Deployment Guide
 -d DOMAIN, --domain DOMAIN
 Domain-Id for the SmartFabric Services cluster
 formation. Accepted Values [1..254].
 -u UPLINK, --uplink UPLINK
 Uplink Interfaces separated by a comma (,). If empty,
 it takes the default value for the platform. If there
 is no uplink, provide 'None/Null'
 -i ICL, --icl ICL VLT Inter Chassis Link(ICL) interfaces seperated by a
 comma (,). If empty, it takes the default value for
 the platform. If there is no icl value (in case of
 single node cluster), input the value as 'None/Null'
 -t, --tagged Flag to indicate if management VLAN is tagged on the
 on the TOR uplink ports. By default Uplinks are not
 tagged. Default management VLAN 1 is untagged on
 Uplink interfaces.
 -a, --active_mode Flag to indicate if LACP is to be enabled on the TOR
 uplink ports to the spine switches. By default lacp on
 TOR uplink ports is not enabled.
 -b {2X50GE,4X25GE,4X10GE}, --breakout_uplink {2X50GE,4X25GE,4X10GE}
 The breakout mode for uplink interfaces.
 -m MANAGEMENT_VLAN, --management_vlan MANAGEMENT_VLAN
 Public Management VLAN (Untagged VLAN). By default
 management VLAN is 1.
 -j JUMPBOX_INTERFACE, --jumpbox_interface JUMPBOX_INTERFACE
 The jumpbox interface.
 -a ADDITIONAL_BREAKOUT, --additional_breakout ADDITIONAL_BREAKOUT
 The additional breakouts of phy-ports or port-groups.
 The format is -a '4X10GE{phy-port1/1/2,phy-
 port1/1/3};1X40GE{phy-port1/1/4,phy-port1/1/5}'. The
 available breakouts are ['1X40GE', '4X10GE'] 
S52xx platform personality profile
root@OS10:~# sfs_enable_vxrail_personality.py -h
usage: Create VxRail Cluster [-h] [-d DOMAIN] [-u UPLINK] [-i ICL] [-t] [-l]
 [-b 
{4X50GE,2X50GE,2X40GE,1X100GE,4X25GEFixedFormFactor,1X40GE,2X100GE,4X10GE,8X10GE,8X25GE,4X25GE
,4X10GEFixedFormFactor}]
 [-m MANAGEMENT_VLAN] [-j JUMPBOX_INTERFACE]
 [-a ADDITIONAL_BREAKOUT]
This command creates a SmartFabric Services cluster of Dell EMC OS10EE
switches with the information provided below.
optional arguments:
 -h, --help show this help message and exit
 -d DOMAIN, --domain DOMAIN
 Domain-Id for the SmartFabric Services cluster
 formation. Accepted Values [1..254].
 -u UPLINK, --uplink UPLINK
 Uplink Interfaces separated by a comma (,). If empty,
 it takes the default value for the platform. If there
 is no uplink, provide 'None/Null'
 -i ICL, --icl ICL VLT Inter Chassis Link(ICL) interfaces separated by a
 comma (,). If empty, it takes the default value for
 the platform. If there is no ICL value (in case of
 single node cluster), input the value as 'None/Null'
 -t, --tagged Flag to indicate if management VLAN is tagged on the
 on the TOR uplink ports. By default Uplinks are not
 tagged. Default management VLAN 1 is untagged on
 Uplink interfaces.
 -l, --lacp_mode Flag to indicate if LACP is to be enabled on the TOR
 uplink ports to the spine switches. By default LACP on
 TOR uplink ports is not enabled.
 -b 
{4X50GE,2X50GE,2X40GE,1X100GE,4X25GEFixedFormFactor,1X40GE,2X100GE,4X10GE,8X10GE,8X25GE,4X25GE
,4X10GEFixedFormFactor}, --breakout_uplink 
{4X50GE,2X50GE,2X40GE,1X100GE,4X25GEFixedFormFactor,1X40GE,2X100GE,4X10GE,8X10GE,8X25GE,4X25GE
,4X10GEFixedFormFactor}
 The breakout mode for uplink interfaces.
 -m MANAGEMENT_VLAN, --management_vlan MANAGEMENT_VLAN
 Public Management VLAN (Untagged VLAN). By default
 management VLAN is 1.
16