Users Guide
Table Of Contents
- Dell EMC OpenManage Ansible Modules Version 4.0.0 User’s Guide
 - Contents
 - Overview
 - Getting Started
 - Modules for iDRAC
- How OpenManage Ansible Modules work with iDRAC
 - Running your first iDRAC Playbook
 - Updating Firmware
 - Configuring PowerEdge Servers
 - Deploying operating system
 - Server Inventory
 - Server administration tasks
 - Storage controller
 
 - Modules for OpenManage Enterprise (OME)
- How OpenManage Ansible Modules work with OME
 - Running your first OME Playbook
 - Manage Devices
 - Manage device configuration templates
 - Template Service
 - Manage the device firmware
 - Manage jobs
 - Manage users
 - Manage identity pool
 - Manage application settings
 - Manage network configuration
 - Manage fabrics
 - Manage Profiles
 - Device discovery
 - Manage Chassis
 - Manage Active Directory service and user groups
 - Diagnostics
 
 - Modules for Redfish APIs
 - Deprecated modules
 
    }
  }
Examples
- name: Assign a dedicated hot spare
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    volume_id: "Disk.Virtual.0:RAID.Slot.1-1"
    target: "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Slot.1-1"
  tags:
    - assign_dedicated_hot_spare
- name: Assign a global hot spare
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    target: "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Slot.1-1"
  tags:
    - assign_global_hot_spare
- name: Set a controller encryption key
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    command: "SetControllerKey"
    controller_id: "RAID.Slot.1-1"
    key: "PassPhrase@123"
    key_id: "mykeyid123"
  tags:
    - set_controller_key
- name: Rekey in LKM mode
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    command: "ReKey"
    controller_id: "RAID.Slot.1-1"
    key: "PassPhrase@123"
    key_id: "mykeyid123"
    old_key: "OldPassPhrase@123"
  tags:
    - rekey_lkm
- name: Rekey in SEKM mode
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    command: "ReKey"
    controller_id: "RAID.Slot.1-1"
    mode: "SEKM"
  tags:
    - rekey_sekm
- name: Remove the controller key
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    command: "RemoveControllerKey"
    controller_id: "RAID.Slot.1-1"
  tags:
    - remove_controller_key
- name: Reset configuration
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
Modules for iDRAC
55










