network share.
share_mnt No NA NA
Local mount path of the network share
with read-write permission for Ansible
user. This option is mandatory for CIFS or
NFS Network share.
setup_idrac_timezone No NA NA Configuring the timezone for iDRAC
enable_ntp No NA NA
Whether to Enable or Disable NTP for
iDRAC
ntp_server_1 No NA NA NTP configuration for iDRAC
ntp_server_2 No NA NA NTP configuration for iDRAC
ntp_server_3 No NA NA NTP configuration for iDRAC
Table 14. Return Values 
Name Description Returned Type Sample
iDRAC Timezone
Configures the iDRAC
timezone attributes
Success String
https://github.com/dell/Dell-EMC-Ansible-
Modules-for-iDRAC/blob/master/samples/
dellemc_configure_idrac_timezone.md
Example
-name: Configure the iDRAC timezone attributes
   dellemc_configure_idrac_timezone:
     idrac_ip:             "xx.xx.xx.xx"
     idrac_user:           "xxxx"
     idrac_pwd:            "xxxxxxxx"
     share_name:           "xx.xx.xx.xx:/share"
     share_pwd:            "xxxxxxxx"
     share_user:           "xxxx"
     share_mnt:            "/mnt/share"
     setup_idrac_timezone: "UTC"
     enable_ntp:           "Enabled"
     ntp_server_1:         "x.x.x.x"
     ntp_server_2:         "x.x.x.x"
     ntp_server_3:         "x.x.x.x"
Configuring iDRAC Eventing
Module: dellemc_configure_idrac_eventing
Synopsis
This module configures iDRAC eventing related attributes.
Check_mode support: Yes
Options
16
Configuring PowerEdge Servers