Users Guide

Table Of Contents
To disable the ports, select a port or multiple ports, and click Disable Admin Status.
The system displays the change status and update success message on completion.
Dell Technologies recommends to:
Enable the port status to operationally up before adding any devices to the port, if the port is disabled using the OMNI UI.
NOTE: Devices that are connected to the disabled port are not discovered.
Ensure that the ports are UP before adding any switches, when you expand the leaf and spine fabric deployments.
Ensure that the switch port is in UP, when onboarding a server to a leaf switch.
Configure breakout ports
Configure breakout ports on an interface of the leaf switch.
NOTE:
By default, the auto breakout feature is enabled in spine switches. OMNI UI does not provide an option to break out
ports in spine switches.
To configure the breakout ports in a leaf switch:
1. From the SmartFabric instance, select Switches .
2. From Leaf Switches category, select a leaf switch from the list.
102
OMNI support for SmartFabric instances